Loading...
HomeMy WebLinkAboutRES2008-01828, 08-1829N PREPARED 5/04/09, 7:52:16 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/01/09 ------------------------------------------------------------------------------------------------ ADDRESS . : 2117 BLACKJACK DR SUBDIV: CARTER'S CROSSING PH 3 CONTRACTOR BRIAN GERMAN CUSTOM HOMES INC PHONE (979) 220-8964 OWNER CARTER'S CROSSING JOINT PHONE PARCEL 183200-0312-0030 APPL NUMBER: 08-00001828 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/25/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00 6/25/08 AP June 25, 2008 10:12:27 AM acarter. B115 01 8/05/08 DS BLDG, FRAMING TIME: 17:00 8/05/08 AP August 5, 2008 8:29:49 AM acarter. B130 01 8/07/08 RH BLDG, INSULATION TIME: 17:00 8/07/08 AP August 7, 2008 8:47:19 AM ccourt. B125 01 3/30/09 BB BLDG, FINAL TIME: 17:00 3/30/09 DA March 27, 2009 4:48:33 PM kgreen. House is locked B125 02 5/01/09 BI BLDG, FINAL TIME: 17:00 May 1, 2009 3:53:32 PM ccourt. -------------------------------------- COMMENTS AND NOTES------- ------------------------------- �i�I�'1- Date: 4/9/2009 Inspection Comments for Finals Permit Year: 8 Permit Number: 3074 Address: 8409 JUSTIN AVE Type Inspection Type Code Description Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC strings up slabground down B130 BLDG, INSULATION IC Tape seal all pentrations in Grip Rite, befor bricking! E150 ELEC, FINAL IC Need proper access to test gfi plug at whirlpool tub and for E150 ELEC, FINAL IC servicing motor.Need to secure and protect wires passing E150 ELEC, FINAL IC through furnace cabinet.Need plug within 2ft of end of E150 ELEC, FINAL IC kitchen counter wall. Need plug at end of penisula. The one E150 ELEC, FINAL IC under counter is not allowed with more than 6" of countertop E150 ELEC, FINAL IC overhang. P125 PLBG, FINAL I IC JAII electric. Page 1 WF104744o / Doi City of College Station IPAGE 1 REQ. DATE: 06/17/08 06/17"/08=13:39:45 LOCATION: 2117 BLACKJACK DR LOC ID: 211190 REQUESTOR: BRIAN GERMAN CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" yr TASK: SET UP NEW UTILITY ACCT SET READY X ; SCHED START: 06/17/08 SCHED COMPLETION: 06/1.7/08 ******************************************************************************** JOB ORDER RESULT COMIENTS Nov 10 08 01:49p MACIAS 9797744736 p.4 TEXAS SPCS TERMITE TREATMENT DISCLOSURE DOCUMENT BRIAN GERMAN CUSTOM HOMES 2117 BLACKJACK — - — 111 - - — �UrZORTTTZMM 77-17. 3207 08, rB w t Pe 1 r. • -of be applied at thisoc • 1 I 1 . 107 GAL Type gurea32"1Partial r � � r •1• •1Sidings Primary!jsee RESIDENCE RQQf* -COMPOSITION 1 :• • - • { e 1 it l"� e. • . •• l !1l A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS 000UMENT_ WARRANTY INFORMATION (IF ANY) INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE- TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. Charges for pre -treat: NOTES: Annual re-newal: SEE ATTACHED SKETCH BUILDERS SUPPLIES SKETCH/ PLAN $451.22 $130.00 32'129 PT Ca or Tecmnclm SPCS Iicarae 0 6124/2008 32120 PT t BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #: Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner CARTER'S CROSSING JOINT VENTURE 311 CECILLA LOOP COLLEGE STATION TX 77845 08-00001828 Date 6/17/08 887112 2117 BLACKJACK DR 183200-0312-0030 R306850 RESIDENTIAL, 1 UNIT DETACHED NEW CARPER' S CROSSING PH 3 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 211662 Contractor BRIAN GERMAN CUSTOM HOMES INC 1505 CR 307 CALDWELL TX 77836 (979) 220-8964 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 14.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 19.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT o GLAZING 15.00 GLAZING U-FACTOR .54 HEATED AREA 2459.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .33 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- TRAFFIC IMPACT ANAL (TAZ) 244.00 Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 581652 Permit Fee . . . . 796.00 Plan Check Fee .00 Issue Date . . . . 6/17/08 Va ation . . . . 211662 ----------------------- -- ------ ----- ------ ----- --- - --------- BUILDING DEPT ENTAT VE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Page 2 Application Number . . . . . 08-00001828 Date 6/17/08 Application pin number . . . 887112 Expiration Date . . 12/14/08 Qty Unit Charge Per Extension BASE FEE 460.00 112.00 3.0000 THOU BLDG, VAL 100001-500000 336.00 Special Notes and Comments -Make sure of proper Kitchen COuntertop GFI's placement -Narrow Wall Bracing Fully Sheathed with 18" Minimum Garage APA Framing *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ----------------------- -- ----- ------------- ------ ---- ----- ------- BUILDING DEP RE ESENTA IV APPLICAN i .�- BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00001828 Application pin number . . . 887112 Page 3 Date 6/17/08 Special Notes and Comments *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 150-. the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 * THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foa other means. Also assure proper protection of pi e U.V ig . ------------------------------------- - -- ---- ------------------------ BUILDING DEPT REPRESENTATIVE: %f - ,# . APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00001828 Application pin number . . . 887112 Page 4 Date 6/17/08 Special Notes and Comments *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. BUILDING DEPT iiFi E ENTA yi� - �_ -- --------- J_ _A;~4(_t; -------- APPLICANT: BUILDING PERMIT ' CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00001828 Date 6/17/08 Application pin number . . . 887112 ---------------------------------------------------------------------------- Special Notes and Comments *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 796.00 796.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1546.00 1546.00 .00 .00 BUILDING D APPLICANT: TEMPORARY POLE PERMIT ` CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner CARTER'S CROSSING JOINT VENTURE 311 CECILLA LOOP COLLEGE STATION TX 77845 08-00001829 Date 6/17/08 967466 2117 BLACKJACK DR 183200-0312-0030 R306850 TEMP POLE CARTER'S CROSSING PH 3 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Contractor BRIAN GERMAN CUSTOM HOMES INC 1505 CR 307 CALDWELL TX 77836 (979) 220-8964 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc AC Permit pin number 581660 Permit Fee . . . . 20.00 Issue Date . . . . 6/17/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total 20.00 20.00 .00 - .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------- --------- ------------- ----- --- - -- ------- BUILDING DEPT SENTATI E- APPLICANT: o� _9Y Mimics 9- Ai'NLIGAI IUN 1-UK tSUILIJINU t-tKMI I —1— 1101 TEXAS AVENUE APPLICATION # ��` COLLEGE STATION, TX 77840 CM OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX TEMP POLE # 09 V P14mmnd dDewkvmmt $erviut W W W.CSTX.GOV ADDRESS/LOCATION: 'oZI ) 7 (3LA_K51f�K LOT BLOCK rSUBDIVISION a19!-_51 "-�1 61 `/ SEC/PH BUSINESS/OWNER NAME: 'BbftS, _95k4 CONTRACTOR/HOMEOWNER: PHONE: CONTACT PERSON FOR REVIEW COMMENTS:PHONE:1'` FAX: �I'lal -ir>q d-(c(o22 ELECTRICIAN ►=�►1 4�►J[ E_G - HVAC: 1e/ EMAIL: bP� `�G L r✓1Lvr� �4r� ®�-� cry rLl PLUMBER: QLr-�C3�C� GOOD CENTS (Residential only): Kr'zN ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION ' MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:c%S TEXAS ACCESSIBILITY STANDARD (rAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ vZl I , lv� Z ✓ TOTAL AREA: HEATED AREA: (Cost ofLabor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 11 �S€WER TAP: si:z> INTERIOR WALL TYPE: & �.P,eA.%09 SIZE - yL WATER TAP: Sit,� I � EXTERIOR WALL TYPE: �Q � �.IL SIZE OTHER TAP: FOUNDATION TYPE: SIZE TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE a DED OUB TRIPLE a ATTACHED E Q CA RT SIGNATURE OF APPLICANT: a *If proposed work involves new commercia construction de improvements/renovations to an existing commercial property, building elevations are required. Official Use,On/y _7'A E)zf Plans Examiner Zoning Official _ Fire Marshall — locA}iop Am i Iw &- BAtk'iiIiIL 3- 4cv zyf 4,ce4 S ut GF� ments: W/ rf tt 9) Ai wwv.,.. AAA- GAAW qj�" . Vt 0 Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling I (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork ✓ A/C SEER Rating Protection Against Subterranean Termites 2Chemical Termiticide Treatment (Soil Treatment) El Chemical Ternliticide Treatment (Field Applied Wood Treatment), El Physical Barriers rl Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of 0cpup cy,. CURVE TABLE CLRNE LENGTH RADIUS I DELTA I TANSA NT I 04ORD I CHORD BEARIt r. C12 ows, 125m®' 54'25'S9" 1 6429' 1 11434' 1 N 14.3815" W I M-%C ,2117 BLACKJACK DRIVE _ OF ��. 61�i2%8 CARTER'S CROSSIWG &JWI)ASI ,?N PHA$E THREE BLOCK 12 LOT 3 2111 BLACKJACK DRIVE S\`J'ls,I r-- CITY O CAX.LEGE STATION, TEXAS SCALE: I.20 RERECOI® DOF"r OF TNti DRNLMG M ON ftE AT TEE o. TODD MON.N — ,egVHIrECiiFE a+q L GE ST T10K C G SLE TWAT10N, O T 91 TN8 ELECTRONIC DOupw Is RELEASED FOR THE MR09 OF REFEIVE"CE. CCDI®P1A,TIOKN, AND OR PA AUTW Pt N OP i 00 1lIDEIY TEE AIITIl A OF TODD ORAV 0 G.ALL) TO M1IM DRAYRCa &TALL GE M COMRIANGE WITN THE TPa BOARD OF EXAMWEIls' IB1LE8. MAW BT: cm CHECKED BT CTH DATE: •!@APE IEEJED FOR PER T: IS&A. FOR PRICkl6� iEsiEo FaR COrInrRUCnoN: lu REN9Kx9 U $ U 4 U Q� O }o z x �O z f- QU 4 too r� O �jj In PLOT PLAN ma -mot REScheck Software Version 4.0.1 Compliance Certificate Project Title: 2117 Blackjack Drive- Spec 8 Report Date: 06/13/08 Data filename: C:\Documents and Settings\Administrator\Desktop\REScheck\2117 Blackjack.rck Energy Code: Location: Construction Type: Glazing Area Percentage: Heating Degree Days: Construction Site: 2117 Blackjack Drive College Station, TX 77840 20001ECC College Station, Texas Single Family 15% 1788 Owner/Agent: Bria German Custom Homes, Inc. 2117 Blackjack Drive College Station, TX 77840 979-220-8964 briancgerman@yahoo.com Designer/Contractor: Brian German Custom Homes, Inc. 2117 Blackjack Drive College Station, Texas , TX 77840 979-220-8964 brianogerman@yahoo.com Compliance: Passes Maximum UA: 521 Your Home UA: 386 --> 25.9% Better Than Code (UA) Maximum SHGC: .i Your SHGC: 0.33 Ceiling 1: Flat Ceiling or Scissor Truss: 2459 o.0 ;su.0 to Wall 1: Wood Frame, 16' o.c.: 2072 13.0 0.0 145 Window 1: Metal Frame:Double Pane with Low-E: 249 0.540 134 SHGC: 0.33 Door 1: Glass: 58 0.540 31 SHGC: 0.33 Compliance Statement: The proposed building design described here is consistent with the building plans, specfications, and other calculations submitted with the permit application. The proposed building has been signed eet the 2000 IECC requirements in REScheck Version 4.0.1 and to comply with a mandatory r ents listed in a RESche Inspection Checklist. Name - �Title Signature Date 2117 Blackjack Drive- Spec 8 Page 1 of 1 f CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 6 _ I 8;.s DATE: BUILDING ADDRESS: _ All -7 FlAck ec�J bg. I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated K II. Framin : Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans A/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. S. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only All walls within 3' of property line to have protected openings. "/OK OK U ` 1 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& DevelopmentStrvica COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairwa Details N90K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N / 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NAI K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements hl Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NA/ K Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed VOK "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER DATE