HomeMy WebLinkAboutDEMO2008-02054Of* 054
DEMOLITION PERMIT
CITY OV-CCYI!LEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Tenant nbr, name . . . . . .
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00002054 Date 6/30/08
973204
209 UNIVERSITY DR
144500-0008-0021
R87069
AQUARIUM
DEMOLITION, COMMERCIAL
BOYETT
UNKNOWN
1000
Owner Contractor
------------------------ ------------------------
WALSTON, JIMMIE DE AVILA CONSTRUCTION
4500 WILLIAMS DR 13106 KENSWICK DR
GEORGETOWN TX 786281301 AUSTIN TX 78753
(512) 627-9656
--- Structure Information 000 000 INTERIOR & ROOF DEMO
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . ASSEMBLY (IBC)
Other struct info . . . . . TRAFFIC IMPACT ANAL (TAZ) 450.00
----------------------------------------------------------------------------
Permit . . . . . . DEMOLITION PERMIT
Additional desc . . AC
Permit pin number . 584649
Permit Fee . . . . 25.00 Plan Check Fee .00
Issue Date . . . . 6/30/08 Valuation . . . . 1000
Expiration Date . . 12/27/08
Qty Unit Charge Per Extension
BASE FEE 25.00
----------------------------------------------------------------------------
Special Notes and Comments
THE TEXAS DEPARTMENT OF HEALTH REQUIRES AN ASBESTOS SURVEY
IN CERTAIN CIRCUMSTANCES - CALL TDH @ (254) 778-6744 FOR
MORE INFORMATION
Permit Number provided by the COOS shall be conspicuously
posted in the lower right hand corner of the banner.
Shall be mounted parallel to the face of a building or
permanent structure.
Shall advertise only the name of, uses of, or goods or
services available within the building or tenant lease
space to which the banner is attached.
Shall not be located within public road ROW (State or
Local) . ------------------------------------
(L�
BUILD
APPLI
DEMOLITION PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
2
Application Number . . . . . 08-00002054 Date
6/30/08
Application pin number . . . 973204
----------------------------------------------------------------------------
Special Notes and Comments
Shall not obstruct any window, door, stairway, or other
opening inteded for ingress or for needed ventilation or
light.
Shall not exceed the top of the structure to which it is
attached.
*ALL UTILITIES MUST BE DISCONNECTED BEFORE DEMOLITION
BEGINS. PLUMBING SEWER LINES MUST BE CAPPED TO AVOID STORM
WATER FLOWING INTO LINES. MAINTAIN SAFE JOB SITE AND REMOVE
ALL DEBRI PROMPTLY.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 25.00 25.00 .00
.00
Plan Check Total .00 .00 .00
.00
Grand Total 25.00 25.00 .00
.00
BUILDING DEPT REPRESENTAT
APPLI
u
F /U�s��r7On
APPLICATION FOR BUILDING PERMIT DATE:
h CITY OF COLLEGE STATION APPLICATION # '
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITYOF COLLEGE S"1"Ar1ON TEMP POLE #
Plunningc�'a�arinpn,art.Ssrrltrr (979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
ADDRESS/LOCATION: ao 9 elh 1 dGr!
LOT BLOCK -� SUBDIVISION SE/C�/PH
BUSINESS/OWNER NAME: ! Y1a 4A&4Af%AVV% pr Nfor4-Ugrjt*_ PHONE: rL9tAj
CONTRACTOR/HOMEOWNER: Aga_ j11g COhttt/K��iOr) PHONE: �Si1-)
CONTACT PERSON FOR REVIEW COMMENTS: q C<N\;t dQt A-f1A`^ PHONE:
FAX:
ELECTRICIAN:
HVAC:
ACCESSORY/STORAGE
,ADDITION
DEMOLITION (ASBESTOS SURVEY)
DUPLEX (LANDSCAPE PLANS REQUIRED)
LOCATION
RETAINING WALL
DESCRIPTION OF WORK:
PROPOSED USE:
STRUCTURE USE:
EMAIL:
PLUMBER:
GOOD CENTS (Residential only):
MOVING
NEW CONSTRUCTION*
PORTABLE STORAGE (RESIDENTIAL)
PORTABLE STORAGE (NON-RESIDENTIAL)
REMODEL/RENOVATION*
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION NO. EABPRJ
VALUATION: $ /000 - eo TOTAL AREA:
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
WATER TAP:
OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
SIZE
SINGLE 71
ATTACHED -
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE F1
DETACHED I -I
TRIPLE
:/jRPO .%
HEATED AREA:
RE -ROOF
SHELL ONLY
SLAB ONLY
SWIMMING POOL
TENT
SIGNATURE OF APPLICANT-,, I- �Ctb -
*If proposed work involves new commercial construction or facade impro is/renovations to an existing
commercial property, building elevations are required.
............................................................
Official Use Only
�� Comments:
rNO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling I (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
❑ Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
PLM Summary Report
Steve Moody Micro Services, LLC NVLAP Lab No. 102056
2051 Valley View Lane TDSHS License No. 30-0084
Farmers Branch, TX 75234 (Phone 972-241-8460)
Client : Austin Environmental, Inc. Lab Job No.: 0813-06941
Project : Former Aggieland Flowers, 209 University Dr., C.S., TX Report Date : 06/10/2008
Project # : AE08-308 Sample Date: 06/06/2008'
Identification : Asbestos, Bulk Sample Analysis
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116 Page 1 of 3
On 6/10/2008, thirty (30) bulk material samples were submitted by Brent Plant of Austin Environmental, Inc. for asbestos analysis by PLM/DS. The PLM
Detail Report is attached; additional information may be found therein. The results are summarized below:
Sample Number
Client Sample Description / Location
Asbestos Content
OIA
Lay -in Ceiling Tile, above Back Exit Door
None Detected - Acoustic Tile
O1B
Lay -in Ceiling Tile, Storage Roo Room Center
None Detected - Acoustic Tile
O1C
Lay -in Ceiling Tile, at Entry to Retail Area
None Detected - Acoustic Tile
02A
Linoleum (Blue), outside Office
None Detected - Sheet Flooring
None Detected - Fiber Backing
None Detected - Cream Mastic
None Detected - Brown Mastic
02B
Linoleum (Blue), at Back Door
None Detected - Sheet Flooring
None Detected - Fiber Backing
None Detected - Cream Mastic
None Detected - Black Mastic
02C
Linoleum (Blue), Restroom, Center
None Detected - Sheet Flooring
None Detected - Fiber Backing
None Detected - Cream Mastic
None Detected - Brown Mastic
03A
Cove Base Mastic, at Front Entry
None Detected - Cove Base
None Detected - Cream Mastic
03B
Cove Base Mastic, Retail, inside Left Wall
None Detected - Cove Base
None Detected - Cream Mastic
03C
Cove Base Mastic, Back Wall, Center
None Detected - Cove Base
None Detected - Cream Mastic
04A
Drywall Texture, Ceiling at Attic Access
None Detected - Drywall Material
None Detected - Texture
04B
Drywall Texture, Ceiling, Retail, Center at Retrun Air
None Detected - Joint Compound
Vent (Damaged Area)
None Detected - Texture
04C
Drywall Texture, Ceiling, Retail, Left Side Pass Through
None Detected - Drywall Material
(above)
None Detected - Texture / Joint Cmpd
PLM Summary Report
Steve Moody Micro Services, LLC NVLAP Lab No. 102056
2051 Valley View Lane TDSHS License No. 30-0084
Farmers Branch, TX 75234 (Phone 972-241-8460)
Client: Austin Environmental, Inc. Lab Job No.: 0813-06941
Project : Former Aggieland Flowers, 209 University Dr., C.S., TX Report Date: 06/10/2008
Project # : AE08-308 Sample Date: 06/06/2008
Identification : Asbestos, Bulk Sample Analysis
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116 Page 2 of 3
On 6/10/2008, thirty (30) bulk material samples were submitted by Brent Plant of Austin Environmental, Inc. for asbestos analysis by PLM/DS. The PLM
Detail Report is attached; additional information may be found therein. The results are summarized below:
Sample Number
Client Sample Description / Location
Asbestos Content
O5A
HVAC Duct Mastic (Whie), Attic, South Center on Duct
None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - White Mastic
05B
HVAC Duct Mastic (Whie), Attic, South Center on Duct
None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - White Mastic
O5C
HVAC Duct Mastic (Whie), Attic, South Center on Duct
None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - White Mastic
06
Built-up Roof, South End, Debris
None Detected - Aggregate
None Detected - Roofing Tar
None Detected - Roofing Felts
None Detected - Fiber Board
07
Parapet, Center of Building
10% Chrysotile - Flashing Material
None Detected - Glass Fiber Mesh
08
Roof Mastic (Black), Debris, South next to HVAC Unit
None Detected - Black Mastic
09A
12" x 12" Floor Tile (Gray), Retail, at Entry by Door Right
None Detected - Floor Tile
Side
None Detected - Yellow Mastic
None Detected - Leveling Compound
O9B
12" x 12" Floor Tile (Gray), Retail, at Entry Inside
None Detected - Vinyl Facing
None Detected - Yellow Mastic
None Detected - Leveling Compound
None Detected - Black Mastic
O9C
12" x 12" Floor Tile (Gray), Retail, at Entry by Door Left
None Detected - Floor Tile
Side
None Detected - Yellow Mastic
None Detected - Leveling Compound
None Detected - Black Mastic
10A
Wall Plaster, Front Retail, Inside Left, Debris
None Detected - Base Plaster
None Detected - Finish Plaster
lOB
Wall Plaster, Front Retail, Inside Left, Center
None Detected - Base Plaster
None Detected - Finish Plaster
PLM Summary Report
Steve Moody Micro Services, LLC
NVLAP Lab No. 102056
2051 Valley View Lane
TDSHS License No. 30-0084
Farmers Branch, TX 75234 (Phone 972-241-8460)
Client : Austin Environmental, Inc.
Lab Job No.: 0813-06941
Project : Former Aggieland Flowers, 209 University Dr., C.S., TX
Report Date : 06/10/2008
Project # : AE08-308 Sample Date: 06/06/2008
Identification : Asbestos, Bulk Sample Analysis
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Page 3 of 3
On 6/10/2008, thirty (30) bulk material samples were submitted by Brent Plant of Austin Environmental, Inc. for asbestos analysis by PLM/DS. The PLM
Detail Report is attached; additional information may be found therein. The results are summarized below:
Sample Number
Client Sample Description / Location
Asbestos Content
10C
Wall Plaster, Front Retail, Attic, Debris
None Detected - Base Plaster
None Detected - Finish Plaster
11A
Drywall, Walls, Retail, Inside Left
None Detected - Drywall Material
2% Chrysotile - Joint Compound
2% Chrysotile - Texture
11B
Drywall, Walls, Retail, Inside Right
Not Analyzed - Positive Stop
l 1C
Drywall, Walls, Retail, at Dividing Wall, Left Side Pass
Not Analyzed - Positive Stop
Through
12A
Floor Mastic, under Carpet, at Entry to Retail from Back
None Detected - Carpet
Storage
None Detected - Yellow Mastic
12B
Floor Mastic, under Carpet, under Attic Access Ladder
None Detected - Carpet
None Detected - Yellow Mastic
12C
Floor Mastic, under Carpet, at Front (South) Entry next to
None Detected - Carpet
Floor Tile
None Detected - Yellow Mastic
These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual r\n^
estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These ti\`/Jjll Ij
test results do not imply endorsement by NVLAP or any agency of the U.S. Government. Accredited by the
National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056.
Analyst(s): Greg Werchan
Lab Manager: Bruce Crabb Approved Signatory:
_
Lab Director: Steve MoodyApproved Signatory :
— Thank you for choosing Steve Moody Micro Services
— — — —