Loading...
HomeMy WebLinkAboutRES2008-02031, 08-2032�o���'�► WF1054402 / 001 City�of College Station PAGE 1 REQ. DATE: 07/03/08 07/03/08 13:53:31 LOCATION: 2722 SILVER OAK DR LOC ID: 211800 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: 4" SWR 3/4" WTR ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 07/03/08 SCHED COMPLETION: 07/03/08 ******************************************************************************** JOB ORDER RESULT COMMENTS PREPARED 5/04/09, 12:01:12 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/04/09 ------------------------------------------------------------------------------------------------ ADDRESS . : 2722 SILVER OAK DR SUBDIV: SONOMA PH 2 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 578700-0202-0260 APPL NUMBER: 08-00002031 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/15/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00 7/15/08 AP July 15, 2008 9:36:52 AM acarter. Strings up. Slab ground installed. B145 01 7/22/08 BB BLDG, EXT. SHEATHING FASTENER TIME: 17:00 7/22/08 DA July 22, 2008 10:59:33 AM acarter. No ext. sheathing up �B145 02 7/23/08 BB BLDG, EXT. SHEATHING FASTENER TIME: 17:00 7/23/08 AP July 23, 2008 10:11:29 AM ccourt. B115 01 8/20/08 BB BLDG, FRAMING TIME: 17:00 8/20/08 DP August 15, 2008 4:33:42 PM glsouth. Need OSB bracing with nailing pattern on wall between front room and kitchen and wall between garage and bedroom. Need joist hangers by attic entrance. Contact office about stud straightening. B115 02 8/25/08 BB BLDG, FRAMING TIME: 17:00 8/25/08 AE August 25, 2008 11:31:32 AM glsouth. Need to double cut studs on OSB braced walls and block behind splices on same walls. Both by insulation. B130 01 8/26/08 RH BLDG, INSULATION TIME: 17:00 8/26/08 AP August 26, 2008 9:50:55 AM acarter. B132 01 8/28/08 RH BLDG, SHEETROCK FASTENER TIME: 17:00 8/28/08 AP August 28, 2008 10:51:10 AM ccourt. B125 01 11/12/08 BB BLDG, FINAL TIME: 17:00 11/12/08 DP November 12, 2008 10:12:41 AM ccourt. Need to post energy requirements in electrical panel. Need depth indicators through out attic. Make sure attic insulation meets depth requirements. No irrigation. B125 02 5/04/09 BI $8 BLDG, FINAL TIME: 17:00 A? May 4, 2009 11:25:15 AM glsouth. -------------------------------------- COMMENTS AND NOTES -------------------------------------- /� Date: 5/4/2009 Inspection Comments for Finals Permit Year: 8 Permit Number: 2031 Address: 2722 SILVER OAK DR Inspection Result Comments Strings up. Slab ground installed. Need OSB bracing with nailing pattern on wall between room and kitchen and wall between garage and bedroom. Need joist hangers by attic entrance. Contact office about stud straightening. Need to double cut studs on OSB braced walls and block behind splices on same walls. Both by insulation. Need to post energy requirements in electrical panel. Need depth indicators through out attic. Make sure attic insulation meets depth requirements. No irrigation. No ext. sheathing up Page 1 b Date: 5/4/2009 Inspection Comments for Finals Permit Year: 8 Permit Number: 2031 Address: 2722 SILVER OAK DR Insp. Type Inspection Type Code Description Insp. status B100 BLDG, FOUNDATION -SLAB IC B115 BLDG, FRAMING IC B115 BLDG, FRAMING IC B115 BLDG, FRAMING IC 6115 BLDG, FRAMING IC 6115 BLDG, FRAMING IC B115 BLDG, FRAMING IC B125 BLDG, FINAL IC B125 BLDG, FINAL IC B125 BLDG, FINAL IC B145 BLDG, EXT. SHEATHING FASTENER IC Page 1 Aug.14, 2008 1;22PM S t Y I e c r a f t Builders, Int, No. 5184 P. 11 rat Shielding a& Protecting Homes Against Pests" Renewable S Year Subterranean Termite Retreatment Agreement (Does not cover any other species of Termites) This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph). CEtonfer Name Date Billing Name if different , &9 P/vCA DAJC Street Address of treated structure Billing Address if different City state zip Code City Homo Phone Work Phone Type of Treatment Partin! Bait V Pre -Treat Treatment for: X Prevention Control of Subterranean Termites Notes: State zip Code Initial Termite Cost S Ov Additional Renewals Paid___ Other ....... ... _ Tax Cash_Check# Total SWE Payment 5 Balance $! Credit Card: _ Type Exp. Date Card Plumber S Year Subterranean Termite Retreetment Grt$rsn[ee:. ,RP Lee Termite and Pest Control will retreat the structure for Subterranean Termites at no cost to the customer, if at infestation of Subtcnwcan Termites is found, as long as the orginal treatment is paid in full and the customer is current on their yearly renewals. This Agrccmcat will expire in one (1) year unless the customer elects to pay the yearly warranty fcc. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Tcrmitc and Pest Control may approve additional warranty years after the five (5) years with an additional increase in the yearly warranty fee. The guarantee does not cover any damages to the structure or contents of the customer. The customer agrees to control all condusive conditions that may cause reinfestation_ If the structure is modified, added on to, altered, or if the soil treatment around the structure is removed the customer must contact.RP Lee Termite and Pest Control and pay for additional treatment in order to keep the guarantee in effect If the customer does not pay for additional treatment the rotreatment gttatamtoe can be cancelled. go Renewal Fer Customer may elect to renew the rctrcatmcnt guarantee for additional years. The renewal fee is S 1. Plus tax. The renewal fee is due on or before the annual anniversary date or paid $_ Z plus tax every third (3) month with inspection. Mli1Rffi1niAg the Guarantee: The customer agrees to correct all conducive conditions, at owner's expense, as they exist or as they occur in the future in order for the guarantee not to be cancelled. Customer will make the structure available for inspections and treatments as requested by RP Lee Termite and Pest Control. Re_. inrtnee9m RP Lee Termite mid Pest Coutrol will reinspect the structure at customers request or any other times RP Lee Termite and Pest Control deems necessary. RP Lee Termite and Post Control recommends that the customer call and set up an annual inspec- tion at the time of customers yearly renewal. 3bp2This agreement may be transferred to a new owner with the payment of a transfer fee of $ _ , copy ofthe Wood Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest Control. Thisite RetreaznrpattSivarantec does not prevent and is not intended to control other_fnrms_oLTermites D?D�ttRlltiEQrmnsan.�ic.l. Wood Baring Beetles, Carpenter Ants, Carpenter Bees, Wood Rot, Fungus, Decay, or any other hood destrgong insects or organisms, Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration Association, The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final, binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration Act Limitation of lLjah = Laodwapiug and grass next to the slab may be damaged during treatment, carpet may need to be pulled up in certain areas around the home, drill holes may need to be made in floor coverings such as file or 1molcum or in cabinets next to pipe areas, and holes may need to be cut in walls. Customer agrees not to hold RP Lee Termite and Pest Control liable for these damages, or treatment techniques, or other damages that may occur during treatment. Agreement: This Agreement shall be the entire agreement between customer and RP LeeTermite and Pest Control. If any part of this agreement is found to be invalid it sball not affect the validity of any other part of the Agreement. Mare licensed by the Structural Pest Control Board - 333-Guadaluge. Spite I-330 Au$tlll• TX 78701512-3054250 RP Lcc T yi & Pcst Control Cert. Apl.# tomer gzature Date Aug,14, 2008 1:22PM Stylecraft Builders, Inc. No. 5184 P. 10 New Construction Subterranean Termite Sail Treatment Record this term is cornaloiad by tho 11conood Pact Cantriol Corymny--- oxbllnp data wusas, QaMtV ald rnaklCan09 !ho data n"a and a M], h4ma to WNn b4lterrta. XVG +nal' not tvtlot4 H; id=Wdon, anti you am nulr W. OMD Appioval Nu. 2.;U',P5 taxp. 1LV317=51 1b MRul0t pat r2tpaa4G, trlt U-Wa, Ib1 kW Iw-1Q4Wk irvj 4Vlit �l�C ' fuYrChtn9 -r ' slid tovlawlnp Ma ooloO= at tnlMUlAn nos mlarnr ms b mandatory and it rsquIrad ID cmpl9to 1r1t3 tutm, uN000 it WpLry: A eurrcut/ mid CUB conoot Gv;,J n Z4 C.FA 200.11204(b)(J)1*;UMt that the etas jar HUD hwt od atn aWm mot Lv L99 ut Wrmlto traxards. 7W-3 1111MW-liOn collo:�an rogU1n73 tho Widw to 'S.e:W Crot Ag =,tartCp4 iamt C oftfA <&MWW porkxmod aJ! raqutrod leatTau tar laws m, mru Mat Ula Wadcr W uu► vw lilt uaotad am ipma trdastasi% ttu aro year. Qu6dgra, Para eontmt crzr>jrutloe. nlorglago larxtan, tratretx,ynr>, anrj tfi-�G ss a retard ut troatmon; to ry�otitie uuawa ror� oeo uw ur�urarayvn CoicttW. iUo Int«matlen c nd aw idpmd a-*C,dor"-- Tnm,orroct1saWa Wdlar1r+rortrlau,7narpnrVoMto111aCullderonptOpOtAC(now)mnnlrucharcnxOswhar.-zoo trowmonlJar pradanLonac�5tyr+insan tormit+ WozLUL�n to spa4lttod by 5110 bul!46r, arcldlta011, ru roqu,ruJ by the tdrulur, ivehliact. FKA. or VA. AU purl M16lot anrvicoa GM WrNuar. Jto 1'03t Cannot operator and al Ider_1rntGR; tlothd o:hanviaa. &ollao 1; Gonor*J Inforrnatlal (Ttealilig GCrnpa117 int9rrT1001i) Company N9rtto Ct rrv7dC_ or- ComwYAd4rea 0 , "� 9N� .; �y , 5 st:uD _.� zip Z Company Bu no" t)r5rutcs tio. Gumpary Pttorvj W. FNMA CAN No. (H any) Soutierr Ta Gu11dof 1nlLYt114110 t Company Namo Pnana No. 64Cfop a: Prop"ly tnlcxlrlation Lgoatim aj.5%,abxq (a) itoutvtl (,Shot A1ktom w Logal DbMilptlon. CO, StdD gnu Zip) T}pa 01 Gortatruotion (MWA Man tam WA may tm 9W.ua) 4X71 :lab 7-1 13usamuu+ Crawl (� Otror- _ Y App"mato Oap&h 01 Footing: Qruido Typo of Fill Sostlpn 4: Trma=rA Information p:t0(s) of Traaimlrnt(c) -�, 1 7 grand M.1MS or Product(;) Usod - ° �'-------- - - AfFroldmalp Final Mix Soluttun °Jia Apprattlmato VZo 01 Trcafmont Arao: 41L Ur=r IL Urcar t:. 01 trtaconry VO4ju�— /4 lr0xlmslo Total OW101ts of goligiml A ,i10d Was iroolmOM g9as;(atod on oxtsdo-1 Yot No 5&vk* Apro=0P%Ava&49o7 IM Yes EJ No We. C-Ma 490lawa roquiro oorvico agroomants to ya;taual Thal rolm x1vos nul proompt atato lair. At= nrnu (t.>3q No trl Applt�atod5) CKUPtatlm No. of rogtllrcd by State trarl) G• f71&p Tim appovator tut& toed a x4val to 4w0n1011G» w2h;Ito product tahol And stato ttgulrornanit. All veatn,un: awlormt :lhd mothafs usod comply whh sUla and World re!pfil ions. Authortaod tirunolury ivoT NIX wil ormoc= 104D 49W.. reu r-olin NPCA-00-9 may till bv UC-0d .•n31a4 1;i UtmkW ;jW,1r ei•,1 nuts rnlrl 1hty; 3t ll.,l,r:. Xrx ru,inHUD-11RCA91}3 (W.20W) Aug, 14, 2008 1:22PM S t y I e c r a f t Builders, Inc. No, 5184 P. 12 SUBTERRANEAN TERMITE PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATE Licensed and regulated under the Texas Structural Peat Control Act RP LEE TERMITE & PEST CONTROL PO Box 9423 • College Station, TX 77842 • (972) 690-8622 • TPCL #11486 — CUSTOMER INFO ON: -- - .-~ -7 Name: C .=7" Phone At: Phone ##2: Address: efty: C',5 state; 77 Zip Code: ' y5 Location to be Treated: For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember that your architects or design engineers speellfeatlons must also be followed, unless they are in violation of the law. Review the consumer information shoot for further information. If you have any questions, contact the nest sanki l eamnan' or the Texas Structural Pest Control Board, P.O. Box 1927, Austin, TX 78767-1927. Telephone number (512) 305•8256. Before conducting a termite prownstructlon treatment, the company will present a complete diagram of the structure including constNoton details. When construction prevents performance of a full treatment, in accordance with a bid for full treatment, any change to a partial treatment by the company providing the treatment will be permitted if the owner of the structure or the person in charge of the construction and the certified applicator for the pest control company sfgn a statement attesting to the construction conditions, The agreement must be attached to the contract with an amended diagram showing the exact areas to be treated. Copies must be sent to the owner of the property within seven days of the application. notes: *0'cAfe- ,, /dc— c,�r4fe yr 646 & e.d rp O a rU );M o Sao Rt3 vev r ""'f DC Type of treatment proposed: (check all that apply); ❑ Full � Partial iWood ❑ Bait Q Commercial VSingle Family Total square feet to b treated:- -' . Total Ilnaar fast to be treated: !9/0 . Approximate measurements of structures) to be treated: y/4 A label of �04ACtode, termiticide(s) is attached. The percentage of the termiticide(s) to be applied at this location Is Estimated amount of termiticlde to be applied: a?/GMZ^ gallon(s). THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED ON BACK (SPCB104). THE BOARD APPROVED SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT SERVICE. Complete details of warranty (If any) including time period of warranty, renewal options and cost and obligations of the contacting parties Is attached. If the warrantydoes not include the entve structure treated, the areas Included In the warranty are (specify): A consumer information shoat is also attached. 9Na Y tyC -+a giZ JCS dUv�C� Signature o& or Technician Printed Name Liate S nature of Offlomer Verifying Receipt of This Document Date rrEm N sT • rww oixw7 White Copy, Service Provider Yellow Copy -Customer F" D*a and �nnm saiwcawu cammwcinorrs a-eeGrata�a, oaks, TX il zaor Service Treatment Invoice Route: _ Map Code: Sf1lrtTime: am/put Rubli7lme: amlpm Type of Sen•ice: (F.HL Regular Follow Up One 79me Charity Service Address Name: Address: Y- I xZ �,'IVc�. QAW, City: 6 ,1) Tx -73XO Phone: Billing; ;A I L 617�- 92 Daft: ea'��"� Appoint.l5me: W aurlpm Fmiueney, idbf Q S V structunn 61d CriM'] PIB Comb. Pets: Dog(s) Cat(s) Bird(s) Fish ,hN V-r' Cost of Service ram $�ZD•' '_ t' a•: f Tax $ '' Payment by: Total Due $ Q- Cash ❑ Payment S Check ❑ # Balance 5 Credit Card U PEST PROBLEMS: lAP1 r' ;fir DIRECTIONS 11NSTRUCTIONS: EQUIP. METH. LOCATION(S) PRODUCT WOOD DESTROYING INSECTS QTY TARGET PEST(S) PAYMENT DUE UPON RECEIPT termkiarSC-XiprrrrLL.O6°lo Subtcrranr+aTermiles,Aals Sixeel'Unk Posird 1�rmidorSON=171prodl.460/6 SrMerraneanTernitm SIM OfTank Pootod tAJ1' /?i ISara-car�bJsrdlwn Uciahornte Telraltydate 50% SobterrarpdFornwesrktDr}ti+nadlbvmitra, Crrpmter Ants, Beetles, Pealed I_ GENERAL j'FSTS lnvaderHPH-Baygoa 1% CarpenterAnts, Spiders, Crickets, AliWpedm, Beetler, Imnites. Demon W P-jyano-PhwwXyphe"1 Cockroaches, h11111potim So»bogs, Flies, 71cks, Atosqullas, P111buV6 DLnelhyc)leyeloproparocarbagfirto1% Sli erfish,Secs,Ante,CarprnfirAnis,Seorpknac,Spldera. Thorpe Ultra WP-Cytic i la .025% (Rest) Ants (Except Pharaoh), Cockroaches, Crickets, Earwlga, Xlilllpedes, Mica, Frolt Flies, Beetles, (gen. surfsee spray, spat, mhi, creek & crevice) Piltbegs, SINuEah, Spideva, Gnats, Harnett, Wups, Ydluw Jrckeis. TalstarBZD othrla.2% Ants,Centrpedes,Cockmehes, Crickets, Cramhopper%SvorpWm6'1Uka,Silverfish, Spidery. Moxf6rce-Hydrametkykw [%-2.15% PhrrrakAnts, Crkke% Carperder Ants, Lg, ttoaches, Variety of Ants. Qykick CS Cytluthrir .O5% Spiders, Scorpions, Ants, Carpeutw Auts, Cmrperter Bees, Roaches, Crkkels, Silverfish. Phaatan.5% PharohAnts, Variety of Ants, Roaches FLEAS 7Ii agsrtl�Pcrmelhrin S% F1eas, Ticks, Ants, Ccntlpedes, Carpentw Ants, Decs, Wasps, Crrpenter Hecs, Cockmehes, Crlekets, Flies, Earwigs, Mklipcdes, Beetles, Pillbugs. Suspend SC-Deltanchrrir 4.75% (RWJ) Hess, Beeo,Beetles, Roaches, Crickets, Lim, Flies, Scarpions,'llcks, Wasps. Nygaard-bletkyiehrosy ]Or% (RM) 1GR-Gruwlh Roackrs, Crickets, Mying lmecls, Stored PrWuct Pests. Excite R Pyrethrin .05% MICE. RODENTS. RATS. MONITORS Fleas. Fas4rac4lroarethalln .01% Alice, Rodents, Rats. Bait StaAOa-LorgeNnmdl Glue Boards OTHER Olio, Rodents, Rats, Beg Monitors. Pea-Ceotrul Plus YynttArles.50% Heaaedlies, Aiwgdros, Malha, Fleas, ►Yasps, i[oromts,'IScks, Cockroacies. nlast lam Bifentkrin Jt6% Spiders,Anis.Roacies, Sliverfish, Hamigs, Flees, Scorpions F4uIRMWI: A -Compressed Sprayer P-Power Sprayer W13ait Dispenser BS-Bait Station UT -Bait Trap D-Aerosol Can G-Glue Board H-Hand Duster SSpreader F-Foaer Fr41-Foamer AC-Actisol unit Other L,quJil s, I-Kicelm 2-[Wh(s) 3-Bedrooms 4-DiningRoom 5-4J61ity 6-Slorago 7-CoromonAteas 8-Garage 9-PeiimererofS1ruc1v= 10-Attic II -Yard 12,UaderHome 13-Warehouse14-018oeM xposedWood2'tipfinmSlab Other Diethnd of 1lratmenta: CC-Cruk & Crevice SS -Sul) -Slab Injection VT-Nbid Treatment BP -Bait Placement RS-Broadcast Spray PB-PerimeterBorier BV-Brick Venire WF-WoodTmaiLment PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried. W Licenced by the Texas De artmeut of Agriculture Structural Pest Control Service - P.O. Box 12847 - Austin, TX 78711- 512-305-8250 SERVICE TECHNICIAN; Ci a �,�/ CUSTOMER SIGNATURE: r -*r .f.et, e-v o-�X. DATE: g%0b se review the Customer Information on the other side of Invoice P.O. Box 9423 • College Station, TX 77842 • (979) 690-8622 • Fax (979) 690-8840 08115 THIS SET OF DRAWINGS FOR A HOME 15 THE COPYRIGHTED PROPERTY OF STYLECRAFT BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL OR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF THE DESIGNERS. PLAN TYPES S = SELECT SERIES W = WAINSCOT WITH SIDING F = MASONRY ON FRONT 3 = MASONRY ON THREE SIDES 4 = MASONRY ON FOUR SIDES G = GOLF CART GARAGE E = ELITE COLLECTION C = COLLEGE HOUSING A = ATTACHED TOWNHOME D = DETACHED TOWNHOME X = DEVELOPMENT Z = CUSTOM HOME FRONT ELEVATION FLOOR PLAN SHEET INDEX G-1 COVER SHEET C-1 SITE S-1 FOUNDATION S-2 WALL FRAMING S-3 FLOOR PLAN S-4 DETAILS S-5 JOIST FRAMING S-6 ROOF FRAMING S-7 ROOF S-8 ELEVATIONS E-1 ELECTRICAL P-1 PLUMBING A-1 TRIM/CABINET A-2 FLOORING COMMENTS FRAMED AREA LIVING TOTAL 1443 SF GARAGE 369 SF PORCH 40 SF FRAMED TOTAL 1852 SF M m 0 CD a j l7P a� � 3x�v !, evrp= ON dP N To �o,3 `nvVC" JOB#: 08115 0 Q U 0 w ry w V-) J N CV CN STIMATINC CREATED: AJ 6/ 13/08 PRE -CON: 6/20 REVISED:6/24 ISSUED: PRINTED: 6/24 Q Co w � > O co U d- r— r-- SCALE: 1/B. 11x17 G-1 1/2" 11 GMOOIH DOWEL LONG W/ we CAP - PUCE IN SIAB OR DRILL 9" INTO EXISTING CRADE BEAM. TAPE CAP TO IFAK i00L EDGE E.J.T. 1' O END OF ROD THICK PAv1NG 3000 O 10" O.P. REINF. W/ # SE MID DEPTH USE CHAIR SUPPORTS DISCONTINUE REINF. O U. 1x REDWOOD DMDER D SECTION "DS CONDNUE REINFORCEMENT HROUGH KE-AY ONE CHAIR A" THICK PANNG Z..PSI 5O. ff.REINF. MPNR W/ #3'f O 0" O.O .W. MID DEPTH USE CHAIR SUPPORTS C SECTION "C"II.5 3/0" DN. DOWEL W/ SIEM. DRILL INTO E%ISTINO SIDEWALK tx REDWOOD DMD B SECTION "B" 3/0" Do, OOwEL W/ SLEEK DRILL INTO E%STNG CURB W/ a 15 REBM A SECTION "A,3. d �. d. d a d CONTRACTION JOINT C a d INSTALL EXPANSION JOINT 0 MID -DRIVE IF OVER 45' a d d d LY PROPERTY LINE ° ° ad C d °d 4" THICK 3000 PjI ON CBC. B REINFORCE W/ Z{3 ARS d ° 0 18" O.C.E.W. OFRI DEw LK� CITY SIDE WALK IN Ft LD 0 O B MAIL BOX I l s -n- LAYDOWN CURB DETAILS CONTRACTION JOINT WHEN DRIVE < 16' WIDE 4" THICK 300� PSI CONC REINFORCE W #3 BARS 0 18 O.C.E. . CONTRACTION JOINT INSTALL METAL KEYV�AY EXP. JOINT W/ 3/ DIA. SLICK DWLS. 0 18 O.C. W/ SLEEVES ONE SIDE 2722 SILVER OAK DR. SONOMA PHASE- 21 BLOCK- 21 LOT-26 4'1 SOD SCHEDULE NET LOT SQ FOOTAGE 3806 SQ.FT. FRONT SQ FOOTAGE 1699 SQ.FT. BACK SQ FOOTAGE 2107 SQ.FT. Do JOB#: 08115 Y U O w Iry w En J CV CV Cal STIMATINC CREATED: AJ b/13/O8 PRE -CON: 6/20 REVISED: 6/24 ISSUED: PRINTED: 6/24 Q w r— SCALE: C-� SONOMA SUBDIVISION FOUNDATION NOTES AND DETAILS GENERAL NOTES I. THE CONTRACTOR IS RESPONSIBLE FOR VERIMNG ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH THE WORK. REPORT ANY DISCREPANCIES OR VARIATIONS FROM THE DRAWINGS TO THE ENGINEER FOR ANY REVISIONS THAT MAY BE REQUIRED. 2. REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR ELEVATIONS, SLOPES, DEPRESSED FLOOR AREAS, FINISHES, AND EMBEDDED ITEMS. FQUNDATION AND SUBGRADE SPECIFICATIONS 1. REMOVE SURFACE VEGETATION, ROOTS, AND ORGANIC MATERIALS TO A DEPTH OF 6'. THE EXPOSED SURFACE SHALL BE VISUALLY CHECKED AND ANY SOFT OR WEAK AREAS SHALL BE REMOVED AND PLACED BY COMPACTED FILL 2. COMMON FILLS SOILS SHALL CONSIST OF SOILS FROM THE SITE OR SOIL O SIMILAR CHARACTERISTICS OBTAINED FROM OTHER SITES. SELECT FILL SOIL (NATURAL SOURCE) SWJl BE FREE OF ORGANIC MATERIALS, A PLASTICITY INDEX OF LESS THAN 20. 3. FILL MATERIALS SHALL BE PLACED BY BOX BLADE OR FRONT END LOADER AND COMPACTED SUFFICIENT ENOUGH TO SUPPORT GRADE BEAM EXCAVATION AND CONCRETE PLACEMENT LOADS. 4. AFTER STRIPPING, BRING BUILDING PADS TO FINAL GRADE BY ADDITION OF SELECT FILL MATERIAL 5. PROVIDE 6 MIL THICKNESS WATERPROOFING BENEATH ALL BUILDING FOUNDATIONS AND SLABS. MATERIAL SHALL BE VIRGIN POLYETHYLENE PLASTIC FILM. OVERLAP 24' AT ALL JOINTS. REINFORCING STEEL SPECIFICATIONS 1. ALL REINFORCING STEEL SHALL BE NEW BILLET DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60. EXCEPT /3 BARS WHICH ARE BENT (SUCH AS STIRRUPS, TIES, OR DOWELS) MAY BE GRADE 40. WELDED WIRE FABRIC SHALL CONFROM TO ASTM A185. ALL REINFORCING SHALL BE CLEAN AND FREE OF MILL SCALE, 2. DETAILING AND FABRICATION OF REINFORCING BARS SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE, ACI 315. UNLESS SHOWN OTHERWSE, LAP CONTINUOUS BARS 30 BAR DIAMETERS AT SPUCES, 12 INCHES MINIMUM. 3. REINFORCING BARS MAY NOT BE WELDED WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER. 4. ALL TOP REINFORCEMENT SHALL HAVE CORNER BARS PLACED WITH THEM THAT EXTEND INTO ADJACENT BEAMS AND AT BOTTOM AS REQUIRED BY CODE. 5. PROVIDE NECESSARY TIES AND BAR SUPPORTS AS REQUIRED BY THE MANUAL O STANDARD PRACTICE, ACI 315. CHAIRS AND BOLSTERS FOR APPLICATION DIRECTLY OVER EARTH, POLY SHEETS, OR FELTS SHALL BE EQUIPPED WITH BOTTOM BEARING PLATES. 6. CONCRETE COVERAGE FOR THE REINFORCING STEEL SHALL COMPLY WITH THE 1998 ACI CODE. 7. WHERE THE GEOMETRIC CONFIGURATIONS O SUBS FORM INSIDE CORNERS, PROVIDE DIAGONAL REINFORCING ACROSS THESE CORNERS. EXCEPT WHERE SHOWN OTHERWISE, THIS REINFORCING SHALL BE 3-13 BARS X 5'-0' LONG 0 4. ON CENTER AT EACH SUCH CORNER, PLACED WITH TYPICAL SLAB REINFORCING. CAST IN PLACE CONCRETE SPECIFICATIONS I. ALL CONCRETE WORM( SHAH BE IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318. 2. ALL CONCRETE SHALL BE NORMAL WEIGHT (SAND AND GRAVEL AGGREGATE) WITH A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI. 3. NO HORIZONTAL JOINTS WILL BE PERMITTED IN CONCRETE WORK EXCEPT AS SHOWN ON THE DRAWINGS. ANY STOP IN CONCRETE PLACEMENT WILL BE MADE WITH VERTICAL BULKHEADS INCORPORATING A SHEAR KEY AT CENTERS OF SPANS. LOCATIONS FOR STOP POINTS SHALL BE APPORVED BY THE STRUCTURAL ENGINEER PRIOR TO THE PLACEMENT, 4. FORMWORK DESIGN IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL NOT BE REMOVED UNTIL THE CONCRETE HAS GAINED SUFFICIENT STRENGTH TO CARRY ITS OWN WEIGHT PLUS APPLIED CONSTRUCTION LOADS. 5. UNLESS OTHERWISE NOTED, CONCRETE COVER FOR REINFORCING STEEL SHALL BE: GRADE BEAMS - 3' BOTTOM; 2' SIDES AND TOP FLOOR SLABS - 2- 6. ALL PENETRATIONS AND SLEEVED HOLES SHALL BE APPROVED BY THE STRUCTURAL ENGINEER. 7. CONCRETE PLACEMENT SHALL BE ACCOMPLISHED BY DIRECT CHUTE FROM THE MIXER TRUCK OR BY PUMPING TO ITS FINAL POINT OF DEPOSIT. CONCRETE SHALL NOT BE DRUG BY HAND MORE THAN 5 FEET. 8. CONSOLIDATE CONCRETE BY PROPER USE OF MECHANICAL VIBRATOR. DESIGN CRITERIA REFERENCE GEOTECHNICAL ENGINEER'S REPORT PREPARED BY CME TESTING AND ENGINEERING, INC. TITLED *SONOMA SUBDIVISION - COLLEGE STATION, TEXAS' OCTOBER 2007 FOR SOIL CONDITIONS AND FOUNDATION DESIGN CRITERLA 'RE -BAR SPECS NOTE: ALL GRADE BEAMS QUICK COUNT BAR MIN. ES MIN, RADIUS MUST BE AT LEAST 6" INTO SIZE INCHES of BENDS UNDISTURBED NATURAL TOP BARS M32 fi i511aGROUND. BOTTOM BARS 151-9 16 BEAM WIDTH 20 2- a EXTERIOR BEAM DEPTH 2 3 INTERIOR BEAM DEPTH o a SLAB a I DN ✓/ /\ #3 BARS @ 14" 0C.al E.W. cl�/#3 STIRRUPS 0 36" O.C. z� 4 #5 BARS TOP & BOTTOM 6 MIL POLY W.P. SELECT FILL 4INTERIOR BEAM 1 INTERIOR SLAB DROP BRICK 8" x 112" ANCHOR BOLTS LEDG 5-1 2 2-1/2 ABOVE F.F. @ 48" O.C. `Ucv AND WITHIN Q OF DOOR o I i o #3 BARS 0 14" O.C.E.W. / �o L4#5 TIRRUPS @ 36" O.C. \\ o� 2� �o /\ BARS TOP &BOTTOM \ �N / d _ o 6 MIL POLY W.P. i\ \/ SELECT FILL 3EXTERIOR BEAM @ BRICK LEDGE 2EXTERIOR BEAM @ EXTERIOR WALL ,7. Ig-0 sue, - _o• BRICK LEDG 3 8" SMOOTH F REQUIRED 5- 2" 8" x 1 2" ANCHOR BOLTS D WEL WHERE 2-1/2�ABOVE F.F. @ 48" O.C.FLATWORK ABU S4" a ARIA$ AND 5" FROM DOOR OPENING v N Z �o a \\�/ #3 BARS @ 14" O.C.E.W. #3 BARS @ 12" O.C. /\ \ z� �o 4 #3 STIRRUPS @ 36" O.C. 4 #5 BARS TOP & BOTTOM \� 6 MIL POLY W.P. j \i V /%�✓ " SELECT FILL 6EXTERIOR BEAM @ GARAGE BRICK LEDGE SEXTERIOR BEAM GARAGE BRICK LEDGE a q -, -o 34'-1 I � I I I I I I14✓' I in I ^I b N I I I I � <71 ----------� --- --- --1 r J I I I I •IAA I I I I I I I I I I 6-- "I I b I I I n a 12 -6" I I I I I I I I I I I II 1„ I I I - --- - - - - - - - J L - - J I I I I v L- - - - - - -- v r------ ----------- r -- 2 ---------I '-8" F-------� I I I I I I I I I I I I I I I I I I I -I o- N I I I I I o I I I I I I I I I I I I I I I I I I I L- - - - - I I - - - - - J L - - - - - - - - I I I - - - - - - J L - - - - - - J F---- I I -------I I I I I -------1 F------� I I I I I I I I I I I I f I I I I I I I I I TIRE STOP ., I I I LI ------------T I a�• I I 1 n I I I "' I I I I L_J L ---T ---------J L------� I i I I I b' I I I I I I I I I I I 1 1 11 I in I I - ------4: I I _ - x I 10'- 16'- Frf of JOB#: 08115 Q U O L1J 0:� Lu () J V) CN CN CN STIMATINC CREATED: AI 6/ 1 3 PRF_f- ` �iGJ REVISED: 6/24 ISSUED: PRINTED: 6/24 z Q O 00 Q � M Z O � SCALE: 1 /8" - 1 '-0" S-1 BUILDING PERMIT CITY OF COLLEGE`STA-ION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00002031 Date 7/03/08 Application pin number . . . 350155 Property Address . . . . . . 2722 SILVER OAK DR Property ID: 578700-0202-0260 R #: R307359 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SONOMA PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY CLUSTER DEV Application valuation . . . . 95238 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 13.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 19.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID DUE FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT o GLAZING 12.00 GLAZING U-FACTOR .53 HEATED AREA 1443.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .35 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number 585232 Permit Fee 444.00 Plan Check Fee .00 Issue Date . . . . 7/03/08 Valuation . . . . 95238 Expiration Date 12/30/08 -------------------------------------------------------------- BUILDING DEPT REPRESENTATIVE: - APPLICANT: BUILDING PERMIT CITY OF COLLEGE -STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00002031 Date 7/03/08 Application pin number . . . 350155 Qty Unit Charge Per Extension BASE FEE 260.00 46.00 4.0000 THOU BLDG, VAL 50001-100000 184.00 ---------------------------------------------------------------------------- Special Notes and Comments *Engineered Bracing Methods Used To Meet Windbracing Requirements. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO ------------ BUILDING DEPT REPRESENTATIVE-------: ---------7✓' A �----------------------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE -STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00002031 Date 7/03/08 Application pin number . . . 350155 ---------------------------------------------------------------------------- Special Notes and Comments BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 15% the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 * THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED ----------- __ --_.---- '-------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGESTATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00002031 Date 7/03/08 Application pin number . . . 350155 ---------------------------------------------------------------------------- Special Notes and Comments PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 150W is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE ------------------------- --------------_-------------- BUILDING DEPT REPRESENTATIVE: !./ /% ,� • APPLICANT: BUILDING PERMIT CITY OF COLLEGE'STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00002031 Date 7/03/08 Application pin number . . . ---------------------------------------------------------------------------- 350155 Special Notes and Comments PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . IMPACT FEE AREA 97-01 98.39 SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited Due ----------------- Permit Fee Total 444.00 ------------------------------ 444.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 848.39 848.39 .00 .00 Grand Total 1292.39 1292.39 .00 .00 ✓ G �I.t BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE 'STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00002032 Date 7/03/08 Application pin number . . . 403792 Property Address . . . . . . 2722 SILVER OAK DR Property ID: 578700-0202-0260 R #: R307359 Application type description TEMP POLE Subdivision Name . . . . . . SONOMA PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY CLUSTER DEV Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 585240 Permit Fee . . . . 20.00 Issue Date . . . . 7/03/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ----------------- Paid Credited Due ---------- Permit Fee Total 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------------------��-'--------- BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT oATEY c Ec 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 APPLICATION # CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX TEMP POLE # .. Planning & De elapment Sen4ca WWW.CSTX.GOV ADDRESS/LOCATION: 7oU .5, I J2 r QcL K Ur, ✓ LOT VBLOCK "/ SUBDIVISION S O 110 M O� '/ SEC/PH Q � BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 127 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 127 CONTACT PERSON FOR REVIEW COMMENTS: JOSEPH SAUCIER PHONE: 690-1222 ext. 127 FAX: 690-0348 EMAIL: isaucier(cDstylecraft-builders.com ELECTRICIAN: _ Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY h ` DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION ` SLAB ONLY /`}/j �J DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL ,0 TENT/CANOPY DESCRIPTION OF WORK: Conventional Framing IV • PROPOSED USE: Single Family Residence WALL BRACING METHOD: PRESCRIPTIVED APA PORTAL FRAME W/ CSPS ENGINEERED HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ .� 39 TOTAL AREA: 195- It (Cost of Labor and Materials) " aW� FX PUBLIC SEWER NUMBER OF BEDROOM . 0 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: /0 QX SEWER TAP: 4" INTERIOR WALL TYPE: SIZE QX WATER TAP: %11 EXTERIOR WALL TYPE: Slding a dL' 4 SIZE OTHER TAP: FOUNDATION TYPE: Slab on Grade SIZE �Q X TEMP POLE ROOF TYPE: ��. ARAGE TYPE: SINGLE BLE a0,A.,�ATTACHED �X DETA D UU� SIGNATURE OF APPLICANT: �j *If proposed work involves new commercial constructiorelor fa commercial property, building elevations are required. ♦�������... *+*+*...... *.........oso Official Use lA,kW&,,, fdXnf�sExaminer _ f.11 l�.�aey�� Composition TRIPLE a CARPORT (_JZ5C5 For St lecraft cade im rovements/r novations to an existing ♦�s o�oeoss��eo�ssss���o Zoning Official Comments: Y-Por NO Fire Marshall -Energy Code Compliance Information % Glazing of exterior walls jc % / Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC (Solar Heat Gain Coefficient) .35 Glazing U-Factor .53 R value of ductwork R6 A/C SEER Rating 13 Protection Against Subterranean Termites a ❑ Chemical Termiticide Treatment (Soil Treatment) M ffChemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. 4k ' j 1 P 4.t•i13.,� �-�..St iA � ! y.... � �..�a jr.ri�! , a ; , _ "j ..,. PLAN REVIEW af/q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planningd'Development Srrvirti COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: BUILDING ADDRESS: I/ . K Ne, I. Foundation Requirements- Minimum City Foundation Standards N K A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated K II. Framing: Floor, Wall, Ceilingand Roof Requirements A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans NACM— F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. OK K PLAN REVIEW (*fl"" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning&DevdopmeneSeruica COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairwa Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N K 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location J CITY OF COLLEGE STATION' Planning cd Development Serviar PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room direct) off garage VII. Mechanical Requirements NA K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ K Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NAB Approved subdivision Plat filed Flood lain Re ulations — Ordinance 1301 N K Does not block any water course or divert any flow Elevation certificate needed A K "APPROVED PLANS PER IRC SECTION R106.3.1." J_1171�1_ tt� PL S EXAMINER DATE Permit # Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: Plan #1443 Report Date: 06/25/08 Data filename: S:\ACADWrchived\Old REScheck\1443 2722 Silver Oak.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: 2722 Silver Oak Dr. College Station, TX 77845 Permit Date: 6/25/08 Compliance: Passes Maximum UA`., 11._. Your, Home W 523r 7414 4% Getter Than_Code F Maximum SHGC: i-i i-i Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0' Air Conditioner 1: Electric Central Air: 13 SEER Furnace 2: Forced Hot Air: 80 AFUE 1345 30.0 0.0 47 103 19.0 0.0 5 1626 13.0 0.0 114 178 0.670 119 38 18 201 0.0 0.500 19 0.580 10 209 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. ThS.@1Qposed building has been designed to meet the 2003 IECC require ents in REScheck Version 3.7.3 and to comply with them dato r it fisted in the REScheck Inspection Checklis . to Builder/Designer Company Name Date Project Notes: Previously saved project information: Spec 2722 Silver Oak Dr. College Station, TX, 77845 Stylecraft Builders Inc. 4090 State Hwy. 6 South College Station, Texas 77845 Plan #1443 Page 1 of 1