PREPARED 11/13/08, 12:01:13 INSPECTION TICKET PAGE 7
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/13/08
------------------------------------------------------------------------------------------------
ADDRESS . : 2803 EARL RUDDER FWY S 201 SUBDIV:
TENANT, NBR: FINISH OUT
CONTRACTOR G W WILLIAMS PHONE (979) 846-2717
OWNER MUCO VERDE, LLC ATTN: PHONE
PARCEL 440800-0001-0010
APPL NUMBER: 08-00002284 COMMERCIAL, HOSPITALS & INSTITUTIONS
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B115 01 9/02/08 DS BLDG, FRAMING TIME: 17:00
9/03/08 AP September 2, 2008 11:39:51 AM bboerboom.
B130 01 9/02/08 DS BLDG, INSULATION TIME: 17:00
9/03/08 AP September 2, 2008 11:40:00 AM bboerboom.
B125 01 lf/13/08 B BLDG, FINAL TIME: 17:00
1 � __ Novemberl13, 2008 11:38:43 AM ccourt.
6 r d AM jr'
-r17
------------------------------------ COMMENTS AND NOTES--------------------------------------
(11/24/21)08) Gina Southerland - Re Calling for C.O.@ 28 3 Earl Rudder Fwy S 201 Page 1
From: Rodney Harris
To: Gina Southerland
Date: 11/18/2008 4:32 PM
Subject: Re: Calling for C.O.@ 2803 Earl Rudder Fwy S 201
No Sanitation issues.
Rodney Harris
Sanitation Foreman
Public Works
Tel(979)764-3698
Fax(979)764-3489
email: rharris@cstx.gov
>>> Gina Southerland 11/17/2008 4:03 PM >>>
Finish out for doctor's office
BP# 08-2284
contact: Robert Payne @ 696-7272
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.00v
(11/24/2 )08) Gina Southerland - Re: Calling for C.O.@ 2803 Earl Rudder Fwy S 201 Page 1
From: Pete Garcia
To: COS
Date: 11/18/2008 4:09 PM
Subject: Re: Calling for C.O.@ 2803 Earl Rudder Fwy S 201
Attachments: Pete Garcia.vcf
They are OK.
'Do not ask the Lord to Guide your Footsteps if you are not wilting to move your Feet'
This e-mail and/or attachment is for the sole use of the intended recipient(s) and may contain confidential and /or legally privileged
information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please
contact the sender by reply e-rnail and destroy all electronic and paper copies of the original message and any attachments. Thank
You.
>>> On 11/17/2008 at 4:03 PM, in message<492195CD.6D9C.0039.0@cstx.gov>, Gina SOutherland wrote:
Finish out for doctor's office
BP# 08-2284
contact: Robert Payne @ 696-7272
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.00v
(11/24/2008) Gina Southerland - Re: Calling for C.O.@ 2803 Earl Rudder Fwy S 201 Page 1
From: Jerry Duffey
To: Gina Southerland
Date: 11/18/2008 3:20 PM
Subject: Re: Calling for C.O.@ 2803 Earl Rudder Fwy S 201
CC: Benjamin McCarty; Chris Haver; Christina Court; Eric Dotson; Eric Hu...
OK for CO from Fire
>>> Gina Southerland 11/17/2008 4:03 PM >>>
Finish out for doctor's office
BP# 08-2284
contact: Robert Payne @ 696-7272
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.gov
(11/24/2008) Gina Southerland - Re: Calling for C.O @ 2803 Earl Rudder Fwy S 201 Page 1
From: Donnie Willis
To: Southerland, Gina
Date: 11/18/2008 11:46 AM
Subject: Re: Calling for C.O.@ 2803 Earl Rudder Fwy S 201
OK with Drainage.
Donnie Willis, CFM
Environmental Engineering Technician
Certified Floodplain Manager
Public Works Department
979-764-6375 office
979-229-7632 cell
dwillis@cstx.gov
>>> On 11/17/2008 at 4:03 pm, in message<492195CD.6D9C.0039.0@cstx.gov>, Gina Southerland
wrote:
Finish out for doctor's office
BP# 08-2284
contact: Robert Payne @ 696-7272
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.csb(.gov
(11/20/2008) Kristen Green Re Calling for C O @ 2803 Earl Rudder Fwy S 201 Page#1
From: Mitchell Carson
To: Alan Gibbs; Benjamin McCarty; Brenda Godfrey; Brent Read; Bridgette ...
Date: 11/18/2008 7:48 AM
Subject: Re: Calling for C.O.@ 2803 Earl Rudder Fwy S 201
OK for CO .... Mitch
>>> Gina Southerland 11/17/2008 4:03 PM >>>
Finish out for doctor's office
BP# 08-2284
contact: Robert Payne @ 696-7272
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.gov
BUILDING PERMIT
CITY OF. COLINEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #•
Tenant nbr, name . . . . . .
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00002284 Date 8/07/08
423420
2803 EARL RUDDER FWY S 201
440800-0001-0010
FINISH OUT
COMMERCIAL, HOSPITALS & INSTITUTIONS
ADMIN. PROFESSIONAL
140000
Owner Contractor
MUCO VERDE, LLC ATTN: G W WILLIAMS
BAYLISS, J FRED ATTNY 4090 RAYMOND STOTZER
1721 BIRMINGHAM DR STE 206 COLLEGE STATION TX 77840
COLLEGE STATION TX 778454064 (979) 846-2717
--- Structure Information 000 000 DR. OFFICE TENANT FINISHOUT
Construction Type . . . . . NON-COMBUSTIBLE
Occupancy Type . . . . . . BUSINESS
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
HEATED AREA 1950.00
INTERIOR WALL TYPE SHEETROCK
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 4270.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . CC
Permit pin number . 592055
Permit Fee . . . . 580.00 Plan Check Fee .00
Issue Date . . . . 8/07/08 Valuation . . . . 140000
Expiration Date . . 2/03/09
Qty Unit Charge Per Extension
BASE FEE 460.00
40.00 3.0000 THOU BLDG, VAL 100001-500000 120.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT: 5" ADDRESS
NUMBERS, AND ON REAR DOOR(S): 2" HIGH ADDRESS NUMBERS AND
NAME OF BUSINESS. FOR MULTI -FAMILY RESIDENTIAL PROVIDE UNIT
NUMBER ON FRONT DOOR AND IDENTIFY EACH UNIT FRA REAR FIRE
-------------------------------------------C�_A ----------------------
BUILDING DEPT REPRESENTATIVE:
e
APPLICANT:
BUILDING PERMIT
CITY OF COLDEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00002284 Date 8/07/08
Application pin number . . . 423420
----------------------------------------------------------------------------
Special Notes and Comments
LANE. IDENTIFY MULTI -FAMILY BUILDINGS WITH 12" BUILDING
NUMBERS, VISIBLE FROM ALL ADJACENT/NEARBY FIRE LANES. ALL
NUMBERS AND LETTERS SHALL HAVE CONTRASTING BACKGROUNDS.
Shall advertise only the name of, uses of, or goods or
services available within the building, or tenant lease
space, to which the banner is attached.
Shall be mounted parallel to the face of the building.
Shall not be cantilevered away from the structure.
Shall not extend more than one foot from any exterior
building face, mansard, awning, or canopy.
Shall not obstruct any window, door, stairway, or other
opening intended for ingress or for needed ventilation or
light.
Shall not be attached to any tree, fence, or public utility
pole.
NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR
CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT
CONNECTION TO WATER SUPPLY, WATER SUPPLY LINES SERVING THE
THIRD FLOOR OR HIGHER, AND LAWN IRRIGATION SYSTEMS.
ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED
TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC
UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM
BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394.
ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394
PROVIDE COMBUSTION AIR: FOR GAS -FIRED APPLIANCES PER SECTION
304 OF THE 2006 INTERNATIONAL FUEL GAS CODE; FOR OTHER FUELS
TO COMPLY WITH CHAPTER 7 OF THE 2006 IMC.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN
AND INSTALL AS PER NFPA 72
NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND
RETURNED
PROVIDE FIRE EXTINGUISHERS) - VERIFY LOCATION AND PLACEMENT
WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC)
SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW
NO WORK ON SPRINKLER SYSTEM SHALL
BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED.
SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE
REQUIRED TO BE MONITORED BY AN APPROVED MONITORING
COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF, COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00002284 Date 8/07/08
Application pin number . . . 423420
----------------------------------------------------------------------------
Special Notes and Comments
SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE
PREVENTION DIVISION.
GUARDS SHALL COMPLY WITH SECTION 1013 OF THE 2006 IBC.
*Assure Proper GFI Locations, Including One Within 25, Of
Outside A/C Unit
Shall advertise only the name of, uses of, or goods or
services available within the building, or tenant lease
space, to which the sign is attached;
Shall be parallel to the face of the building;
Shall not extend more than one foot from any exterior
building face, mansard, awning, or canopy;
Shall not obstruct any window, door, stairway, or other
opening intended for ingress or for needed ventilation or
light; and
Shall not be attached to any tree, fence, or public utility
pole.
PROVIDE MINIMUM 42" CLEARANCE FROM CENTER LINE OF WATER
CLOSET TO EDGE OF LAVATORY OR WALL TO COMPLY WITH ANSI 2003,
ACCESSIBLE STANDARDS.
HANDRAILS SHALL COMPLY WITH SECTION R-311 (2003 IRC) OR
SECTION 1009 (2003 IBC) AS APPROPRIATE
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 150-o the Values Shall be
R-13 and R-30, above 15o the Ceiling Insulation is Increased
to R-38.
PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. A KEY FOR
EACH SHELL BUILDING AND/ OR TENANT DOOR IS REQUIRED.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
INTERIOR LIGHTING SHALL MEET THE CONTROLS AND WATTAGE
REQUIREMENTS OF SECTION 505 OF THE 2006 INTERNATIONAL ENERGY
CONSERVATION CODE.
All roof and ground -mounted mechanical equipment shall be
sreened from view or isolated so as not to be visible from
any public right-of-way or residential district within 150
feet of the subject lot, measured from a point five feet
above grade. Such screening shall be coordinated with the
building architecture and scale to maintain a unified
appearance. Acceptable methods of screening rooftop
---------------------- - ----- -A _
BUILDING DEPT REPRESENTATIVE:
APPLICANT: 07c�j4��
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00002284 Date 8/07/08
Application pin number . . . 423420
----------------------------------------------------------------------------
Special Notes and Comments
equipment may include, but are not limited to encasement,
parapet walls, or partition screens.
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
PROVIDE PANIC HARDWARE ON EXIT DOORS
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
CONSTRUCTION CONTRACTS OVER $50,000 REQUIRE SUBMISSION TO
THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR Q
(512) 463-3211 FOR MORE INFORMATION
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total
Plan Check Total
Grand Total
580.00 580.00 .00 .00
.00 .00 .00 .00
580.00 580.00 .00 .00
-------------------------- ----------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
'r11 APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COL.U--.GE S rAriON (979) 764-3570 (979) 764-3496 FAX
/z_nint &,tkw1#pw W 5trak s
WWW.CSTX.GOV
F%a'O se Only
DATE: I R RE�J
APPLICATION #
TEMP POLE #
ADDRESS/LOCATION: 080-9 EAkt_&AA6er2Wl fw%n _<K/-re. 0�
LOT BLOCK ,,// SUBDIVISION
���I
BUSINESS/OWNER NAME: { L4.&.g- ac
CONTRACTOR/HOMEOWNER: (;&) 4019.(&4 ►S IA.)C
SEC/PH
PHONE: 6/� 0 ^F�}t�0
PHONE: 94 —A
CONTACT PERSON FOR REVIEW COMMENTS: Z-9fIT AWIC PHONE: "7Z
O:Z. ) y i*�S-rcjz yep -a 7 1 7
FAX: EMAIL:
ELECTRICIAN: b0V%> z. /AX4 1949C.
HVAC: CMG/wa.ATE�,$fET�$
PLUMBER: "4& �L1►w""%�%/�G.�
GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTIONSHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEURENOVATION* TENT
RETAINING WALL
DESCRIPTION OF WORK: (Arr* tot
PROPOSED USE: b R s
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION NO. EABPRJ
4s-00.""
LUATION: $ 140 j000 TOTAL AREA: 1150 HEATED AREA: 11450
(Cost of Labor and Materials)
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
SEWER TAP:
❑ WATER TAP:
❑ OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
SIZE
SIZE
SINGLE E]
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE F] TRIPLE
ATTACHED F__j DETACHED
SIGNATURE OF APPLICANT: C---> ^�
*If proposed work involves new commercilral construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
............................................................
Official Use Only
Comments:
NO
Plans Examiner Zoning Official
I
COMcheck Software Version 3.5.2
Interior Lighting Compliance
Certificate
2006 IECC
Report Date: 07/17/08
Data filename: D:\ENERGY REPORTS\A01-0802 ST. JOSEPH MOB 2ND FLR TENN.cck
Section 1: Project Information
Project Type: New Construction
Project Title : St. Joseph MOB 2nd Floor Tennant Space
Construction Site: Owner/Agent:
Designer/Contractor:
North Forest Office Park
Swoboda Engineering
College Station, TX
7010 Coyote Run
Bryan, TX 77808
979-774-3400
Section 2: General Information
Building Use Description by: Activity Type
Activity Type(s) Floor Area
Healthcare -Clinic 4760
Section 3: Requirements Checklist
Interior Lighting:
1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Watts Proposed Watts Complies
4760 4735 YES
Controls, Switching, and Wiring:
❑ 2. Independent controls for each space (switch/occupancy sensor).
Exceptions:
Areas designated as security or emergency areas that must be continuously illuminated.
Lighting in stairways or corridors that are elements of the means of egress.
Lj 3. Master switch at entry to hotel/motel guest room.
C] 4. Individual dwelling units separately metered.
5. Each space provided with a manual control to provide uniform light reduction by at least 50%.
Exceptions:
Only one luminaire in space;
An occupant -sensing device controls the area;
The area is a corridor, storeroom, restroom, public lobby or sleeping unit.
Areas that use less than 0.6 Watts/sq.ft.
❑ 6. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft.
Exceptions:
Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security.
❑ 7. Photocell/astronomical time switch on exterior lights.
Exceptions:
Lighting intended for 24 hour use.
8. Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts).
Project Title: St. Joseph MOB 2nd Floor Tennant Space Report date: 07/17/08
Data filename: D:\ENERGY REPORTSW01-0802 ST. JOSEPH MOB 2ND FLR TENN.cck Page 1 of 3
w..a wrxe�wre�vr«r�A.,,� ,w.re
Pra}ad TOW St. Joseph K40D 2nd Fkw TarwK7i[ Spew Re dam 07MI
DMa nit mmi D, Y t 7RTSllM-OW2 ST. JOSEPH MOB 2ND FLR TENN.ck Pap 2 of 3
f
COMcheck Software Version 3.5.2
Interior Lighting Application
Worksheet
2006 IECC
Report Date:
Data filename: D:\ENERGY REPORTS\A01-0802 ST. JOSEPH MOB 2ND FLR TENN.cck
Section 1: Allowed Lighting Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts / ft2 (B x C)
Healthcare -Clinic 4760 1 4760
Total Allowed Watts = 4760
Section 2: Proposed Lighting Power Calculation
A
B
C
D
E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
Lamps/
# of
Fixture
(C X D)
Fixture
Fixtures
Watt.
Healthcare -Clinic (4760 y ft )
Linear Fluorescent 1: A: 2'X4' AIR HANDLING TROFFER / 48" T8 32W /
2
46
65
2990
Electronic
Linear Fluorescent 2: B: 2'X4' PARABOLIC AIR HANDLING / 48" T8 32W /
3
17
95
1615
Electronic
Linear Fluorescent 3: C: SURFACE MTD. FLUORESCENT STRIP / 48" T8 32W
2
2
65
130
/ Electronic
Total Proposed Watts = 4735
Section 3: Compliance Calculation
If the Total Allowed Watts minus the Total Proposed Watts is greater than or equal to zero, the building complies.
Total Allowed Watts = 4760
Total Proposed Watts = 4735
Project Compliance = 25
Project Title: St. Joseph MOB 2nd Floor Tennant Space Report date: 07/17/08
Data filename: D:\ENERGY REPORTS\A01-0802 ST. JOSEPH MOB 2ND FLR TENN.cck Page 3 of 3