Loading...
HomeMy WebLinkAboutApplicationCOLLEGE STATION (Check one) ❑ Minor ($300.00) FOR OFFICE USE ONLY, P&Z CASE NO.:) I AY DATE SUBMITTED FINAL PLAT APPLICATION ❑ Amending ® Final ❑ Vacating ❑ Replat ($300.00) ($400.00) ($400.00) ($600.00)` 'Includes public hearing fee The following items must be submitted by an established filing deadline date for P&Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: X Filing Fee (see above) NOTE: Multiple Sheets - $55.00 per additional sheet N/A Variance Request to Subdivision Regulations — $100 (if applicable) X Development Permit Application Fee of $200.00 (if applicable). X Infrastructure Inspection Fee of $600.00 (applicable if any public infrastructure is being constructed) X Application completed in full. N/A Copy of original deed restrictions /covenants for replats (if applicable). X Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.) X One (1) copy of the approved Preliminary Plat and /or one (1) Master Plan (if applicable). X Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. X Two (2) copies of public infrastructure plans associated with this plat (if applicable). N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: Ongoing Phases NAME OF SUBDIVISION Waterwood Condominmums SPECIFIED LOCATION OF PROPOSED SUBDIVISION (Lot & Block) Lot 2, Block 1 E &M Jones Place APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Veronica J.B. Morgan. P.E. - Managing Partner Street Address 511 University Dr. E., Ste. 204 City College Station State TX Zip Code 77840 Phone Number (979) 260 -6963 PROPERTY OWNER'S INFORMATION: E -Mail Address v(a-mitchel land morgan.com Fax Number. (979) 260 -3564 Name Jim Stewart Street Address 4200 Woodland Park Court City Arlington State TX Zip Code 76013 E -Mail Address Phone Number (817) 994 -4663 ARCHITECT OR ENGINEER'S INFORMATION: Fax Number (817) 429 -8664 Name Veronica J.B. Morgan, P.E. - Managing Partner Street Address 511 University Dr. E. Ste. 204 City College Station State TX Zip Code 77840 E -Mail Address v(o)mitchellandmorgan.com Phone Number (979) 260 -6963 Fax Number (979) 260 -3564 Is there a temporary blanket easement on this property? If so, please provide the Volume and Page # 6/13/03 1 of 5 W Acreage - Total Property 13.72 Total # Of Lots 1 R -O -W Acreage .70ac Existing Use: Vacant Proposed Use: Condominiums Number Of Lots By Zoning District 1 / R-4 Average Acreage Of Each Residential Lot By Zoning District: R -4 / 7 AC Floodplain Acreage 0 A statement addressing any differences between the Final Plat and approved Master Plan and /or Preliminary Plat (if applicable): NONE Requested Variances To Subdivision Regulations & Reason For Same: NONE Requested Oversize Participation: See attached letter Total Linear Footage of Proposed Public: 510' Streets 976' Sidewalks x Sanitary Sewer Lines 520' Water Lines x Channels 75' Storm Sewers 1020' Bike Lanes / Paths Parkland bedication due prior to filing the Final Plat: ACREAGE: # of acres t be dedicated + $ development fee # of acres in fl plain # of acres in Bete ttiion NA # of acres in greenAys OR FEE IN LIEU OF LAND: # of Single - Family Dwellin \Unites X $556 = $ (date) Approved by.)Jarks & Recreation Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct, and complete. The undersigned hereby requests approval by the City of College Station of the above - identified final Al t and attests that this request does not amend any covenants or restrictions associated with this plat. Signature and ­7 L% Lo+ Date 6/13/03 2 of 5 t�itM Jon► tit ?Ljt�� SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific site /waterway alterations: ACKNOWLEDG I, V C�� �-► ✓� design engineer /owner, hereby acknowledge or affirm that: The ipformation and conclusions contained in the above plans and supporting documents comply with the current requ' a ents of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design StanVatds. As a condition of approval of this permit application, I agree to construct the improvements proposed in this app ' tion aaqWjr)g to )Nese documents and the requirements of Chapter 13 of the College Station City Code. Property Own Contractor CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.) A. 1, certify that any nonresidential structure on or proposed to be on this site as part of this appli a i e ' nated to prevent damage to the structure or its contents as a result of flooding from the 100 year storm. Engineer Li G Engi it, of any residential st ed i0he laWstX deral I C. I. \ not diminish the flood -carryi caps or development are consistent encroachments of floodways and of Date certify that the finished floor elevation of the lowest floor, including any proposed as part of this application is at or above the base flood elevation Administration Flood Hazard Study and maps, as amended. 1 0 1 4 Date , certify that the alterations or development covered by this permit shall y of the waterway adjoining or crossing this permitted site and that such alterations requirements of the City of College Station City Code, Chapter 13 concerning odway fringes. Engineer //� D. I, , do certify t the proposed alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insu ce Administration Flood Hazard Study. Engineer Conditions or comments as part of approval: Date In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. 6/13/03 3 of 5 F, AMJooesP✓sm SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) N 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 3. Title Block with the following information: K Name and address of subdivider, recorded owner, planner, engineer and surveyor. DS Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) 6/13/03 4 of 5 Date of preparation. ® Engineer's scale in feet. Total area intended to be developed. 4. North Arrow. 5. Subdivision boundary indicated by heavy lines. 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 7. All applicable certifications based on the type of final plat. Ownership and Dedication Surveyor and /or Engineer City Engineer (and City Planner, if a minor plat) Planning and Zoning Commission (delete if minor plat) Brazos County Clerk Brazos County Commissioners Court Approval (ETJ Plats only) 8. Paid tax certificates. 'VA 9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. 13. Matches the approved preliminary plat and /or master development plan. 6/13/03 4 of 5 EA M JoNIF"s li��M Ru4clt- 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed Streets. Continuous or end in a cul -de -sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. 7Q Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) �---°— Street offsets and /or intersection angles meet ordinance. [ Easements. ® [S A number or letter to identify each lot or site and each block. -- �8 — Greenbelt area /park linkages /parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and /or sidewalk layout of the subdivision. (may be combined with other utilities). n u nitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size /depth to meet the utility master plan and any future growth areas.) Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size /depth to meet the utility master plan and any future growth areas.) Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. Drainage Report. ` Erosion Control Plan (must be included in construction plans). 16. All off -site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. 17. Are there impact fees associated with this development? ❑ Yes $Q No Impact fees for R -1, R -2, & R -3 zoned final plats, must be paid prior to filing. 18. Will any construction occur in TexDOT rights -of -way? F Yes �lo If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. 6/13/03 5 of 5 ��� °���� � �a�, O �� \�