Loading...
HomeMy WebLinkAboutRES2008-02043, 08-2044TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT I �_ weer: Pro riv O � - �YRi4D T� Ftt�lift'iEs� �; .:... :....... . r , tion to be Treated-Approximajg s_to be Treaft&jL_ Percentaa@ of Termticide{$) to be applied at this lotion: Type of Treatragmt: EuLl Partial XX rtical XX_ Horizontal/Perimeter Beam XX Foundation.:.SLAB SidingBRICK- Primary Use:R,�SIDENCE Roof: COMPOSITION A LABEL FOR ANY OTHER PESTICIDE RECOmwvmO OR USED HAS BEEN ATTACHED AS PART OF THIS DM AMNT. WARRANTY INFORMATION (IF ANY) INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THI; PEST CONTROL OPERATOR TO RE, TREAT FOR YERMIT♦: INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. r re -treat. --. Charges for NOTES: Annual re-newal: �.;•;:.-- ...:r.�..M Ca or Toddrdwt SPC8 Nc.r 32129 PT Ed Wd82:0T 800E SE '^ON 2-b9TS986e'6: 'ON Xdd : WOdj ACE PEST CONTROL, PO BOX 4474 BRYAN, TX 77905 (979) 823-7 777 TPCL 7120 PT LIMITATIONS OF LIABILITY 1. ACE PEST CONTROL'S liability for additional treatment of the covered property is limited to areas of infestation to the structure(s) which occur during the term of this agreement (with the restrictions of the chemical label). 2. ACE PEST CONTROL shall not be liable for property that has been added to or structurally altered unless ACE PEST CONTROL has been notified prior to the beginning of any additions or alterations, and any additional treatment or re -treatment found necessary is performed. Such additional treatment must be performed by ACE PEST CONTROL at the expense of the owner. 3. ACE PEST CONTROL shall have no liability under this agreement should the customer refuse access to the covered premises of any additions for the purpose of carrying out the terms and conditions of the agreement. 4. ,ACE PEST CONTROL shall not be liable for re -treatment of subterranean termite infestation caused by ABNORMAL moisture conditions such as leaky roofs, shower stalls, plumbing, or wet soil under the structure due to poor ventilation. 5. This service agreement does not guarantee against present or future damage to property or contents, nor provide for repairs or compensation therefore. This service agreement is for subterranean termites only, and does not include treatment for dry - wood termites, carpenter ants, powder post beetles, or other wood destroying insects. 6. ACE PEST CONTROL shall not be liable for re -treatments of subterranean termites caused by excess wood left around the foundation. For example: wood forms, railroad ties, or any excess wood forms left in tub drains. Licensed and regulated by the Structural Pest Control Board P.O. Box 1927 Austin, Texas 78767-1927 (512) 305-8250 2d Wd82 2T 800Z SE 'ON XUA : W06A ACE PEST CONTROL T.P.C.L. # 7120 PT PO BOX 4474 BRYAN, TX 77805 (979) 823-7777 (979) 7744736 CERTIFICATE The following property 232 PASSENDALE built by TRADITION HOMES State of' Texas County of BRAZOS the city of COLLEGE STATION Mailing Address SAME Zip code 77845 was treated for subterranean termites on this day JULY 22, 2008 and has met with approval. Cost of initial treatment, $364.84, is payable upon completion of work. The treatment is guaranteed for 12 months from the date of treatment. Thereafter, this contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection and renewal fee of S 130 plus tax, for a period of 4 years. ( see attached letter) If at any time during this contract a reinfestation of subterranean termites should occur, the above said property will be treated at no additional cost to the owner. ACE PEST CONTROL does not accept any liability for any subterranean termite damage repair. Failure to pay the annual renewal fee within thirty clays after the inspection date shall be construed as a cancellation of this contract. Any alteration or addition to the foundation of the above described property without proper termite treatment by ACE PEST CONTROL Services shall nullify this contract. Licensed and kcgulatcd by the Texas Department of Agriculture, Structural Pest Control Service, PO Box 12847, Austin, Texas 79711-2847 (512) 305-8250 bd Wd62:0T 800E SE 'SON 2_b9TS986Z6: 'ON Xdd : Wodd CONSUMER INFORMATION SHEET The stnictural pest control industry is regulated by the Texas Department of Agriculture (TDA), Structural pe$t Control Service (SPCS), PO Box 12847, Austin, TX 78711-2847, TDA licenses the businesses, certified applicators and technicians who perform structural pest control work. Certified applicators and technicians must pass a written examination in order to receive their licenses. Pesticides must be registered with the United States Environmental Protection Agency (EPA) and TDA before they may be used in Texas. EPA registration is not a finding of product safety. Pesticides are designed to kill or control pests. Your risk of harm depends upon the degree of your exposure and your individual susceptibility. Specific health and safety information varies between pesticides and types of exposures and is available on the label info,,, atioii ui N13n3 ,Ilrei, which can be supplied to you upon request from the licensed applicator. `fake precautions when a treatment has been performed to avoid exposure to vulnerable individuals. Pesticides may be harm ful if swallowed, inhaled, or absorbed through the skin. Avoid breathing dust or spray mist and any unnecess<3ry contactwith treated surfaces. If you desire cnPrifie, infnrmation on precautions„ refor to the postiridc label. T!« law rcquims Mat the application procedures specified on the label be followed. If you have questions about the application, contact the business or person making the application. If you suspect a violation of the law regarding structural pest control, contact the SPCS. In case of a health emergency, seek immediate medical attention. Pest Control signs must be posted prior to treatment in many inatanecs. The signs should be posted in an area of common access at least 48 hours prior to treatment. The information sip will allow you to contact someone who can tell you what pesticide is being used. If you are contracting for pest control services due to a home solicitation, you have the right to cancel the contract within 72 hours. You may exercise this right by notifying the pest control company that you do not wish to receive their service_ 1'or general information on pesticides, contact the National Pesticide Information Center 1-800-858-7378 For information concerning structural pest control laws, contact the Structural Pest Control Service at : (512) 305-8250 or 866-918-4481. For information concerning the formulation and registration of pesticides, contact the TDA pesticide registration at (512) 463-7476 or 800-835-5832. For non -emergency health information relating to pesticides, contact Texas Department of State Health Services (512) 458-7111. REDUCED IMPACT SERVICE In order to minimize the reliance on pesticides and reduce pest populations, a Reduced Impact Pest Control operator may recommend that you consider the sanitation or physical alteration of your work place or residence. It is your re-ponsibility to follow those recommendations. Your pest control operator may or may not offer these services upon request. A proper inspection will provide the information necessary for you to choose the method of pest control which best suits your situation. Many pest problems can be solved without using pesticides. This Reduced Impact Service will include an inspection report and treatment recommendations. You should review these and keep a copy for your records. Your cooperation in following the recommendations made by your service provider is essential to a reduced impact service program. Pesticides may be used in a responsible and professional manner in a reduced impact pest control service. If you do not want a specific pesticide used or any pesticides used at all, you must note this in writing on the contract prior to the initiation of the service. If any specific pesticide or class of pesticides are not excluded, it may be used by the provider. REQUIRED BY THE TDA STRUCTURAL PEST CONTROL SERVICE Revised 09/01/07 Page IofI Sd Wd62:OT 800E SE '^ON 2-b9SS986Z6: 'ON Xd.d : Wodd h SUBTERRANEAN T)ERNM)E pRECONSTRUCTION DISCLOSURE FOR EACH ESTMATE For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember that your architects or design engineers specifications in violation Of the law. Review the consumer information heet for further inbe formation, on, If have d, unless they an questions, contact the pest control company or the Texas Structural Pest Control Board, PO Box 1927, y Austin, Texas 7$767-1927. Telephone number (512) 305-8250. Name of Customer, ~ Y �6- 4i 0, ,.,.,e 5 City State Zip Location to be Treated 6 <,--T� - —7 7 Type of Treatment: [ ] Full A label of{•.`�t'�,r. termiticide(s) is enclosed. The percentage of the termiticide(s) to be applied at this location is Q 6 )- Warranty Information provided must include the Complete Details of any Warranty provid follnwixg: Time Period of Warranty, Renewal options ed and the Parties and host; and Obligatlons of the Contracting If the warranty does not include the entire structure treated, the areas included in the warranty are: (specify) _- Total Square Feet to be Treated; �J y .Total Linear Feet to be Treated:` Approximate Measurements of the Structure(s) to be Treated: VCLlf4g 1° 'Ter Z Z Signature of Certified Applicator or Printed Name Technician Completing Estimate Date t-M Name of Pest Control Company TPCL. No. Licensed and regulated under the Texas Structural pest Control Act Texas Structural Pest Control Hoard, kO Box 1927, Austin, Texas 78767-1927, Telephone number (512)3054250. Sample Form — Aprll 4, 2005 Page I of 2 9d WdOV:OT BOW SE 'AON 2-b9tS986Z6: 'ON Xtid : WMId 554001'25"W-60.00' 2 5 2 PA55ENVALE LANE LOT 1, BLOCK 1 q EVELAE155 GARTENS, PHASE 5 (j0' BUILDING LINE PA55ENPALE LANE PREPARED 11/24/08, 12:08:49 INSPECTION TICKET PAGE 9 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/24/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 232 PASSENDALE LN SUBDIV: EDELWEISS GARTENS PH 8 CONTRACTOR TRADITION HOMES PHONE (979) 204-6604 OWNER EDELWEISS GARTEN VENTURE PHONE PARCEL 244030-0819-0090 APPL NUMBER: 08-00002043 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/22/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00 7/22/08 AP July 22, 2008 12:03:23 PM acarter. Strings up. Slab ground installed B115 01 8/22/08 RH BLDG, FRAMING TIME: 17:00 8/22/08 AE August 22, 2008 11:38:17 AM ccourt. By insulation install proper fireblock for fireplace, joist hanger at a/c return air. Need repair strap above electrical panel not nail plates. B130 01 8/27/08 OC BLDG, INSULATION TIME: 17:00 8/28/08 AP August 27, 2008 12:54:53 PM bboerboom. B125 01 11/24/08 BI BLDG, FINAL TIME: 17:00 November 24, 2008 12:01:02 PM glsouth. -------------------------------------- COMMENTS AND NOTES -------------------------------------- WF1056749 / 001 City of College Station PAGE 1 REQ. DATE: 07/10/08 07/10/08 16:37:33 LOCATION: 232 PASSENDALE LN LOC ID: 203022 REQUESTOR: TRADITION HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: CCOURT AUTH USER:CCOURT WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 07/10/08 SCHED COMPLETION: 07/10/08 ******************************************************************************** JOB ORDER RESULT COM41EN PS BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00002043 Date 7/10/08 Application pin number . . . 259431 Property Address . . . . . . 232 PASSENDALE LN Property ID: 244030-0819-0090 R #: R302721 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 160000 Owner Contractor ------------------------ EDELWEISS GARTEN ------------------------ VENTURE TRADITION HOMES 311 CECILIA LOOP 89 WINDMILL DR. COLLEGE STATION TX 778456310 HEMPSTEAD TX 77445 (979) 204-6604 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 13.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 19.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT GLAZING 13.20 GLAZING U-FACTOR .47 HEATED AREA 1820.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .35 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 405.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc CC Permit pin number 586578 Permit Fee . . . . 640.00 Plan Check Fee .00 Issue Date . . . . 7/10/08 Valuation . . . . 160000 Expiration Date 1/06/09 --------------------------------------------- ------ ---- ------- 9------------ BUILDING DEPT REPRESENTATIVE: g APPLICANT: CA.9-.. �* BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Qty Unit Charge Per 08-00002043 259431 BASE FEE 60.00 3.0000 THOU BLDG, VAL 100001-500000 Page 2 Date 7/10/08 Extension 460.00 180.00 ---------------------------------------------------------------------------- Special Notes and Comments -Relocate smoke detector to outside of bedroom area. -Narrow Wall Bracing Fully Sheathed *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED ---------------------------------------- ----- BUILDING DEPT REPRESENTATIVE: APPLICANT: , N�/ BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00002043 Date 7/10/08 Application pin number . . . 259431 ---------------------------------------------------------------------------- Special Notes and Comments *Assure Proper GFI Locations, Including One Within 25, Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 15% the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 * THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO - --------------- ----- ---------------- - ------- ------ --- ----------------- BUILDING DEPT REPRESENTATIVE: j APPLICANT: (A . BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00002043 Date 7/10/08 Application pin number . . . 259431 ---------------------------------------------------------------------------- Special Notes and Comments ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 300-. A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS ----------------------------------- ------ --- + ----vim ------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: G -6_1�_ BUILDING VERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00002043 Date 7/10/08 Application pin number . . . 259431 ---------------------------------------------------------------------------- Special Notes and Comments *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 241- OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 411 350.00 WATER TAP 3/411 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 640.00 640.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1390.00 1390.00 .00 .00 -------------------------------------------------- --- ----� .------------ BUILDING DEPT/REPRESENTATIVE: APPLICANT: [A - �_� TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 08-00002044 362348 232 PASSENDALE LN 244030-0819-0090 R302721 TEMP POLE Date 7/10/08 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ TRADITION HOMES 311 CECILIA LOOP 89 WINDMILL DR. COLLEGE STATION TX 778456310 HEMPSTEAD TX 77445 (979) 204-6604 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc CC Permit pin number 586586 Permit Fee . . . . 20.00 Issue Date . . . . 7/10/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Fee summary ----------------- Charged -------------------- Paid Credited Due -------------------- Permit Fee Total 20.00 20.00 .00 .00 Grand Total 20.00 20.00 .00 .00 --------------------- ---------------------- ------ - -- - --� }------ - - - - -- BUILDING DEPT REPRESENTATIVE: - �i�;0' APPLICANT: a- 6�-- For Offl- Um 0* 1 APPLICATION FOR BUILDING PERMIT DATE: 1.0-0cREc W3 (w CITY OF COLLEGE STATION 1101 TEXAS AVENUE APPUCAnoN # COLLEGE STATION, TX 77MO TEMP POLE # CITY of COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX %JunarudV Dsrr(oparnt Srn•i�t WWW.CSTX.GOV ADDRESS/LOCATION: O2 3g LOT BLOCKq_v_'S�UBDIVISION rbLL k)15 .35 6,4 'SEC/yH BUSINESS/OWNER NAME: �LV CONTRACTOR/HOMEOWNER: jo Cw l N PHONE: PERSON FOR REVIEW COMMENTS: 0 LVI� q' -O`(i7 CONTACT �� [T N PHONE: (7 FAX: EMAIL: 1D►L11 (l L(�1 rl\Bil lymesbe-:5, q ELECTRICIAN: I PLUMBER: a HVAC: 7 `T 1 GOOD CENTS (Residential only): ACCESSORY/STORAGE MOVING RE -ROOF ADDITION NEW CONSTRUCTION' SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEL/RENOVATION" TENT RETAINING WALL DESCRIPTION OF WORK: PROPOSED USE: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY % D D (TAS) PROJECT REGISTRATION No. EABPRJ VALUATION: $ / _4. TOTAL AREA: �HEATED AREA: (Cost of Labor and Materials)—"—'�—' (! PUBLIC SEWER ❑ SEPTIC/TREATMENT /SYSTEM �1 ��_SEWERTAP_: 1< 2 VE C 0,WATER.TAP: J _T�.._.j SIZE OTHER TAP: r SaE l9 TEMP POLE GARAGE TYPE: SINGLE a ATTACHED SIGNATURE OF APPLICANT: 9 'If proposed work involves new Comm c commercial property, building elevatio s NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE X IETAC�D t TRIPLE CARPORT ED al construction or facade improvements/renovations to an existing Ire required. - rho -F7-i- 0 8 Plans Examiner — �1ioi ffvrtc �/'��'•.L - >�v ply S1.�1�� • as se -Illy mments: Y rN0 Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling I (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites XChemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. PLAN REVIEW (*fl ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# o B _ O q 3 DATE: BUILDING ADDRESS: A 3A en d c, I* Lo - I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated K II. Framing: Floor, Wall, Ceilin and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. K K PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning 6, Development &rvicer COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX 111. Stairway Requirements A. Stairway Details fflOK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N I( A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N AT 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location (*fl"" CITY OF COLLEGE STATION Planning d Development Servinr PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements N K A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N8PK Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed A K "APPROVED PLANS PER IRC SECTION R106.3.1." If 0 C_,/PMTEXAMINER DATE