Loading...
HomeMy WebLinkAboutRES2008-01892, 08-1893i i WF1052708 / 001 City of College Station r PAGE 1 REQ. DATE: 06/30/08 06/30/08 14:35:45 LOCATION: 2917 HORSEBACK CT LOC ID: 208650 REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 06/30/08 SCHED COMPLETION: 06/30/08 ******************************************************************************** JOB ORDER RESULT COMMENTS 08/04/2008 08 53 FAX 9796902504 CERTIFIED COPY AUG-04-2006 03:08 From:A-1 TERMITES To:6902504 R 001 Page ?--'ti 0 8 - l89,-1, SUBTERRANEAN TERMITE PRECONSTRUCTION DISCLOSURE FOR EACH ESTIMATE For all treatments there will be a diagram showing exactly what will be treated prior to the bcgir :dng of treatment, Review the pesticide label provided to you at this titne for minimum treatment standa ds. Remember that your architects or design engineers specifications must also be followed, unless they are in •c iolation of the law. Review the consumer information sheet for furtherinformation. If you have any questions, :ontact the pest control company or the Texas Department of Agriculture, Structural Pest Control Service, P.O. 13nx 12847, Austin, Texas 78711-2847. Phone: (512) 305-8250. Contractor Name: Oakwood Custom Homes Location Name; Property Owne1 Contractor Address: 4060 State Hwy 6 South Location to Treat: 2917 Horseback }Drive College Station, TX 77845 College Station„ '(X 77845 Type ()f'Treatment [ ] Full [X] Partial (] Wood [ ] Bait [ ] Commercial [X] Single Family A label of Maxxthor SC Termiticide(s) is enclosed. The percentage of the termiticide(s) to be applied at this location is: 0.06% Warranty Information provided must include the Complete Details of any Warf,znty provided and the following: Time Period of Warranty; ,Renewal Options and Cost; and 6 !,ligations of the Contracting Partie& If the warranty does not include the entire structure treated, the areas included in the wmTdnty a (specify) Total Square Feet to be Treated: 1853 Total Linear Feet to be Treated; Approximate Measurements of the Structurc(s) to be Treated: Russell C. Breland 07.1:'3/2008 Signature of Certified Applicator or Printed Name Date Technician Completing Estimate A-1 Termites TPCL 11932 Name of Pest Control Company TPCL. No. Licensed and regulated under the Texas Structural Pcrt Control Act Texas Department of Agriculture, Structural Pest Control Service, PO Box 12847, Austin, Textts 78711.2947, Phoi v: (512) MS.8250. Page t of 4 PREPARED 1/16/09, 7:54:31 INSPECTION TICKET PAGE 5 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/15/09 ------------------------------------------------------------------------------------------------ ADDRESS . : 2917 HORSEBACK CT SUBDIV: HORSE HAVEN PH 3 CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504 OWNER OAKWOOD CUSTOM HOMES GROUP LTD PHONE PARCEL 336300-0302-0080 APPL NUMBER: 08-00001892 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/23/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00 7/24/08 AP July 23, 2008 12:04:58 PM glsouth. Strings up. Slab ground installed B120 01 8/04/08 OC BLDG, FRAMING -PARTIAL TIME: 17:00 8/04/08 AP August 1, 2008 3:27:33 PM acarter. apa inspection B115 01 8/25/08 OC BLDG, FRAMING TIME: 17:00 8/29/08 AP August 26, 2008 10:18:54 AM ccourt. B130 01 8/29/08 OC BLDG, INSULATION TIME: 17:00 8/29/08 DP August 29, 2008 12:16:18 PM bboerboom. not finished B130 02 9/02/08 BB BLDG, INSULATION TIME: 17:00 9/02/08 AE September 2, 2008 9:36:28 AM bboerboom. Tape seal penetrations in moisture barrier, before bricking. B125 01 12/17/08 BB BLDG, FINAL TIME: 17:00 12/17/08 DP December 16, 2008 3:08:57 PM bcaldwell. Window at back door needs to be tempered. Secure Energy Requirements in panel. Need Vac. Breaker on hose bib. B125 02 1/15/09 BI BLDG, FINAL TIME: 17:00 )-16-Oq AP AR January 15, 2009 4:33:32 PM kgreen. -------------------------------------- COMMENTS AND NOTES -------------- ------------------------ N o a(zi 9M-i eN n T.ernP C . o, rvoea pa z �tj �Aa_a to A I t ow �C i/ZA�f'1 S 0� DR IOG�C2Q . �L W��I� q<� iv1Re- CQTLRS . BUILDING PERMIT CITY OF COLLEGE STATION -r 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 r PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00001892 Date 6/26/08 Application pin number . . . 388412 Property Address . . . . . . 2917 HORSEBACK CT Property ID: 336300-0302-0080 R #: R305291 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . HORSE HAVEN PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 98158 Owner Contractor ------------------------ OAKWOOD CUSTOM HOMES ------------------------ GROUP LTD OAKWOOD CUSTOM HOMES 4060 SH 6 S 4060 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1504 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 13.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 19.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT GLAZING 11.00 GLAZING U-FACTOR .54 HEATED AREA 1331.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .30 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 285.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 583989 Permit Fee . . . . 456.00 Plan Check Fee .00 Issue Date . . . . 6/26/08 Valuation . . . . 98158 Expiration Date . . 12/23/08 -------------------------------------------- ------ --- fir - BUILDING DEPT REPRESENTATIVE: APPLICANT: �}� '_ '/tA BUILDING PERMIT CITY OF COLLEGE STATION ' 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Page 2 Application Number . . . . . 08-00001892 Date 6/26/08 Application pin number . . . 388412 Qty Unit Charge Per Extension BASE FEE 260.00 49.00 4.0000 THOU BLDG, VAL 50001-100000 196.00 Special Notes and Comments -Add GFI to Master Bath Double sink area. -Narrow Wall Bracing Fully Sheathed with 24" Minimum OSB garage framing, if less then it must be APA Framed. Dining Area Windows to be modified, removing one to get 27" Minimum OSB per attached drawing. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED --- - - - - - - --------- BUILDING DEPT REPRESENTAT APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Page 3 Application Number . . . . . 08-00001892 Date 6/26/08 Application pin number . . . 388412 ---------------------------------------------------------------------------- Special Notes and Comments *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 15% the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 * THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to•U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ------------------------- ----- - ----��-------- ------------- - BUILDING DEPTTRRREEPRESENTTAATIVE: APPLICANT: � ._ ��/�/L BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00001892 Application pin number . . . 388412 Special Notes and Comments ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD Page 4 Date 6/26/08 *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS -----------------------------I---- BUILDING DEPT REPRESENTATIVE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00001892 Date 6/26/08 Application pin number . . . 388412 ---------------------------------------------------------------------------- Special Notes and Comments *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK *GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. *PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY BEING ELEVATED A MINIMUM OF 18" ABOVE FLOOR LEVEL. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 456.00 456.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1206.00 1206.00 .00 .00 ----------------------------- y ---------------------------- BUILDING DEPT REPRESENTATIVE: � ,/1 � • APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00001893 Date 6/26/08 Application pin number . . . 538723 Property Address . . . . . . 2917 HORSEBACK CT Property ID: 336300-0302-0080 R #: R305291 Application type description TEMP POLE Subdivision Name . . . . . . HORSE HAVEN PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ OAKWOOD CUSTOM HOMES GROUP LTD ------------------------ OAKWOOD CUSTOM HOMES 4060 SH 6 S 4060 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1504 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 583997 Permit Fee . . . . 20.00 Issue Date . . . . 6/26/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - -� APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION %* ff, 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 Crry Or COLLEGE STvriON (979) 764-3570 (979) 764-3496 FAX Awning oti' Avr1sp ome Srrvirer 1NWW/.'7CSTX.GOV(�1 ADDRESS/LOCATION` � (111 ROI�J LOT Y BLOCK 2— y SUBDIVISION HIDP L+ ELT-0tI D BUSINESS/OWNER NAME: /��I��I //���� �/� CONTRACTOR/HOMEOWWNER: W-WOOD CAGM ` HC) � —5 CONTACT PERSON FOR REVIEW COMMENTS: K 1 NN LU M DELL PHONE: Z - 0 1( 3 SEC/PH2.�1L PHONE: �� [(�} � Jf�O/ PHONE: �—I O r I�`T FAX: b `O - z5o EMAIL: �P� �I IIA �C� 00—ek b. ELECTRICIAN: �y ll!��^,1rV`f � e PLUMBER: kdi(LL \t`J D �% c HVAC: �� C( T GOOD CENTS (Residential only): 16 ACCESSORY/STORAGE MOVING RE -ROOF ADDITION `w NEW CONSTRUCTION` SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION �� R /E 'MODEL/RENOVATION` TENTS DESCRIPTION OF WORK: t� ME oommuGl� PROPOSED USE: S1IVOL, �1U 1 F—LJ1()ajw STRUCTURE USE: _G HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: y�✓ TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EJA�BPRJ 2 VALUATION: $ CIS. I5V 53 HEATED AREA: I ✓� (Cost and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM U SEWER TAP: 3 ZE WATER TAP: o SIZE OTHER TAP SIZE TEMP POLE GARAGE TYPE: SINGLE `� ATTACHED SIGNATURE OF APPLICANT: 'If proposed work involves new commercial onstruction or facade improvements/renovations to an existing commercial property, building elevations are required. ............................................................ Official Use Only /g G - 0_3 -4)f5 GAA� WA Plans Examiner — /►poi f4wAA 8Al2Q-�'eA NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE DETACHED 2 f/ 0 e.ICK- VUWU9-% SIDIW-1 COW- 6V1 w6L e TRIPLE .= CARPORT Zoning Official Comments: &Dor --Ad 6a +a 144.0 • fkg SIwkAuA - FVIl S Ld4JII e4e_Aa zq"Mf,. Os8dm (7*A vye 1 14 "4 'Energy Code Compliance Information % Glazing of exterior walls *' y Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating 13 Pe - Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other t * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. F.•J1ai',t a.r\��. �'."��h 1: 'c';, `mot �w .. h..�Yt-� r1+¢i'�. �. C'l�1 (A JIV w N N, A V'S ' r l r1, . ' .•., t;T-%');�: „3�-,a.�Ti,•L i 'j" ,a-5.5;�v .V.�._^ �:.1 G I �l�tl�97 MN r• . ` t PLAN REVIEW (*f/ ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# O _ SCUZ DATE: BUILDING ADDRESS: S id a G (51-. I. Foundation Requirements- Minimum City oundation Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated O II. Framing: Floor, Wall, Ceiling and Roof Requirements WAIQV A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. K OK i PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning 6 Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1 /2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location .r CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N K Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." w PLANS EXAMINER DATE REScheck Software Version 4.0.1 Compliance Certificate Report Date: 06/17/08 Data filename: F:\projects\2804-horseback\2804RESCHK.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 11 % Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: 2917 Horseback ALTON OFCZARZAK David Park College Sataion, TX 77845 OAKWOOD CUSTOM HOMES GROUP OAKWOOD CUSTOM HOMES GROUP LTD. LTD. HOME PLAN DESIGN SERVICE 4060 HWY. 6 SOUTH 4060 Highway 6 South COLLEGE STATION, TX 77845 College Station, TX 77845 979-690-1504 979-690-1504 PLANS@OAKCHB.COM plans@oakchb.com Compliance:,°Passes <=-` _ •• . ' ,, ` Maximum UA: 600 � Your Home°UA' 474 -'-> 22.2% Better Than Code UA Maximum SHGC: 0.40 Your SHGC: 0.30 uuning r. riaL temng or scissor i russ: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: 2030: Metal Frame:Double Pane with Low-E: SHGC: 0.30 2650x2: Metal Frame:Double Pane with Low-E: SHGC: 0.30 3008hs: Metal Frame:Double Pane with Low-E: SHGC: 0.30 3030: Metal Frame:Double Pane with Low-E: SHGC: 0.30 3050 XT Metal Frame:Double Pane with Low-E: SHGC: 0.30 306Ox2: Metal Frame:Double Pane with Low-E: SHGC: 0.30 3068 FRONT DOOR: Solid: 2868 BACK DOOR: Solid: 2868 TO GARAGE: Solid: CONC. SLAB: Slab-On-Grade:Unheated: Insulation depth: 0.0' Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER Air Conditioner 1: Electric Central Air: 14 SEER 1285 0.0 30.0 40 22 19.0 0.0 1 1622 13.0 0.0 113 6 0.540 3 25 0.540 14 1 0.540 1 9 0.540 5 105 0.540 57 36 0.540 19 20 0.140 3 18 0.140 3 18 0.140 3 203 0.0 212 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Project Notes: HORSE CLASSIC Signature Date Page 1 of 1