Loading...
HomeMy WebLinkAboutRES2008-02067, 08-2068T� / ,� i !, %I -� WF1056162 / 001 City of College Station PAGE 1 E� REQ. DATE: 07/09/08 07/09/08 14:14:32 LOCATION: 1104 HARRISONBURG LN LOC ID: 202674 REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 07/09/08 SCHED COMPLETION: 07/09/08 JOB ORDER RESULT COM=S PREPARED 8/20/09, 8:02:49 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/19/09 ------------------------------------------------------------------------------------------------ ADDRESS . : 1104 HARRISONBURG LN SUBDIV: SHENANDOAH PH 14 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER ED FROEHLING BUILDER INC PHONE PARCEL 569500-1441-0140 APPL NUMBER: 08-00002067 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/08/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00 8/08/08 AP August 8, 2008 9:30:19 AM glsouth. B120 01 8/15/08 OC BLDG, FRAMING -PARTIAL TIME: 17:00 f " 8/15/08 AP August 15, 2008 10:07:08 AM bboerboom. APA inspection. 13115 01 10/17/08 RH BLDG, FRAMING TIME: 17:00 10/17/08 AE October 16, 2008 2:05:32 PM glsouth. Double joist at attic access. Connect plumbing vent pipes. Bath fan ducts need to be vented at soffits. B130 01 10/24/08 OC BLDG, INSULATION TIME: 17:00 10/24/08 AP October 23, 2008 3:52:17 PM glsouth. B125 01 8/19/09 BI BLDG, FINAL TIME: 17:00 - A%- Pf August 19, 2009 4:41:14 PM khejny. ----------------------------------- CONTINUED ONTO NEXT PAGE ------------------------------------- �ylLQ,�L �J 08/19/2009 16:19 9797740565 ED FROEHLING BUILDER ACE VEST CONTROL T.P.C.L. # 7120 PT ' PO )SOX 4474 ERYAN, TX 77805 (979) 823-7777 (979) 774-4736 TIry ICAA ..0 The ;Following property _ U ] ,,_ SONBUP-G LN. built . Kk0EHLRjg1Romq State of Texas County of 9RAZ0S t11e city of COLLEGE S ANION Mailing Address SAIV[E ._ Zip code 7784$ was treated for subterranean termites on this day ,AUGUST' 07, 2005attd has met with approval. Cost of initial treatment, 238.58 is payable uponcompletion of work, The treatment is guaranteed for 12 months from the date of treatment. Therea&r, this. contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection and renewal fee of $ 120 plus tax, for a period of (see attached letter) If at any time during this contract a reinfestatiou of subterranean termites should occur, the above said property will be treated at no additional cost to the owner. ACE PEST CONTROL. does not accept any liability for any subterranean termite damage repair. Failure to pay the annual renewal fee wig thirty days after the inspection date shall be construed as a cancellation of this contract. Any alteration or addition to the foundation of the above described property without proper smite treatment by ACE PEST CONTROL Services shall nullify this contract. Liccnscd and RegulaW by the Texas Department orAgiculftn,, SMJctUTW Pftt Control Service, PO Box 12847, Austin, Texas 78711.2847 (512)305-82$0 PAGE 02/03 08/19/2009 16:19 9797740565 ED FROEHLING BUILDER PAGE 03/03 TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT .ration to b��� FR06HLING HOMES 1104 kRMSONSURG LN. ([4� 1`633 F� y �jng• BRA NOFIZOntallPer(meterBsam_)0 ABEL FOR ANY OTHER PESTICOE MOMENDEP OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ApM LUDINp AREA COVERED, TAME PERIOD or WARRAWTY, RENEWAL OMONSAND COST. 7 FIE OBLIGATIONS OF THE PEST CONTROL OPEFU►TOR It7 RE EAT FOR T UMM- INFESTATIONS OR REPAIR DAMAr.E CAUSED 6Y TERM,, INFESTATION$ WRWiW THE WARRANII PERIOp, AND TI E CONDITION$ THAT OLD DEVELOP ASA RESULT OF THC OWNER'$ ACTION oR lNACTIQN THAT WOULD VOID THE WARRANTY WA8 ALSO " ",ATTACHED.DT14 largos for pre -treat: )TES: Annual re-newal. $23108' 120&00 32139 .PT Ce 6r TaehlrkcIm SPCS been,, N 8 r"8 SN29 PT BUILDING PERMIT CITY OF ICOLL19GE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00002067 Date 7/09/08 Application pin number . . . 021085 Property Address . . . . . . 1104 HARRISONBURG LN Property ID: 569500-1441-0140 R #: R302536 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 146916 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDER INC ED FROEHLING BUILDERS 3887 HIGH LONESOME 3887 HIGH LONESOME RD COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 13.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 19.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT Is GLAZING 10.94 GLAZING U-FACTOR .64 HEATED AREA 2226.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .40 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 586016 Permit Fee . . . . 601.00 Plan Check Fee .00 Issue Date . . . . 7/09/08 Valuation . . . . 146916 Expiration Date 1/05/09 - BUILDING DEPT REPRESEU ATIVE: — APPLICANT: BUILDING PERMIT CITY OF,COLLI�GE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . Application pin number Qty Unit Charge Per 47.00 3.0000 THOU 08-00002067 021085 BASE FEE BLDG, VAL 100001-500000 Page 2 Date 7/09/08 Extension 460.00 141.00 Special Notes and Comments -Add Kitchen Island GFI -Add 1st Floor Smoke Detector -Narrow Wall Bracing Fully Sheathed *IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. *ADD SMOKE DETECTOR(S) PER NOTES ON PLANS *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Divertejto an Approved Point of --------------------------------------------� ------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF-COLL9GE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00002067 Application pin number . . . 021085 Page 3 Date 7/09/08 Special Notes and Comments Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR *ATTACHED GARAGES SHALL HAVE PENETRATIONS SEALED *Assure Proper GFI Locations, Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT BE ELEVATED TO ALLOW FOR ATTIC *Wall and Ceiling Insulation If Wall to Window Ratio is of R-13 and R-30, above 15% the GARAGE DOOR HEADER ALL TOP PLATE AND HEADER Including One Within 25' Of AND/OR ACCESS MAY HAVE TO INSULATION are as follows respectively. to 1501 the Values Shall be Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 * THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMI----, WIDTH OF 12' -------------------------------------------•r-----------BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF-COLL2GE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00002067 Application pin number . . . 021085 Page 4 Date 7/09/08 Special Notes and Comments *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIEUT OF ALL GLAZED --------------------------------------------- ----� - ---------- BUILDING DEPT REPRESENTATIVE: - APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00002067 Date 7/09/08 Application pin number . . . 021085 ---------------------------------------------------------------------------- Special Notes and Comments FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200-o TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2006 IRC) *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK *GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. *PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY BEING ELEVATED A MINIMUM OF 18" ABOVE FLOOR LEVEL. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 601.00 601.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750 0 .00 _ .00 -----------------------------------------------/------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF -COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Page 6 Application Number . . . . . 08-00002067 Date 7/09/08 Application pin number . . . 021085 Grand Total 1351.00 1351.00 .00 .00 ---------------------------------------- ---- -----� --------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF -COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00002068 Date 7/09/08 Application pin number . . . 103340 Property Address . . . . . . 1104 HARRISONBURG LN Property ID: 569500-1441-0140 R #: R302536 Application type description TEMP POLE Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ED FROEHLING BUILDER INC ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME 3887 HIGH LONESOME RD COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845 (979) 776-8266 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 586032 Permit Fee . . . . 20.00 Issue Date . . . . 7/09/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------------------------/j_-- ®- ---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: � APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE (*hr4" COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning d Developmrnt Services WWW.CSTX.GOV �f DATE: /� TRCC REG IS61 APPLICATION # TEMP POLE #a o&69 ADDRESS/LOCATION:, 4 >. LOT ! BLOCK *�SUBDIVISION �'�- (.� AN'DO�� SEC/PH 14 BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOME0INNER:'" ��T� u�� r J, � ` HONE: -77b CONTACT PERSON FOR REVIEW COMMENTS: �Af�1 PHONE: FAX: - _-7-74 - - c�,5co95- EMAIL: ELECTRICIAN: 0 PLUMBER:---rMLPL' S HVAC: tNrlo\k-rN'E GOOD CENTS (Residential only): ACCESSORY/STORAGE, MOVING RE -ROOF ADDITION .-v EW CONSTRUCTION* SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION '*. El REMODEURENOVATION* DESCRIPTION OF WORK: PROPOSED USE: �Jth�Ca►I�111..�i • STRUCTURE USE: HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TA ) PROJECT REGISTRATION# EABPRJ VALUATION: $ 14<e;G t(e t� TOTAL AREA: 'Z7Z3 HEATED AREA: rLZ�ZLP (Cost of Labor and Materials) PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM EWER TAP: &?'WATER TAP: OTHER TAP: 9TEMP POLE GARAGE TYPE: 4It SIZE 31411 SIZE NUMBER OF BEDROOMS: 4 NUMBER OF BATHROOMS: 2.112 INTERIOR WALL TYPE: EXTERIOR WALL TYPE:c Y� FOUNDATION TYPE: ':bLAEPb es 4A11��1�C' SIZE ` ROOF TYPE: c6M�j tTi Q jV SINGLE OUBLE G21 TRIPLE a ATTACHED DETACHED F_� CARPORT F] SIGNATURE OF APPLICANT: Y *If proposed work involves new commerci nstr on or facade im nts/renovations to an existing commercial property, building elevations are required. Official Use Only S�ai RS Plans Examiner -- ttl�a GFr C nts: Y S r NO Zoning Official F"-Typc, x GAn.'Oye Ce4le'y ! 6Ade ,to ck- V'4 rkoo- (,."; J awj -vf "/lp F Energy Code Compliance Information % Glazing of exterjor,w,all,s Insufatio6R value of exterior"W'a'fis" Insula.tion:R valu,e of ceiling I (flat areas) Insulation R'Valbe- of ceiling 2 (vaulted dr eds/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating (.0 j 5 � Protection Against Subterranean Termites 9/Chemical Termiticide Treatment (Soil Treatment), El Chemical Termit.i,cide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers" 0 Other Verification ofAplilication shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. a PLAN REVIEW (*f/q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# _ aO DATE: BUILDING ADDRESS: I. Foundation Requirements- Minimum City Foundation Standards N A410 K A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck O E. Header sizes indicated on plans N K F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four (24J inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. OK N K PLAN REVIEW (*//4" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning &DevelopmentServica COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements NOOK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N K 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location (*t/q" CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements NAJOK A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ K Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N K Maximum drive width for residence is 25' combined for circular and 12' minimum for —single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N K Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." P A S EXAMINER DATE Jun. IS. 2008 10:31AM McClure & Browne.Eng/Surveying, No.4319 P. 2/2 (:I1`5I-,'- htaffrPE'B,BR AWEEVSIAQSP/W91SU�4EiWC>sAC•>mfYwobutfi" mt?xv, C40P S}b,4w,, Texas7700, )Yjam" Lot 14 51*Ck 41.4wq Scale: 1 " - 20' R R LM- TABLE �� UNE SEARING DISTANCE f U N 45-26*36" E 43.51' L2 N 74'51'10' W 24.23' CURVE TABLE CURVE DELTA RADIUS LENGTH CHORD_ SRG, Ct 6119'57' 5D.00' 53.52' N 16V6'34` E C2 60'00'00' 50.00' 52.36' S 15'26'36` W 0 Harrisonburg Lone 50' R.O.W. N 27' Pavement I/o% 6893, Pg. 105 f 0 I Proposed I N Driveway L 9.5 7.5' I I I I d s.L. I x� A _v U. 0_ pp�,cWp J �`N I I Z o 7 � I I g 5' i Note: Building Setback Linea per City of College Station Unl Development Ordinance2617 �.._ .. _,._.. —.._.. o 10' P.U.E.-T 5 4528'W' W — 49.38' REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\l 102WB.rck TITLE: 1104 HARRISONBURG LANE CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 06/ 12/08 DATE OF PLANS: 3/10/07 PROJECT INFORMATION: Spec Home Lot 14 Block 41, Shenandoah Phase 14 COMPANY INFORMATION: Ed Froehling Builder, Inc 3887 High Lonesome Road College Station, TX 77845 NOTES: Narrow Nurse COMPLIANCE: Passes Maximum UA = 813 Your Home UA = 664 18.3% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.37 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Front Projection factor: 0.09 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Left Side Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1136 30.0 0.0 40 1090 30.0 0.0 38 320 13.0 0.0 18 64 0.640 41 38 262 13.0 0.0 29 0.400 15 19 0.640 19 /I t_ Projection factor: 0.09 Wall 3: Wood Frame, 16" o.c. 320 13.0 0.0 16 Window 3: Metal Frame:Double Pane with Low-E 104 0.640 67 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Back Projection factor: 0.09 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 315 deg. from North; Comp. orient.: Back Projection factor: 0.81 Wall 4: Wood Frame, 16" o.c. 262 13.0 0.0 19 Window 4: Metal Frame:Double Pane with Low-E 32 0.640 20 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Right Side Projection factor: 0.10 Wall 5: Wood Frame, 16" o.c. 261 13.0 0.0 19 Window 5: Metal Frame:Double Pane with Low-E 30 0.640 19 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Front Projection factor: 0.23 Wall 6: Wood Frame, 16" o.c. 308 13.0 0.0 22 Window 6: Metal Frame:Double Pane with Low-E 42 0.640 27 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Left Side Projection factor: 0.27 Wall 7: Wood Frame, 16" o.c. 261 13.0 0.0 20 Window 7: Metal Frame:Double Pane with Low-E 22 0.640 14 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Back Projection factor: 0.27 Wall 8: Wood Frame, 16" o.c. 308 13.0 0.0 23 Window 8: Metal Frame:Double Pane with Low-E 26 0.640 17 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Slab-On-Grade:Unheated 174 0.0 181 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory requirements listed in the RES check Ins io Ch list � Builder/Desi er Date