Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2008-02188, 08-2189
WF106397X./_Q01 City of College Station ` 'PAGE 1 REQ. DATE: 07/23/08 07/23/08 14:13:15 LOCATION: 2456 STONE CASTLE CIR LOC ID: 210954 REQUESTOR: CL3 DEVELOPMENT ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 07/23/08 SCHED COMPLETION: 07/23/08 ******************************************************************************** JOB ORDER RESULT COMUMS PkREPARED 3/27/09, 12:05:34 INSPECTION TICKET PAGE 1 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: BUILDING INSPECTOR DATE 3/27/09 ADDRESS . : 2456 STONE CASTLE CIR SUBDIV: CASTLEGATE PH 2 SEC 7 CONTRACTOR CL3 DEVELOPMENT LLP PHONE (979) 361-0383 OWNER . . PHONE PARCEL . . 184200-2720-0020 APPL NUMBER: 08-00002188 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/19/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00 8/19/08 DP August 18, 2008 1:57:24 PM glsouth. rebar inspection Too much water in beams. Need 3 " of clearance of space between steel and bottom of beams. Repair plastic at several locations. Tie bottom beam steel together at overlaps. B100 02 8/20/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00 8/20/08 AP August 20, 2008 11:32:34 AM ccourt. rebar Strings up, slab ground installed. B115 01 12/08/08 RH BLDG, FRAMING TIME: 17:00 12/08/08 DP December 8, 2008 9:38:20 AM kgreen. Need nuts on anchors. Need anchors within 12" of floor plate ends at doors. Need bolts and bracing on wall between garage and dining room. Need to double up joist at attic accesses. Tape seal all loose Tyvek and all penetrations through Tyvek. Properly fireblock fireplace to attic and between floors. Also, fireblock at 2nd floor attic. Need proper nail guard for gas line on 2nd floor at floor plate. Draftstop all chases into attic on 2nd floor and on 1st floor at stairs. Need temp glass at master tub. Need joist hangers at 2nd floor ceiling. Need a min. 6" at the inside turns on the stair winders. Holes bored more than 1/3 the depth of the floor joist and closer than 2" from the top of the joist at Kitchen area. Holes bored within 2" of the bottom of floor joist in the laundry room. -ok to insulate B115 02 12/12/08 RH BLDG, FRAMING TIME: 17:00 12/12/08 DP December 12, 2008 11:37:53 AM kgreen. Still need anchor bolts for braced wall between diningroom and garage. Need to double joist for 2nd floor attic access. Need joist hangers for 2nd floor. 1 in livingroom and 1 over stairs. Note: by building final need min. 6" at inside turns on stair winders and temp glass at master tub. B130 01 12/12/08 RH BLDG, INSULATION TIME: 17:00 12/12/08 DA December 12, 2008 11:38:02 AM kgreen. b� w B115 03 12/15/08 RH 12/15/08 AP B130 02 12/15/08 RH 12/15/08 AP Did not complete framing notes. BLDG, FRAMING TIME: 17:00 December 12, 2008 4:46:18 PM ccourt. Will need 6" on turns at stairs and temp glass at master tub by building final. BLDG, INSULATION TIME: 17:00 B125 01 /�7/99 BLDG, FINAL TIME: 17:00 _3 3/d' 0'q /►B 1`F� �C March 27, 2009 11:50:22 AM ccourt. -------------------------------------- COMMENTS AND NOTES-------------------------------------- -4k- rri" peer , S tns�zlle� �� Apr 02 09 01:59p Scott Lingren 979 774-0486 p.1 SUBTERRANEAN TERMITE PRECONSTRUCTION DISCLOSURE FOR EACH ESTIMATE O For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember that Four architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If you have any questions, contact the pest control company or the Texas Department of Agriculture, Structural Pest Control Service, P.O. Box 12847, Austin, Texas 78711 2847. Phone: (512) 305-8250. Name of Customer Address -1 6 (9 ( j')e C City 1; ct.+� T— State T� Zip - -7tO Location to be Treated _ f--1 `�u.��' L�tji' Cam' ���t�' =]1 �� , / , Type of Treatment: 14 Full [ ] Partial [ ] Wood [ ] Bait [ ] Commercial [ j Single Family A label of ��S kt^ tern- ticide(s) is enclosed. The percentage of the tern-ducide(s) to be applied at this location is a 0( E3 K'arranty Information provided must include the Complete Details of any Warranty provided and the following. Time Period of Warranty; Renewal Options and Cost, and Obligations ojthe Contracting Parties. If the warranty does not include the entire structure treated, the areas included in the warranty are: (specify) Total Square Feet to be Treated: zo t- 0 Total Linear Feet to be Treated: Approximate Measuremenis of the Structure(s) to be Treated: ]t`� �� h 4 vI"\ P-�>cJ �, (-�co� L i vlI/VZCD,g Signature of Certified Applicator or Printed Name Da#P Technician Completing Estimate VeV�vs PtO (©o*��,i Name of Pest Control Company TPCL. No. Licensed and regulated under the Tuns Structural Pest Control Act Texas Department or Agriculture, Structural Pest Control Service, P.O. Box 12847, Austin, Texas 78711-2847, Phone: (512) -8250. Sample Farm—119/01107 Page 1 of 2 i Apr 02 09 01:59p Scott Lingren 979 774-M6 p.2 Deseriution of Structure(s) Additional Information Before conducting a termite preconstraction treatment, the company will present a complete diagram of the structure including construction details. When construction prevents performance of a full treatment, in accordance frith a bid for full treatment, any change to a partial treatment by the company providing the treatment vtill be permitted if the owner of the structure or the person in charge of the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amended diagram showing the exact areas to be treated. Copies must he sent to the o,,rner of the property within seven days of the application. THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED (SPCSID4). THE BOARD APPROVED SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT SERVICE. -This form includes the minimum requirements and information. It may also include or be revised to include a company logo and additional information. Sample Form—09/01107 Page 2 of t , BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00002188 Date 7/23/08 Application pin number . . . 486864 Property Address . . . . . . 2456 STONE CASTLE CIR Property ID: 184200-2720-0020 R 4. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE PH 2 SEC 7 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 200000 Owner Contractor ------------------------ ------------------------ CL3 DEVELOPMENT LLP 1601 WOODBIN CT BRYAN TX 77802 (979) 361-0383 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 14.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 30.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID DUE FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT o GLAZING 14.00 GLAZING U-FACTOR .64 HEATED AREA 2768.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 5.00 EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .40 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- TRAFFIC IMPACT ANAL (TAZ) 441.00 Permit BUILDING PERMIT Additional desc AC Permit pin number 589135 Permit Fee . . . . 760.00 Plan Check Fee .00 Issue Date . . . . 7/23/08 Valuation . . . . 200000 Expiration Date . . 1/19/09 .14 ---------------------------------------- BUILDING DEPT REPRESENTATIVE - APPLICANT: '/Zi1 - � L/ !A , BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00002188 Date 7/23/08 Application pin number . . . 486864 Qty Unit Charge Per Extension BASE FEE 460.00 100.00 3.0000 THOU BLDG, VAL 100001-500000 300.00 ---------------------------------------------------------------------------- Special Notes and Comments -If Living Room closet has rod and shelf then meets bedroom characteristic and the room must then meet electrical requirements. -Family Room Ceiling Height may determine stud size and spacing. -Narrow Wall Bracing Fully Sheathed with 18" Minimum APA Garage Framing and Interior Anchors and Bracing to the Right of Front Door Area. *IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. *Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. *THE COMBINED SOLAR. HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 200-o A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. Replacement Windows to meet .40 Solar Heat Gain and .65 U-Factors. *STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 15% the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ADD SMOKE DETECTOR(S) PER NOTES ON PLANS *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE ICINITY OF THE . -----------------------------------------------------,�'�✓�}-�"�------- BUILDING DEPT REPRESENTATIVE: APPLICANT: M."_Wi110KO0! 2 a1 40M CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00002188 Date 7/23/08 Application pin number . . . 486864 ---------------------------------------------------------------------------- Special Notes and Comments BEDROOMS *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2006 IRC) *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ---------------------------------------------- vi------try---,/�------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00002188 Application pin number . . . 486864 Page 4 Date 7/23/08 Special Notes and Comments *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 * THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD xt?_ BUILDING DEPT REPRESENTATIVE: APPLICANT: �"r s z.. ,1 �� BUILDING PERMIT CITY OF COLLEGE STATION ' 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00002188 Date 7/23/08 Application pin number . . . 486864 ---------------------------------------------------------------------------- Special Notes and Comments *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . IMPACT FEE AREA 97-01 98.39 SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 760.00 760.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 848.39 848.39 .00 .00 --------------------------------------------- 1------ - - BUILDING DEPT REPRESEENTATIVE : j✓�. '�'�'� APPLICANT: - /w „'s _ .. BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 6 Application Number . . . . . 08-00002188 Date 7/23/08 Application pin number . . . 486864 Grand Total 1608.39 1608.39 .00 .00 BUILDING DEPT REPRESENTATIVE: l) AA.AA f?-U40* APPLICANT: — c TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00002189 Date 7/23/08 Application pin number . . . 588092 Property Address . . . . . . 2456 STONE CASTLE CIR Property ID: 184200-2720-0020 R #. Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE PH 2 SEC 7 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ CL3 DEVELOPMENT LLP 1601 WOODBIN CT BRYAN TX 77802 (979) 361-0383 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc AC Permit pin number 589143 Permit Fee . . . . 20.00 Issue Date . . . . 7/23/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited ---------- Due Permit Fee Total 20.00 -------------------- 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 -------------------------------------------------Y.✓- 464e"_- BUILDING DEPT REPRE�TATIVE: APPLICANT: 110�& - N '1 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OFCOLLEGE STATION (979) 764-3570 (979) 764-3496 FAX PLimi;q c' LXes:,kpmnt,Yt -ket WWW.CSTX.GOV ADDRESS/LOCATION: DATE: TRC i APPLICATION # TEMP POLE # 0-- LOT /' BLOCK SUBDIVISION I SEC/PH BUSINESS/OWNER NAME: �� e 4I1_p PHONE: 5 3It/ U� C p f � CONTRACTOR/HOMEOWNER: � � G� C,\0{�./� PHONE: �7—�?r o CONTACT PERSON FOR REVIEW COMMENTS: I RI PP [-u%67 PHONE: L Z/ r � D !C FAX: 9n AZ9 A ELECTRICIAN: JI/\clt 6V-V HVAC: ACCESSORY/STORAGE ITION O EST, SURVEY) DIPL LANs REQUIRED) EMAIL:_ nn !GL cS JP UA' l� .QQd jn �ost— rr PLUMBER: L ?I ws �/y1 GOOD CENTS (Residential only): VING NEW CONSTRUCTION' PORTABLE STORAGE (RESIDENTIAL) PORTABLE STORAGE (NON-RESIDENTIAL) REMODEL/RENOVATION" RE -ROOF SHELL ONLY SLAB ONLY SWIMMING POOL TENTS TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 42 0b . a0 0 ✓ TOTAL AREA: 3 HEATED AREA: 2l Ly (Cost oflabor afid Materials) VPUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM SEWER TAP: II SIZE WATER TAP: 3/7 SIZE ❑ OTHER TAP: SIZE �EMP POLE GARAGE TYPE: SINGLE ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE TRIPLE 'ETACHED F)CARPOR ,Poet( 54PJ SIGNATURE OF APPLICANT: ���I -' "If proposed work involves new commercial constructs n or facade improvements/renovations to an existing commercial property, building elevations are required. ............................................................ Official Use Only ��_ co � Corr-glents: S r NO — Z*W rjft Gvire/uv/ Plans Examiner Zoning Official — G*L14V CQ, *1 115 f 1, I 1 Tk� X Sl�stock — nY Sl e �� / 8,('Aff v. A454 G �,e s e LO �H)DW S Vol, Akj'ql c.rmly 40 Rqj- . of rx4d— Energy Code Compliance Information % Glazing of exterior walls b Insulation R value of exterior walls Insulation R value of ceiling I (flat areas) 3 O Insulation R value of ceiling 2 (vaulted areas/no attic) 3 Glazing SHGC (Solar Heat Gain Coefficient) o Lid Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. PLAN REVIEW (*fl ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning dDevelopment Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE. Ao_ 0 8 BUILDING ADDRESS: �,qS!� 576-W 0-1e CIO- 1. Foundation Requirements- Minimum City Foundation Standards N A 41,0 K A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated fl#JCLK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans TAIM F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing 1. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. K 6 K PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& DevelopmentServiar COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details N 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Cha ter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N O 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location (*t/4" CITY OF COLLEGE STATION Planning d Development Serviat PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION; TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N AfaKI B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A K A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 860 N Permitted use for district .Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N K Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow 14 Elevation certificate needed A K "APPROVED PLANS PER IRC SECTION R106.3.1." , 4". - ,I--/ -0'PT� ANS EXAMINER DATE CITY OF COLLEGE STATION *** CUSTOMER RECEIPT *** Oper: KGREEN Type: CT Drawer: 1 Date: 4/02/09 00 Receipt no: 216586 Descrip08on 2Quantity Amount 188 DL 00 BUILDING PERMITS 1.00 $54.00 TRIPP LEWIS RED TAG FEES MV#809498 KG Tender detail MC MASTERCAR 809498 $54.00 Total tendered $54.00 Total payment $54.80 Trans date: 4/02/09 Time: 10:10:43 THANK YOU — 80.88' 1 19'-10 5 m rn 1 N I to M 1 I 1 CONC \ I I I I DRIVE 20' REAR SETBACK I / C25_).S, is 1 I I I I I N c0 I I I I %ft 46.52� ♦ I STONE CASTLE CIR. SITE PLAN SCALE: 1 "=20'-0" I tn CASTLEGATE SEC-7 BLK-2 LOT-2