HomeMy WebLinkAboutCNEW2008-0171711
V�-tu � -Datef
Permit # � � `
pvqruo
Project Name
e
1
et ��cy
COMMERCIAL CO
Planning
(Lindsay Boyer, Jennifer Prochazka, Jennifer Reeves, Crissy Hard, Jason Schubert, Grant Wencel, Molly Hitchcock)
Bridgette George
Development Engineers
(Alan Gibbs, Josh Norton, Carol Cotter)
City Engineer
(Bob Mosley, Jerry Jones, John Logan, Robert Bumpurs, William Ethridge)
Environmental Services Q�
(Eaphrame Thomas, James Boykin, Pete Garcia)
Fire Department
(Eric Hurt, Eric Dotson, Jerry Duffey, Steve Smith)
Drainage
(Donnie Willis)
Public Works - Sanitation
(Wally Urrutia)
EIectrical Services
(Tony MidWsky)
Water/Wastewater Services
(Joe Mike Garcia, Paul Schoenfeld, Mitchell Carson)
Miscellaneous Notes
PREPARED 11/12/08, 8:02:21 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/11/08
------------------------------------------------------------------------------------------------
ADDRESS . : 1604 COPPERFIELD PKWY 200 SUBDIV: CRESCENT POINTE PHASE 1
TENANT, NBR: THE LIERE AGENCY
CONTRACTOR LEGEND BUILDER, INC PHONE (979) 774-4600
OWNER WJP OFFICE LLC PHONE
PARCEL 212200-0102-0020
APPL NUMBER: 08-00001717 COMMERCIAL, OFFICES/BANKS/PROFESSION
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 6/26/08 DS BLDG, FOUNDATION -SLAB TIME: 17:00 '
6/26/08 AP June 25, 2008 10:32:48 AM acarter.
THURSDAY MORNING PLEASE
B115 01 8/20/08 DS BLDG, FRAMING TIME: 17:00
9/02/08 DP August 20, 2008 2:41:00 PM glsouth.
locked
B115 02 9/02/08 DS BLDG, FRAMING TIME: 17:00
9/03/08 AP September 2, 2008 3:55:29 PM glsouth.
B130 01 9/02/08 DS BLDG, INSULATION TIME: 17:00
9/03/08 AP September 2, 2008 2:17:49 PM glsouth.
B125 01 1 / 1/08 ` BLDG, FINAL TIME: 17:00
% U� November 11, 2008 3:38:39 PM ccourt.
---+-------------------------if--- CONTINUED ONTO NEXT PAGE -----------------------------------
G*�
(11/14/2008) Gina Southerlard - Re: Calling for CO @ 1604 Copperfield Pkwy Ste 200 Page 1
From: Jerry Duffey
To: Christina Court
Date: 11/14/2008 11:04 AM
Subject: Re: Calling for CO @ 1604 Copperfield Pkwy Ste 200
CC: Benjamin McCarty; Chris Haver; Eric Dotson; Eric Hurt; Gina Southerland
NO issues from Fire.. clear for a CO now............
>>> Christina Court 11/13/2008 12:26 PM >>>
The Liere Agency
by#08-1717
Any issues, please contact the contractor Legend Builders @ 774-4600.
Thank you!
Christina Court
CSR
Planning & Development
City Of College Station
979.764.3570
(*//4"
CITY OF COLLEGE STATION
Property Address:
Company Name:
Buginess Name:
Application to Stock/Fixture/Move-in Prior to
Issuance of a Certificate of Occupancy
Property Owner or Manager Information:
Name:
Address
City, St
Phone:
Construction Company Information:
Name: S
Address: 6us-
City, State, Zip: l'�/ � 5��. A"I
Phone: c,/ 6 0o Mobile:
I am applying for permission to:
4 Move furniture and/or equipment into the building
Fixture and/or stock the building
Conduct training for staff members only
Other (Be Specific)
I hereby make application to the City of College Station to perform the action(s)
indicated above without the benefit of a Certificate of Occupancy. I certify that the above
statements are true and correct. I understand that occupancy of a structure prior to
obtaining a Certificate of Occupancy is a code violation and may result in the issuance of
citation(s). I further understand that fines associated with citations range up to $2,000.00
per day.
Applicant Signature:
Printed N me: v� crr►
Date: D
♦♦11111111111111111111111111111111111♦ ♦1111111111111111111111111♦
Building Department Representative: ----
Comments:
Date:
(,11%14/2008) Gina Southerland - Call!ng for CO @-1604 Coppefield Pkwy Ste 200 y Page 1
From: Christina Court
To: CO Group
Date: 11/13/2008 12:27 PM
Subject: Calling for CO @ 1604 Copperf!eld Pkwy Ste 200
The Liere Agency
by#08-1717
Any issues, please contact the contractor Legend Builders @ 774-4600.
Thank you!
Christina Court
CSR
Planning & Development
City Of College Station
979.764,3570
(11/14/2008) Gina Southerla!id Ri .xCalling for CO @ 1604 Copperfield,rPkwy Ste 200 __. Page 1
From: Rodney Harris
To: Alan Gibbs; Benjamin McCarty; Brenda Godfrey; Brent Read; Bridgette ...
Date: 11/14/2008 10:35 AM
Subject: Re: Calling for CO @ 1604 Copperf!eld Pkwy Ste 200
No Sanitation Issues!
Rodney Harris
Sanitation Foreman
Public Works
Tel(979)764-3698
Fax(979)764-3489
email: rharris@cstx.gov
>>> Christina Court 11/13/2008 12:26 PM >>>
The Liere Agency
by#08-1717
Any issues, please contact the contractor Legend Builders @ 774-4600.
Thank you!
Christina Court
CSR
Planning & Development
City Of College Station
979.764.3570
(11/14/2008) Gina Southerland Re Calling for CO @ 1604µCopp erfield Pkwy Ste 200 Page 1
From: Pete Garcia
To: COS
Date: 11/13/2008 3:44 PM
Subject: Re: Calling for CO @ 1604 Copperfield Pkwy Ste 200
Attachments: Pete Garcia.vcf
They are OK.
Do not ask the Lord to Guide your Footsteps if you are not willing to move your Feet'
This e-mail and/or attachment is for the sole use of the intended recipient(s) and may contain confidential and /or legally privileged
information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please
contact the sender by reply e-mail and destroy all electronic and paper copies of the original message and any attachments. Thank
You.
>>> On 11/13/2008 at 12:26 PM, in message<491C1D0Q.5352.0048.0@csb(.gov>, Christina Court wrote:
The Liere Agency
by#08-1717
Any issues, please contact the contractor Legend Builders @ 774-4600.
Thank you!
Christina Court
CSR
Planning & Development
City Of College Station
979.764.3570
(11/14/2008) Gina Southerland - Re: Calling for CO @ 1604 Copperfield Pkwy Ste 200 Pa„1
_._.. _ a a
From:
Jerry Duffey
To:
Christina Court
Date:
11/13/2008 3:02 PM
Subject:
Re: Calling for CO @ 1604 Copperfield Pkwy Ste 200
CC: Benjamin McCarty; Chris Haver; Eric Dotson; Eric Hurt; Gina Southerland
OK for Temp CO from Fire...needs key for the Knox Box
>>> Christina Court 11/13/2008 12:26 PM >>>
The Liere Agency
by#08-1717
Any issues, please contact the contractor Legend Builders @ 774-4600.
Thank you!
Christina Court
CSR
Planning & Development
City Of College Station
979.764.3570
BUILDING PERMIT
CITY OF COLLEGE STATION
' 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #•
Tenant nbr, name . . . . . .
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00001717 Date 6/19/08
354776
1604 COPPERFIELD PKWY 200
212200-0102-0020
R302594
THE LIERE AGENCY
COMMERCIAL, OFFICES/BANKS/PROFESSION
CRESCENT POINTE PHASE 1
UNKNOWN
250000
Owner Contractor
WJP OFFICE LLC LEGEND BUILDER, INC
1604 COPPERFIELD PKWY P.O. BOX 9356
STE 100 COLLEGE STATION TX 77842
COLLEGE STATION TX 778453994 (979) 774-4600
Structure Information 000 000
Construction Type
. . . . . **NEEDS TO BE ENTERED**
Occupancy Type .
. . . . . **NEEDS TO BE ENTERED**
Other struct info
. . . . . EXTERIOR WALL TYPE NA
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE NA
HEATED AREA
4000.00
INTERIOR WALL TYPE NA
SEWER TYPE NA
TRAFFIC IMPACT ANAL (TAZ)
164.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. AC
Permit pin number
. 582080
Permit Fee . . .
. 910.00 Plan Check Fee
.00
Issue Date . . .
. 6/19/08 Valuation . . . .
250000
Expiration Date .
. 12/16/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
150.00 3.0000
THOU BLDG, VAL 100001-500000
450.00
----------------------------------------------------------------------------
Special Notes and
Comments
PROVIDE ADDRESS
ON COMMERCIAL BUILDINGS -FRONT: 5" ADDRESS
NUMBERS, AND ON
REAR DOOR(S): 2" HIGH ADDRESS NUMBERS AND
NAME OF BUSINESS.
FOR MULTI -FAMILY RESIDENTIAL PROVIDE UNIT
NUMBER ON FRONT
DOOR AND IDENTIFY EACH UNIT FROM A REAJZ FIRE
-------------------------------------------------
BUILDING DEPT
REPRESENTATIVE:,,,, - C --- 9-AI44 ---------------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00001717
Application pin number . . . 354776
Special Notes and Comments
Page 2
Date 6/19/08
LANE. IDENTIFY MULTI -FAMILY BUILDINGS WITH 12" BUILDING
NUMBERS, VISIBLE FROM ALL ADJACENT/NEARBY FIRE LANES. ALL
NUMBERS AND LETTERS SHALL HAVE CONTRASTING BACKGROUNDS.
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
REQUIRED EXIT DOOR(S)
SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN
AND INSTALL AS PER NFPA 72
NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND
RETURNED
PROVIDE FIRE EXTINGUISHERS) - VERIFY LOCATION AND PLACEMENT
WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC)
SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW
NO WORK ON SPRINKLER SYSTEM SHALL
BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED.
SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE
REQUIRED TO BE MONITORED BY AN APPROVED MONITORING
COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE
SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE
PREVENTION DIVISION.
PROVIDE MINIMUM 42" CLEARANCE FROM CENTER LINE OF WATER
CLOSET TO EDGE OF LAVATORY OR WALL TO COMPLY WITH ANSI 2003,
ACCESSIBLE STANDARDS.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
INTERIOR LIGHTING SHALL MEET THE CONTROLS AND WATTAGE
REQUIREMENTS OF SECTION 505 OF THE 2006 INTERNATIONAL ENERGY
CONSERVATION CODE.
All roof and ground -mounted mechanical equipment shall be
sreened from view or isolated so as not to be visible from
any public right-of-way or residential district within 150
feet of the subject lot, measured from a point five feet
above grade. Such screening shall be coordinated with the
building architecture and scale to maintain a unified
appearance. Acceptable methods of screening rooftop
equipment may include, but are not limited to encasement,
parapet walls, or partition screens.
PROVIDE PANIC HARDWARE ON EXIT DOORS
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
Fee summary Charged Paid Credited Due
- - - - - ----------------------------------------------------
------------------------------------------------ "4 ----------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . .
Application pin number
Permit Fee Total
Plan Check Total
Grand Total
. . . 08-00001717
. . . 354776
910.00 910.00
.00 .00
910.00 910.00
Page 3
Date 6/19/08
.00 .00
.00 .00
.00 .00
----------------------------------------------- ----------------
BUILDING DEPT REPRESFT�'ATIVE
-n
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGr STATION (979) 764-3570 (979) 764-3496 FAX
pin+ning d- Unrlopn+eat e-krr
WWW.CSTX.GOV
ADDRESS/LOCATION: 1 Nf�7 / / CIP-1-4;-
�jForOT+ Use Only
DAT IC5 4O TR CI
APPLICATION #
-D.Z
TEMP POLE #__
LOT BLOCK Z SUBDIVISION eke-S694rr SEC/PH
BUSINESS/OWNER NAME: Z'eS116 �1Pi�E PHONE:
CONTRACTOR/HOMEOWNER: ` k!WW 7_111d*10 A/ : PHONE:
CONTACT PERSON FOR REVIEW COMMENTS:�` 11YN6/V PHONE:
FAX: EMAIL: 112 !le' tq? / ,6 vS110?/n 0IW'1/
ELECTRICIAN: Dewht_7g `- ` PLUMBER: ✓6-AAJ
HVAC: hod- /!?��!%��j GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION'` SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEL/RENOVATION' TENT
RETAINING WALL Id - F1
DESCRIPTION OF WORK:
PROPOSED USE:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: NlIiQ
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION NO. EABPRJ
VALUATION: $ Z56VO6 TOTAL AREA: HEATED AREA:
(Cost of Labor and Materials)
0 PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
❑ SEWER TAP:
❑ WATER TAP:
❑ OTHER TAP:
P TEMP POLE
GARAGE TYPE
SIZE
SIZE
SIZE
SINGLE El
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE
DETACHED F-1
TRIPLE El
;ARPORT
SIGNATURE OF APPLICANT:
"If proposed work involves new c rc al construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
............................................................
Official Use Only
Plans Examinir
Zoning Official
ents:
YES lor NO
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
❑ Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
ABProjRegForm
Page 1 of 1
Texas Department of Licensing and Regulation
Architectural Barriers Project Registration Confirmation Page
Wednesday, June 18, 2008
EABPRJAB818609
PERSON FILING FORM
Name: Eddie Hare Email: ehare@traditionsdub.com Phone: 979-820-0149
RAS Number: 00000008
Project Name: Finish -out for the Liere Agency
Project Address: Liere Agency
1604 Copperfield Dr., Ste. 200
College Station, TX 77845 County: Brazos
TENANT Name: Phone: —
Tenant Address:
Contact Name: Phone: —
Contact Address:
BUILDING/FACILITY Name: Liere Agency
FACILITY Owner: The Liere Agency Phone: 979-220-3324
Owner Address: 1604 Copperfield Drive, Ste. 200, College Station, Tx 77845
Contact Name: Leslie Liere Phone: 979-220-3324
Contact Address:
DESIGN FIRM Name: L.B.I. Phone: 979-774A,600
Firm Address: P.O. Box 9356, College Station, Tx 77842-9356
Designer Name: Steve Hanson Email:
Type of License: Other License Number: n/a
PROJECT DESCRIPTION
Date Construction Documents Received By RAS: 06/18/2008
Start Date: 06/2008 Completion date: 1112008 Estimated Cost: $220,000.00
Type of Work: New Construction
Does this building(s) have more than one level? Yes
Are there any elevators, escalators, or platform lifts in this building? No
Type of Funds: This project is privately funded, on private land for private use.
State Lease No. :
Scope of Work: Finishout a new unoccupied shell building @ a certified facility.
Submit this AB Confirmation Page, Project Status Update Form and applicable fees to TDLR at P.O. Box 12157
Austin, Texas 78711 in accordance with the Texas Administrative Code Chapter 68.
Enter Another Project Print this Page
ToQof PagelTDLR Home PagelAB Home PagelAB Project RegistrelFeedback
http://www.license.state.tx.us/abprojectregistration/ABProjRegFormVerification.aspx?strR... 6/ 18/2008
Generated by COMcheck-Web Software
Envelope Compliance Certificate
20061ECC
Report Date: 06/18/08
Section 1: Project Information
Project Type: New Construction
Project Title :
Construction Site:
Owner/Agent:
Section 2: General Information
Building Location (for weather data):
College Station, Texas
Climate Zone:
2a
Heating Degree Days (base 65 degrees F):
1788
Cooling Degree Days (base 50 degrees F):
6851
Activity Tvoefs)
Floor Area
Office
4720
Section 3: Requirements Checklist
Envelope TBD7 No'lope assem6liesspecifOd
Climate -Specific Requirements:
Designer/Contractor:
Component Name/Description Gross Area Cavity Cont. Proposed Budget
or Perimeter R-Value R-Value U-Factor U-Factor
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements:
Air Leakage, Component Certification, and Vapor Retarder Requirements:
1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance
with the manufacturer's installation instructions.
LJ 2. Windows, doors, and skylights certified as meeting leakage requirements.
3. Component R-values & U-factors labeled as certified.
4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that
achieves the rated R-value without compressing the insulation.
5. No roof insulation is installed on a suspended ceiling with removable ceiling panels.
6. Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized
dampers.
Lj 7. Cargo doors and loading dock doors are weather sealed.
Lj 8. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air -tight assembly with a
0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material.
Note: Vapor retarder not required in this location.
Project Title: Report date: 06/18/08
Data filename: Page 1 of 8
eGenerated by COMcheck-Web Software
Is
Interior Lighting Compliance
m(j Certificate
2006 IECC
Report Date: 06/18/08
Section 1: Project Information
Project Type: New Construction
Project Title :
Construction Site: Owner/Agent: Designer/Contractor:
Section 2: General Information
Building Use Description by: Activity Type
Activity Type(s) Floor Area
Office 4720
Section 3: Requirements Checklist
Interior Lighting:
1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Watts Proposed Watts Complies
4720 4648 YES
Controls, Switching, and Wiring:
❑ 2. Independent controls for each space (switch/occupancy sensor).
Exceptions:
Areas designated as security or emergency areas that must be continuously illuminated.
Lighting in stairways or corridors that are elements of the means of egress.
El 3. Master switch at entry to hotel/motel guest room.
4. Individual dwelling units separately metered.
5. Each space provided with a manual control to provide uniform light reduction by at least 50%.
Exceptions:
Only one luminaire in space;
An occupant -sensing device controls the area;
The area is a corridor, storeroom, restroom, public lobby or sleeping unit.
Areas that use less than 0.6 Watts/sq.ft.
6. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft.
Exceptions:
Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security.
7. Photocell/astronomical time switch on exterior lights.
Exceptions:
Lighting intended for 24 hour use.
0 8. Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts).
Exceptions:
Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair.
Section 4: Compliance Statement
Project Title: Report date: 06/18/08
Data filename: Page 2 of 8
Compliance. Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2006 IECC
requirements in COMcheck-Web and to comply with the mandatory requirements in the equirements Checklist.
Name gnAura Dat
Project Title: Report date: 06/18/08
Data filename: Page 3 of 8
Generated by COMcheck-Web Software
Interior Lighting Application
Worksheet
2006 IECC
Report Date:
Section 1: Allowed Lighting Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts / ft2 (B x C)
Office 4720 1 4720
Total Allowed Watts = 4720
Section 2: Proposed Lighting Power Calculation
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
:Office (4720 sqA.)_
_
Linear Fluorescent 1: 2424: 24in. T8U 32W / Magnetic
2
10
64
640
Linear Fluorescent 2: 48in. T12 40W / Magnetic
1
12
40
480
Linear Fluorescent 3: up: 48 in. T8 25W (Super T8) / Magnetic
2
6
25
150
Linear Fluorescent 4: kitchen: 221n. T5 14W / Magnetic
1
5
14
70
Compact Fluorescent 1: Rec.: Quad 2-Pin 28W / Magnetic
1
53
28
1484
Compact Fluorescent 2: Track: Twin Tube 24/26/27W / Magnetic
4
18
96
1728
Compact Fluorescent 3: bath: Triple 4-Pin 32W / Magnetic
1
3
32
96
Total Proposed Watts =
4648
Section 3: Compliance Calculation
If the Total Allowed Watts minus the Total Proposed Watts is greater than or equal to zero, the building complies.
Total Allowed Watts = 4720
Total Proposed Watts = 4648
Project Compliance = 72
L i or, . _. _. x g aaie 7 $i ¢ v Y }h S! g2Gr k
Interior, fighting PASSES° Design 2io better than coded":'4,: ,° f
Project Title: Report date: 06/18/08
Data filename: Page 4 of 8
Generated by COMcheck-Web Software
Mechanical Compliance Certificate
2006 IECC
Report Date: 06/18/08
Section 1: Project Information
Project Type: New Construction
Project Title :
Construction Site:
Owner/Agent:
Section 2: General Information
Building Location (for weather data): College Station, Texas
Climate Zone: 2a
Heating Degree Days (base 65 degrees F): 1788
Cooling Degree Days (base 50 degrees F): 6851
Section 3: Mechanical Systems List
Designer/Contractor:
Quantity System Type & Description
3 HVAC System 1: Split System Heat Pump, Cooling Capacity <54 kBtu/h, Air -Cooled Condenser / Single Zone
2 HVAC System 2: Split System Heat Pump, Cooling Capacity >=54 - <65 kBtu/h, Air -Cooled Condenser / Single
Zone
1 Water Heater 1: Electric Storage Water Heater, Capacity: 50 gallons
Section 4: Requirements Checklist
Requirements Specific To: HVAC System 1 :
1. Equipment minimum efficiency: Heat Pump: 6.8 HSPF, 10.0 SEER
2. Heat pump thermostat required when supplemental electric resistance heat is installed
Requirements Specific To: HVAC System 2:
Ej 1. Equipment minimum efficiency: Heat Pump: 6.8 HSPF, 10.0 SEER
2. Heat pump thermostat required when supplemental electric resistance heat is installed
Requirements Specific To: Water Heater 1 :
EI 1. Hot water system sized per manufacturer's sizing guide
2. Electric Water Heater efficiency >= 0.86 EF, 267 SL, Btu/h (if > 12 kW)
3. First 8 ft of outlet piping is insulated
4. Hot water storage temperature adjustable down to 120 degrees F or lower
5. Heat traps provided on inlet and outlet of storage tanks
Generic Requirements: Must be met by all systems to which the requirement is applicable:
LI 1. Load calculations per 2001 ASHRAE Fundamentals
2. Plant equipment and system capacity no greater than needed to meet loads
Exception: Standby equipment automatically off when primary system is operating
Exception: Multiple units controlled to sequence operation as a function of load
i] 3. Minimum one temperature control device per system
El 4. Minimum one humidity control device per installed humidification/dehumidification system
Project Title: Report date: 06/18/08
Data filename: Page 5 of 8
0 5. Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool); 7-day clock, 2-hour occupant override, 10-hour backup
Exception: Continuously operating zones
Exception: 2 kW demand or less, submit calculations
6. Outside -air source for ventilation; system capable of reducing OSA to required minimum
Lj 7. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8
insulation between ducts and the building exterior when ducts are part of a building assembly
- Exception: Ducts located within equipment
- Exception: Ducts with interior and exterior temperature difference not exceeding 15 degrees F.
- Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2
inches w.g. pressure classification
8. Mechanical fasteners and sealants used to connect ducts and air distribution equipment
9. Ducts sealed -longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 181B tapes and mastics
❑ 10. Hot water pipe insulation: 1 in. for pipes —1.5 in. and 2 in. for pipes >1.5 in. Chilled water/refrigerant/brine pipe insulation: 1 in. for
pipes —1.5 in. and 1.5 in. for pipes >1.5 in. Steam pipe insulation: 1.5 in. for pipes —1.5 in. and 3 in. for pipes >1.5 in.
- Exception: Piping within HVAC equipment
- Exception: Fluid temperatures between 55 and 105 degrees F
- Exception: Fluid not heated or cooled
- Exception: Runouts <4 ft in length
11.Operation and maintenance manual provided to building owner
12. Piping, insulated to 112 in. if nominal diameter of pipe is <1.5 in.; Larger pipe insulated to 1 in. thickness
13. Lavatory faucet outlet temperatures in public restrooms limited to 110 degrees F (43 degrees C)
14. Balancing devices provided in accordance with IMC (2006) 603.17
15. Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings
- Exception: Gravity dampers acceptable in buildings <3 stories
- Exception: Gravity dampers acceptable in systems with outside or exhaust air flow rates less than 300 cfm where dampers are
interlocked with fan
o 16.Stair and elevator shaft vents are equipped with motorized dampers
Section 5: Compliance Statement
Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2006 IECC
requirements in CO check -Web and to comply with the mandatory requirements in the Requirements Checklist.
Name - Title ig ture Date
Project Title: Report date: 06/18/08
Data filename: Page 6 of 8
6 Generated by COMcheck-Web Software
�( Mechanical Requirements
Description
20061ECC
Report Date:
The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance
Certificate.
Requirements Specific To: HVAC System 1 :
1. The specified heating and/or cooling equipment is covered by the ASHRAE 90.1 Code and must meet the following minimum efficiency:
Heat Pump: 6.8 HSPF, 10.0 SEER
2. Heat pumps having supplementary electric resistance heat must have controls that, except during defrost, prevent supplementary heat
operation when the heat pump can meet the heating load.
Requirements Specific To: HVAC System 2:
1. The specified heating and/or cooling equipment is covered by the ASHRAE 90.1 Code and must meet the following minimum efficiency:
Heat Pump: 6.8 HSPF, 10.0 SEER
2. Heat pumps having supplementary electric resistance heat must have controls that, except during defrost, prevent supplementary heat
operation when the heat pump can meet the heating load.
Requirements Specific To: Water Heater 1 :
1. Service water heating system design loads for the purpose of sizing systems and equipment must be determined in accordance with
manufacturers' published sizing guidelines.
2. Service water heating equipment used solely for heating potable water, pool heaters, and hot water storage tanks must meet the
following miniumum efficiency: Electric Water Heater efficiency >= 0.86 EF, 267 SL, Btu/h (if > 12 kW)
3. Insulation must be provided for the first 8 ft of outlet piping for a constant temperature nonrecirculating storage system and for the inlet
pipe between the storage tank and a heat trap in a storage system.
4. Temperature controls must be provided that allow for storage temperature adjustment from 120 degrees F or lower to a maximum
temperature compatible with the intended use except when the manufacturer's installation instructions specify a higher minimum
thermostat setting to minimize condensation and resulting corrosion. Documentation of the installation instructions must be provided to
be exempted from this requirement.
5. Heat traps must be provided on inlet and outlet vertical pipe risers serving storage water heaters and storage tanks not having integral
heat traps and serving a nonrecirculating system. Heat traps must be installed as close as practical to the storage tank. Acceptable heat
traps are either a) a device specifically designed for the purpose or b) an arrangement of tubing that forms a loop of 360 degrees F,
or c) piping that from the point of connection to the water heater (inlet or outlet) includes a length of piping directed downwards before
connection to the vertical piping of the supply water or hot water distribution system.
Generic Requirements: Must be met by all systems to which the requirement is applicable:
1. Design heating and cooling loads for the building must be determined using procedures in the ASHRAE Handbook of Fundamentals or
an approved equivalent calculation procedure.
2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment providing
both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible, within
available equipment options.
- Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes. Standby equipment
must be automatically controlled to be off when the primary equipment and/or system is operating.
- Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are
provided with controls to sequence operation of the units as the load increases or decreases.
3. Each heating or cooling system serving a single zone must have its own temperature control device.
4. Each humidification system must have its own humidity control device.
5. The system or zone control must be a programmable thermostat or other automatic control meeting the following criteria: a) capable
of setting back temperature to 55 degrees F during heating and setting up to 85 degrees F during cooling, b) capable of automatically
setting back or shutting down systems during unoccupied hours using 7 different day schedules, c) have an accessible 2-hour occupant
override, d) have a battery back-up capable of maintaining programmed settings for at least 10 hours without power.
- Exception: A setback or shutoff control is not required on thermostats that control systems serving areas that operate continuously.
- Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Btu/h) or less.
Project Title: Report date: 06/18/08
Data filename: Page 7 of 8
.6. The system must supply outside ventilation air as required by Chapter 4 of the International Mechanical Code. If the ventilation system is
designed to supply outdoor -air quantities exceeding minimum required levels, the system must be capable of reducing outdoor -air flow to
the minimum required levels.
7. Air ducts must be insulated to the following levels: a) Supply and return air ducts for conditioned air located in unconditioned spaces
(spaces neither heated nor cooled) must be insulated with a minimum of R-5. Unconditioned spaces include attics, crawl spaces,
unheated basements, and unheated garages.b) Supply and return air ducts and plenums must be insulated to a minimum of R-8 when
located outside the building.c) When ducts are located within exterior components (e.g., floors or roofs), minimum R-8 insulation is
required only between the duct and the building exterior.
Exception: Duct insulation is not required on ducts located within equipment.
Exception: Duct insulation Is not required when the design temperature difference between the interior and exterior of the duct or
plenum does not exceed 15 degrees F.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2
inches w.g, pressure classification.
8. Mechanical fasteners and seals, mastics, or gaskets must be used when connecting ducts to fans and other air distribution equipment,
including multiple -zone terminal units.
9. All joints, longitudinal and transverse seams, and connections in ductwork must be securely sealed using weldments; mechanical
fasteners with seals, gaskets, or mastics; mesh and mastic sealing systems; or tapes. Tapes and mastics must be listed and labeled in
accordance with UL 181A and shall be marked '181A-P' for pressure sensitive tape,'181A-M' for mastic or'181A-H' for heat -sensitive
tape. Tapes and mastics used to seal flexible air ductsand flexible air connectors shall comply with UL 181 B and shall be marked
'181 B-FX' for pressure -sensitive tape oe181 B-M' for mastic. Unlisted duct tape is not permitted as a sealant on any metal ducts.
10. All pipes serving space -conditioning systems must be insulated as follows: Hot water piping for heating systems: 1 in. for pipes 1
1/2-in. nominal diameter, 2 in. for pipes >1 1/2-in. nominal diameter. Chilled water, refrigerant, and brine piping systems: 1 in. insulation
for pipes 1 1/2-in. nominal diameter, 1 1/2 in. insulation for pipes >1 1/2-in. nominal diameter. Steam piping: 1 1/2 in. insulation for
pipes 1 1/2-in. nominal diameter, 3 in. insulation for pipes >1 1/2-in. nominal diameter.
- Exception: Pipe insulation is not required for factory -installed piping within HVAC equipment.
- Exception: Pipe insulation is not required for piping that conveys fluids having a design operating temperature range between 55
degrees F and 105 degrees F.
- Exception: Pipe insulation is not required for piping that conveys fluids that have not been heated or cooled through the use of fossil
fuels or electric power.
- Exception: Pipe insulation is not required for runout piping not exceeding 4 ft in length and 1 in. in diameter between the control valve
and HVAC coil.
11. Operation and maintenance documentation must be provided to the owner that includes at least the following information:a) equipment
capacity (input and output) and required maintenance actionsb) equipment operation and maintenance manualsc) HVAC system
control maintenance and calibration information, including wiring diagrams, schematics, and control sequence descriptions; desired
or field -determined set points must be permanently recorded on control drawings, at control devices, or, for digital control systems, in
programming commentsd) complete narrative of how each system is intended to operate.
12. Service hot water piping, where required, must be insulated to 1/2 in. if pipe less than 1.5 in. nominal diameter. Larger pipe must be
insulated to 1 in.. Pipe insulation will have a conductivity of less than 0.28 Btu.in/(h-ft2-degrees F).
13. Temperature controlling means must be provided to limit the maximum temperature of water delivered from lavatory faucets in public
facility restrooms to 110 degrees F.
14. Replaced with
15. Outdoor air supply and exhaust systems must have motorized dampers that automatically shut when the systems or spaces served
are not in use. Dampers must be capable of automatically shutting off during preoccupancy building warm-up, cool -down, and setback,
except when ventilation reduces energy costs (e.g., night purge) or when ventilation must be supplied to meet code requirements. Both
outdoor air supply and exhaust air dampers must have a maximum leakage rate of 3 cfm/ft2 at 1.0 in w.g. when tested in accordance
with AMCA Standard 500.
- Exception: Gravity (non -motorized) dampers are acceptable in buildings less than three stories in height.
- Exception: Systems with a design outside air intake or exhaust capacity of 300 cfm (140 Us) or less that are equipped with motor
operated dampers that open and close when the unit is energized and de -energized, respectively.
16. Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically closed during normal building
operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and exhaust hoods,
vents, and ventilators must be equipped with motorized dampers that will automatically shut when the spaces served are not in use
- Exception: Gravity (non -motorized) dampers are acceptable in buildings less than three stories in height above grade
- Exception: Ventilation systems serving unconditioned spaces.
Project Title: Report date: 06/18/08
Data filename: Page 8 of 8