Loading...
HomeMy WebLinkAboutRES2008-02082THIS SET OF DRAWINGS FOR A HOME IS THE COPYRIGHTED PROPERTY OF STYLECRAFT BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL OR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF THE DESIGNERS. PLAN TYPES S = SELECT SERIES W = WAINSCOT WITH SIDING F = MASONRY ON FRONT 3 = MASONRY ON THREE SIDES 4 = MASONRY ON FOUR SIDES G = GOLF CART GARAGE E = ELITE COLLECTION C = COLLEGE HOUSING A = ATTACHED TOWNHOME D = DETACHED TOWNHOME X = DEVELOPMENT Z = CUSTOM HOME FRONT ELEVATION WIC / B'Qg _ _ _ _ _ / Master Bedroom Cr II z'-4•.1 �'-t a I I I vo VC I Country Kitchen M Bath a ag aCg 15'-4•x 12'-a c Bedroom 2 8' CIgg 11'-9'.10'-r I , I d B6fh 2 I j E) Bedroom 3 Bath 2 n•-18•:i$-r g e gcgc 15.6•. 12'.0• - UlEntry laag -- Two -Car Garage e•Ca Building Envelope 57-11• . 32'-11 I I I I I FLOOR PLAN j SHEET INDEX G-1 ICOVER SHEET C-1 ISITE S-1 FOUNDATION S-2 IWALL FRAMING S-3 FLOOR PLAN S-4 DETAILS S-5 JOIST FRAMING S-6 ROOF FRAMING S-7 ROOF S-8 ELEVATIONS E-1 ELECTRICAL P-1 PLUMBING A-1 TRIM/CABINET A-2 FLOORING COMMENTS FRAMED AREA LIVING TOTAL 1073 SF GARAGE 383 SF PORCH 27 SF FRAMED TOTAL 1483 SF m JOB#: 08063 0 z Lu c/-) U ca:� w 0- _> CD CV CN PRE -CON CREATED: AJ 6/10/08 PRE -CON: REVISED: ISSUED: PRINTED: 6/2 7 00 M� w O 17- 0 cyi U r'-, 0 f— SCALE: 1 /8° 11x17 G-1 UON c W/ W/ PUG UP SM001H DOWEL EIN LOx- vIAGIN SU9 Oa GRILL 9" IEX'Sn.vG GRADE REAM. iAPE W CAP TO LEAVE iOJL EDJE E.J.T. t' O END OF RJO Pc OD-faD III I Cwa DISCONTINUE " SvOUyGPPEOWa.is REINF, o U. TX REDwpoD DmDEa D SECTION "DS TMNnNUE REINFORCEMENT OUCH EYYIAY ONE C ` PER l' THICK PAVING =0 PSI X SO. F". MIN. REINF. W/ u3's O 18' O.C.E.W. MID DEP USE — SUPPORTS C SECTION'C' OPoLLMIU OIA DOWEL W/ SLEEVE INfO E%i5i1NG SIpEWMJ( IX RED— WDER B SECTION'Bi3 3/8- Du. WW'EL W/ SLEEVE DRILL INTO EXISIl G CURB a'Xa' euu W/ ♦ /5 RE — A SECTION "A.' D BUILDING LINE d ° ° C a d 4 INSTALL EXPANSION JOINT a ® MID—DRNE IF OVER 45' 0 d d ° PROPERTY LINE ad a 4 °d .a 4" THICK 3000 PjjI CONC. REINFORCE W/BARS ® 18„J/3 O.C.E.W. ° ° WIDTH 0 FIFY SID WALK CITY SIDE WALK IN FIELD . \ v d e MAIL BOX • / ° ° 4. ° A LAYDOWN CURB DETAILS •ONTRACTION JOINT WHEN )RIVE S 16' WIDE I" THICK 3000 PSI CONC. 'EINFQRCE #3 BARS i 18' O.C.E.E.Ww. ;ONTRACTION JOINT VSTALL METAL KEY1"{PY XP. JOINT W/ 3/� DIA. 'LICK DWLS. ® 18 O.C. V/ SLEEVES ONE SIDE RIVERS END DR. SONOMA PHASE- 21BLOCK- 31LOT-16 SOD SCHEDULE NET LOT SQ FOOTAGE 3921 SQ.FT. FRONT SQ FOOTAGE 1807 SQ.FT. BACK SQ FOOTAGE 2114 SQ.FT. Eo C? O 0 L ' �OP E gym^ o r` c o `- � ° � as Np0 yP 3 • hRUU JOB#: 08063 Z Lu () U ry Lu Lu \ a- / cn ry CD CV CV PRE -CON CREATED: Al 6/10/08 PRE -CON: REVISED: ISSUED: PRINTED: 6/2 7 Q w O cn m O r- SCALE: — 1"-20' C-1 PREPARED 10/17/08, 8:05:01 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/16/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 2720 RIVERS END DR SUBDIV: SONOMA PH 2 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 578700-0203-0160 APPL NUMBER: 08-00002082 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/22/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00 7/22/08 AP July 22, 2008 9:35:55 AM ccourt. Strings up. Slab ground installed. B115 01 8/15/08 RH BLDG, FRAMING TIME: 17:00 8/15/08 AE August 15, 2008 11:24:50 AM ccourt. Complete elect. rough notes. By insulation. B130 01 8/19/08 RH BLDG, INSULATION TIME: 17:00 8/19/08 AP August 19, 2008 8:09:22 AM glsouth. B132 01 8/22/08 RH BLDG, SHEETROCK FASTENER TIME: 17:00 8/22/08 AP August 22, 2008 12:03:18 PM glsouth. B125 01 10/16/08 B_I BLDG, FINAL TIME: 17:00 October 16, 2008 2:33:19 PM glsouth. ----------------------------------- COMMENTS AND NOTES -------------------------------------- t. V o U� 1 V� Aug.14. 2008 1,20PM''- Stylecraft Builders, Inc. No. 5184 P, 3 "Shielding & Protecting Homes Against Pests" Renewable 5 Year Subterranean Termite Retreatment Agreement (Does not cover nuy other species of Termites) This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph). CustomName Date&b Billing Name if different ''9 b ly' 5 'r". Street Address of treated struchuo (',S ;2 --- 77,8 City State Zip Code Uome .Phone Work Phone Type of Treatment Partial _Bait _YPre-'Neat Treatment for: 1 Prevention Control of Subterranean Termites Notes: Billing Address if different City State Zip Code Initial Termite Cost $ Additional Renewals )Paid Other Tax Cash_Check# Total $ Payment 5 Balance $ Credit Card: Type Exp. Date Card Noamber 5 Y= Fpbterranean Termite Retreatment Guarantee: RP Lee Termite and Pest Control will retreat the structure for Subterranean Termites at no cost to the customer, if an infestation of Subterranean Termites is found, as long as the original treatment is paid in full and the customer is current on their yearly renewals. This Agreement will expire in one (1) year unless the customer elects to pay the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termite and Pest Cootrol may approve additional warranty years after the five (5) years with an additional increase in the yearly warranty fee. The $uarauteo dots not cover any damages to the structure or contents of the customer. The customer agrees to control allconducive conditions that may cause reinfestation. If the structure is modified, added on to, altered, or if the soil treatment around the structure is removed the customer must contact RP Lee Termite and Pest Control and pay for additional treatment in order to keep the guarantee in effect if the customer does not pay for additional treatment the retreatment guarantee can be cancelled. Cif Renewal Fee; Customer may elect to rmew the retreatment guarantee for additional years. Tire renewal fee is 53(j�lus tat. The renewal fee is due on or before the annual anmivcnsary date or paid $ %+ plus tax every third (3) month with inspection. Maintaining the Guarantee: The customer agrees to correct all condusivc conditions, at owner's expense, as they exist or as they occur in the future in order for the guarantee not to be cancelled. Customer will make the structure available for inspections and treatments as requested by RP Lee Termite and Pest Control. Reinspection: RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times RP Lee Termite and Pest Control deems necessary. RP Lee Termite and Post Control recommends that the customer call and set up an annual inspec- tion at the time of customers yearly renewal. n f r• This agreement may be transferred to a new owner with the payment of a transfer fee of $� , copy Of the Wood Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest Control. TbiA Subterranean Termite Retreatment Guarantee does not urevent and is not intended to control ether farm�gf fig; (Drywood. Formosan. etc.). Wood Boring Be_PRes. Carpenter Agtg Carpenter Bees, Wood Rot . FunEus. Decay. or any other wood dent *g insects or organisms. ArMmItm In the event of any dispute ansiz g out of this agreement or any other services performed or not performed the parties above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration Association, Tbc Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final, binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration Act. Limitation of Liability: Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled up in certain areas around the home, drill holes may need to be made in floor mverfngs such as file or linoleum or in cabinets next to pipe areas, and holes may need to be cut in walls.. Customer agrees not to hold RP Lee Termite and Pest Control liable for these damages, or treatment techniques, or other damages that may occur during treatment. Agreement: This Agreement shall be the entire agreement between customer and RP LeeTermitc and Pest Control. If any part of this agreement is found to be invalid it shall not affect the validity of any other part of the Agreement. We are Licensed by h . Rtrn oral P at .ontrol Board - 33-C.uad lone. Suite I-530 Austin, TX 78701 512-305-8250 rev le t7' L RP Lee Termite cst Control Ccrt. Apl n ClEstomcr T6aturc Date f Xt-- Aug, 14. 2008 1;20PM Stylecraft Builders, Inc. No, 5184 P. 2 New Construction Subterranean Ter mlto urro �,ptc�at Nu. VIITos: ) (axp. tOfJtf1406] Soil Treatment Record This torn tc cOtnp-Wsod by rho llconrod P= Control Con slum Akvmno yurm) Wr Uz a randdadirn c6 Munn is oattmalod W aM.Mpo tb minutoi Gor raspneio: Litludinp �c'Lcio tiu rovi�xiirj uiiniet�ri�s. �osictt iy mowed d*Un brmtime L D �Cp rwi wlkw�tUWrMMMo this sdwma On, a moot MV qWuttats m =010to utr '"Vo agl000nW A a =aWjtrald CUB Congo, L ? aUAW. ''t:o ti0n 24 GFH 2O0 8�od(bI(9) to roe �hnt the spas for 1 !!? gtsttrod ati<tfq+oaa meat bo boo W tormoo huairds. 7hi; fnttxtn:6oa Coliaylon raR� tree the buldcr fu abttity Owl an nutttaaizod pwl Carttrv! canparW pofivmad AS tattttbod aeat=U for tacrWIM. and that otC UpHdW gu tatsoas Out Un=d area apanst hdawta4or: for 09ro yaar. Bulldon. Aalli Gonitnt oeettprtrtioa. tt='tf1ay61ettleta� t101Sf0:7lNar4 end 1-tt� �i a raClttd VS Vd3UriDn7 iGr(j�OGili4 hua�oe ..iG ww Ow RAwm�9vtt CoitXx6i1. 17hs inldnntflaet ie rKat e-,&;dnm d C X15dw" _ IlaasropOrtIr. itdttt1WtoriniQ=11OPutPuaxL=wIngbWlduronNrop]l:att(nawrCWuthurlaorCUX"WhM+onttoat W1[for pr4voatronanublarrynean tormita It1tYiL7UiWt In ipQdflod by tho hAdor, erotrnoot, or rnquitud by tho ldnduq ivahitact, FMA. or VA. AR comracts 101 sort OOO are boiMm tha Nast 09.'ttrd oporator and bultdor, uniocL 9taitlyd othanvha0, $oetlon 1. Genvrat lntarnudan (rraatauj Ccilipmy ladfufrmlQn) Company Namo:— GotnptsnyAAdroao / o City cofrtpatty euunar>; ! toortca NO. Company Ptaartta No, - _ r� 7 � `' �' � ?✓ FHWA Casa No. (If any) — Svsilon 21 Builder 11kXONalon C=Pany Rlsona No. $aC1IQ4II: propor3y tntwltiaUott 6dCutJon Ci*UvGhzO (a)iloulvd (31rool A4.kgsa or Log&] Dwdpion. C4..5tatu Und;Zip) C •� TX 770 %'Pd Of Gonwadlon (!,taro U14n tunaWX my W Ohocltoo) � Slab I--. �dbomant � Crathi MP to Dapth of i ootiny: t slain ��. 1AW de �� .... Typo c'f Fill 5ociltul q;'jtcortstorrtlatnmotttion Dstv(a) otTrvaLntttil(a) Brand Natar! OI f'mtkrt(a) tJaact ..—r...�i�.btf* s�r�L � --,� CPA Replatradoa No. p Approxlmolo VinW idiu Sdullun'n ApproXlrtloto Vzo of Tmalmont Arno: t;t{ tk � � I Llnoar 1k � _ L1nc;u C, of &toratuy Yo'�fa AWQxbnato Tutu! OdDAs d Sa Waq ApAod —I&OA1 Was trootMUM rAM90ted oft uxlcrw Yes i No SeralcaxAgrOtxtttxttAtr o7 Yei ( No Noto. Some 4Wo fawn roquiro amvloo aprosmontu to bo isatmi Thiu fs, raf dvoo not ptoumPt stata la,v. At=!rWnIs hilxus trt ApW!lCatatis} J CdtfwAllon NO.(U rogtdrad by Vzta unary cR fg-/6 7 nto appUegtor has used a product in &rWtdtUrq wltil qta preduot label and stalo mgtilraat nm htl trallawrA raalcvG:s ono 00thOJ4 a5oaf t:ornpty wkh &p And WOW r4pvhttitui8. _1__1? I AutWzod Vilmatwu lY wn wo^-+bcno f�tro udrnr. Form NpCA 0" may stlt bo uW mstat h v1rrkW.1Uw1r 60 p.ntnatn 04 U.,'X. um 1111ta HUD-HFCA-00Li1 (tsW7.003) Aug.14. 2008 1:20PM Stylecraft Builders, Inc, No. 5184 P. 4 SUBTERRANEAN TERMITE PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATE Licensed and regulated under the Texas Structural Pest Control Act RP LEE TERMITE & PEST CONTROL PO Box 9423 - College Statlon, TX 77842 • (972) 690-8622 • TPCL #11486 - CUSTOMER INFOR TON: Name: emgr—r Phone #1: Phone #2: Address: O ]give45 A-i City. .S State: �_ Zip Code: 1j Location to be Treated: For ell trealments there will be a diagram showIng exactly what will ba treated prior to the beginning of treatmert Review the pesticide label provided toyouatthistime for minimum treatment standards. Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer Information sheet for further Information, If you have any questions, contact the pest control company or the Texas Structural Pest Control Board, R0. Box 1927, Austin, TX 78767.1927. Telephone number (512) 305.8250. Before conducting a termite preGor struction treatment, the company will present a complete diagram of the structure Including constructlon details. When construction prevents performance of a full treatment, In accordance with a bid for full treatment, any change to a partial treatment by the company providing the treatment will be permitted 9 the owner of the structure or the person in charge of the construction and the certified applicator for the pest control company sign a statement attesting to the construction oonditions. The agreement must be attached to the contract with an amended diagram showing the exact areas to be treated. Coples must be sent to the owner of the property within seven days of the application. notes: eadwemae- �J¢e-rd,"0,n wo ear Ale f DaStd !� a 7e �y� ram+ rhis .FI .�#a o v ►� Type of treatment proposed: (check all that apply): ❑ Full Partial )0 Wood ❑ Bait ❑ Commercial g61ngle Family Total square feet to be treated: %* . Total linear feet to be treated: 3Z5 , Approximate measurements of structures) to be treated: A label of Z&ga 411fX termiticide(s) is attached. The percentage of the termiticide(s) to be applied at this location Is %. Estimated amount of termiticide to be applied: �, 65 gallon(s). THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED ON BACK (SPCBID4). THE BOARD APPROVED SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT SERVICE Complete details of warrarrly (if any) including time period of warranty, renewal options and Cost, and obligatlons of the Contracting parties is attached If the warranty does not include the entire structure treated, the areas included in the warranty are (specify): A oansum fonmatbn sheet Is'also attached. U e/ rgnature o o ch n Printed Name Data 81glitature of Cn mar Verifying Receipt of This Document Data IN SM U6.2 • 01M7 White Copy - Swico Proridar vmlaw Copy - Customer Fam oasgW mud Reed by Sw&zMa* Cdreu*imns i-SWMEM, aiM TX 2007 Service Treatment Invoice Route: U Map Code. Start TbM. mlpm Inuish um: i mlpm type of sv_ ce: cilia Regular Follow Up One Time Charity Service Address Name: -' i 7 Address: 79716Le i t1r,15 t'k,,A City: 5 TX :7:= Phone: F �1 1;YJL'I j1 I nUTRIL i Date: Appoint. Time: Az am+pm Frequency: 1Dk BM Q S Y Structure: Lab wl PIB Combo Peu: Dog (a} Cats) Bird(6) Fish Cost of Service $ / - Tax $ "Total flue S Payment S Balance PEST PROBLEMS: r lJgle DIRECTIONS I INSTRUCTIONS: EQUIP. METH. LOCATION(S) WOOD DESTROYING 1NSEC15 GENERALPESTS FLEAS a 1 t i,m-mr, mmoreintum Billing: PRODUCT QTY TARGET PEST(S) Payment by: Cash a Check ❑ # Credit Card ❑ PAYMENT DUE UPON RECEIPT TermiderSC-Fipromil.06% SubterrancanTermhes,Ants SizeerTardk Posted TermklorSOW-Ptlpreoil A611 subterranean urmiles. Size orllrnk Posted P1ora-carp.DisodiomHclaborate'Iblrahydate50% sabtcrumeaNFornimamiDrywoodYermllea,Corpenterhnts,Bcettes, Posted i InvaderHPli-Baygon 1% Demon WP-Cyano-PhcndxyphenA Diraetkycyleydepropauecs osylate1% Tempo UI1ra t4'P-Cyllmdaln .d2VA (Rest) (gem. surface spray, spot, mist, crack & crevice) lllvar EZ Btlenlhrin .2% Maxfafvc4lydranuthyion 1%2.15% Cykkk CSC)futhrin AS% Phantun .5% Carpenter Ants„ SpideM Crickets, Millipedes, Bcctles,'Urmitm Cockroaches, hltllipedes, Sowbugs,Flies, 7lcks, Slosquftoa, Pillbegs, SWerrnh, Bees, Ants, Carpenter Ants, Scorplons, Spiders. Amts(Eseept Pharaoh),Cockroae3es, Crickets, B.arwigs, b116ipedes, Blics, IWIFiles, [kvd s, Pillbugs, Silverfish, Spiders, Casts, Hornets..Vaspa,YdIo%-Jackets. Ants, CeedpotIM Cockroaches, Crickets, Crassboppers, Scurpioms,'kiss, SSPverliuh, Spiders. Pharaoh Ants, Crickets, Carpenter Amtsy Lg, Roaches, Variety olAnts. Spiders, Scmrpions, Ants; CarpmterAnts, Carpenter Ilees, Roaches, Crlckals, Silverlisb. Phamb Ants, Variety or Ants, Roaches. Tengaud-PernetliWa.s L Fleas,'ndes,Ants, Ceallpedes, CarpenterAmtc, Bees, Wasps, Corpester Bets, Cockroaches, Crickets, Flies, Earwigs, h11111pedes, Beetles, Pillbugs. Suspend SGDcllanetmrin 4.75 % (REST) Fleas, Bees, Merles, Reaches, Crkkeh6 L1cy bliee, Seorpious,'l kka, Wasps. N}guard-ldcthyietaoxy 18%(REST) rCR-Growth ReVIatw-Flees, Roaches. Crkkeis,FlplogInsects, Stored Product Peals. Excite RP"brin A5% Flom , Fastrao-Bnmetbatin AI% Alice, Rodents, Rat& Halt Station-IargdSmall Gime Boartis Mice, Rodents, Rats, Bug Monitors. Pro-Cosdrol Ples Pyretbrbna .50% Houseflies, Mosquitos, Moths, Fleas, VP'aaps, Hernets,7icks, Cockroaches. tiasteWineBlfeathrin .ti6% Spidni%Auts, Roaches, Silverfish, Earwlga, Fleas,Suorpions EaulMent: A -Compressed Sprayer P-Power Sprayer B-Bait Dispenser BS-Bait Station BY -Dail Trap D-Acm9oL Can G-Gluo Board H-Hand Duster S-Spreader F-Fogger "I-Foamer AC-Aclisol unit Otber Loca low 1-Kildieo 2-Dalh(s) 3-Bedrooms 4-Dining Room 5-Utility d-Storage 7-CornmooAreas &Garage 9-Perimeter of Structure 10-Attic 11-Yard MUnderHarne 13-Iftchouse 1"Mce 1S-Expowd Wood 2' up from Slab Other Method of Tym(ments: CC -Crack & Greviue SS -Sub -Slab Injection VT -Void Treatment BP -But Placement 8S-Broadcast Spray PWPerinWter Barrier BV-Brick Venire WT-Wood Trcalment PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations.- Ventilate rooms after treatment. Keep pets away until pesticides have dried. Licenced by the Texas Department of Agriculture Structural Pest Control Service - P.O. Box 12847 • Austin, TX 78711 •512-30"250 SERVICE TECHNICIAN: yA,,att) CUSTOMER SIGNATURE: DATE: , 'q 1�iS 01 ease review the Customer Information on the atherside oflavoloe P.O. Box 9423 • Cotiege Station, TX 77842 • (979) 694-8622 • Fax (979) 690-,8840 WF1057144 / 001 City of CollQge Station ._ PAGE 1 REQ. DATE: 07/11/08 07/11/08 15:18:50 LOCATION: 2720 RIVERS END DR LOC ID: 211872 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT- SET READY SCHED START: 07/11/08 SCHED COMPLETION: 07/11/08 ******************************************************************************** JOB ORDER RESULT COMMENTS BUILDING PERMIT CITY OF COLLEGE STATION ; 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ------------------------------------------------------------------`---------- Application Number . . . . . 08-00002082 Date 7/10/08 Application pin number . . . 656962 Property Address . . . . . . 2720 RIVERS END DR Property ID: 578700-0203-0160 R #: R307387 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SONOMA PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY CLUSTER DEV Application valuation . . . . 70818 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 13.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 19.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT o GLAZING 14.00 GLAZING U-FACTOR .53 HEATED AREA 1073.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .35 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 427.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc AC Permit pin number 586487 Permit Fee . . . . 344.00 Plan Check Fee .00 Issue Date . . . . 7/10/08 Valuation . . . . 70818 Expiration Date . . 1/06/09 Z; -------------------------------------------- ---- BUILDING DEPT REPRESENTATIVE: ------------ APPLICANT:✓i11 iWnw.00* BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . Application pin number Qty Unit Charge Per 21.00 4.0000 THOU Page 08-00002082 Date 656962 BASE FEE BLDG, VAL 50001-100000 Special Notes and Comments *Engineered Bracing Methods Used To Meet Windbracing Requirements. *GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. *PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY BEING ELEVATED A MINIMUM OF 18" ABOVE FLOOR LEVEL. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE,MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL BUILDING DE APPLICANT: 2 7/10/08 Extension 260.00 84.00 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00002082 Application pin number . . . 656962 Page 3 Date 7/10/08 Special Notes and Comments RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 15% the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 * THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (20-) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE ---� "-w- -,&------------ BUILDING DEPT REPRESENTATIVE:— �••�+' : �i/L/ � �lsi/ BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00002082 Date 7/10/08 Application pin number . . . 656962 ---------------------------------------------------------------------------- Special Notes and Comments *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN -------------------------------------------`111------- ----------- BUILDING DEPT REPRESENTATIVE: __&AA 1L 11U. APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00002082 Date 7/10/08 Application pin number . . . 656962 ---------------------------------------------------------------------------- Special Notes and Comments ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . IMPACT FEE AREA 97-01 98.39 SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited Due ------------------------------ ----------------- Permit Fee Total 344.00 344.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 848.39 848.39 .00 .00 Grand Total 1192.39 1192.39 .00 .00 -------------------------------------------- BUILDING DEPT REPRESENTATIVE: 4 APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00002083 Date 7/10/08 Application pin number . . . 790803 Property Address . . . . . . 2720 RIVERS END DR Property ID: 578700-0203-0160 R #: R307387 Application type description TEMP POLE Subdivision Name . . . . . . SONOMA PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY CLUSTER DEV Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 586495 Permit Fee . . . . 20.00 Issue Date . . . . 7/10/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Fee summary Charged ----------------- Paid Credited Due ---------- Permit Fee Total 20.00 ------------------------------ 20.00 .00 .00 Grand Total 20.00 20.00 .00 .00 ---A -- -'f -------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: �% FFOro.:lce Use Only APPLICATION FOR BUILDING PERMIT DATE: �•&2= 09RCCREG 1101 TEXAS AVENUE �. COLLEGE STATION, TX 77840 APPLICATION # CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX TEMP POLE # Planning c-Dme47pmrnt Smires WWW.CSTX.GOV ADDRESS/LOCATION: _ c,79 0 r-S Erid LOT �BLOCK -3'/SUBDIVISION SC ►1 d M CL SEC/PH— BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 127 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 127 CONTACT PERSON FOR REVIEW COMMENTS: JOSEPH SAUCIER PHONE: 690-1222 ext. 127 FAX: 690-0348 EMAIL: isaucier(a)-stylecraft-builders.com ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbinq HVAC: Control Temp GOOD CENTS (Residential only): No ACCESSORY/STORAGE LOCATION NflP ADDITION MOVINGAL DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION DUPLEX (Landscape Plans) REMODEURENOVATION* TENT/CANOPY DESCRIPTION OF,. PROPOSED USE: WORK: Conventional Framing c R$,3q Single Family Residence 0— WALL BRACING METHOD: PRESCRIPTIVE 0 APA PORTAL FRAME W/ CSPS ❑ ENGINEERED HOMEOWNER ASSOC IATIO N/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ 70 919 ✓ TOTAL AREA: I `f S 3*HEATED AREA: 10730 (Cost of Labor and Materials) X PUBLIC SEWER SEPTIC/TREATMENT SYSTEM QX SEWER TAP: 4" 1 SIZE QX WATER TAP: %11 NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry JILC OTHER TAP: FOUNDATION TYPE: Slab on Grade SIZE X TEMP POLE ROOF TYPE: Composition / A G RAGE ��E: SINGLE DOUBLE ® TRIPLE ATTACHED �X TA D CARPORT E SI ATURE OF APPLICANT: ( 00 For St lecraft *If proposed work involves new commercial constr I nor fac de improvement/renovations to an existing red. commercial property, building elevations are requi ♦♦0000e00000000s0000000000000000♦ oeosoos000000000eeooes000e Official Use Only `-6 7 7-0h GA9.4A jp W/ 14 Plans Examiner Eh91'0 "4W .9/&4c41V Zoning Official 0ents: E or NO Fire Marshall .rzergy Code Compliance Information % Glazing of exterior walls 1 % Insulation R value of exterior walls R13 I--- Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor s ti- R value of ductwork ;A/C SEER Rating Protection Against Subterranean Termites ❑ Chemical Termiticide Treatment (Soil Treatment) Chemical Termiticide Treatment (Fielc ❑ Physical Barriers ❑ Other .35 .53 R6 I,/ 13 -' i Appiiect W ooct 1 reatment) t r *Verification of Application shall be submitted to the City of College*Station Building Department prior to issuance of the Certificate of Occupancy: _`�s a5�t,9�yw yJ PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning dDcvelopmentSnvictt COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# O _ DATE: BUILDING ADDRESS: I. Foundation Require Minimum City Foundation Standard --- A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated 11. Framin : Floor, Wall, Ceiling and Roof Requirements N K N O A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck 6WOK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracin if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. OK K PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch Where IV. Fireplace Requirements K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location CITY OF COLLEGE STATION Planning d Development Smut PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N K Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER DATE Permit # Permit Date AntREScheck Software Version 3.7.3 Compliance Certificate Project Title: Plan # 1073 AL Report Date: 06/30/08 Data filename: S:\ACAD\Archived\Old REScheck\1073 2720 Rivers End.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 14% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: 2720 Rivers End StyleCraft Builders Inc. College Station, TX 77845 4090 State Highway 6 South Permit Date: 6/30/08 College Station, TX 77845 979-690-1222 Compliance:, Passes -M xiw` mum UAL-469 Yau-H- ome UA''J420rJ14:4% Betti—r Than C6dd'(UA)'1''I Maximum SHGC: 0.40Your0.40 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0' Air Conditioner 2: Electric Central Air: 13 SEER Furnace 2: Forced Hot Air: 80 AFUE 822 30.0 0.0 29 251 19.0 0.0 13 1132 13.0 0.0 77 135 0.670 90 38 0.500 19 18 0.440 8 177 0.0 184 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. ThP431oPOsed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the m ndato rI e s ed in the REScheck Inspection Checklis 5'1 JLJFCZ AkiT _-7 I I L18 Builder/Designer Company Name Date Project Notes: Previously saved project information: Spec 2720 Rivers End College Station, TX, 77845 Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 Plan # 1073 AL Page 1 of 1