HomeMy WebLinkAboutRES2008-02067, 08-2068T�
/ ,� i
!, %I -�
WF1056162 / 001 City of College Station PAGE 1
E�
REQ. DATE: 07/09/08 07/09/08 14:14:32
LOCATION: 1104 HARRISONBURG LN LOC ID: 202674
REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 07/09/08 SCHED COMPLETION: 07/09/08
JOB ORDER RESULT COM=S
PREPARED 8/20/09, 8:02:49 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/19/09
------------------------------------------------------------------------------------------------
ADDRESS . : 1104 HARRISONBURG LN SUBDIV: SHENANDOAH PH 14
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER ED FROEHLING BUILDER INC PHONE
PARCEL 569500-1441-0140
APPL NUMBER: 08-00002067 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 8/08/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00
8/08/08 AP August 8, 2008 9:30:19 AM glsouth.
B120 01 8/15/08 OC BLDG, FRAMING -PARTIAL TIME: 17:00
f
" 8/15/08 AP August 15, 2008 10:07:08 AM bboerboom.
APA inspection.
13115 01 10/17/08 RH BLDG, FRAMING TIME: 17:00
10/17/08 AE October 16, 2008 2:05:32 PM glsouth.
Double joist at attic access. Connect plumbing vent pipes.
Bath fan ducts need to be vented at soffits.
B130 01 10/24/08 OC BLDG, INSULATION TIME: 17:00
10/24/08 AP October 23, 2008 3:52:17 PM glsouth.
B125 01 8/19/09 BI BLDG, FINAL TIME: 17:00
- A%- Pf August 19, 2009 4:41:14 PM khejny.
----------------------------------- CONTINUED ONTO NEXT PAGE -------------------------------------
�ylLQ,�L
�J
08/19/2009 16:19 9797740565 ED FROEHLING BUILDER
ACE VEST CONTROL
T.P.C.L. # 7120 PT '
PO )SOX 4474
ERYAN, TX 77805
(979) 823-7777
(979) 774-4736
TIry
ICAA ..0
The ;Following property _ U ] ,,_ SONBUP-G LN.
built . Kk0EHLRjg1Romq State of Texas
County of 9RAZ0S t11e city of COLLEGE S ANION
Mailing Address SAIV[E ._ Zip code 7784$
was treated for subterranean termites on this day ,AUGUST' 07, 2005attd has met
with approval. Cost of initial treatment, 238.58 is payable uponcompletion of work,
The treatment is guaranteed for 12 months from the date of treatment. Therea&r, this.
contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection
and renewal fee of $ 120 plus tax, for a period of (see attached letter) If
at any time during this contract a reinfestatiou of subterranean termites should occur, the
above said property will be treated at no additional cost to the owner. ACE PEST
CONTROL. does not accept any liability for any subterranean termite damage repair.
Failure to pay the annual renewal fee wig thirty days after the inspection date shall be
construed as a cancellation of this contract. Any alteration or addition to the foundation
of the above described property without proper smite treatment by ACE PEST
CONTROL Services shall nullify this contract.
Liccnscd and RegulaW by the
Texas Department orAgiculftn,,
SMJctUTW Pftt Control Service,
PO Box 12847, Austin, Texas 78711.2847
(512)305-82$0
PAGE 02/03
08/19/2009 16:19 9797740565 ED FROEHLING BUILDER
PAGE 03/03
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
.ration to b���
FR06HLING HOMES
1104 kRMSONSURG LN.
([4� 1`633
F� y �jng• BRA NOFIZOntallPer(meterBsam_)0
ABEL FOR ANY OTHER PESTICOE MOMENDEP OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ApM
LUDINp AREA COVERED, TAME PERIOD or WARRAWTY, RENEWAL OMONSAND COST. 7 FIE OBLIGATIONS OF THE PEST CONTROL OPEFU►TOR It7 RE
EAT FOR T UMM- INFESTATIONS OR REPAIR DAMAr.E CAUSED 6Y TERM,, INFESTATION$ WRWiW THE WARRANII PERIOp, AND TI E CONDITION$ THAT
OLD DEVELOP ASA RESULT OF THC OWNER'$ ACTION oR lNACTIQN THAT WOULD VOID THE WARRANTY WA8 ALSO " ",ATTACHED.DT14
largos for pre -treat:
)TES: Annual re-newal.
$23108'
120&00
32139 .PT
Ce 6r TaehlrkcIm SPCS been,, N
8 r"8
SN29 PT
BUILDING PERMIT
CITY OF ICOLL19GE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00002067 Date 7/09/08
Application pin number . . . 021085
Property Address . . . . . . 1104 HARRISONBURG LN
Property ID: 569500-1441-0140
R #: R302536
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 146916
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDER INC ED FROEHLING BUILDERS
3887 HIGH LONESOME 3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . A/C SEER RATING 13.00
CEILING 1 R VAL. (FLAT) 30.00
CEILING 2 R VAL-NO ATTIC 19.00
DUCT R VALUE 6.00
EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID N/A
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
Is GLAZING 10.94
GLAZING U-FACTOR .64
HEATED AREA 2226.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.50
NUMBER OF BEDROOMS 4.00
EXTERIOR WALL INSUL R VAL 13.00
GLAZING SHGC .40
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 427.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 586016
Permit Fee . . . . 601.00 Plan Check Fee .00
Issue Date . . . . 7/09/08 Valuation . . . . 146916
Expiration Date 1/05/09 -
BUILDING DEPT REPRESEU ATIVE: —
APPLICANT:
BUILDING PERMIT
CITY OF,COLLI�GE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number .
Application pin number
Qty Unit Charge Per
47.00 3.0000 THOU
08-00002067
021085
BASE FEE
BLDG, VAL 100001-500000
Page 2
Date 7/09/08
Extension
460.00
141.00
Special Notes and Comments
-Add Kitchen Island GFI
-Add 1st Floor Smoke Detector
-Narrow Wall Bracing Fully Sheathed
*IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
*ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Divertejto an Approved Point of
--------------------------------------------� ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF-COLL9GE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00002067
Application pin number . . . 021085
Page 3
Date 7/09/08
Special Notes and Comments
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR
*ATTACHED GARAGES SHALL HAVE
PENETRATIONS SEALED
*Assure Proper GFI Locations,
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT
BE ELEVATED TO ALLOW FOR ATTIC
*Wall and Ceiling Insulation
If Wall to Window Ratio is of
R-13 and R-30, above 15% the
GARAGE DOOR HEADER
ALL TOP PLATE AND HEADER
Including One Within 25' Of
AND/OR ACCESS MAY HAVE TO
INSULATION
are as follows respectively.
to 1501 the Values Shall be
Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
* THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED
AT THE PROPERTY LINE IS 25' AND MINIMI----,
WIDTH
OF 12'
-------------------------------------------•r-----------BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF-COLL2GE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00002067
Application pin number . . . 021085
Page 4
Date 7/09/08
Special Notes and Comments
*DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN
2006 IRC
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR
HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE
UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR
COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL
BE PERFORMED PRIOR TO FRAMING INSPECTION.
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE
LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIEUT OF ALL GLAZED
--------------------------------------------- ----� - ----------
BUILDING DEPT REPRESENTATIVE: -
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number . . . . . 08-00002067 Date 7/09/08
Application pin number . . . 021085
----------------------------------------------------------------------------
Special Notes and Comments
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 200-o TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2006
IRC)
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
*GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
*PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR
CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY
BEING ELEVATED A MINIMUM OF 18" ABOVE FLOOR LEVEL.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 601.00 601.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 750.00 750 0 .00 _ .00
-----------------------------------------------/-------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF -COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Page 6
Application Number . . . . . 08-00002067 Date 7/09/08
Application pin number . . . 021085
Grand Total 1351.00 1351.00 .00 .00
---------------------------------------- ---- -----� ---------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF -COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 08-00002068 Date 7/09/08
Application pin number . . . 103340
Property Address . . . . . . 1104 HARRISONBURG LN
Property ID: 569500-1441-0140
R #: R302536
Application type description TEMP POLE
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
ED FROEHLING BUILDER INC
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
3887 HIGH LONESOME RD
COLLEGE STATION
TX 778459443
COLLEGE STATION
TX 77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . . .
TEMP POLE
PERMIT
Additional desc . .
GS
Permit pin number .
586032
Permit Fee . . . .
20.00
Issue Date . . . .
7/09/08
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
------------------------------------------------/j_-- ®- ----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: �
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
(*hr4" COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d Developmrnt Services
WWW.CSTX.GOV
�f
DATE: /� TRCC REG IS61
APPLICATION #
TEMP POLE #a o&69
ADDRESS/LOCATION:, 4 >.
LOT ! BLOCK *�SUBDIVISION �'�- (.� AN'DO�� SEC/PH 14
BUSINESS/OWNER NAME:
PHONE:
CONTRACTOR/HOME0INNER:'" ��T�
u�� r J, � ` HONE: -77b
CONTACT PERSON FOR REVIEW COMMENTS: �Af�1 PHONE:
FAX: - _-7-74 - - c�,5co95-
EMAIL:
ELECTRICIAN: 0
PLUMBER:---rMLPL' S
HVAC: tNrlo\k-rN'E
GOOD CENTS (Residential only):
ACCESSORY/STORAGE,
MOVING
RE -ROOF
ADDITION .-v
EW CONSTRUCTION*
SHELL ONLY
DEMOLITION (ASBESTOS SURVEY)
PORTABLE STORAGE (RESIDENTIAL)
SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED)
PORTABLE STORAGE (NON-RESIDENTIAL)
SWIMMING POOL
LOCATION '*.
El
REMODEURENOVATION*
DESCRIPTION OF WORK:
PROPOSED USE: �Jth�Ca►I�111..�i
•
STRUCTURE USE:
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TA ) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 14<e;G t(e t� TOTAL AREA: 'Z7Z3 HEATED AREA: rLZ�ZLP
(Cost of Labor and Materials)
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
EWER TAP:
&?'WATER TAP:
OTHER TAP:
9TEMP POLE
GARAGE TYPE:
4It
SIZE
31411
SIZE
NUMBER OF BEDROOMS: 4
NUMBER OF BATHROOMS: 2.112
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:c Y�
FOUNDATION TYPE: ':bLAEPb es 4A11��1�C'
SIZE `
ROOF TYPE: c6M�j tTi Q jV
SINGLE OUBLE G21 TRIPLE a
ATTACHED DETACHED F_� CARPORT F]
SIGNATURE OF APPLICANT: Y
*If proposed work involves new commerci nstr on or facade im nts/renovations to an existing
commercial property, building elevations are required.
Official Use Only
S�ai RS Plans Examiner
-- ttl�a GFr
C nts:
Y S r NO
Zoning Official
F"-Typc, x GAn.'Oye Ce4le'y ! 6Ade ,to ck-
V'4 rkoo- (,."; J awj -vf "/lp F
Energy Code Compliance Information
% Glazing of exterjor,w,all,s
Insufatio6R value of exterior"W'a'fis"
Insula.tion:R valu,e of ceiling I (flat areas)
Insulation R'Valbe- of ceiling 2 (vaulted dr eds/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
(.0
j 5 �
Protection Against Subterranean Termites
9/Chemical Termiticide Treatment (Soil Treatment),
El Chemical Termit.i,cide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers"
0 Other
Verification ofAplilication shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
a
PLAN REVIEW
(*f/q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# _ aO DATE:
BUILDING ADDRESS:
I. Foundation Requirements- Minimum City Foundation Standards
N A410 K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
O
E.
Header sizes indicated on plans
N K
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four (24J inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
OK
N K
PLAN REVIEW
(*//4" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning &DevelopmentServica COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NOOK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N K
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
(*t/q"
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
NAJOK
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/ K
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N K
Maximum drive width for residence is 25' combined for circular and 12' minimum for —single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N K
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
P A S EXAMINER
DATE
Jun. IS. 2008 10:31AM McClure & Browne.Eng/Surveying, No.4319 P. 2/2
(:I1`5I-,'-
htaffrPE'B,BR AWEEVSIAQSP/W91SU�4EiWC>sAC•>mfYwobutfi" mt?xv, C40P S}b,4w,, Texas7700, )Yjam"
Lot 14 51*Ck 41.4wq
Scale:
1 " - 20'
R
R
LM- TABLE ��
UNE SEARING DISTANCE f
U N 45-26*36" E 43.51'
L2 N 74'51'10' W 24.23'
CURVE TABLE
CURVE DELTA RADIUS LENGTH CHORD_ SRG,
Ct 6119'57' 5D.00' 53.52' N 16V6'34` E
C2 60'00'00' 50.00' 52.36' S 15'26'36` W
0
Harrisonburg Lone
50' R.O.W. N 27' Pavement
I/o% 6893, Pg. 105
f
0
I Proposed I N
Driveway
L
9.5
7.5'
I I
I
I
d
s.L.
I
x�
A
_v
U. 0_
pp�,cWp
J �`N
I
I Z o
7
�
I
I
g 5'
i
Note: Building Setback Linea per
City of College Station Unl
Development Ordinance2617
�.._ .. _,._.. —.._.. o
10' P.U.E.-T
5 4528'W' W — 49.38'
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\l 102WB.rck
TITLE: 1104 HARRISONBURG LANE
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 06/ 12/08
DATE OF PLANS: 3/10/07
PROJECT INFORMATION:
Spec Home
Lot 14 Block 41, Shenandoah Phase 14
COMPANY INFORMATION:
Ed Froehling Builder, Inc
3887 High Lonesome Road
College Station, TX 77845
NOTES:
Narrow Nurse
COMPLIANCE: Passes
Maximum UA = 813
Your Home UA = 664
18.3% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Front
Projection factor: 0.09
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Left Side
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
1136
30.0
0.0
40
1090
30.0
0.0
38
320
13.0
0.0
18
64
0.640 41
38
262 13.0 0.0
29
0.400 15
19
0.640 19
/I
t_
Projection factor: 0.09
Wall 3: Wood Frame, 16" o.c.
320
13.0 0.0
16
Window 3: Metal Frame:Double Pane with Low-E
104
0.640
67
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 0.09
Door 2: Glass
18
0.580
10
SHGC: 0.78
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 0.81
Wall 4: Wood Frame, 16" o.c.
262
13.0 0.0
19
Window 4: Metal Frame:Double Pane with Low-E
32
0.640
20
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Right Side
Projection factor: 0.10
Wall 5: Wood Frame, 16" o.c.
261
13.0 0.0
19
Window 5: Metal Frame:Double Pane with Low-E
30
0.640
19
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Front
Projection factor: 0.23
Wall 6: Wood Frame, 16" o.c.
308
13.0 0.0
22
Window 6: Metal Frame:Double Pane with Low-E
42
0.640
27
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 7: Wood Frame, 16" o.c.
261
13.0 0.0
20
Window 7: Metal Frame:Double Pane with Low-E
22
0.640
14
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Wall 8: Wood Frame, 16" o.c.
308
13.0 0.0
23
Window 8: Metal Frame:Double Pane with Low-E
26
0.640
17
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Slab-On-Grade:Unheated
174
0.0
181
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described
here is consistent with the building plans, specifications,
and other calculations submitted with the permit application.
The proposed
building has been designed to
meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory requirements listed in
the RES check Ins io Ch
list
�
Builder/Desi er
Date