Loading...
HomeMy WebLinkAboutRES2008-01894, 08-1895a PREPARED 1/20/09, 12:02:53 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/20/09 ------------------------------------------------------------------------------------------------ ADDRESS . : 2920 HORSEBACK CT SUBDIV: HORSE HAVEN PH 3 CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504 OWNER OAKWOOD CUSTOM HOMES GROUP LTD PHONE PARCEL 336300-0302-0110 APPL NUMBER: 08-00001894 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/30/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00 7/30/08 AP July 30, 2008 9:27:13 AM glsouth. Strings up. Slab ground installed B115 01 9/12/08 RH BLDG, FRAMING TIME: 17:00 9/12/08 AE September 12, 2008 10:51:05 AM ccourt. Need temp. glass next to front door by building final. Tape seal all penetrations through moisture barrier by insulation. B130 01 9/16/08 BB BLDG, INSULATION TIME: 17:00 9/16/08 AP September 16, 2008 11:42:21 AM glsouth. B125 01 1/ 0/%99 I BLDG, FINAL TIME: 17:00 aQ/O °t Ire DC- January 20, 2009 9:30:16 AM kgreen. -------------------- ------------ COMMENTS AND NOTES 1 �' v Date: 1 /20/2009 Inspection Comments for Finals Permit Year: 8 Permit Number: 1894 Address: 2920 HORSEBACK CT Insp. Inspection Type Code p. status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings up. Slab ground installed 13115 BLDG, FRAMING IC Need temp. glass next to front door by building final. Tape 13115 BLDG, FRAMING IC seal all penetrations through moisture barrier by B115 BLDG, FRAMING IC insulation. P105 PLBG, TOP OUT IC Properly cap off drainline for back right showerr by P105 PLBG, TOP OUT IC framing. Page 1 08/04/2008 08:53 FAX 9796902504 CERTIFIED COPY IA003 AUG-04-2008 04:19 From:A-1 TERMITES To:6902504 Page 2/2 06-1 81 SUBTERRANEAN TERMITE PRECONSTRUCTION DISCLOSURE FOR EACH ESTIMATE For all treatments there will be a diagram slowing exactly what will be treated prior to the begun i ing of treatment. Review the pesticide label providers to you at this time for minimum treatment standai :ls, Remember that your architects or design engineers specifications must also be followed, unless they are in v elation of the law. Review the consumer information sheet tur Kather information. if you have any questions, r ontact the pest control company or the Texas Department of Agriculture, Structural Pest Control Service, P.O.:;ox 12847, Austin, Texas 78711-2847. Phone: (512) 305-8250. Contractor Name: Oakwood Custom Hoems Location Name: Property Owner Contractor Address: 4060 State Hwy 6 South Location to Treat: 2920 Horseback. 3rive College Station, TX 77845 College Station, IX 77845 Type of Treatment [ ] Full [X] Partial [ J Wood [ J Bait [ ] Commercial [X] Single 'annily A label of Maxxthor SC Termiticide(s) is enclosed. The percentage of the termiticide(s) to be applied at this location is: 0.06% Warranty Information provided must include the Complete Details of any Warr, inty provided and thefollowing; Time Period of Warranty; Renewal Options and Cost; and O'digations of the Contracting Parties. If the warranty does not include the entire stnncture treated, the areas included in the warranty al (specify) Total Square Feet to be Treated: 2341 Total Linear Feet to be Treated: Appmximate Measurements of the Structure(s) to be Treated: ...lJ G z, t.,f Russell C. Breland 07/: !)/2008 Signature of Certified Applicator or Printed Name Date Technician Completuig Estimate A-1 Termites TPCL 11932 _ Name ot'Pest Control Company TPCL. No. 11censed and regulated under the Texas Structural Pest Control Act Texas Npartnteat of Agriculture, Structural Pest Control Service, PO Box 12847, Austin, Texas 70711-2847, Phorl (512) 3054250. Page '1 of 4 WF1052706 / 001--- City of College Station 1 , P1`.GE 1 REQ. DATE: 06/30/08 06/30/08 14:34:16 LOCATION: 2920 HORSEBACK CT LOC ID: 208642 REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 06/30/08 SCHED COMPLETION: 06/30/08 ******************************************************************************** JOB ORDER RESULT COMMENTS BUILDING PERMIT CITY OF COLLEGE STATION — 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ------------------------------------------------------------------'--------- Application Number . . . . . 08-00001894 Date 6/24/08 Application pin number . . . 689034 Property Address . . . . . . 2920 HORSEBACK CT Property ID: 336300-0302-0110 R #: R305294 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . HORSE HAVEN PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 113804 Owner Contractor ------------------------ ------------------------ OAKWOOD CUSTOM HOMES GROUP LTD OAKWOOD CUSTOM HOMES 4060 SH 6 S 4060 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1504 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 13.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 19.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT 01 GLAZING 14.00 GLAZING U-FACTOR .54 HEATED AREA 1684.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .30 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 285.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 583278 Permit Fee . . . . 502.00 Plan Check Fee .00 Issue Date . . . . 6/24/08 Valuation . . . . 113804 Expiration Date 12/21/08 -----------------------------G%'d+',�-`---------- BUILDING DEPT REPRESENTATIVE: E'er APPLICANT: r BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00001894 Date 6/24/08 Application pin number . . . 689034 Qty Unit Charge Per Extension BASE FEE 460.00 14.00 3.0000 THOU BLDG, VAL 100001-500000 42.00 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with 24" Minimum OSB at Garage Returns. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO --------------------------------------------- ------ --- ---------- BUILDING DEPT�REPRESENtTAATIVE: APPLICANT: /G-✓�,Z�� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00001894 Date 6/24/08 Application pin number . . . 689034 ---------------------------------------------------------------------------- Special Notes and Comments BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 150-. the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 * THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI AN APPROVED --------------------------------------------- -- ---------- ------'--- BUILDING DEPT REPRESENTATIVE: Ai.dv1-0, APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00001894 Application pin number . . . 689034 Page 4 Date 6/24/08 Special Notes and Comments PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSI0 CONTROL SHALL BE - --------------- ----- ------------------------- ------ --- --'- ----------- BUILDING DEPT��REPRESENTATIVVV%E: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00001894 Date 6/24/08 Application pin number . . . 689034 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK *GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. *PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY BEING ELEVATED A MINIMUM OF 18" ABOVE FLOOR LEVEL. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total 502.00 502.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1252.00 1252.00 .00 .00 ----------------------------------------------`'I------- 61- - - -,a -- 10---------- BUILDING DEPT REPRESENTA' APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #- Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner ------------------------ OAKWOOD CUSTOM HOMES GROUP LTD 4060 SH 6 S COLLEGE STATION TX 77845 08-00001895 Date 6/24/08 839345 2920 HORSEBACK CT 336300-0302-0110 R305294 TEMP POLE HORSE HAVEN PH 3 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Contractor ------------------------ OWNER ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 583286 Permit Fee . . . . 20.00 Issue Date . . . . 6/24/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited Due ----------------- Permit Fee Total 20.00 ---------- 20.00 -------------------- .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - • - y- ------ BUILDING DEPOT RREEPRESEN'TAATTIVE�/f APPLICANT: -� APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 Crry OF COLLEGE SmvrtON (979) 764-3570 (979) 764-3496 FAX PLrnniug off' Drrtrinp+nrnt Srn.ira WWW CSTX GOV AOr c Ny DATE: V TR C REG -77 APPLICATION # TEMP POLE # ADDRESS/LOCATION:`` 2�20 1 ���Ci6000- �F•� LOT I BLOCK 2 SUBDIVISION HOB I AVN SEC/PH E ✓ BUSINESS/OWNER NAME: HOMES OMc� `A'' LTO'y O I CTAl?-nT&IV-(��� PHONE: 412- Z3L.-lJ �/-�K CONTRACTOR/HOMEOWNER: WOOD USPA V l�►1 W PHONE: lD ' o - 150 CONTACT PERSON FOR REVIEW COMMENTS: IZ ► W LUNDELL- PHONE: 21t/ D H 3 FAX: A - 25b4 ELECTRICIAN: [�C-R f�I7�C� HVAC: Sul EMAIL: ie1`Y �i/o��W►l� �ro PLUMBER: GOOD CENTS (Residential only): F ACCESSORY/STORAGE MOVING RE -ROOF ADDITION '\ NEW CONSTRUCTION" SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION \1 � I (��� �(J�� RrEMODDEL/ (RENOVATION` TENTS DESCRIPTION OF WORK: IV �IN hs L I�UII�T�' ff PROPOSED USE: SINfil r MIN K60ILATE- STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: ff-S TEXAS ACCESSIBILITY STANDARD (TA✓S) PROJECT REGISTRATION# EABPRJ VALUATION: $ I D TOTAL AREA: p�22A HEATED AREA: (Cost of L or and Materials) T79 PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM �c SEWER TAP: !'�' SIZE u WATER TAP: ZE OTHER TAP: 1ATEMP POLE GARAGE TYPE: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: SIZE ROOF TYPE: SINGLE F� DOUBLE 2L ATTACHED '5;t DETACHED a TRIPLE CARPORT 4 ICIT-204 WWI 3 Fl SIGNATURE OF APPLICANT: V WV Ly, *If proposed work involves new commercVal construction or facade improvements/renovations to an existing commercial property, building elevations are required. ............................................................ Official Use Only Gr1AA,.[, w(U Plans Examiner " Mvitay.t.o��al7'r�rr Zoning Official C ents: ES rN0 IA0_ Energy •Code Compliance Information % Glazing of, exterior walls` Insulation R value of exterior walls / Insulation R value of ceiling 1 (flat areas) 30 --/ Insulation R value of ceiling 2 (vaulted areas/no attic) 1 I -/ Glazing SHGC (Solar Heat Gain Coefficient) i 3c) '/ Glazing U-Factor t64 R value of ductwork &- (a ` ✓ A/C SEER Rating ?j Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. ' a NP. _. Af *..�+,.�jv!���+.',� :1,Ali%['�.G� t� E ti � `,•: f t'rl � �' � �, , `.�; �,Y{�' t � � 1 • .� PLAN REVIEW (*flq" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& DevelopmentServicet COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# O Q _ I $ DATE: 6-0-0 $ BUILDING ADDRESS: 1 n� 1 `�' 12fP�Ja lTf I. Foundation Requirements- Minimum City Foundation Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, rade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. S. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only All walls within 3' of property line to have protected openings. OK OK PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning 6, Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum of ten (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/ 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW (*t/4" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning &Dcvtiopmcnt&micet COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N OK A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N K A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NAIM Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N O Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed A K "APPROVED PLANS PER IRC SECTION R106.3.1." _JL_J_M_, '—PLANS EXAMINER i-Z3-a(6 DATE REScheck Software Version 4.0.1 Compliance Certificate Project Title: Camelot II Report Date: 06/11/08 Data filename: F:\projects\07-2919 Horseback Camelot 2\Camelot Il.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 14% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: 2920 Horseback Alton Ofczarzak Alton Ofczarzak College Station, TX 77845 Oakwood Custom Homebuilders, LLC Oakwood Custom Homebuilders, LLC 4060 State Highway 6 South 4060 State Highway 6 South College Station, TX 77845 College Station, TX 77845 979-690-1504 979-690-1504 seig @oakchb.com janalane@suddenlink.net . . Maximum SHGC: 0.40 Your SHGC: 0.30• , .. L,eurng i s mai cenmg or Scissor I russ: 1535 0.0 30.0 48 Ceiling 2: Cathedral Ceiling (no attic): 150 19.0 0.0 8 Wall 1: Wood Frame, 16" o.c.: 128 13.0 0.0 9 Window 1: Metal Frame:Double Pane with Low-E: 24 0.540 13 SHGC: 0.30 Wall 2: Wood Frame, 16" o.c.: 70 13.0 0.0 4 Window 2: Metal Frame:Double Pane with Low-E: 18 0.540 10 SHGC: 0.30 Wall 3: Wood Frame, 16" o.c.: 173 13.0 0.0 10 Window 3: Metal Frame:Double Pane with Low-E: 18 0.540 10 SHGC: 0.30 Window 4: Metal Frame:Double Pane with Low-E: 5 0.540 3 SHGC: 0.30 Window 4 copy 1: Metal Frame:Double Pane with Low-E: 5 0.540 3 • SHGC: 0.30 Window 6: Metal Frame:Double Pane with Low-E: 8 0.540 4 SHGC: 0.30 Door 1: Solid: 18 0.140 3 Wall 4: Wood Frame, 16" o.c.: 102 13.0 0.0 8 Wall 5: Wood Frame, 16" o.c.: 168 13.0 0.0 12 Door 2: Solid: 18 0.140 3 Wall 6: Wood Frame, 16" o.c.: 180 13.0 0.0 14 Window 7: Metal Frame:Double Pane with Low-E: 15 0.540 8 SHGC: 0.30 Wall 7: Wood Frame, 16" o.c.: 412 13.0 0.0 29 Window 8: Metal Frame:Double Pane with Low-E: 14 0.540 8 SHGC: 0.30 Window 9: Metal Frame:Double Pane with Low-E: 15 0.540 8 SHGC: 0.30 Window 9 copy 1: Metal Frame:Double Pane with Low-E: 15 0.540 8 SHGC: 0.30 Window 9 copy 2: Metal Frame:Double Pane with Low-E: 15 0.540 8 Camelot II Page 1 of 2 SHGC: 0.30 Window 12: Metal Frame:Double Pane with Low-E: SHGC: 0.30 Wall 8: Wood Frame, 16" o.c.: Window 13: Metal Frame:Double Pane with Low-E: SHGC: 0.30 Window 14: Metal Frame:Double Pane with Low-E: SHGC: 0.30 Wall 9: Wood Frame, 16" o.c.: Wall 10: Wood Frame, 16" o.c.: Door 3: Glass: SHGC: 0.30 Door 3 copy 1: Glass: SHGC: 0.30 Floor 1: Slab-On-Grade:Unheated: Insulation depth: 0.0' Furnace 1: Forced Hot Air: 78 AFUE Air Conditioner 1: Electric Central Air: 14 SEER 3 178 13.0 15 9 18 13.0 128 13.0 18 18 184 0.540 2 0.0 13 0.540 8 0.540 5 0.0 1 0.0 8 0.140 3 0.140 3 0.0 192 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Camelot 11 Page 2 of 2