HomeMy WebLinkAboutRES2008-01805, 08-1806NOW PREPARED 10/23/08, 8:05:39 INSPECTION TICKET PAGE 4 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/22/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 300 HOLIK ST SUBDIV: HOLICK (CS) CONTRACTOR VENABLE HOMES PHONE (979) 224-3036 OWNER WILDING, CHARLES PHONE PARCEL 332100-0004-0070 APPL NUMBER: 08-00001805 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/08/08 DS BLDG, FOUNDATION -SLAB TIME: 17:00 7/08/08 AP July 8, 2008 9:10:24 AM acarter. slab installed strings on setbacks O/K B115 01 8/12/08 DS BLDG, FRAMING TIME: 17:00 8/13/08 AP August 12, 2008 1:47:42 PM bboerboom. Hold until electrical reinspect. B130 01 8/12/08 DS BLDG, INSULATION TIME: 17:00 8/14/08 AP August 13, 2008 11:16:38 AM ccourt. Thursday afternoon please B125 01 10/21/08 DS BLDG, FINAL TIME: 17:00 10/21/08 DP October 21, 2008 10:53:45 AM glsouth. needs to insulate attic ' can not locate attic light smoke decteor to close to ceiling fan B125 02 10/22/08 By BLDG, FINAL TIME: 17:00 ctober 22, 2008 1:24:50 PM ccourt. / ---------------------------- ------ COMMENTS AND NOTES -------------------------------------- Date: 10/21 /2008 Inspection Comments for Finah Permit Year: 8 'ermit Number: 1801 Address: 300 HOLIK ST Type inspection Type Code Insp Status Inspection Result Comments Description B100 BLDG, FOUNDATION-SL, IC slab installed B100 BLDG, FOUNDATION-SU IC strings on setbacks O/K B115 BLDG, FRAMING IC Hold until electrical reinspect. Ell ELEC, ROUGH IN IC SD 's to close to fans in popup ceilings E150 ELEC, FINAL IC needs to have switches for bathroom on arc fault M100 MECH, ROUGH IN IC left note for electric to check on locations of SD's P125 PLBG, FINAL IC all electric Page 1 REScheck Software Version 4.0.1 Compliance Certificate Project Title: Plan #1806-1854 Report Date: 06/02/08 Data filename: \\Mybookwodd\public\Job Files\08-047 WILDING\plan #1806-1854.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 1788 Construction Site: 300 Holik Drive College Station, TX Owner/Agent: C.W. Investments TX 979 575-8889 Designer/Contractor: John Rhodes R.A.I. Designs, Inc. TX 979-846-3366 Compliance: Passes .-=r;-Maximum UA: 616 Your Home UA 500 —> 18.0% Better Than Code (UA) Maximum SHGC: 0.40 i 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Flat Ceiling or Scissor Truss: Ceiling 3: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Wall 2: Wood Frame, 16" o.c.: Floor 1: Slab -On -Grade: Unheated: Insulation depth: 0.0' Furnace 1: Forced Hot Air: 81 AFUE Air Conditioner 1: Electric Central Air. 13 SEER 221 30.0 .0.0 8 695 30.0 0.0 24 253 19.0 0.0 13 1254 13.0 0.0 80 236 0.650 153 38 0.500 19 700 13.0 0.0 57 140 0.0 146 Compliance Statement., The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requirements ' ted 'n the R Scheck Inspection Checklist. J o h n ►hod �S 6 -2o,? Name - Title Si a ure IF Date Plan #1806-1854 Page 1 of 1 P Area Calculator: Add to Library Window Name T Assembly ype Quantit y Width x Height Unit = Area Total Area U-Facto r SHGC Comments/ Description 1 3050 Metal Frame, Do 1 3'-0" 5'-0" 15.00 15.00 ft2 0.650 0.400 2 2026 Metal Frame, Do 1 2'-0" 2'-6" 5.00 5.00 ft2 0.650 0.400 3 2850 Twin Metal Frame, Do 1 5'-4" 5'-0" 26.67 26.67 ft2 0.650 0.400 4 3050 Metal Frame, Do 1 3'-0" 5'-0" 15.00 15.00 ft2 0.650 0.400 5 1 14010 Metal Frame, Do 1 4'-0" 1'-0" 4.00 4.00 ft2 0.650 0.400 6 4010 Metal Frame, Do 1 4'-0" 1'-0" 4.00 4.00 ft2 0.650 0.400 7 3050 Metal Frame, Do 1 3'-0" 5'-0" 15.00 15.00 ft2 0.650 0.400 8 3050 Metal Frame, Do 1 3'-0" 5'-0" 15.00 15.00 ft2 0.650 0.400 9 4060 Metal Frame, Do 1 4'-0" 6'-0" 24.00 24.00 ft2 0.650 0.400 10 3050 Metal Frame, Do 1 3'-0" 5'-0" 15.00 15.00 ft2 0.650 0.400 11 3050 Metal Frame, Do 1 3'-0" 5'-0" 15.00 15.00 ft2 0.650 10.400 12 2040 Fixed Metal Frame, Do 1 2'-0" 4'-0" 8.00 8.00 ft2 0.650 0.400 13 2040 Fixed Metal Frame, Do 1 2'-0" 4'-0" 8.00 8.00 ft2 0.650 0.400 14 1440 Fixed Metal Frame, Do 1 1'-4" 4'-0" 5.33 5.33 ft2 0.650 0.400 15 2850 Arch Metal Frame, Do 1 2'-8" 5'-0" 13.33 13.33 ft2 0.650 0.400 16 1440 Fixed Metal Frame, Do 1 1'-4" 4'-0" 5.33 5.33 ft2 0.650 0.400 17 2040 Metal Frame, Do 1 2'-0" 4'-0" 8.00 8.00 ft2 0.650 0.400 18 5030 Slider Metal Frame, Do 1 5'-0" 3'-0" 15.00 15.00 ft2 0.650 0.400 19 5030 Slider Metal Frame, Do 1 5'-0" 3'-0" 15.00 15.00 ft2 0.650 0.400 20 4010 Metal Frame, Do 1 4'-0" 1'-0" 4.00 4.00 ft2 0.650 0.400 21 22 23 24 25 Window Area Total: 235.66 06/02/08 13:10:26 1 /1 Area Calculator: Assembly Type COMM Description Door Area Total: 37.78 06/02/08 13:10:26 1 /1 r' Area Calculator: M Assembly Type Comments/Description v m■�■�� m■�■�� m■�■�� m■�■�� m■�■�� Ceiling Area Total: 1169.00 06/02/08 13:10:27 1 /1 Area Calculator: 0 Assembly Type ... . . cffa�=Comments/Description ■ MORM21 " i p MIN M.- 06/02/08 13:10:27 Exterior Wall Area Total: 1954.00 1/1 Area Calculator: ■Assembly Type' ©�■ Comments/Description 06/02/0813:10:27 Floor Area Total: 0.00 1/1 . . P1.11 1 0A V tj I � J �I�7 �. _ �I11►� •� I a J�lIIII�' * r r-- I 0:- O O m fl Ili E Y� 7-11 l I [ I � Y�4 I I 1 rM E i cl SHEET BBJ-REVISIONS 05- C.W. INVESTMENTS JTR -REVISIONS OS 27.08 OF: BBJ-REVISIONS 05-2M JOB# 08-047 six DATE: PLAN# 1806-1854 �• DESIGNS, INC. I I I I I I I I I I i I (r)�I�rreirnn 'lwlsnr�.,i.r. (979)-846-3366 4500 CARTER CREEK SUITE 203 j BRYAN, TX 77802 www.raidesims.com i 1 d vy- ,.HIGH TECH SUBTERRANEAN TERMITE TREATMENT EST]MATE J 2 IF-L_Le Gce-;_ This estimate includes all labor, equgp Mint and materials necsatreat t he or portions (spot treatment) of a structure for the control.of subterranean termites. described eThe treatment i guaranteed for 12'months from the date of treatment.'- In the case of a spot treatment the.guarantei only applies to :the specific area treated. After the first year a subterranean termite maintenance agreement is provided that may be extended annually for four (4) additional years upon payment o an annual extension fee. The maintenance agreement provides for the treatment .of an} subterranean termite infestation that may be discovered in the structure whilez the agreement is it force. The agreement does not provide for repairs of any damage caused by insects. The extension option is provided only when a completetreatment of the structure is conducted and is not applicable to spot treatments. Property Owner 76ry �jwd /ZleS Telephone Address Sec Me/ /U, Cif" /7 , i�s���i�,� Description of property to be treated 'L vt Dt:CJa. lu,a Property Location COST ESTIMATE USING THE FOLLOWING CHEMICAL: Additional Remarks _ - �ec6�v_r Annual Renewal $ T 0 A Copy of the appropriate chemical label and Consumer Information Sheet is attached. You should read the label and information sheet_ The proper application of a registered termiticide the soil beneath and around structures at rates called -for• by.the label offer tong on, as long as team; protecti the trea ed soil is not disturbed or the chemical barrier broken: Authorization of the termite treatment, by Vela's;should be indicated by the signing in the space Provided below. The signature should be of the property owner or the owner's agent of record and the person should be fully authorized to sign this"treatment acceptance. ACCEPTANCE OF TREATMENT S�rv�c� J 41-s11w TX -2 r- 7 Date / _"�7 cr'" Date �111717-13`�, 11 �9111WU �71- 711'^ av, VELAYS HIGH TECH PEST & TERMITE CONTROL SERVICE 120 Rebecca St. Bryan, TX 77801 (979) a2a;Mo P.C.L. 6900 "T DATE 11111E IN REG, Lj I.Tj ME ED RES. 0 COMM. AME 0 INDOOR OOR [3 OUTDOOR ADDRESS btliVICE REPORT i- '7e woo-sU�fTsop!urMMM Z08LL XZ `NVXNq £oZ gilris x99xD xHIXVD 009t, 99££-9VS-(6W TVs AH 800Z.UlDmAdOJ O 'ONI SNJIS�a • rN aU)QQaa Cl) T'LO(fl w Q z � z E-� � wwzZU)J w MF- z 0UZ CDQ O .,,.. Wz0() - >�OWWW 0 0 —j —j = Uu..I.LWW(n t981-908I #NV Id Ito-80 #90f S,.LNUWISRANI 'AVD f h6 31V0 xis Ao I-V 133HS wO3-su2 TSQP!rI-MMM 80-6Z-90 Z08LL X.L 'NV k-dq V58 i -9081 #NV Id :31VO £oz aLlns LtO-80 #SOf Ms xHRxD ,d91 vD 009t • • 80-6Z-s0 sNOISIA32I - RU SINgWISHANI *AV go-cz-so sNOlslnaiI-x.Ir 7 C 99££-91v8-(6L6) 8(M-so SNOISIAH-R19 433I ' TYX xfl SOOZ.LIIOINCdOJ O v J ��!' ' ;! L � . IIOII —lIIIII1 Ii—II d I I i ; I�I aI '; OU FWA/Mhy+•�1' {. ;;!•. reo;� T -II=� I T= 1II II �II1_—=-1II IIIIIIIIi II I I=IIIrV IIII1I _=-1 I E 1 I IQa00T.—x=� �WA, �' !!;aDLIIII DL�� OL 1L-=III—.LL . II LILIL(c� foy-IAL 1 4 N❑_LL1 ozit 0 O COP)Ou- ❑ LLJ I ; I a ! d mIIIIIIIIIIII! UOop WAW s 0ACS aC L — — — — — — — - J L — — — — — — — - J L Tf\ '--I EI=1 TI==- II I 1=U1 I LL11.1 D---------------.W O - ---�- ----------- - Qi� a FU�,', m.v-J ;�' IIII1-=='�III'I I=3I1 I-II�I-1� 1 •� N TI_IUII I I-i-I1I1II---IIIIII_T= 1I I11-1 -- --- -Uw0�0 O_OMUxG� � 4IIII--III�gII==_IIIIII --IIIIIIIII=1111 � ZVO -p = 1=III -� III III III111I-I W U. v am a W C�a0 O N to mill i �Ji J 8un Ed Q a O . IV N go w w a �gE � IIIIIIIIIIIIII M i A v • ��9BOX CLG CARPET i% __lo ..r 1 IIII U I" (� 1 iloo UVING ROOM SLOPED CLG. TILE �' r ��� ENEMA!; It . 3; BEDROOM #2 CARPET II 1 FIRST FLOOR SCALE: ,/B'=,'-0' LBE OF FIRST — —FLOOR BELOW _-J cum cla r P CJ.G--I F — g OLG7 ic BO �S ROOM x cLr BATH #4 BEDROOM #4 TILE n ( 'd'�-..,,.... ��1^` \/� o D AT. V �' ( 3.6-31. _ rAaFe=r IL ATTIC IACCES51 - : PKr. BATH IF3 3 cc CARPET — cm TILE 4 — — — — — — — LIVING ROOM 15 ' I ' ,aCLG. Kr. 14 ___.. _ 13 12 10 1 a I BEDROOM #3 I ti w 8 6' BOX CLG. O 5 I CARPET 4—CCLG.- 2060 D-L FOIEO 2040 D-L FIXED 1 2 3 8' CLG. rajly S�e_CXAJ w t --, M of 54vu 8A4cfelt AREA SUNEY ARY A/C - FIRST FLOOR 1208 SF A/C - SECOND FLOOR 646 SF A/C - TOTAL 1854 SF PORCH -FRONT 214 SF TOTAL SLAB 1422 SF TOTAL FRAMED 2068 SF i•w uw u S.H. CN 2'42'-4' LINE OF FIRST FLOOR BELOW 2SECOND FLOOR SCALE: 118' - I -G" FINISHING NOTES 1. 10' x 10' REAR PATIO 2. 3. 4. 5. a x (w O O N00 U v cn ON bA W o P><a o � �" b U.1i ndo�S t a� ArF U �" 3 � qy � AFF r��x• `� � � 3 3 DETAIL A SCALE: 114" - V-V IrC/i 00 O r� M� ray' W MOoc O �1 CoGoC* RQR 000 M00 w w w� w0con o N o H - _ _ S 4105ss}}5''26'1" W 7_ IDE SETBACK .411- lot — V-,t£ 3h,-43n I I ' I �0 of I m0 I � r� ° o , ZfA o m mm ° I ° z I A. co OTC rn ° I ° x N .p 00 Z I ° im° yl - cma I� I �L_ _ 5' SIDE " 22 m S E , °�0 °m�TS i C. TRUCK WASHOUT ° z N 400592-4"HERE 1 02.98' a vX '0O ;Ucl)j zMA ;az v ANNA STREET © COPYRIGHT 2008 BY R.A.I. SHEET BBJ - REVISIONS 05-26-08 (979)-846-3366 A_6 JTR - REVISIONS 05-27-08 C.W. INVESTMENTS • 4500 CARTER CREEK OF: BBJ - REVISIONS 05-29-08 JOB# 08-047 IFV*ao DESIG• SUITE 203 six DATE: PLAN# 1806-1854 �NS;, INC. BRYAN, TX 77802 05-29-08 1www.raidesigns.com BUILDING PERMIT CITY OF COLLEGE STATION t 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00001805 Date 6/30/08 Application pin number . . . 964665 Property Address . . . . . . 300 HOLIK ST Property ID: 332100-0004-0070 R #: R29286 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . HOLICK (CS) Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 122364 Owner Contractor ------------------------ WILDING, CHARLES ------------------------ VENABLE HOMES 4912 AUGUSTA CIR 2402 PLEASANT ROSE CIR COLLEGE STATION TX 77845 BRYAN TX 77808 (979) 224-3036 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 13.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 19.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA 01 GLAZING 12.00 GLAZING U-FACTOR .65 HEATED AREA 1854.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .40 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 311.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 584623 Permit Fee . . . . 529.00 Plan Check Fee .00 Issue Date . . . . 6/30/08 Valuation . . . . 122364 Expiration Date . . 12/27/08 Qty Unit Charge Per Extension -------------------------------------------- BUILDING DEPT REPRES TATIVE: Zitl� APPLICANT: BUILDING PERMIT CITY OF COLLEGE ISTATIUN ' 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00001805 Date 6/30/08 Application pin number . . . 964665 Qty Unit Charge Per Extension BASE FEE 460.00 23.00 3.0000 THOU BLDG, VAL 100001-500000 69.00 ---------------------------------------------------------------------------- Special Notes and Comments -Add Smoke Detectors per plans and code -Make sure 2nd Floor operable windows are 24" Above Finished Floor, and egress windows a maximum of 44" AFF. *ADD SMOKE DETECTOR(S) PER NOTES ON PLANS *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. *IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation -------------------------------------------------�-- --- ------------ BUILDING DEPT REPRES TATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00001805 Application pin number . . . 964665 Page 3 Date 6/30/08 Special Notes and Comments Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *Assure Proper GFI Locations,"Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 1501 the Values Shall be R-13 and R-30, above 1501 the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 * THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (20') OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER QODE SECTION R602.10 IN ------------------------------------------- -----Z--z 49 ------------ BUILDING DEPT REPRES rATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00001805 Date 6/30/08 Application pin number . . . 964665 ---------------------------------------------------------------------------- Special Notes and Comments 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 150-o of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200-o TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 15% is .65, from 15% to 2001 is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INS CTS AND DECAY --------------------------------------------- -----.......... -------- ,� alp BUILDING DEPT REPRE,�,PNTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00001805 Date 6/30/08 Application pin number . . . 964665 ---------------------------------------------------------------------------- Special Notes and Comments *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2006 IRC ) *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 529.00 529.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 529.00 529.00 .00 .00 -----------------------------------------------)6- ------------ - - BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00001806 Date 6/30/08 Application pin number . . . 050518 Property Address . . . . . . 300 HOLIK ST Property ID: 332100-0004-0070 R #: R29286 Application type description TEMP POLE Subdivision Name . . . . . . HOLICK (CS) Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ WILDING, CHARLES ------------------------ VENABLE HOMES 4912 AUGUSTA CIR 2402 PLEASANT ROSE CIR COLLEGE STATION TX 77845 BRYAN TX 77808 (979) 224-3036 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 584631 Permit Fee . . . . 20.00 Issue Date . . . . 6/30/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------------------------------•----------- BUILDING DEPT REPRESENPATIVE: APPLICANT: „r1 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning d D velopmeno Sendai WWW.CSTX.GOV ADDRESS/LOCATION: 300 !"r O I For Once Use Only DATE: _'J� -04RRCC REG APPLICATION # 08- 1 0 fyy� TEMP POLE # V 6 I `� (J 14 LOT BLOCK SUBDIVISION 401C CAt- SEC/PH BUSINESS/OWNER NAME: CL,d Ie 5 �+%i (4(; k PHONE: f1l 9- S75— W S191 CONTRACTOR/HOMEOWNER: YG►�Q�1�2 I-�D►^�25 PHONE: 110I — 2ZH—3036-r t' 1 OMB c� CONTACT PERSON FOR REVIEW COMMENTS: C0.I��V 0 e"4_- t- PHONE: q�q'Z'-H'3036 ,Zp-54� FAX: EMAIL: C�ilslodeNable. &A -a; 1 -col” ELECTRICIAN: H I c0 PLUMBER: 14d' A HVAC: A (2 C6H efi4 GOOD CENTS (Residential only): ACCESSORY/STORAGE —01 MOVING RE -ROOF ADDITION v NEW CONSTRUCTION' SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEL/RENOVATION* TENTS DESCRIPTION OF WORK:eu1 Ca+1sd{-:~c�iati PROPOSED USE: STRUCTURE USE: IZ_� HOMEOWNER ASSOC IATION/ARC H ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ 206 8 L VALUATION: $ TOTAL AREA: HEATED AREA: 18Sy (Cost bf Labor and Materials) 1:91"PUBLIC SEWER SEPTIC/TREATMENT SYSTEM ❑ SEWER TAP: EVI'5 '_ SIZE "" / WATER TAP: G C(r -Y11 SIZE ❑ OTHER TAP: SIZE TEMP POLE GARAGE TYPE: (j/ A SINGLE 71 ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: 1-1 L4 Woz"(y'4 I& ic.k/s;dLtiy_ 51" 30 V/ Cor�ot;4c DOUBLE F-] TRIPLE F] DETACHED F-] CARPORT F7 SIGNATURE OF APPLICANT: Gil/ "Li� *If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. ............................................................ Official Use Only `; V_0 8 Comments: NO Plans Examiner Zoning Official r u/:Ijow), -Ao(d r-5 r filly 5 "t/� Energy Code Compliance Information i % Glazing of exterior walls Insulation R value of exterior walls �3 Insulation R value of ceiling 1 (flat areas) 30 Insulation R value of ceiling 2 (vaulted areas/no attic) 19 � Glazing SHGC (Solar Heat Gain Coefficient) + `/O Glazing U-Factor • duo R value of ductwork 6 A/C SEER Rating /3 Protection Against Subterranean Termites D"' Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. PLAN REVIEW (*f/"" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning &DevclnpmrmSemica COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# /� ` r 8 O s- CJ DATE: r �_ BUILDING ADDRESS: L D L I. Foundation Requirements- Minimum Ci Foundation Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated N OK II. Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, rade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. K OK CITY OF COLLEGE STATION Planning cr Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements 10<1 A. Stairway Details N MOK2 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge I 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere J-, IV. Fireplace Requirements OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location (*t/q" CITY OF COLLEGE STATION Planning d Development Service; PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N K Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed A/ K "APPROVED PLANS PER IRC SECTION R106.3.1." P S XAMINER DATE