Loading...
HomeMy WebLinkAboutRMDL2008-02179BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 ` FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Tenant nbr, name . . . . . . Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner ROBERTSON, PEARL MARIE (LIFE ESTATE 9307 WHITNEY LN COLLEGE STATION TX 77845 08-00002179 Date 7/21/08 575812 9307 WHITNEY LN 668700-1033-0040 R104863 FOUNDATION REPAIR RESIDENTIAL, REMODEL & RENOVATION WOODCREEK #10 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 4950 Contractor ANCHOR PIERS, LLC. 2924 CAIN RD COLLEGE STATION TX 77845 (979) 219-2774 --- Structure Information 000 000 REPAIR PIERS Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . IMPACT/PRORATA FEES PAID N/A HEATED AREA .10 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS .10 NUMBER OF BEDROOMS .10 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . CC Permit pin number . 588335 Permit Fee . . . . 35.00 Plan Check Fee .00 Issue Date . . . . 7/21/08 Valuation . . . . 4950 Expiration Date . . 1/17/09 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 5.0000 THOU BLDG, VAL 1001-50000 20.00 ---------------------------------------------------------------------------- Special Notes and Comments -12 Repair Piers *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *ALL PLUMBING, ELECTRICAL, AND HVAC (m chanical) WORK MUST ------------------------------- ----------------- - 'r . �si------------ BUILDING DEPT REPRES TIVE : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 ' FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00002179 Date 7/21/08 Application pin number . . . 575812 ---------------------------------------------------------------------------- Special Notes and Comments BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited Due -------------------- ----------------- Permit Fee Total 35.00 35.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 35.00 35.00 .00 .00 ------------------------------------------------6`.� --�s�------------ BUILDING DEPT REPRE NTATIVE: APPLICANT: 1 APPLICATION FOR BUILDING PERMIT DATE: R CITY OF COLLEGE STATION ' APPLICATION 1101 TEXAS AVENUE p COLLEGE STATION, TX 77840 TEMP POLE # CCIYOF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Mmnirtf 6 Drndupvmnc Smice WWW.CSTX.GOV ADDRE551LOCATION: 3D / � �1L/ LOT BLOCK /� SUBDIVISION / SEC/PH r BUSINESSIOWNER NAME: e4z& �O%��rl �d/PHONE: fit?' + - �'Z 1 CONTRACTORIHOMEOWNER: lzQ f?A--pA'sZ PHONE: 2 t �T - Z7% L/ CONTACT PERSON FOR REVIEW COMMENTS: FAX: ELECTRICIAN: HVAC: PHONE: EMAIL: PLUMBER: GOOD CENTS tResidentlal only): ACCESSORYISTORAGE MOVING RE -ROOF ADDITION NEW CONSTRUCTION" SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMO DEU RENOVATION* TENTS DESCRIPTION OF WORK: /2 PROPOSED USE: STRUCTURE USE: e_ HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (fAS) PROJECT REGISTRATION# EABPRJ /' VALUATION: $ J O d TOTAL AREA: HEATED AREA: (Cost oftabor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM ❑ SEWER TAP: SIZE ❑ WATER TAP. ❑ OTHER TAP: ❑ TEMP POLE GARAGE TYPE: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: SIZE FOUNDATION TYPE: _ SIZE ROOF TYPE: _ SINGLE DOUBLE TRIPLE ATTACHED DET HED a CARPORT SIGNATURE OF APPLICANT: - l `If proposed work involves new commercial construction or facade improWm1britstrenovations to an existing commercial property, building elevations are required. ♦11!!1l1/11l11111•♦�111111111♦♦11111l/11•♦111/♦111111111/11♦ Ofcia1 Use Only :1A Co ents: r?E_jiAWNO Plans Examiner Zoning Official 9-d 9£Z00696L6 e£Z:Zo 80 91, Inf h,- !�ey);7zir _A 2924:Cain Road 'College Station, TX.77845 Date: office: (979) 690-2020. 690-0235 AGREEMENT �'-"�-• , Anchor Piers LLC, called Contractor, and �� ' Owner agree that the sum `- af $ ,G%ry',ad , to be paid as follows: , le'-, after piers are poured, balance on completion. Contractor will furnish labor, equipment and materials to perform the following described work to the hereinafter described Story btliiding or structure located at: Phone (h) 1 , 7 =f - > 2 u (W) C_.-/3 Structure 1. The work shall consist of the installation of ��^ piers with nine inch diameter shafts drilled to 8" to 12' , water I able rocks and/or man placed objects permitting. The bottom of the shaft will have a bell footing of 20 inches in diameter, unless rock is encountered. 2. Contractor assumes no responsibility for any under slab plumbing. It may currently be cracked, broken, deterio- rated or may do so in the leveling process. Any repairs, if required are the sole responsibility of the owner. 3. Job site will be clean of all excess dirt and material. 4.. Contractor will carry all required insurance. 5. When in piers are called for, contractor will patch floors. Patches will be made with concrete to wooden floor level. Carpet will NOT be stretched. 6. Where surfaces such as concrete floors or patios are broken in order to install piers, Contractor will patch such texture of the original material. Special surface such as area. The patches, however, will not match he color or Flagstone, Spanish Tile, Brick or other such special materials will be restored at a cost in addition to pier installstion. 7. In foundation leveling, conditions might appear when work is begun that were not visible when estimate was submitted, such as, insufficient reinforcing steel in concrete slab, and/or other original foundation structural deficiency -In such cases the guarantee becomes invalid. 8. SPECIAL PROVISIONS: No Subcontractors. 4� .� ;.; : , ; , ,1; , •. , : "` /�",� 9. LIFETIME SERVICE AGREEMENT If any raising is necessary due to settling during the first five years from date of completion of the job, Contractor will re -raise the settled area without cost to the OWNER. For additional years, servicing, if required, will be done at the rate of // 0 per adjusted pier, labor and materials included, ` plus or minus the U.S. Consumer Price Index each year. This service agreement applies only to the piers Installed by Contractor. h, ;7111S AGREEMENT TRANSFERABLE TO NEW OWNERS. NOTIFICATION MUST BE TENDERED IN WRITING WITHIN 30 DAYS OF OWNERSHIP. it -is understood agreed that in order to perform the above described work it is possible that sheetrock, wallpaper, or other rigid material may crack. Therefore, the above figure does not include any redecorating, repairing, electrical work or the replacement of any material not called for in this agreement. Contractor upon request from owner, will transplant plants and shrubs.obstructing operations, and replace same, _srvival of shrubs and plants cannot be auaranteed. It is understood and agreed that Contractor will fumish all the labor, equipment and material and will perform all necessary work in connection with this job, in a good workmanlike manner. The Owner may order extra work to be done not contemplated by the contract. In which event, a separate Agreement for such work shall be entered between the Owner and the Contractor. No oral representation made by anyone can change or modify this Agreement. This Agreement in order to be binding b� both parties, must be signed in the space provided below, and the original copy returned to this office within days from the date shown above. Anchor Piers LLC G Owner Manager A L•d 9EZ00696Z6 etiZ:L0 90 96 Inr ... ItIER FO UNDA TION DE TAILS FOR REPAIR ONLY TO DAMAGED FOUNDATIONS WHERE SPECIFICALLY DESIGNATED EXISTING SLAB & BEAM i /-GRADE lw- SHIMBGROUT 8"x8"x12" SOLID CONC. 1"MIN. 8" 1"MIN. BLOCKS r JACK SPACE POUR CAP & 6 - 44 RODS ' �-- FOOTING AT 3 EACH WAY THE SAME '- TIME ALL CONCRETE TO BE 5 SACK W/ 1-1/2" ROCK ra" 2.2" all 3 - H4 VERT. < Ilr W/ 02 TIES i 18"O.C. OX n l7 .Q Q I a M o Ul z a 3 t4 y OJ 9" DIANL O la LC In n er 6 r � O 0 STABLE CLAY 101 2G'DIAM. SIDE VIEW FRONT VIEW 9•d 9EZ00696L6 obZ:LO 90 96 Inf