HomeMy WebLinkAboutRMDL2008-02034officeMax � 08/06/08 14:46 FAX 412 338 8878 GNC CONSTRUCTION Q 003 COMcheck Software Version 3.5.1 86 Lighting Compliance Certificate 2006 IECC Report Date: 06/14/08 Data filename: C:IRSW ConsultantslProjectslGNClGnc-2008185131GNC-8513.cck Section 1: Project Information Project Title: GNC Construction Site: Owner/Agent: Post Oak Mall Ed Kennedy 1500 Harvery Station GNC College Station, TX 77840 300 Sixth Avenue Pittsburgh , PA 15222 (412) 288-4600 Section 2: General Information Building Use Description by: Activity Type Project Type: New Construction Activity Tyoels) Floor Area Retail 1552 Section 3: Requirements Checklist Interior Lighting: 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts complies 3570 3389 YES Controls, Switching, and Wiring: 2. Independent controls for each space (switch/occupancy sensor). Exceptions: Designer/Contractor: Robert Stanley RSW Consultants 17211 Eagle Hollow San Antonio, TX 78248 (210) 408-1860 Areas designated as security or emergency areas that must be continuously illuminated - Lighting in stairways or corridors that are elements of the means of egress. ❑ 3. Master switch at entry to hotel/mote( guea; room. 4. Individual dwelling units separately metered. [� 5. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or sleeping unit. Areas that use less than 0-6 Watts/sq.li. O 6. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: Sleeping units, patient care areas; and ;paces where automatic shutoff would endanger safety or security. El 7. Photocell/astronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. Project Tide: GNC Data filename: C:IRSW ConsultantslProjectslGN,:_IGnc-2008185131GNC-8513.cck Report date: 06/14/08 Page 1 of 3 08/06/08 14:46 FAX 412 338 8878 GNC CONSTRUCTION U 002 08/06/08 11:38 FAX 2104080273 RSW CONSULTANTS a 01 0 8. Tandem wired one4amp and three -lamp ballasted luminaires (No single4amp ballasts). Exceptions: 4 Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available Or. Section 4: Compliance Statement Compliance Statement The proposed lighting design represented in this Kwcon,sistent a building plans. specifications and other caleulatkms submittedwith this permlF. application. The proposem has to meet the 2005 IECC requirements In CQMcheck Veslon 3.5.1 and to comply with the mend ments Checklist. Oa Name - Title Signature Da Project Notes: Tenant Finishout Post -it® Fax Note 7671 Dateg 6 _ pegof To/ • Alnl .� o � From Co./Dept dny/ / '4 l N Co. Phone # Phone Fax —74 ; y/,p/ Fax # Project TIUe: GNC I Report date: 06/14/08 Data filename: C:1RSW ConsultantslProjectslGNC\Gnc-2008\8513tGNC-8513.cck Page 2 o/ 3 08/06/08 14:46 FAX 412 338 8878 GNC CONSTRUCTION R001 nO� COMcheck Softmiare Version 3.5.1 8/1 Lighting Application Worksheet 2006 IECC Report Date: Data filename: C:\RSW Consultants\Projer,:s\GNC\Gnc-2008\8513\GNC-8513.cck Section 1: Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (m) Watts 1 ft2 (B x C) Retail 1552 1.5 2328 Allowance: Merchandise Display / Fix. iD: EE 676(a) 1.6 1082(b) Allowance: Merchandise Display / Fix. ID: F 40(a) 1.6 64(b) Allowance: Merchandise Display / Fix. ID:_G 60(a) 1.6 96(b) Total Allowed Watts = 3570 Section 2: Proposed Lighting Power Calculation A B C D E Fixture ID : Description / Lamp 1 Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Retail (1552 sq.ft.) Linear Fluorescent 3: A: 2' x 2' Fluorescent 124" TB 17W / Magnetic 2 14 51 714 Incandescent 4: C: Downlight / Incandescent 75W 1 7 75 525 Compact Fluorescent 2: EE: 4' wallwasher / BIAX 40W 1 Electronic 1 20 BO 1600 HID 2: F: Track - display window / Metal -lalide 70W / Electronic 1 4 70 280 HID 3: G: Track - floor / Metal Halide 70W / Electronic 1 3 70 210 Incandescent 3: Z: Toilet fan/light / Incandescent 60W 1 1 60 60 Total Proposed Watts = 3389 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Proposed Watts is greater than or equal to zero, the building complies Total Allowed Watts = 3570 Total Proposed Watts = 3389 Project Compliance = 181 •� .ice. .,,.W, T ._.a[..,i.-.-,. 1- i—+�1, �.1 ui? .w-tk�� gyp¢•-.x•W-•.---5.,,,�.._.. �_._..�.,,. eY Loy 'i. ,�^.. �.�.. ._. .YS:- ^.`.iC�sm �' ra( iMETA �w..:...o..�,..�as.i. . 1i5.=�11 an. K Project Title: GNC Data filename: C:\RSW Consultants\Projects\GNC\Gnc-2008\8513\GNC-8513.cck Report date: 06/14/08 Page 3 of 3 PLM Summary Report Steve Moody Micro Services, LLC NVLAP Lab No. 102056 2051 Valley View Lane TDSHS License No. 30-0084 Farmers Branch, TX 75234 (Phone 972-241-8460) Client : Austin Environmental, Inc. Lab Job No.: 0813-08802 Project : Post Oak Mall, GNC Space #3016, 1500 Harvey, C.S., TX Report Date : 07/23/2008 Project # : AE08-381 Sample Date : 07/22/2008 Identification : Asbestos, Bulk Sample Analysis Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 600 / R-93 / 116 Page 1 of 2 On 7/23/2008, twenty one (21) bulk material samples were submitted by Paul Dehlinger of Austin Environmental, Inc. for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below: Sample Number Client Sample Description / Location Asbestos Content OIA Ceiling Tile, Retail at Entrance None Detected - Acoustic Tile O113 Ceiling Tile, Storage Room None Detected - Acoustic Tile O1C Ceiling Tile, Retail at Entrance to Storage Room None Detected - Acoustic Tile 02A 12" x 12" Floor Tile (Grey) and Mastic (Black), Restroom None Detected - Floor Tile None Detected - Clear Mastic 2% Chrysotile - Black Mastic 02B 12" x 12" Floor Tile (Grey) and Mastic (Black), Restroom None Detected - Floor Tile None Detected - Clear Mastic 2% Chrysotile - Black Mastic 02C 12" x 12" Floor Tile (Grey) and Mastic (Black), Restroom None Detected - Floor Tile None Detected - Clear Mastic 2% Chrysotile - Black Mastic 03A 12" x 12" Floor Tile (Red) and Mastic (Black), Storage 5% Chrysotile - Floor Tile Room 10% Chrysotile - Black Mastic 03B 12" x 12" Floor Tile (Red) and Mastic (Black), Storage 5% Chrysotile - Floor Tile Room 10% Chrysotile - Black Mastic 03C 12" x 12" Floor Tile (Red) and Mastic (Black), Storage 5% Chrysotile - Floor Tile Room 10% Chrysotile - Black Mastic 04A Vinyl Flooring, Retail Area at Back Room None Detected - Sheet Flooring None Detected - Yellow Mastic 04B Vinyl Flooring, Retail Front Window Display None Detected - Sheet Flooring None Detected - Yellow Mastic 04C Vinyl Flooring, Retail at Back Room None Detected - Sheet Flooring None Detected - Yellow Mastic 05A Cove Base and Mastic, Storage Room None Detected - Cove Base None Detected - Brown Mastic 05B Cove Base and Mastic, Restroom None Detected - Cove Base None Detected - Brown Mastic PLM Summary Report Steve Moody Micro Services, LLC NVLAP Lab No. 102056 2051 Valley View Lane TDSHS License No. 30-0084 Farmers Branch, TX 75234 (Phone 972-241-8460) Client : Austin Environmental, Inc. Lab Job No.: 0813-08802 Project : Post Oak Mall, GNC Space #3016, 1500 Harvey, C.S., TX Report Date : 07/23/2008 Project # : AE08-381 Sample Date : 07/22/2008 Identification : Asbestos, Bulk Sample Analysis Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 600 / R-93 / 116 Page 2 of 2 On 7/23/2008, twenty one (21) bulk material samples were submitted by Paul Dehlinger of Austin Environmental, Inc. for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below: Sample Number Client Sample Description / Location Asbestos Content 05C Cove Base and Mastic, Storage Room None Detected - Cove Base None Detected - Brown Mastic 06A Drywall Texture, Restroom None Detected - Drywall Material None Detected - Texture 06B Drywall Texture, Storage Room None Detected - Drywall Material None Detected - Paint 06C Drywall Texture, Storage Room None Detected - Drywall Material None Detected - Paint 07A Joint Compound, Storage Room None Detected - Drywall Material None Detected - Joint Compound 07B Joint Compound, Above Restroom None Detected - Drywall Material None Detected - Joint Compound 07C Joint Compound, Storage Room None Detected - Drywall Material None Detected - Joint Compound These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual �^ ^(� ^ estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These �`//f I`Ij(/,���(, rJnJl test results do not imply endorsement by NVLAP or any agency of the U.S. Government. Accredited by the `! National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056. Analyst(s): Jose Ortiz I'z� Lab Manager : Bruce Crabb Approved Signatory : _ _ �j/�' _ Lab Director : Steve Moody Approved Signatory — — — — — — — — — — — Thank you for choosing Steve Moody Micro Services Steve Moody Micro Services, LLC PLM Detail Report 2051 Valley View Lane Supplement to PLM Summary Report Farmers Branch, TX 75234 Client : Austin Environmental, Inc. Project : Post Oak Mall, GNC Space #3016, 1500 Harvey, C.S., TX Project # : AE08-381 Sample Number OIA 1 O1C Layer Acoustic Tile (Light Grey) Acoustic Tile (Light Grey) Acoustic Tile (Light Grey) 02A Floor Tile (Grey) Clear Mastic (Clear) Black Mastic (Black) 02B Floor Tile (Grey) Clear Mastic (Clear) Black Mastic (Black) 02C Floor Tile (Grey) Clear Mastic (Clear) Black Mastic (Black) 03A Floor Tile (Red/Grey) Black Mastic (Black) 03B Floor Tile (Red/Grey) Black Mastic (Black) NVLAP Lab No. 102056 TDSHS License No. 30-0084 Lab Job No.: 0813-08802 Report Date : 07/23/2008 % Of Sample Components 100% Cellulose Fibers Mineral Wool Fibers Perlite 100% Cellulose Fibers Mineral Wool Fibers Perlite 100% Cellulose Fibers Mineral Wool Fibers Perlite 96% Calcite / Vinyl Binders 3% Glue Binders 1 % Chrysotile Tar Binders 95% Calcite / Vinyl Binders 3% Glue Binders 2% Chrysotile Tar Binders 95% Calcite / Vinyl Binders 3% Glue Binders 2% Chrysotile Tar Binders 95% Chrysotile Calcite / Vinyl Binders 5% Chrysotile Tar Binders 95% Chrysotile Calcite / Vinyl Binders 5% Chrysotile Tar Binders Page I of 3 % of Analysis Analyst Layer Date 50% 07/23 JO 30% 20% 50% 07/23 JO 30% 20% 50% 07/23 JO 30% 20% 100% 07/23 JO 100% 2% 98% 100% 07/23 JO 100% 2% 98% 100% 07/23 JO 100% 2% 98% 5% 07/23 JO 95% 10% 90% 5% 07/23 JO 95% 10% 90% Steve Moody Micro Services, LLC PLM Detail Report NVLAP Lab No. 102056 2051 Valley View Lane Supplement to PLM Summary Report TDSHS License No. 30-0084 Farmers Branch, TX 75234 Client : Austin Environmental, Inc. Lab Job No.: 0813-08802 Project : Post Oak Mall, GNC Space #3016, 1500 Harvey, C.S., TX Report Date : 07/23/2008 Project # : AE08-381 Page 2 of 3 Sample Number Layer % Of iSample Components % of Layer Analysis Date Analyst 03C Floor Tile (Red/Grey) 95% Chrysotile 5% 07/23 JO Calcite / Vinyl Binders 95% Black Mastic (Black) 5% Chrysotile 10% Tar Binders 90% 04A Sheet Flooring (Tan) 95% Calcite / Vinyl Binders 100% 07/23 JO Yellow Mastic (Yellow) 5% Glue Binders 100% 04B Sheet Flooring (Tan) 95% Calcite / Vinyl Binders 100% 07/23 JO Yellow Mastic (Yellow) 5% Glue Binders 100% 04C Sheet Flooring (Tan) 95% Calcite / Vinyl Binders 100% 07/23 JO Yellow Mastic (Yellow) 5% Glue Binders 100% 05A Cove Base (Brown) 90% Calcite / Vinyl Binders 100% 07/23 JO Brown Mastic (Brown) 10% Glue Binders 100% 05B Cove Base (Brown) 90% Calcite / Vinyl Binders 100% 07/23 JO Brown Mastic (Brown) 10% Glue Binders 100% 05C Cove Base (Brown) 90% Calcite / Vinyl Binders 100% 07/23 JO Brown Mastic (Brown) 10% Glue Binders 100% 06A Drywall Material (White) 80% Glass Wool Fibers 2% 07/23 JO Cellulose Fibers 1% Gypsum / Binders 97% DW Paper Facing (Tan) 5% Cellulose Fibers 100% Texture (White) 15% Calcite / Talc / Binders 100% 06B Drywall Material (White) 90% Glass Wool Fibers 2% 07/23 JO Cellulose Fibers I % Gypsum / Binders 97% DW Paper Facing (Tan) 5% Cellulose Fibers 100% Paint (Off -White) 5% Pigment / Binders 100% Steve Moody Micro Services, LLC PLM Detail Report NVLAP Lab No. 102056 2051 Valley View Lane Supplement to PLM Summary Report TDSHS License No. 30-0084 Farmers Branch, TX 75234 Client : Austin Environmental, Inc. Lab Job No.: 0813-08802 Project : Post Oak Mall, GNC Space #3016, 1500 Harvey, C.S., TX Report Date : 07/23/2008 Project # : AE08-381 Page 3 of 3 Sample Number Layer % Of ISample Components % of I Layer Analysis I Date Analyst 06C Drywall Material (White) 90% Glass Wool Fibers 2% 07/23 JO Mica 1% Gypsum / Binders 97% DW Paper Facing (Tan) 5% Cellulose Fibers 100% Paint (Yellow) 5% Pigment / Binders 100% 07A Drywall Material (White) 50% Glass Wool Fibers 2% 07/23 JO Mica I % Gypsum / Binders 97% DW Paper Facing (Tan) 10% Cellulose Fibers 100% Joint Compound (White) 40% Calcite / Talc / Binders 100% 07B Drywall Material (White) 65% Glass Wool Fibers 2% 07/23 JO Cellulose Fibers 1 % Gypsum / Binders 97% DW Paper Facing (Tan) 15% Cellulose Fibers 100% Joint Compound (White) 20% Calcite / Talc / Binders 100% 07C Drywall Material (White) 10% Glass Wool Fibers 2% 07/23 JO Cellulose Fibers 1% Gypsum / Binders 97% DW Paper Facing (Tan) 60% Cellulose Fibers 100% Joint Compound (White) 30% Calcite / Talc / Binders 100% I "`sac A1� SMMS Asbestos Chain of Custody era seN` PLM-Bulk: ❑ Rush=l day ♦ Normal=2 day ♦ ❑ Extended []ANALYZE ALL ♦ ❑ POSITIVE STOP "Please call in advance for after -hour & weekend rush analysis" 1 ' 1 c PCM-Air: ❑ Rush( --same day ♦ El1-2day TEM-Air: ❑ 6 hr ♦ ❑ 12 hr ♦ ❑ 24 hr TEM-Bulk/Wipe/MVac: ❑ 24 hr ♦ ❑ 48 hr ♦ ❑ 72 hr. TEM-7402/Modified:❑ 24 hr ♦ ❑ 48 hr ♦ ❑ 72 hr Submitter's Name: Per. L.-) f / Sample date Project: FpS + 04 t4l a /I - N C / e4 se— —,,- Contact Information: Name:. Pa o I E-mail: (address): 1 Hard copy: (address): P.O. Box 3725, Bryan, Texas 77805 Invoice Address (if different): JZ z /le g �Gco l/efe Sf, i Page { of J Lab Job# — Lab Job# 0o?/ Lab Job# P.O. No: - ey ?r6ect No: A Ei!:� g .- .3'$ 1 Phone #: 979,778.2699 Mobile #: 979.492.5104 Fax #: 979.778.2730 'Please review paperwork and samples before submitting to lab. Uncontained /Improperly packaged samples or excessive administrative requests may Incur additional fees. ` Sample No. Sample Description V.91. / Area Location / Notes P, tL_L4 r kC roo O Z A ! Z / 247 r ® O �ZG 03-4 Z '' '' r •� l �!� lr Sao 60 3a� R sed by: DatelTime: >> ZZ/�S I7= Received BY: Datefrime: , Ja J)te/ 7- Released by: Datcrrime: 'Received By: Daterrime: Notes: Steve Moody Micro Services, Inc. - 2051 Valley View Ln. - Farmers Branch, TX 75234 - (972) 241-8 460 / FAX (972) 241-8461 NVLAP Lab # 102056 TX DSHS License # 30-0084 (COC 1007j I C;Yc�e M,,.. SMM��S Asbestos Chain of Custody i PLM-Bulk: ❑ Rush=1 day • NKOrmal=2 day ♦ ❑ Extended ❑ ANALYZE ALL ♦ ❑ POSITIVE STOP "*Please call in advance for after -hour & weekend rush analysis"* Company Name and City:Austin Environmental, Inc. Submitter's Name'q K 1� r %%// Sample date: Project: Fos n2 ails/ — N G / �e,:q.se .sue ce .-36, fl PCM-Air: ❑ Rush. same day ♦ ❑ 1-2 day TEM-Air: ❑ 6 hr 1• ❑ 12 hr ♦ ❑ 24 hr TEM-Butk/Wipe/MVac: ❑ 24 hr ♦ ❑ 48 hr • ❑ 72 hr TEM-7402/Modif14 D 24 hr ♦ ❑ 48 hr ♦ ❑ 72 hr ri P.O. No: Page Z of 3 Lab Job# aD� Lab Job# Lab Job# Project No: EOe — 3 B 1 Contact Information: Name: Brent Plant Phone #:_979.778.2699 E-mail: (address): brentplant@yahoo.com E Mobile #: 979.492.5104 Hard copy: (address): P.O. Box 3725, Bryan, Texas 77805 Fax #: 979.778.2730 Invoice Address (if different): 'Please review paperwork and samples before submitting to lab. Uncontained /improperly packaged samples br excessive administrative requests may Incur additional jets ""• Z O 8J , /SoG A4 r Sample No. Sample Description Vol. / Area Location / Notes dj elz Y o 44\ 06-AVie- r o0 40 o t c__ a�oG y'a b O Relea a by: Date/r'me: 'Received By: Dateli'ime: Released by: Date/Time: I Received By: Date/Time: Notes: Steve Moody Micro Services, Inc. - 2051 Valley View Ln. - Farmers Branch, TX 75234 - (972) 241-8460 / FAX (972) 241-8461 NVLAP Lab #102056 TX DSHS License 1130-0084 (COC 2007J 4 C A10C � SMMS Asbestos Chain of Custody i; r0 ser`` PLM-Bulk: ❑ Rush=1 day ♦ [ formal=2 day ♦ ❑ Extended ❑ ANALYZE ALL ♦ ❑ POSITIVE STOP **Please call in advance for after -hour & weekend rush analysis** Page 3 of f PCM-Air: ❑ Rus Lsame day ♦ ❑ 1-2 day Lab Jab# a pZ TEM-Air: ❑ 6 hr�♦ ❑ 12 hr ♦ ❑ 24 hr Lab Job# TEM-Bulk/Wipe/MVac: ❑ 24 hr ♦ ❑ 48 hr • ❑ 72 hr . Lab Job# TEM-7402/Modifi&E] 24 hr ♦ ❑ 48 hr ♦ ❑ 72 hr Company Name and City:Austin Environmental, Inc. Submitter's Name: Brent Plant / Sample date: 7/Z Z P.O. No: t_ Projec4!g l — iV G .30110 /Sa 0 a r Xg/ C S Project No: Contact Information: Name: Brent Plant Phone 4:979,778,2699 E-mail: (address): brentplant@yahoo.com Mobile #: 979.492.5104 Hard copy: (address): P.O. Box 3725, Bryan, Texas 77805 Fax #: 979.778.2730 Lnvoice Address (if different): **'Please "view paperwork and samples before submitting to lab. Uncontalned /improperly packaged samples or excessive administrative requests may Incur addittonal fees. Sample No. Sample Description ol. / Area t' Location / Notes b 7 �d i ti '� C C414�t D u ilepl 54.0 1 12ec A.` �0 78 _ S o r A 00,&, i I i i Rel=ed by: Date(r'me: Received By: Datelrime: Released by: Date/rime: Received By: f Date/Time: Notes: Steve Moody Micro Services. /nc. - 2051 Valley View Ln. - Farmers Branch, TX 75234 - (972) 241-84�O / FAX (972) 241-8461 NVLAP Lab #/02456 TX DSHS License # 30-0084 (COC 2007) City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved 10/06/08 514000-0001-0040 1500 HARVEY RD 3016 COLLEGE STATION TX 77840 POST OAK MALL POST OAK MALL, BLOCK 1, LOT 4A ,4C,5A, ACRES 53.148 GENERAL COMMERCIAL POM-COLLEGE STATION, LLC MALLTECH 812 336-3289 08-00002034 000 000 COMMERCIAL, REMODEL/RENOVATION NON-COMBUSTIBLE MERCANTILE B 'ding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL Date � $ ' Permit # Project Name 1 � Parve y 3�I<v COMMERCIAL CO Planning (Lindsay Boyer, Jennifer Prochazka, Jennifer Reeves, Crissy Hartl, Jason Schubert Grant Wenecl, Molly Hitchcock) Bridgette George Development Engineers (Alan Gibbs, Josh Norton, Carol Cotter) City Engineer (Bob Mosley, Jerry Jones, John Logan, Robert Bumpurs, William Ethridge) Environmental Services -h (Eaphrame Thomas, James Boykin, Pete Garcia) r� Fire Department v� (Eric Hurt, Eric Dotson, Jerry Duffey, Steve Smith) Drainage (Donnie Willis) Public Works - Sanitation (Wally Urrutia) EIectrical Services (Tony MidWsky) Water/Wastewater Services (Joe Mike Garcia, Paul Schoenfeld, Mitchell Carson) Miscellaneous Notes _. . (10/6/2008) Beth Boerboom - Re: Calling for C O_ @ 1500 Harvey Rd #3016 Post Oak Mall GNC Remodel m Page 1 From: Mitchell Carson To: Alan Gibbs; Benjamin McCarty; Beth Boerboom; Brenda Godfrey; Brent R... Date: 10/2/2008 7:32 AM Subject: Re: Calling for C.O. @ 1500 Harvey Rd #3016 Post Oak Mall GNC Remodel OK for CO ...... Mitch >>> Gina Southerland 10/01/08 12:44 PM >>> They are looking for a C.O. on Fri. Oct. 3rd. contact person is Trudy @ 812-360-4552 BP# 08-2034 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.gov (10/6/2008)'B6th Boerboom Re: Callirig for C b. @ 1500 Harvey R0'#3016 Post Oak _MallGNC Remodel Page 1 From: Pete Garcia To: COS Date: 10/3/2008 12:07 PM Subject: Re: Calling for C.O. @ 1500 Harvey Rd #3016 Post Oak Mall GNC Remodel Attachments: Pete Garcia.vcf They are OK 'Do not ask the Lord to Guide your Footsteps if you are not willing to move your Feet' This e-mail and/or attachment is for the sole use of the intended recipient(s) and may contain confidential and /or legally privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all electronic and paper copies of the original message and any attachments. Thank You. >>> On 10/1/2008 at 12:44 PM, in message<48E370A2.2D9C.0039.0Ca>cstx.gov>, Gina Southerland wrote: They are looking for a C.O. on Fri. Oct. 3rd. contact person is Trudy @ 812-360-4552 BP# 08-2034 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.gov (10/6/2008) Beth Boerboom - Re Calling for C.P. @ 1500 Harvey Rd #3016 Post Oak Mall GNC Remodel _. Page 1 From: Rodney Harris To: Alan Gibbs; Benjamin McCarty; Beth Boerboom; Brenda Godfrey; Brent R... Date: 10/2/2008 8:37 AM Subject: Re: Calling for C.O. @ 1500 Harvey Rd #3016 Post Oak Mall GNC Remodel No Sanitation Issues. Rodney Harris Sanitation Foreman Public Works Tel(979)764-3698 Fax(979)764-3489 email: rharris@cstx.gov >>> Gina Southerland 10/1/2008 12:44 PM >>> They are looking for a C.O. on Fri. Oct. 3rd. contact person is Trudy @ 812-360-4552 BP# 08-2034 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.gov PREPARED 10/01/08, 12:07:45 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/01/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 1500 HARVEY RD 3016 SUBDIV: POST OAK MALL CONTRACTOR MALLTECH PHONE (812) 336-3289 OWNER POM-COLLEGE STATION, LLC PHONE PARCEL 514000-0001-0040 APPL NUMBER: 08-00002034 COMMERCIAL, REMODEL/RENOVATION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B125 01 10/01/08 BLDG, FINAL TIME: 17:00 J.l'1 C October 1, 2008 12:05:50 PM glsouth. COMMENTS AND NOTES 0� PREPARED 10/06/08, 8:37:39 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/06/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 1500 HARVEY RD 3016 SUBDIV: POST OAK MALL CONTRACTOR MALLTECH PHONE (812) 336-3289 OWNER, POM-COLLEGE STATION, LLC PHONE PARCEL 514000-0001-0040 APPL NUMBER: 08-00002034 COMMERCIAL, REMODEL/RENOVATION ------------------------------------------------------------------------------------------------ PERMLT: ELER 00 REPAIR/ALTERATION ELEC PERMIT SUB: LEX TEX INC (979)773-2264 REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ E100 01 9/15/08 OC ELEC, UNDER SLAB TIME: 17:00 9/15/08 AP September 15, 2008 11:01:16 AM bboerboom. Put in PVC pipe in 7-8 ft of slab. Please call Robert at 542-8148 before heading over. E135 D1 9/26/08 DS ELEC, CEILING COVER UP TIME: 17:00 9/26/08 AP September 26, 2008 8:51:05 AM glsouth. E150 01 10/06/08 ELEC, FINAL TIME: 17:00 October 6, 2008 8:37:18 AM glsouth. -------------------------- y-�-------- COMMENTS AND NOTES-------------------------------------- flf50 BUILDING PERMIT CITY OF COLLEGE SOTATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 08-00002034 Date 9/10/08 489522 1500 HARVEY RD 3016 514000-0001-0040 R38018 COMMERCIAL, REMODEL/RENOVATION POST OAK MALL MERCANTILE GENERAL COMMERCIAL 39100 Owner Contractor POM-COLLEGE STATION, LLC MALLTECH 2030 HAMILTON PLACE BLVD 1128 S. MORTON ST. STE 500 BLOOMINGTON IN 47403 CHATTANOOGA TN 374216000 (812) 336-3289 --- Structure Information 000 000 TENANT REMODEL Construction Type . . . . . NON-COMBUSTIBLE Occupancy Type . . . . . . MERCANTILE Other struct info . . . . . IMPACT/PRORATA FEES PAID NA HEATED AREA 1552.00 INTERIOR WALL TYPE SHEETROCK SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 597930 Permit Fee . . . . 210.00 Plan Check Fee .00 Issue Date . . . . 9/10/08 Valuation . . . . 39100 Expiration Date . . 3/09/09 Qty Unit Charge Per Extension BASE FEE 15.00 39.00 5.0000 THOU BLDG, VAL 1001-50000 195.00 ---------------------------------------------------------------------------- Special Notes and Comments THE TEXAS DEPARTMENT OF HEALTH REQUIRES AN ASBESTOS SURVEY IN CERTAIN CIRCUMSTANCES - CALL TDH @ (254) 778-6744 FOR MORE INFORMATION Shall advertise only the name of, uses of, or goods or services available within the building, or tenant lease space, to which the banner is attached. Shall be mounted parallel to the face of the building. Shall not be cantilevered away from the structure. - --------------- ---------------------------- - ----- - -------------- BUILDING DEPTJ EPRESENTAT E: ' - APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: '(979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00002034 Date 9/10/08 Application pin number . . . 489522 ---------------------------------------------------------------------------- Special Notes and Comments Shall not extend more than one foot from any exterior building face, mansard, awning, or canopy. Shall not obstruct any window, door, stairway, or other opening intended for ingress or for needed ventilation or light. Shall not be attached to any tree, fence, or public utility pole. NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY, WATER SUPPLY LINES SERVING THE THIRD FLOOR OR HIGHER, AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394 PROVIDE COMBUSTION AIR: FOR GAS -FIRED APPLIANCES 'PER SECTION 304 OF THE 2006 INTERNATIONAL FUEL GAS CODE; FOR OTHER FUELS TO COMPLY WITH CHAPTER 7 OF THE 2006 IMC. *ALL UTILITIES MUST BE DISCONNECTED BEFORE DEMOLITION BEGINS. PLUMBING SEWER LINES MUST BE CAPPED TO AVOID STORM WATER FLOWING INTO LINES. MAINTAIN SAFE JOB SITE AND REMOVE ALL DEBRI PROMPTLY. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR REQUIRED EXIT DOOR(S) SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND RETURNED PROVIDE FIRE EXTINGUISHERS) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC) SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -` - - - - - - - ------- BUILDING DEPT IEPRESENTATIVI: 1 APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: '(979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00002034 Date 9/10/08 Application pin number . . . 489522 ---------------------------------------------------------------------------- Special Notes and Comments *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit Shall advertise only the name of, uses of, or goods or services available within the building, or tenant lease space, to which the sign is attached; Shall be parallel to the face of the building; Shall not extend more than one foot from any exterior building face, mansard, awning, or canopy; Shall not obstruct any window, door, stairway, or other opening intended for ingress or for needed ventilation or light; and Shall not be attached to any tree, fence, or public utility pole. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT INTERIOR LIGHTING SHALL MEET THE CONTROLS AND WATTAGE REQUIREMENTS OF SECTION 505 OF THE 2006 INTERNATIONAL ENERGY CONSERVATION CODE. CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR'TO COVERING ANY WORK Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 210.00 210.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 210.00 210.00 .00 .00 ----------------------------------------------------- ------------- BUILDING DEPT REPRESENTATIVR: APPLICANT:- 1^1 /'Lr.+rairaq c^-1?va�In�+mrxa tirrr:,r�Nt ADDRESS/LOCATION APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX ?'s(/- l w �i WWW.CSTX.GOV CAII f- 16 -aa t/Ae va) 1ACC OnlyDATE:&rn• REG APPLICATION # _- Z-54 TEMP POLE # 41,1110- �AA li _ 771ya LOT BLOCK SUBDIVISION /J� , SEC/PH BUSINESS/OWNER NAME: a, mfy t Ndr -L% GN �K/ PHONE: r I 'r J Q Oq 75� CONTRACTOR/HOMEOWNER: PHONE: CONTACT PERSON FOR REVIEW COMMENTS: PHONE:/�� �� O p / 74 FAX: Y 33g� D O EMAIL: h�i�Gio�/tOkI.SRSI `'�I�, eoeon ELECTRICIAN: HVAC: ACCESSORY/STORAGE ADDITION DEMOLITION (ASBESTOS SURVEY) DUPLEX (LANDSCAPE PLANS REQUIRED) LOCATION RETAINING WALL DESCRIPTION OF PROPOSED USE: STRUCTURE USE: PLUMBER: GOOD CENTS (Residential only): MOVING RE -ROOF NEW CONSTRUCTION* SHELL ONLY PORTABLE STORAGE (RESIDENTIAL) SLAB.ONLY PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL EMODEURENOVATION* TENT © HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: s� ^ TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION NO. EABPR.J I • VALUATION: $ 39 , /0O. 0 0 TOTAL AREA: S� sX HEATED AREA: (Cost of Labor and Materials) 175( PUBLIC SEWER SEPTIC/TREATMENT SYSTEM . SEWER TAP: WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE SIZE SIZE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: SIZE ROOF TYPE. - SINGLE DOUBLE F—] TRIPLE ATTACHED DETAC u CA POALI / SIGNATURE OF APPLICANT: *If proposed work involves new commercial con n or facade i v ments/renovations to an existing commercial property, building elevations are required. ........................................................... _ Official Us N Comments: E or NO Plans Examiner Zoning Official (kgj-,City of College Station Pa a of � Building Inspection Department g PLANS EXAMINATION REPORT Address: 1 -7(e� Y ve Z 3016 Date: — O S Project Name: ,,7 �1 L /�os�-u�/Q // Drawing Code Number Ref. Number Questions or Comments u-•- �•-z CAL oo CG Received by: Date: CITY OF COLLEGE STATION July 7, 2008 Re: GNC- 1500 Harvey Road- Post Oak Mall, Suite # 3016 Dear Mr. Robert Dobnowsky, I have completed the plan review for the above referenced project and have the following comments. The plan review is based on the 2006 International Codes, the 2005 National Electrical Code, ANSI A117.1-2003, and our local amendments. Where appropriate, I have included the applicable code sections. 1. Submit an Asbestos Survey of Suite # 3016. 2. Submit ComCheck 2006 IECC for Lighting Load. 3. Submit Fire Sprinkler and Fire Alarm plans to Fire Marshal's Office, 979- 764-3705, for separate review and permit. The review does not include any civil or zoning issues or NRA requirements of the Unified Development Ordinance. Please respond to the plan review comments at your convenience. Documents addressing these issues will be required. Should you have any questions, contact me at 979-764-3754. Thank You, Ben McCarty Plans Examiner the heart of the Research Valley P.O. BOX 9960 1101 TEXAS AVENUE COLLEGE STATION • TEXAS • 77842 979.764.3510 www.cstx.gov CITY OF COLLEGE STATION' Planriirtg er D'evelopment Services. 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET Date: # of pages including cover: 2— If you did not receive a complete fax, please call our office immediately for a new transmittal. TO: hod sky FAX: y 1)-— 33 9— 2% 0 7 COMPANY: G NG RE: G Al L s-loYe 0-Le Kea / 5-0 o,.� le FROM: eh ia�'� Mc.�ar COMPANY:_ City of College Station REMARKS: ❑ Urgent ® For your review ❑ Reply ASAP ❑ FYI o TRANSMISSION VERIFICATION REPORT DATE J I ME FAX NO./NAME DURATION PAGE(S) RESULT MODE TIME 07/08/2008 08:52 NAME FAX TEL SER.# 000L5J596800 07/08 08:51 914123388878-40681# 00: 00: 26 02 OK STANDARD ECM 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 'hone 979.764.3570 / Fax 979,764.3496 FACSIMILE COVER SKEET Date: ) ( a 2Pog # of pages including cover: 2-- If you did not receive a complete fax, please call our office immediately for a new transmittal. TO: 134 FAX: / 3 3 0— 9 0 7 COMPANY: & IVG RE''_ 6A16 , .. P05+ c6k FROM: q �'. h mGt", A.Y COMPANY: City of College Station - - - r -7 - - r. --, -