HomeMy WebLinkAboutDEMO2008-02165OS - oU(VJT
t
v — = DEMOLITION PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 08-00002165 Date 7/17/08
Application pin number . . . 385415
Property Address . . . . . . 303 COLLEGE MAIN
Property ID: 144500-0006-0260
R #: R18567
Tenant nbr, name . . . . . . CEDAR LANE
Application type description DEMOLITION, COMMERCIAL
Subdivision Name . . . . . . BOYETT
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . UNKNOWN
Application valuation . . . . 500
Owner Contractor
------------------------ ------------------------
FORREST, ROBERT J OASIS POOLS
3011 WESTWOOD MAIN DR 2151 HARVEY MITCHELL PKWY S
BRYAN TX 778073216 SUITE 323
COLLEGE STATION TX 77840
(979) 739-7717
--- Structure Information 000 000 DEMO FOR FUTURE BAR/ TAVERN
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . ASSEMBLY (IBC)
Other struct info . . . . . TRAFFIC IMPACT ANAL (TAZ) 238.00
----------------------------------------------------------------------------
Permit . . . . . . DEMOLITION PERMIT
Additional desc . . AC
Permit pin number . 587972
Permit Fee . . . . 25.00 Plan Check Fee .00
Issue Date . . . . 7/17/08 Valuation . . . . 500
Expiration Date . . 1/13/09
Qty Unit Charge Per Extension
BASE FEE 25.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT: 5" ADDRESS
NUMBERS, AND ON REAR DOOR(S): 2" HIGH ADDRESS NUMBERS AND
NAME OF BUSINESS. FOR MULTI -FAMILY RESIDENTIAL PROVIDE UNIT
NUMBER ON FRONT DOOR AND IDENTIFY EACH UNIT FROM A REAR FIRE
LANE. IDENTIFY MULTI -FAMILY BUILDINGS WITH 12" BUILDING
NUMBERS, VISIBLE FROM ALL ADJACENT/NEARBY FIRE LANES. ALL
NUMBERS AND LETTERS SHALL HAVE CONTRASTING BACKGROUNDS.
THE TEXAS DEPARTMENT OF HEALTH REQUIRES AN ASBESTOS SURVEY
IN CERTAIN CIRCUMSTANCES - CALL TDH @ (254) 778-6744 FOR
MORE INFORMATION
*ALL UTILITIES MUST BE DISCONNECTED BEFORE DEMOLITION
-------------------------------------------A ---------------------
BUILDING DEPT1�SENTATIVE:
APPLICANT: N.. ZO2/l
DEMOLITION PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
2
Application Number . . . . .
08-00002165 Date
7/17/08
Application pin number . . .
385415
----------------------------------------------------------------------------
Special Notes and Comments
BEGINS. PLUMBING SEWER LINES
MUST BE CAPPED TO AVOID STORM
WATER FLOWING INTO LINES. MAINTAIN
SAFE JOB SITE AND REMOVE
ALL DEBRI PROMPTLY.
*ELECTRICAL SHALL BE INSTALLED
PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*Assure Proper GFI Locations,
Including One Within 25' Of
Outside A/C Unit
CONSTRUCTION ACTIVITY BETWEEN
THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE
NOISE ORDINANCE (MAX. 55 DBA)
*POST PERMIT CARD ON JOB SITE
TO BE VISIBLE FROM ROAD
*ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited Due
------------------------------
Permit Fee Total 25.00
25.00 .00
.00
Plan Check Total .00
.00 .00
.00
Grand Total 25.00
25.00 .00
.00
------------------------------ -------------------
BUILDING DEPT REPRESENTATIVE: -�
APPLICANT:
.1
I CA
CITY OF COLI1?GE STATION
Planning t¢ Dewtoptuent S-4 a
ADDRESS/LOCATION:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
LOT BLOCK SUBDIVISION
BUSINESS/OWNER NAME:p(Q� ��jp\.��1C{ PHONE:
CONTRACTOR/HOMEOWNER:, — HONE:
CONTACT CONTACT PERSON FOR REVIEW COMMENTS:
FAX:
ELECTRICIAN:
HVAC:
PHONE:
EMAIL:
PLUMBER:
GOOD CENTS (Residential only):
SEC/PH
1779- *73,4.-7'77) "7
ESSORY/STORAGE MOVING RE -ROOF
DDITION NEW CONSTRUCTION* SHELL ONLY
DEMOLITION (ASBESTOS SURVEY PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEL/RENOVATION* TENT
RETAINING WALL
DESCRIPTION OF WORK: F_ay.Chft"o
PROPOSED USE:
STRUCTURE USE: \f cy��
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION NO. EABPRJ
C9° z
VALUATION: $ � TOTAL AREA: HEATED AREA:
(Cost o abor and Materials)
❑ PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
❑ SEWER TAP:
❑ WATER TAP:
❑ OTHER TAP:
❑ TEMP POLE
GARAGE TYPE
SIZE
SIZE
SIZE
SINGLE 1�
�
ATTACHED / I
SIGNATURE OF APPLICANT:
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE F7 TRIPLE a
DETA ED "'= CARPORT
*If proposed work involves new com _rrb�f�y� nNr facade improvements/renovations to an existing
commercial property, building elevations are required.
............................................................
Official Use Only
�/ Comments:
e(5br NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
❑ Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
TO: Ben
FROM: Bobby
SUBJECT: 303 College Main, Asbestos Findings
DATE: July 12, 2008
Ben,
Just wanted to let you know, and confirmed by survey, asbestos was found in
employee bathroom tile and mastic on interior floor. To comply with code we will not
remove employee bath tiles, but tile over existing (recommended by asbestos testing
company) also the mastic will not be removed and will be sealed over. I will also take
before and after pictures of before mentioned areas to keep for both of our files, thanks
again for your patience and support.
A!9
Bobby Grabowski
Steve Moody Micro Services, LLC PLM Detail Report
NVLAP Lab No. 102056
2051 Valley View Lane Supplement to PLM Summary Report
TDSHS License No. 30-0084
Farmers Branch, TX 75234
Client : Austin Environmental, Inc.
Lab Job No.: 08B-08192
Project : Cedarlane, Vacant Bar, 303 College Main, C.S., Texas Report Date: 07/08/2008
Project # : AE08-364
Page 2 of 2
Sample Number
Layer
% Of
ISample
Components
% of
I
JAnalysis
Analyst
Laver
I Date
05B Drywall Material (White)
70%
Cellulose Fibers
5%
07/08 JO
Gypsum / Binders
95%
DW Paper Facing (Tan)
10%
Cellulose Fibers
100%
Texture (White)
20%
Calcite / Talc / Binders
100%
05C Drywall Material (White)
87%
Cellulose Fibers
5%
07/08 JO
Gypsum / Binders
95%
DW Paper Facing (Tan)
10%
Cellulose Fibers
100%
Paint / Texture (White)
3%
Calcite
25%
Pigment / Binders
75%
06A Insulation (Orange)
95%
Mineral Wool Fibers
95%
07/08 JO
Resin Binders
5%
Paper/Tar/Foil Wrap (Tan / Silver)
5%
Cellulose Fibers
40%
Glass Wool Fibers
10%
Tar Binders
30%
Metal Foil
20%
06B Insulation (Orange)
95%
Mineral Wool Fibers
95%
07/08 JO
Resin Binders
5%
Paper/Tar/Foil Wrap (Tan / Silver)
5%
Cellulose Fibers
40%
Glass Wool Fibers
10%
Tar Binders
30%
Metal Foil
20%
06C Insulation (Orange)
95%
Mineral Wool Fibers
95%n
07/08 JO
Resin Binders
5%
Paper/Tar/Foil Wrap (Tan / Silver)
5%
Cellulose Fibers
40%
Glass Wool Fibers
10%
Tar Binders
30%
Metal Foil
20%
Steve Moody Micro Services, LLC
PLM Detail Report
NVLAP Lab No. 102056
2051 Valley View Lane
Supplement to PLM Summary Report
TDSHS License No. 30-0084
Farmers Branch, TX 75234
Client:
Austin Environmental, Inc.
Lab Job No.: 08M8192
Project :
Cedarlane, Vacant Bar, 303 College Main, C.S., Texas Report Date: 07/08/2008
Project # :
AE08-364
Page 1 of 2
Sample Number
Layer
ISampl
Components
La er
ls
DateOe
Analyst
OIA
Acoustic Tile (Light Grey)
100%
Cellulose Fibers
80%
07/08
JO
Perlite
20%
01B
Acoustic Tile (Light Grey)
100%
Cellulose Fibers
80%
07/08
JO
Perlite
20%
01C
Acoustic Tile (Light Grey)
100%
Cellulose Fibers
80%
07/08
JO
Perlite
20%
02A
Sheet Flooring (Tan)
50%
Synthetic Foam
70%
07/08
JO
Vinyl Binders
30%
Fiber Backing (Light Grey)
50%
Chrysotile
65%
Binders / Fillers
35%
02B
Not Analyzed - Positive Stop
100%
07/08
JO
02C
Not Analyzed - Positive Stop
100%
07/08
JO
03A
Floor Tile (Off -White)
95%
Calcite / Vinyl Binders
100%
07/08
JO
Black Mastic (Black)
5%
Chrysotile
3%
Tar Binders
97%
03B
Not Analyzed - Positive Stop
100%
07/08
JO
03C
Not Analyzed - Positive Stop
100%
07/08
JO
04A
Thermal Insulation (Brown)
100%
Mineral Wool Fibers
98%
07/08
JO
Resin Binders
2%
04B
Thermal Insulation (Brown)
100%
Mineral Wool Fibers
98%
07/08
JO
Resin Binders
2%
04C
Thermal Insulation (Brown)
100%
Mineral Wool Fibers
98%
07/08
JO
Resin Binders
2%
05A
Drywall Material (White)
70%
Cellulose Fibers
5%
07/08
JO
Gypsum / Binders
95%
DW Paper Facing (Tan)
10%
Cellulose Fibers
100%
Texture (White)
20%
Calcite / Talc / Binders
100%a
PLM Summary Report
Steve Moody Micro Services, LLC NVLAP Lab No. 102056
2051 Valley View Lane TDSHS License No. 30-0084
Farmers Branch, TX 75234 (Phone 972-241-8460)
Client: Austin Environmental, Inc. Lab Job No.: 0813-08192
Project : Cedarlane, Vacant Bar, 303 College Main, C.S., Texas Report Date: 07/08/2008
Project # : AE08-364 Sample Date : 07/07/2008
Identification : Asbestos, Bulk Sample Analysis
Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116 Page 2 of 2
On 7/8/2008, eighteen (18) bulk material samples were submitted by Paul Dehlinger of Austin Environmental, Inc. for asbestos analysis by PLM/DS. The
PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Sample Number
Client Sample Description / Location
Asbestos Content
06C
HVAC Duct Insulation, Debris Pile Behind Building
None Detected - Insulation
None Detected - Paper/Tar/Foil Wrap
These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual � � n ^
estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These
test results do not imply endorsement by NVLAP or any agency of the U.S. Government. Accredited by the
National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056.
Analyst(s): Jose Ortiz
Lab Manager: Bruce Crabb Approved Signatory:
Lab Director: Steve Moody Approved Signatory:
- — — — — — — — — — — Thank you for choosing Steve Moody Micro Services — — — -
PLM Summary Report
Steve Moody Micro Services, LLC NVLAP Lab No. 102056
2051 Valley View Lane TDSHS License No. 30-0084
Farmers Branch, TX 75234 (Phone 972-241-8460)
Client : Austin Environmental, Inc. Lab Job No.: 08B-08192
Project : Cedarlane, Vacant Bar, 303 College Main, C.S., Texas Report Date: 07/08/2008
Project # : AE08-364 Sample Date: 07/07/2008
Identification : Asbestos, Bulk Sample Analysis
Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116 Page 1 of 2
On 7/8/2008, eighteen (18) bulk material samples were submitted by Paul Dehlinger of Austin Environmental, Inc. for asbestos analysis by PLM/DS. The
PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Sample Number
Client Sample Description / Location
Asbestos Content
01A
Ceiling Tile, Restroom Area
None Detected - Acoustic Tile
O1B
Ceiling Tile, Office Area
None Detected - Acoustic Tile
O1C
Ceiling Tile, Hallway
None Detected - Acoustic Tile
02A
Vinyl Sheet Flooring, Restroom Area
None Detected - Sheet Flooring
65% Chrysotile - Fiber Backing
02B
Vinyl Sheet Flooring, Restroom Area
Not Analyzed - Positive Stop
02C
Vinyl Sheet Flooring, Restroom Area
Not Analyzed - Positive Stop
03A
Floor Tile and Mastic (Black), Main Area, Perimeter
None Detected - Floor Tile
3% Chrysotile - Black Mastic
03B
Floor Tile and Mastic (Black), Main Area, Perimeter
Not Analyzed - Positive Stop
03C
Floor Tile and Mastic (Black), Main Area, Perimeter
Not Analyzed - Positive Stop
04A
Attic Insulation, Back Storage Area
None Detected -Thermal Insulation
04B
Attic Insulation, HVAC Closet
None Detected - Thermal Insulation
04C
Attic Insulation, Hallway to HVAC Closet
None Detected - Thermal Insulation
05A
Drywall Texture, Entrance to Restroom
None Detected - Drywall Material
None Detected - Texture
05B
Drywall Texture, at Water Pipes
None Detected - Drywall Material
None Detected - Texture
05C
Drywall Texture, Entrance to Restroom
None Detected - Drywall Material
None Detected - Paint / Texture
06A
HVAC Duct Insulation, Debris Pile Behind Building
None Detected - Insulation
None Detected - Paper/Tar/Foil Wrap
06B
HVAC Duct Insulation, Debris Pile Behind Building
None Detected - Insulation
None Detected - Paper/Tar/Foil- Wrap