HomeMy WebLinkAboutDEMO2008-02190DEMOLITION PERMIT Yam'
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Tenant nbr, name . . . . . .
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
ARTESIAN ASSETS LLC
301 CONGRESS
STE 555
AUSTIN TX 78701
08-00002190 Date 7/15/08
689320
100 CHURCH AVE
144500-0010-0031
R18590
DEMO
DEMOLITION, RESIDENTIAL 5+ UNITS
BOYETT
RESIDENTIAL
UNKNOWN
7000
Contractor
ALBO CONSTRUCTION
3888 DILLY SHAW TAP RD
BRYAN TX 77808
(979) 575-9423
--- Structure Information 000 000 DEMOLITION
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY
Other struct info . . . . . TRAFFIC IMPACT ANAL (TAZ) 450.00
----------------------------------------------------------------------------
Permit . . . . . . DEMOLITION PERMIT
Additional desc . . AC
Permit pin number . 587220
Permit Fee . . . . 25.00 Plan Check Fee .00
Issue Date . . . . 7/15/08 Valuation . . . . 7000
Expiration Date . . 1/11/09
Qty Unit Charge Per Extension
BASE FEE 25.00
----------------------------------------------------------------------------
Special Notes and Comments
*ALL UTILITIES MUST BE DISCONNECTED BEFORE DEMOLITION
BEGINS. PLUMBING SEWER LINES MUST BE CAPPED TO AVOID STORM
WATER FLOWING INTO LINES. MAINTAIN SAFE JOB SITE AND REMOVE
ALL DEBRI PROMPTLY.
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 25.00 25.00 .00 .00
--------------------------
BUILDING DEPT REPRESENTA7/,2:,
APPLICANT: ,C 1�'/.��► /Y/ /X /1
�6 2�IgD
�FIq�3Da10
DEMOLITION PERMIT '
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
Application pin number
Plan Check Total
Grand Total
. . . 08-00002190
. . . 689320
.00 .00
25.00 25.00
Page 2
Date 7/15/08
.00 .00
.00 .00
-
APPLICANT:
APPLICATION FOR BUILDING PERMIT DATE: — / L 'v TM(! REG
CITY OF COLLEGE STATION
1101 TEXAS AVENUE APPLICATION #
COLLEGE STATION, TX 77840 TEMP POLE #
CITY Or COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Pkrnxixp d CJtvelopruxr Srn�irrt
yy�� 77��WWW..CSTX.GOV
ADDRESS/LOCATION: it? (\\\`X Ly-, ( J� — �\W, (�OneY k
LOT BLOCK SUBDIVISION
BUSINESS/OWNER NAME:
PHONE:
SEC/PH
CONTRACTOR/HOMEOWNER: \�V C,DY VJl \ u (��i, Ll� l� PHONE: Q� j— j 7� - 3 as L
CONTACT PERSON FOR REVIEW COMMENTS:
FAX:
ELECTRICIAN:
HVAC:
PHONE:
EMAIL:
PLUMBER:
GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION* SHELL ONLY
EMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEL/RENOVATION* TENTS
DESCRIPTION OF WORK: Ow-'D`LN�n\r\
PROPOSED USE:
STRUCTURE USE:
HOMEOWNER ASSOC IATI ON/ARC H ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 1, Doa TOTAL AREA: HEATED AREA:
(Cost of Labor and Materials)
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
SEWER TAP:
WATER TAP:
❑ OTHER TAP:
❑ TEMP POLE
GARAGE TYPE
SIZE
SIZE
SIZE
SINGLE
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE
DETACHED 71
TRIPLE El
CARPORT
SIGNATURE OF APPLICANT: (l1/YL ZA �Za 44 �(/�IZ '�
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
............................................................
Official Use Only
Comments:
NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling I (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
❑ Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
PLM REPORT
Steve Moody Micro Services, Inc. NVLAP Lab No. 102056
1510 Randolph, Suite 602 TDH License No. 30-0094
Carrollton, Texas 75006 (972) 446-9482 PAT ID # 102577
Client: Austin Environmental, Inc. Lab Job No.: x5B-01710
Project : Northgate Project, 100 Church St., College Station, Tx Report Date: 03/04/2005
Project # ; AE05-60 Sample Date: 03/032005
Identification: Asbestos, Bulk Sample Analysis
Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116 Page 1 of 3
On 3/ 4/05, twenty-thrse (23) bulk material samples were submitted by Brett Plant of Austin Eavironmmtal, Inc. for asbestos analysis by PLM/DS.
Copies of the lab data sheets are atmched; additional information may be found therein. 'Ihe results are summarized below:
Sample Number
Client Sample Description / Location
Asbestos Content
NP-01A
Drywall Texture, Wall across from Restroom Doorway
None Detected - Drywall Material
21/o Chrysotile - Old Texture
None Detected - New Texture
NP-01B
Drywall Texture, 2nd Floor, Middle of Ceiling
None Detected - Drywall Material
21/o Chrysotile - Old Texture
None Detected - New Texture
NP-01C
Drywall. Texture, Main Room, Middle of Back Wall
None Detected - Drywall Material
2% Chrysotile - Old Texture
None Detected - New Texture
NP-02A
Linoleum. (Black), At Base of Stairwell, 1 st Floor
None Detected - Sheet Flooring
45% Chrysotile - Fiber Backing
NP-02B
Linoleum (Black), At Entry to Kitchen, 1 st Floor
None Detected - Sheet Flooring
45% Chrysotile - Fiber Backing
NP-02C
Linoleum (Black), Middle of Main Room, 1 st Floor
None Detected - Sheet Flooring
45% Chrysotile - Fiber Backing
NP-03A
Floor Tile (Green / Gray) and Black Mastic,
105/o Chrysotile - Floor Tile
Main Room Under Linoleum at Kitchen Entry
None Detected -Black Mastic
NP-03B
Floor Tile (Green / Gray) and Black Mastic,
10% Chrysotile - Floor Tile
Main Room Under Linoleum at Front Door
None Detected - Black Mastic
NP-03C
Floor Tile (Green / Gray) and Black Mastic,
10% Chrysotile - Floor Tile
Main Room Under Linoleum at Base of Stairs
None Detected - Black Mastic
NP-04A
Floor Tile and Mastic (Brown Pattern), Bottom Layer,
5% Chrysotile - Floor Tile
Main Room at Kitchen Entry
None Detected -Yellow Mastic
PLM REPORT
Steve Moody Micro Services, Inc.
NVLAP Lab No. 102056
1510 Randolph, Suite 602
TDH License No. 30-0084
Carrollton, Texas 75006 (972) 446-9482
PAT ID # 102577
Client: Austin Environmental, Inc. Lab Job No.: x5B-01710
Project : Northgate Project, 100 Church St., College Station, Tx Report Date: 03/04/2005
Project # : AE05-60 Sample Date: 03/03/2005
Identification: Asbestos, Bulk Sample Analysis
Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116 Page 2 of 3
On 3/ 4/05, twenty -throe (23) bulk material samples were submitted by Brent Plant of Austin F-nviromuental, Inc. for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are sunmurized below:
Sample Number
Client Sample Description / Location
Asbestos Content
NP-04B
Floor Tile and Mastic (Brown Pattern), Bottom Layer,
5% Chrysotile - Floor Tile
Main Room at Front Entry
None Detected - Yellow Mastic
NP-04C
Floor Tile and Mastic (Brown Pattern), Bottom Layer,
5% Chrysotile - Floor Tile
Main Room, Middle
None Detected - Yellow Mastic
NP-05A
Sheet Flooring (Floral Pattern), Upstairs,
None Detected - Sheet Flooring
Northeast Comer of Room, under Carpet
None Detected - Fiber Backing
NP-05B
Sheet Flooring (Floral Pattern), Upstairs,
None Detected - Sheet Flooring
Closet Middle, under Carpet
None Detected - Fiber Backing
NP-05C
Sheet Flooring (Floral Pattern), Upstairs,
None Detected - Sheet Flooring
Southwest Comer, under Carpet
None Detected - Fiber Backing
NP-06A
Ceiling Texture (Rough), Kitchen, Middle of Area
None Detected - Drywall Material
None Detected - Texture
NP-06B
Ceiling Texture (Rough), Kitchen, Behind West Facing Door
None Detected - Drywall Material
None Detected - Texture
NP-06C
Ceiling Texture (Rough), Kitchen, Next to Light on Ceiling
None Detected - Drywall Material
None Detected - Texture
NP-07A
Wall Parceling (Green / White), Restroom Back Wall
None Detected - Paneling
None Detected - Fiber Backing
None Detected - Brown Mastic
NP-07B
Wall Paneling (Green / White), Restroom Water Heater Closet,
None Detected - Paneling
Back Wall Middle
None Detected - Fiber Backing
None Detected - Brown Mastic
PLM REPORT
Steve Moody Micro Services, Inc.
NVLAP Lab No. 102056
1510 Randolph, Suite 602
TDH License No. 30-0084
Carrollton, Texas 75006 (972) 446-9482
PAT ID # 102577
Cheat: Austin Environmental, Inc.
Lab Job No.: x5B-01710
Project : Northgate Project, 100 Church St., College Station, Tx
Report Date: 03/04/2005
Project # : AE05-60 Sample Date: 03/03/2005
Identification: Asbestos, Bulk Sample Analysis
Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Page 3 of 3
On 3/ 4/05, twenty -throe (23) bulk material samples were submitted by Bran Plant of Austin &rviroruneatal, Inc. for asbestos analysis by PLM/DS.
Copies of the lab data shoots are attached; additional information may be found therein. The results are summarized
below:
Sample Number
Client Sample Description / Location
Asbestos Content
NP-07C
Wall Paneling (Green / White), Restroom Water Heater Closet,
None Detected - Paneling
Back Left
None Detected - Fiber Backing
None Detected - Brown Mastic
NP-08
Exterior Wmdow Glazing, South Facing Bottom Window,
None Detected - Glazing
Middle Pane
NP-09
Roofing Shingle, Southeast Comer of Building at Roof
None Detected - Roofing Shingle
None Detected - Roofing Felt
These samples wens analymd by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate.
Results may not be reproduced eaeept in full. This teat report relates only to the samples tested.
These beat results do not imply endomm=t by NVLAP or any agency of the U.S. Government
Accredited by the National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fier Analysis under Lab Code 102056. � ^ E
Analyst: Heather Deines
LJ V
Lab Director: Steve Moody Approved Signatory
Thank you for choosing Steve Moody Micro Services