HomeMy WebLinkAboutSLAB2008-02022`Yann+mc..
BUILDING PERMIT
CITY OF COLLEGE S!TATi'dN
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Tenant nbr, name . . . . . .
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
LTC REAL ESTATE HOLDINGS LLC
3000 BRIARCREST
STE 600
BRYAN TX 77802
08-00002022 Date 7/07/08
307322
14!60 COPPERFIELD PKWY
212200-0201-0010
R304221
SEIDEL & SCHROEDER
SLAB ONLY COMMERCIAL
CRESCENT POINTE PHASE 1
ADMIN. PROFESSIONAL
800000
Contractor
KEYS & WALSH CONSTRUCTION, LLC
232 SOUTHWEST PKWY E
COLLEGE STATION TX 77840
(979) 693-3200
--- Structure Information 000 000 SLAB ONLY PERMIT
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . BUSINESS
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 585356
Permit Fee . . . . 2260.00 Plan Check Fee .00
Issue Date . . . . 7/07/08 Valuation . . . . 800000
Expiration Date . . 1/03/09
Qty Unit Charge Per Extension
BASE FEE 1660.00
300.00 2.0000 THOU BLDG, VAL 500001 & UP 600.00
----------------------------------------------------------------------------
Special Notes and Comments
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*ELECTRICAL SHALL BE INSTALLED PER 2005 Nation Electrical
n Ak
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE : rTATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00002022
Application pin number . . . 307322
Page 2
Date 7/07/08
Special Notes and Comments
Code & LOCAL AMENDMENTS
*Per Section R106.3.3, 2006 IRC and section 106.3.3 2006
IBC, proceed with foundation work at own risk without
assurance that further permits will be issued.
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*INTERIOR BEAMS > 60' MUST BE A MINIMUM OF 30" DEEP
*THERE SHALL BE NO COMBUSTIBLE OR FLAMMABLE MATERIALS
PLACED ON SITE, LOT OR SUBDIVISION WHERE WATERLINES AND
FIRE HYDRANTS AS REQUIRED BY THE APPLICABLE SUBDIVISON
REGULATIONS ARE NOT COMPLETED AND IN SERVICE AND WHERE
ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES DOES NOT EXIST
TO WITHIN ONE HUNDRED FIFTY FEET (1501) OF THE MOST
REMOTE PART OF THE STRUCTURE. (IFC section 501.4)
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 2260.00 2260.00
Plan Check Total .00 .00
Grand Total 2260.00 2260.00
BUILDING DEPT R'EPZES
APPLICANT:
.00 .00
.00 .00
.00 .00
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
(*0r4"
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
I'lanuiag GF' 4reaAprmrRt$rrn1C4
WWW.CSTX.GOV
ADDRESS/LOCATION:
LOT � BLOCK
BUSINESS/OWNER NAME:
T�\MT-
�A or /fice XC
DATE:G
APPLICATION # V
TEMP POLE #
SUBDIVISION nzt$C. . F��� SEC/PH
If
CONTRACTOR/HOMEOWNER:S ye> uw'rk,5H ST_ PHONE:
CONTACT PERSON FOR REVIEW COMMENTS: Vesj .. WALSIA PHONE: ,7_0
FAX:
ELECTRICIAN: l out �C�N
HVAC: a:f+
ACCESSORY/STORAGE
ADDITION
DEMOLITION (ASBESTOS SURVEY)
DUPLEX (LANDSCAPE PLANS REQUIRED)
LOCATION
RETAINING WALL
DESCRIPTION OF WORK:
EMAIL:
i
PLUMBER: C;t{44
GOOD CENTS (Residential only):
MOVING
NEW CONSTRUCTION"
PORTABLE STORAGE (RESIDENTIAL)
PORTABLE STORAGE (NON-RESIDENTIAL)
REMODEIRENOVATION"
C3 V� �-s-
PROPOSED USE: �MrnlWVN e
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPR
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION NO. EABPRJ TLTIt/
z�z 6�• VALUATION: $ TV 1 TOTAL AREA: 'I U(6?,4� HEATED AREA:
(Cost of Labor and Materials)
❑ PUBLIC SEWER
SEPT]C/TREATMENT SYSTEM
SEWER TAP:
WATER TAP:
❑ OTHER TAP:
❑ TEMP POLE
GARAGE TYPE:
SIZE
SIZE
SIZE
SINGLE E]
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE
DETACHEl n
TRIPLE
CARPORT
0
RE -ROOF
SHELL ONLY
SLAB ONLY
SWIMMING POOL
TENT
El
Z
%/'fib/ ZftAiet-eL
1—
SIGNATURE OF APPLICANT: 11
If proposed work involves new c mercial construction or facade improvements/renovations to an existing
commercial property, building al6vations are required.
............................................................
Official Use Only
/,3-
Comments:
Plans Examiner Zoning Official