HomeMy WebLinkAboutADDN2008-01855PREPARED 9/09/08, 7:58:01 INSPECTION TICKET PAGE 6 City of+College Station INSPECTOR: BUILDING INSPECTOR DATE 9/08/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 704 PUTTER CT SUBDIV: PEBBLE CREEK CONTRACTOR HUSFELD HOMES PHONE (979) 696-4369 OWNER CRAIGEN, TAYLOR & CINDY L PHONE PARCEL 497900-0025-0210 APPL NUMBER: 08-00001855 RESIDENTIAL, ADDITION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/08/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00 7/08/08 AP July 7, 2008 4:15:05 PM acarter. strings on setbacks. B115 01 7/24/08 OC BLDG, FRAMING TIME: 17:00 7/25/08 AP July 24, 2008 8:05:30 AM acarter. B130 01 7/25/08 OC BLDG, INSULATION TIME: 17:00 7/25/08 AP July 25, 2008 12:18:21 PM glsouth. July 25, 2008 12:18:26 PM glsouth. B125 01, 9/08/08 BLDG, FINAL TIME: 17:00 _ �oQlot September 8, 2008 4:26:17 PM glsouth. ( w ---------------------------------- CONTINUED ONTO NEXT PAGE----------------------------------- eC I WF1077424 / 001 City of Colleges Station 515 PAGE 1 REQ. DATE: 08/06/08 08/06/08 16:56:02 LOCATION: 704 PUTTER CT LOC ID: 132480 REQUESTOR: HUSFELD HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: SWR 4 " ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 08/06/08 SCHED COMPLETION: 08/06/08 JOB ORDER RESULT COMMENTS BUILDING PERMIT c �i CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00001855 Date 6/18/08 Application pin number . . . 805905 Property Address . . . . . . 704 PUTTER CT Property ID: 497900-0025-0210 R #: R97896 Application type description RESIDENTIAL, ADDITION Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 30000 Owner Contractor ------------------------ CRAIGEN, TAYLOR & CINDY ------------------------ L HUSFELD HOMES 704 PUTTER CT 3204 LONGMIRE DR COLLEGE STATION TX 778458997 COLLEGE STATION TX 77845 (979) 696-4369 --- Structure Information 000 000 ADDITION Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 13.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 19.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA GLAZING 10.00 GLAZING U-FACTOR .65 HEATED AREA 650.00 INTERIOR WALL TYPE SHEETROCK EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .40 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number 581892 Permit Fee 160.00 Plan Check Fee .00 Issue Date . . . . 6/18/08 Valuation . . . . 30000 Expiration Date . . 12/15/08 Qty Unit Charge Per 29.00 BASE FEE 5.0000 THOU BLDG, VAL 1001-50 -------------------------------------------------- BUILDING DEPT REPRESEDI-TATIVE : ,i APPLICANT: Extension 15.00 145.00 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00001855 Application pin number . . . 805905 Page 2 Date 6/18/08 Special Notes and Comments -Narrow Wall Bracing to be Fully Sheathed *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 15% the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE ----------------------------------------------�E - ------ -- Al�� ------- BUILDING DEPT REPR NTATIVE: X. APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00001855 Application pin number . . . 805905 Page 3 Date 6/18/08 Special Notes and Comments UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO QOVERING ANY WORK - APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00001855 Date 6/18/08 Application pin number . . . ---------------------------------------------------------------------------- 805905 Other Fees . . . . . . . . . SEWER TAP 4" 350.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited ---------- Due ---------- ----------------- Permit Fee Total 160.00 160.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 350.00 350.00 .00 .00 Grand Total 510.00 510.00 .00 .00 ------------------- BUILDING DE APPLICANT: CITY OF COLLEGE STATION Planning & Dewtopment Semices ADDRESS/LOCATION APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV 7 0 y A:4A1 � -V , LOT Z ( BLOCK r- SUBDIVISION PQ�Pc o/4 SEC/PH BUSINES OWNER ME: %/JM Jd✓ /rrwit e^ PHONE: G / o _Zr►-yq, -7 NTRACT R/HOMEOWNER: wy t v PHONE: wa — s<36? CONTACT PERSON FOR REVIEW COMMENTS: PHONE: Z ll FAX: 7 ry of ?I'/% ELECTRICIAN: C 14/ PLUMBER: _�r. l7 HVAC: S/CC" GOOD CENTS (Residential only): CESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY DUPLEX (Landscape Plans) RE MODE URENOVATION* SWIMMING POOL ff TENT/CANOPY DESCRIPTION OF WORK: Adg —am v4p fjyrio PROPOSED USE: '969 HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ \�D VALUATION: $ ? 0t m D TOTAL AREA: HEATED AREA: .SRO (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: jP �WER TAP: INTERIOR WALL TYPE: f/ WATER TAP: E EXTERIOR WALL TYPE:'<<c OTHER TAP: TEMP POLE GARAGE TYPE Z'n ( - SIZE SIZE SINGLE ATTACHED FOUNDATION TYPE ROOF TYPE: DOUBLE El 'ETACHED n TRIPLE El SIGNATURE OF APPLICANT: 'If proposed work involves new comme clal construction or fac mprovements/renovations to an existing commercial property, building elevations are required. Official Use Only Plans Examiner Zoning Official Fire Marshall C ments: t-90 N O Energy Code Compliance Information % Glazing of exterior walls n `� Insulation R value of exterior walls / Insulation R value of ceiling 1 (flat areas) 3 0 Insulation R value of ceiling 2 (vaulted areas/no attic)/¢ Glazing SHGC (Solar Heat Gain Coefficient) • q0 Glazing U-Factor s R value of ductwork A/C SEER Rating y Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy.