HomeMy WebLinkAboutRES2008-01753, 08-1754mg
WF1056165 /'001 City of Collegte Station PAGE 1
r,
REQ. DATE: 07/09/08 07/09/08 14:16:25
LOCATION: 1107 HOPEWELL CT LOC ID: 209780
REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 07/09/08 SCHED COMPLETION: 07/09/08
********************************************************************************
JOB ORDER RESULT COMlENTS
PREPARED 12/01/08, 7:53:08 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/26/08
------------------------------------------------------------------------------------------------
ADDRESS . : 1107 HOPEWELL CT SUBDIV: SHENANDOAH PH 11
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER ED FROEHLING BUILDER INC PHONE
PARCEL 569500-1135-0290
APPL NUMBER: 08-00001753 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 8/07/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00
8/07/08 AP August 7, 2008 9:43:17 AM bboerboom.
B115 01 8/14/08 RH BLDG, FRAMING TIME: 17:00
8/14/08 AP August 14, 2008 11:55:48 AM ccourt.
APA
APA
B130 01 10/06/08 BB BLDG, INSULATION TIME: 17:00
10/06/08 AP October 6, 2008 10:34:28 AM bboerboom.
B125 01 11/26/08 BI BLDG, FINAL TIME: 17:00
November 26, 2008 2:58:35 PM glsouth.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
5
11/26/2008 15:52 9797740565 ED FROEHLING BUILDER PAGE 06/07
�psn.*:.i:vr. • r Via-
TEXAS SPCE TERMITE TREATMENT DISCLOSURE DOCUMENT
Prone Ow ejn FROEHLING HOMES
�4�"►• on.. lrLbE2 �r@ i 1107 HOPEWELL
2837
entaa a id �.xo be aWi4N 2 i8 lODAti= RMJ.Q:.0-0AL
ryw, of Ire nf- Full uart x—
Horizontal/Perimleter Seam_XX
�SkBESIDemE ,Soof: -ow-QSJTION,
�.�Lvl;3iias��[�d��i,�so.,albl.�d �S Dirt of this r�cumerrt
LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT, WARRANTY INFORMATION (IF ANY)
4CLUPING AREA COVERED, TIME Pwroo OF WARRANTY, RENEWAL OPTIONSAND COST THE ORLIGATION8 OF TKE PEST CONTROL OPERATOR TO RE.
RBAT FOR TERMITE INFESTATIONS OR REPAIR bAMA08 CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT
OULD DEVKQP AS A RR$ULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO SEEN ATTACHED,
:barges for pre -treat:
10TES: Annual renewal:
$414.49
$130.00
32129 PT. 8M2008
CA or ToWndm Sppg k-mm V $2129 PT
11/26/2008 15:52 9797740565 ED FROEHLING BUILDER PAGE 07/07
ACE PEST CONTROL
T.P.C.L. # 7120 PT
PO BOX 4474
BRYAN, TX 77805
(979) 82X7777
(979) 7744736
CERTIFICATE
The following property 1107 A gg` �.
built by FROEHLJNQ,HOMES „ _ _State of Texas
County of BRA_&the city of COLLEGE ST . TION
Mailing Address SAME , Zip code 77845
was treated for subterranean termites on this day AUG_7ST 07a 2008,„and has met
with approval. Cost of initial treatment, 414,49 is payable upon completion of work.
The treatment is guaranteed for 12 months from the date of treatment. Thereafter, this
contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection
and renewal fee of 130lus tax, for a period of 4 years, ( see attached letter) If
at any time during this contract a reinfestationi of subterranean termites should occur, the
above said properly will be treated at no additional cost to the owner. ACE PEST
CONTROL does not accept any liability for any subterranean termite damage repair.
Failure to pay the annual renewal, fee within thirty days after the inspection, date shall be
construed as a cancellation, of this contract. Any alteration or addition to the foundation
of the above described property without proper termite treatment by ACE LEST
CONTROL Services shall nullify this contract.
Licensed and Rcgulatod by the
Texas lacpartment of Agriculture.
Structural Pcst Control service,
PO Box 12847, Austin, Texas 79711-2847
(512) 305-8250
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning of Dsyslapment Serviea
WWW.CSTX.GOV
ADDRESS/LOCATION: L V ( )
LOT I BLOCK) SUBDIVISION
BUSINESS/OWNER NAME:
For Off" us* 0*
DATE v w0 ITRCC REG 73 S
APPLICATION # 0 9 - ! //--(�� �
TEMP POLE M off -,r7/
PHONE:
CONTRACTOR/HOMEOWNER: E b TROE 01..10121 15UILOC-!2 PHONE: —mg -&U-CO
a
CONTACT PERSON FOR REVIEW COMMENTS: �t`rI PHONE: TT 4-00UP'S
SEC/PH I
FAX:
ELECTRICIAN: 159 s5 IEXG"MIC.
HVAC: `iGa % tjtj0VB►T1-49
EMAIL:
PLUMBER: TR �1aLE
GOOD CENTS (Residential only):
ACCESSORY/STORAGE OVING RE -ROOF
ADDITION NEW CONSTRUCTION* SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEL/RENOVATION*
DESCRIPTION OF WORK:
PROPOSED USE:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATIIOOQN# EABPRJ
VALUATION: $ W1 i (oe6,,0D TOTAL AREA: 28HEATED AREA: 'O-ZC-45
(Cost of La or and Materials)
Mop"UBLIC SEWER NUMBER OF BEDROOMS: rJ
SEPTIC/TREATMENT SYSTEM
SEWER TAP: 4-NI
SIZE
[jrWATER TAP:
W
0•
SIZE
❑ OTHER TAP:
SIZE
dTEMP POLE
GARAGE TYPE: SINGLE a
ATTACHED d
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE EZ( TRIPLE
DETACHED
SIGNATURE OF APPLICANT: \_)V\`'�l
*If proposed work involves new commerr onst n or aca�
commercial property, building elevations ar required.
Official Use Only
Plans Examiner Zoning Official
ry
�- f::� r
9
IW
novations to an existing
Co ments:
ES rN0
O/40LIlelissr..*,(e 1�
i��
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
Chemical Termiticide Treatment (Soil Treatment
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
t� **�-.. ar�1.,� -.\tv. ♦•. �\� a !!.ty_i..'�a
•��•`\S"/ `vv�itt �tN-,I(;� \ . 1�1.. Vet ...`✓i t .
R aw
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\l 107HW.rck
TITLE: 1107 Hopewell Court
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 07/09/08
DATE OF PLANS: 12/14/07
PROJECT INFORMATION:
LOT 29 BLOCK 35
SHENANDOAH PHASE 11
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
3887 HIGH LONESOME ROAD
COLLEGE STATION, TX 77845
NOTES:
Narrow 5-bedroom 46' 0" wide
COMPLIANCE: Passes
Maximum UA = 757
Your Home UA = 618
18.4% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.38
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Front
Projection factor: 0.18
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Left Side
Projection factor: 0.18
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2268
30.0
0.0
79
395
13.0
0.0
22
88
0.650 57
38 0.400 15
506 13.0 0.0 39
27 0.650 18
Wall 3: Wood Frame, 16" o.c.
408
13.0 0.0 26
Window 3: Metal Frame:Double Pane with Low-E
61
0.650 40
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.33
Door 2: Glass
36
0.580 21
SHGC: 0.78
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor; 0.81
Wall 4: Wood Frame, 16" o.c.
506
13.0 0.0 37
Window 4: Metal Frame:Double Pane with Low-E
57
0.650 37
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Unheated
218
0.0 227
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb ( erly MECchec,i and to comply with the mandatory requirements listed in
the RES checklnsnee ' n i klist. d A i A I- .
Builder/Designer \ Date Q
Jun. 10. 2008 4:48PM McClure & Browne Eng;Surveying, No. 4301 P. 2
�1eCLUREdBRdlyNE6yG/r�EF�/Ni'U!'VEY/NG, /NC• 1Gb8f4'aadcrz�,�D S�irfQ �1J3• Co!/bo� Texas 178'• 19 69,�38,1d
Lot 29 Block Mdwg >�
Lot 30
Now or Formerly
Ed Froehling Builder, Inc.
Vol. 8288, pg. 82
Edward Fruehling,
Rema/nder of 49.3S Acres
Vo4 4248, Rp, 144
N 4526J6 0 E 65 00'
}-10' P.U.E. — —
r
Nm
Note: Building Setback Lines per
1
City of College Station Unified
Development Ordinance 12617
1107 Hopewell Court
Lot 29, Block 35
Shenandoah Phase It
Ti
cy,,
\ ...J �J
Proposed
Residence
Iff
? 7, 42.0'
Proposed
Driveway
�I
J 4 L8"36w !7 — 65 00'
Hopewell Court
50' R.D.W. - 27' Pavement
voi. 82s8, Pg. 82
Lot 2a
Now or Formerly
Ed Froehling Builder, Inc_
f.
Vol. 8288, Pg. 82
Rx `
r
,N I
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, —TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00001753 Date 7/09/08
Application pin number . . . 312196
Property Address . . . . . . 1107 HOPEWELL CT
Property ID: 569500-1135-0290
R #: R306395
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . SHENANDOAH PH 11
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 179520
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDER INC ED FROEHLING BUILDERS
3887 HIGH LONESOME 3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struc_t info . . . . . A/C SEER RATING 13.00
CEILING 1 R VAL. (FLAT) 30.00
CEILING 2 R VAL-NO ATTIC 19.00
DUCT R VALUE 6.00
EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID DUE
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
GLAZING 10.73
GLAZING U-FACTOR .64
HEATED AREA 2720.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 5.00
EXTERIOR WALL INSUL R VAL 13.00
GLAZING SHGC .40
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 427.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 585992
Permit Fee . . . . 700.00 Plan Check Fee .00
Issue Date . . . . 7/09/08 Valuation . . . . 179520
Expiration Date . . 1/05/09
------------------------------------------ ----vim/• •-------------
BUILDING DEPT REPRESENTATIVE.
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00001753 Date 7/09/08
Application pin number . . . 312196
Qty Unit Charge Per Extension
BASE FEE 460.00
80.00 3.0000 THOU BLDG, VAL 100001-500000 240.00
----------------------------------------------------------------------------
Special Notes and Comments
-Be aware and do not build in the left side 10' PUE
-Narrow Wall Bracing Fully Sheathed with Possible 16"
Minimum Garage APA Framing if it does not meet 24" Min. OSB
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 05 Nat' nal lectrical
4 -
'�''A9.11-------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00001753
Application pin number . . . 312196
Page 3
Date 7/09/08
Special Notes and Comments
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 15% the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
* THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED
AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN
2006 IRC
------------------------------- -----S - -y-----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE S.TATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00001753 Date 7/09/08
Application pin number . . . 312196
----------------------------------------------------------------------------
Special Notes and Comments
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR
HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE
UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR
COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL
BE PERFORMED PRIOR TO FRAMING INSPECTION.
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE
LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 250-o is .46 or
lower.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN,EACH SLEEPING R OM AND OUTSIDE EACH
-------------- ------------- -
--------- -'-----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: ��
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number . . . . . 08-00001753 Date 7/09/08
Application pin number . . . 312196
----------------------------------------------------------------------------
Special Notes and Comments
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2006
IRC)
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
*GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
*PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR
CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY
BEING ELEVATED A MINIMUM OF 18" ABOVE FLOOR LEVEL.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . IMPACT FEE AREA 97-01 98.39
SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 700.00 700.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 848.39 848.39 .00 .00
Grand Total 1548.39 1548.39 .00 .00
---------------------
----- ---- - ��,v------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXkS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
08-00001754 Date
7/09/08
Application pin number . . .
405928
Property Address . . . . . .
1107 HOPEWELL CT
Property ID:
569500-1135-0290
R #:
R306395
Application type description
TEMP POLE
Subdivision Name . . . . . .
SHENANDOAH PH 11
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
ED FROEHLING BUILDER INC
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
3887 HIGH LONESOME RD
COLLEGE STATION TX .778459443
COLLEGE STATION
TX 77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . GS
Permit pin number . 586008
Permit Fee . . . . 20.00
Issue Date . . . . 7/09/08
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
----------------------------------------- jul� ------------ * ---------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT-,,—
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Nanning& Development Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# ITO
DATE:
BUILDING ADDRESS:
07 ew�l .
I. Foundation Requirements- Minimum Ci Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
Il. Framing: Floor, Wall, Ceiling and Roof Requirements
NAtW
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
ffAtM
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R.
S.
18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
All walls within 3' of property line to have protected openings.
K
OK
�f PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
l'lanning&Development Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
NAt&K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1 /2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N K
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
/ PLAN REVIEW
(*t/qq,4 ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning 6-DcvdopmcnrStrvica COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NLkM
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N K
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N K
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N K
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA K
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
J_ � L. & - (0- 8
LA )(AMINER DATE
No
I
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
(*hrq" COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d Devdopmrnr Srrvira
WWW.CSTX.GOV
ADDRESS/LOCATION: (i of go"ell "eft Coorr ✓
LOT i LOCK '?5 SUBDIVISION gk-.µNNDVA SEC/PH
BUSINESS/OWNER NAME: PHONE:
'77(0 '021A000NTRACTOR/HOMEOWNER: E b 13UILOW., PHONE: CONTACT PERSON FOR REVIEW COMMENTS: PHONE: 714-051507
FAX. ���•U5� EMAIL:
ELECTRICIAN: f5i' 15 MACMIC- PLUMBER: Tf? %PLE
! HVAC: `.i� %00c)VAc -49 GOOD CENTS (Residential only):
) t ACCESSORY/STORAGE OVING RE -ROOF
` �O
ADDITION NEW CONSTRUCTION SHELL ONLY
I DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
�• DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
l rL LOCATION REMODEURENOVATION"
1 l DESCRIPTION OF WORK:
PROPOSED USE:
STRUCTURE USE'.
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ "
VALUATION: $ 1-7q 157-0n° TOTAL AREA: SVS(A HEAT F
(Cost of Labor and Materials)
NePUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP:
$1
44� INTERIOR WALL TYPE:
15 mr',
Ei?GWATER TAP:
SIZE
514 g, EXTERIOR WALL TYPE:
OTHER TAP:
SIZE
FOUNDATION TYPE:
SIZE
TEMP POLE
ROOF TYPE:
� �
�..T MV�
GARAGE TYPE:
SINGLE a DOUBLE EV" TRIPLE
ATTACHED Ej-4` DETACHED
F
rCARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial c&As1r&tLQrMr1Acade improve(Tnts/renovations to an existing
commercial property,
building elevations are required.
............................................................
Official Use Only
64*4 " w/14 Plans Examiner
— LrO S Ede rb` j0UE
1P zy
Comments:
or NO
Zoning Official
A� ny lLtilk� W1P0 ss► b I1e &AnApZ AP4, ka«4
1
,Enerky Code Compliance Information
% Glazing of exterior walls .� 317o
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
•
Glazing U-Factor . G(4"
R value of ductwork
A/C SEER Rating ✓ L C } ; r
Protection Against Subterranean Termites
Chemical Termiticide Tre
atment (Soil Treatment)
a
❑ Chemical Term-iticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
Y�i�:li•ti:5�nr 1 ;� •. \'"� t.^���.1Yk\ 1. � r: g: iZ i G � �, '',ate �'� .a'a.:�l- �� j~ :i.1t _"
R�
20' P.U.E. N 45 26' 36" E - 65.0'
�10' P.U.E.
J c
m
r`
I
0 9:800 c ,
o I o
o Lot
29 block 35 0
Lot 30 Block 35
1107 flopeweLL oM Lot 28 Block 35
Court I
N Proposed er
Residence N
M M
M
Shenandoah Phase 11
- ------ 42.0'
13.1 9 '
1
- t Corvcret�
Driveway
I
N 45 26' 36" E - 65.0'
flopeweLL Court
50' R.O.W. -- 27' Pavement
Scale 1 " = 20'
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\l 106BC LILLY.rck
TITLE: 1107HW
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 06/04/08
DATE OF PLANS: 3/12/08
PROJECT INFORMATION:
1107 HOPEWELL COURT
LOT 29 BLOCK 35
SHENANDOAH 11
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
LILLY
COMPLIANCE: Passes
Maximum UA = 991
Your Home UA = 705
28.9% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.29
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.40
Permit Number
Checked By/Date
pLJL:-P<X-'-
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2013
30.0
0.0
70
707
30.0
0.0
25
336
13.0
0.0
21
44
0.640 28
38
510 13.0 0.0
29
0.400 15
39
0.640 18
ri •
Wall 3: Wood Frame, 16" o.c.
336
13.0 0.0
20
Window 3: Metal Frame:Double Pane with Low-E
75
0.640
48
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.29
Door 2: Glass
18
0.580
10
SHGC: 0.78
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.25
Wall 4: Wood Frame, 16" o.c.
510
13.0 0.0
38
Window 4: Metal Frame:Double Pane with Low-E
46
0.640
30
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor: 0.29
Wall 5: Wood Frame, 16" o.c.
229
13.0 0.0
19
Wall 6: Wood Frame, 16" o.c.
327
13.0 0.0
23
Window 5: Metal Frame:Double Pane with Low-E
51
0.640
33
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.40
Wall 7: Wood Frame, 16" o.c.
229
13.0 0.0
19
Wall 8: Wood Frame, 16" o.c.
327
13.0 0.0
26
Window 6: Metal Frame:Double Pane with Low-E
4
0.640
3
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor: 2.00
Floor 1: Slab -On -Grade: Unheated
211
0.0
220
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here
is consistent with the building
plans, specifications,
and other calculations submitted with the permit application. The
proposed
building has been designed to
meet the 2000 IECC
requirements in REScheckVersion 3.5 Release I (formerly MECchec/ and to comply with the mandatory
requirements listed in
the REScheckInspection Chec list.
Builder/Designer
/
Date 60 1