HomeMy WebLinkAboutDEMO2008-01741i1�• rl'tl
DEMOLITION PERMIT
CITY OF COLLEGE STATION
1101 'TEXAS ' AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
PK REAL PROPERTIES-HOLLEMAN
CENTER,
15011 LAWNDALE DR
HOUSTON TX 77017
08-00001741 Date 3/23/09
602425
2054 HOLLEMAN DR W
384800-0102-0010
R107359
DEMOLITION, COMMERCIAL
LEGACY ADDITION PH 1
UNKNOWN
5000
Contractor
R.A.I . DESIGNS INC
4500 CARTER CREEK #203
BRYAN TX 77802
(979) 846-3366
--- Structure Information 000 000 DEMO OLD CAR WASH
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . UTILITY AND MISCELLANEOUS
----------------------------------------------------------------------------
Permit . . . . . . DEMOLITION PERMIT
Additional desc . . GS
Permit pin number . 641068
Permit Fee . . . . 25.00 Plan Check Fee .00
Issue Date . . . . 3/23/09 Valuation . . . . 5000
Expiration Date . . 9/19/09
Qty Unit Charge Per Extension
BASE FEE 25.00
----------------------------------------------------------------------------
Special Notes and Comments
*ALL UTILITIES MUST BE DISCONNECTED BEFORE DEMOLITION
BEGINS. PLUMBING SEWER LINES MUST BE CAPPED TO AVOID STORM
WATER FLOWING INTO LINES. MAINTAIN SAFE JOB SITE AND REMOVE
ALL DEBRI PROMPTLY.
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*ALL IRRIGATION, PLUMBING, ELECTRICAL, AND HVAC (mechanical)
WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT
BUILDING DEPARTMENT FOR PERMITS PRIOR TO WORK, & INSPECTIONS
PRIOR TO COVERING ANY WORK (979)764-3570.
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
DEMOLITION PERMIT
CITY OF COLLEGE STATION
1101 TEXAS'AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00001741 Date 3/23/09
Application pin number . . . 602425
---------------------------------------------------------
Permit Fee Total 25.00 25.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 25.00 25.00 .00 .00
------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: 11__ A,-!:' \*N n,;
ri
Fa Ofil- Use only
�1 APPLICATION FOR BUILDING PERMIT DATE: C0•0
'' IRQC'R'EG
CITY OF COLLEGE STATION APPLICATION # l��
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE #_ "
Farr of CC)1.,1 ta:Ei S 17"U'RYNN (979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV W
ADDRESS/LOCATION: �2 C
LOT BLOCK SUBDIVISION L e H a c,4 .401G ; ttI !GW%EC/PH
BUSINESS/OWNER NAME: PiaS oxo� Kon erw. ( • J9. PHONE: 713 - %f
CONTRACTOR/HOMEOWNER: PHONE:
CONTACT PERSON FOR REVIEW COMMENTS: Uo h ri F'1 hod es PHONE:
FAx: EMAIL: � j f-r h o Alps ra i a✓rSiry�iS .��� �-
ELECTRICIAN: 8r✓ eC C/' �/ fc.T'PLUMBER: H A Plum Cl / n A
HVAC: M/z
GOOD CENTS (Residential only):
ACCESSORY/STORAGE OVING RE -ROOF
ADDITION WEW CONSTRUCTION* SHELL ONLY
�EMOLITION.(ASBESTOS SURVEY PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEURENOVATION' TENT
RETAINING WALL
DESCRIPTION OF WORK:
PROPOSED USE:
O Aed/171.� �y
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVA '
TEXAS ACCESSIBILITY STANDARD (TASS)`1PROJECT REGISTRATION NO. EABPRJ
VALUATION: $ 5 000 Q TOTAL AREA: 455 HEATED AREA: o <
e (Cost of Ldbor and Materials)
�vPUBLICSEWER
71 SEPTIC/TREATMENT SYSTEM
SEWER TAP:
WATER TAP:
OTHER TAP:
7
--,.,TEMP POLE
GARAGE TYPE:
SIZE
SIZE
SIZE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS: O
INTERIOR WALL TYPE: NZ`!'
EXTERIOR WALL TYPE: _N /QQ 0 � 8,,,-Ck
FOUNDATION TYPE: P`Gr +- COn ciC kC Gfwl/7
ROOF TYPE: roll-ed Gc oA.j.
SINGLE a DOUBLE Q TRIPLE
ATTACHED DETACHED CARPORT
SIGNATURE OF APPLICANT:
'If proposed work involves new co 4
on or facade improvements/renovations to an existing
commercial property, building el tions are required.
...........................................................
Official Use Only
Comments:
?_f�br NO
Plans Examiner Zoning Official
PLM Summary Report
Steve Moody Micro Services, LLC NVLAP Lab No. 102056
2051 Valley View Lane TDSHS License No. 30-0084
Farmers Branch, TX 75234 (Phone 972-241-8460)
Client : Austin Environmental, Inc. Lab Job No.: 09B-02870
Project : Legacy Retail Center Car Wash, 2054 Holleman Dr. West Report Date: 03/14/2009
Project # : AE09-89 Sample Date: 03/13/2009
Identification : Asbestos, Bulk Sample Analysis
Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116 Page 1 of 1
On 3/14/2009, one (1) bulk material sample was submitted by Brent Plant of Austin Environmental, Inc. for asbestos analysis by PLM/DS. The PLM
Detail Report is attached; additional information may be found therein. The results are summarized below:
Sample Number
Client Sample Description / Location
Asbestos Content
L-01
Expansion Joint Caulking, West Side by Drive-thru
None Detected - Caulking
These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual r^ —� ^
estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These
test results do not imply endorsement by NVLAP or any agency of the U.S. Government. Accredited by the
National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056.
Analyst(s): Kirsten Tye
Lab Manager: Bruce Crabb Approved Signatory
Lab Director: Steve Moody Approved Signatory
— — — — — — — — Thank you for choosing Steve Moody Micro Services