Loading...
HomeMy WebLinkAboutRES2008-01682, 08-1683WF1043672 / 061 City of College Station s- • PAGE 1 REQ. DATE: 06/05/08 06/05/08 15:55:12 LOCATION: 15552 CREEK MEADOW BLVD N LOC ID: 212202 REQUESTOR: LONESTAR CONSTRUCTION ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 06/05/08 SCHED COMPLETION: 06/05/08 ******************************************************************************** JOB ORDER RESULT COM4ENTS PREPARED 3/03/09, 12:08:53 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/03/09 ------------------------------------------------------------------------------------------------ ADDRESS . : 15552 CREEK MEADOW BLVD N SUBDIV: CONTRACTOR LONESTAR CONSTRUCTION PHONE (979) 680-0551 OWNER . . PHONE PARCEL . . 211650-1204-0030 APPL NUMBER: 08-00001682 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/16/08 BI BLDG, FOUNDATION -SLAB TIME: 17:00 6/17/08 CA June 16, 2008 9:10:59 AM acarter. tuesday morning please B100 02 6/18/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00 6/18/08 AP June 17, 2008 4:01:03 PM acarter. Wednesday Afternoon please B120 01 6/26/08 BB BLDG, FRAMING -PARTIAL TIME: 17:00 6/26/08 CA June 26, 2008 11:05:57 AM glsouth. APA FRAME Doesn't need APA framing. Plans call for Simpson panels, which are installed. B115 01 7/21/08 OC BLDG, FRAMING TIME: 17:00 7/21/08 AP July 21, 2008 10:51:34 AM acarter. B130 01 7/23/08 OC BLDG, INSULATION TIME: 17:00 7/23/08 AP July 22, 2008 1:26:57 PM acarter. Wednesday afternoon please. B125 01 2/27/09 BI BLDG, FINAL TIME: 17:00 2/27/09 CA February 26, 2009 8:25:19 AM kgreen. FRI AM B125 02 3/02/09 BB BLDG, FINAL TIME: 17:00 3/02/09 DP March 2, 2009 8:06:51 AM glsouth. / G Exhaust fan, in utility room, needs to be duct out attic. B125 03 3/03/09 BI BLDG, FINAL TIME: 17:00 March 3, 2009 9:05:06 AM ccourt. -------------------------------------- COMMENTS AND NOTES ----------------- - Jun 18 08 02:59p Toni Medina (972) 875-1398 p.2 gineering, LLC 401 S. CLAY STREET. ENNIS. TX 75119 June 18, 2008 City of College Station Attn: Chris College Station, TX Subject: Trinity Custom Homes, Regarding 15550 & 15552 Creek Meadow Blvd, College Station. Our authorized inspector has approved the slab and we have reviewed pictures from the builder to confirm the placement of the plumbing meets our specifications. Our specification "Plumbing may cross beams but not be placed in beams" is intended to mean not in the beam running parallel. Sincerely e., �, .y� a-..— A.G. (Tony) Medina Registered Professional Engineer PHONE: 972.878.EN(;R (36471 - FAX: 972.875.1398 - E-MAIL: inroCrbWoundatlons.com Jun 17 08 01:58p Paul Williams Land Survey 9797797672 p.3 Lot 6 Lot 5 R 375.00' D- f0?5 55' 1-68.28' T=34.2J' — — — LC=6B.18' R11 " Iron CB=N 8rO454' E Fnd. (Cal! and Actual) 20' P.U.E. 80281248 _ -I ----------------- f-- Q U � V Scale: I' - 20' p v � o N 3 3 Lot 4 a� 0 � 2 r I 10' X 40' P.U.E. 1r- 8028/248 I I _J r---- 8 8thock Lot 3 i f J.6 I 14.2' I I � I 4.5' I I 4.0' iq 12;1 Ary J, 1 8.0' I h I Forms j I � 1 -1 I I I �-1 52' I I 1 7 , 19.4' 11.7' 7,0, L_ 8028 248 N. N. Lot 7 �, i Rod Fnd. R I J.00" 0=f0'3076' L-46.40' 1/1' Iron T 2J,26' Rod Fnd LC 46.3J' J/2" Gan CB-S ArI6:28" W Rod Fnd (Call and Actual) 15552 Creek Meadow Boulevard North Form Survey Prepared for. David Adome Lot 2 Being al/ of Lot 3 (INREE), Block 4 (FOUR), CREEK MEADOWS SUBOMS/ON, SEC77ON 18, PHASE 1, an addition to the City of College Station, Brazos County, Texas, according to the plot recorded in Volume 8028 Page 248 of the Official Records of Brazos County, Texas. 4 Paul Williams Registered Professional Land Surveyor No. 574J do hereby certify that this plot represents the results of o survey performed on the ground, under my supervision on June 4, 2008, and is true and correct to the best of my knowledge. / further certify that no improvements on this property encroach on adjacent property, nor do any improvements on adjacent property encroach on to this property, except as shown. PAUL I WILLIAMS LAND SURVEY/NG U U. 307 South Main Street, Ste. 206 Bryan, iX 77803 979-779-7670 Fax 979-779-7672 pwlandeurveyi n gOea rthlink.net Notes: North orientation is based on rotating the north line to plat calls in 80281248. This survey was prepared without the benefit of a title commitment. k:/p wft oldients/2008/8190. dwg APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CI-7 OF COLLEGE STATicw (979) 764-3570 (979) 764-3496 FAX I'(nrsxine � I)�+r(uprun+r Gruin WWW.csTX.GOV DATE: (Y • 1 O&CC REG APPLICATION # Q TEMP POLE # O �+• ADDRESS/L ATION: 1555 c- UAL 1 { FCclAcu-) 1 V . LOT BLOCK SUBDIVISIONJe--L ff)EGdW 6 -XLb `/SEC/PHI ON�. 1 BUSINESS/OWNER N M : LoNe_t)yar QJ► r4 uOR, (�.4 1 1 — PHONE'q�`1-4 1-11 O CONTRACTOR/HOMEOWNER'�L DOA `Fk �ame. PHONE. hol -41z` ' 11 l rl CONTACT PERSON FOR REVIEW COMMENTS: PHONE: ' FAx: CV1q-k6w-C7551 EMAIL: (.� adome_a D'a . COM ELECTRIIICIAN:j 1 ��' C l� PLUMBER: ek.), cy „(� HVAC: C+A't � GOOD CENTS (Residential only): f f C ACCESSORY/STORAGE MOVING RE -ROOF ' ADDITION NEW CONSTRUCTION* SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEURENOVATION" TENT RETAINING WALL ' (�� -, DESCRIPTION OF WORK: Neu w `-A bT` uck nw PROPOSED USE: Sl"'oy Lry1y STRUCTURE USEA?t-' JId e 1tCe. HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PRO ECT REGISTRATION NO. EASPRJ�C� (� VALUATION: $ 10�9 ,C - TOTAL AREA: 1HEATED AREA: 1500 (Cost of Labor and Materials) 2 V` PUBLIC SEWER NUMBER OF BEDROOMS: J SEPTIC/TREATMENT SYSTEM SEWER TAP: WATER TAP: ' OTHER TAP: ****�RTEMP POLE GARAGE TYPE: 1� NUMBER OF BATHROOMS: 2_.5 �( U `"1' INTERIOR WALL TYPE: 3 SIZE � t' bo W EXTERIOR WALL TYPE: s1 FOUNDATION TYPE: SIZE Zv ROOF TYPE: SINGLE DOUBLE is[ TRIPLE ATTACHE D,ETACHED CARPOR SIGNATURE OF APPLICANT: ► ' `If proposed work involves new commercial constFuctiolrerl6cade impr ments/renov commercial property, building elevations are required. ............................................................ � � _ �V U � Official use Only 6" f &tf#L4 51 J Plans Examiner -- Ga't4AA w 1H Zoning Official to an existing Comments: ES r NO Energy Code Compliance Information % Glazing of exterior walls 3 ✓ Insulation R value of exterior wallsi- Insulation R value of ceiling I (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic)- 30 ✓ Glazing SHGC (Solar Heat Gain Coefficient) .2.�i / Glazing U-Factor O. ='� R value of ductwork - (, A/C SEER Rating 13 ✓ Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. 68.225' 46.33' 15552 Creek Meadows Blvd PLOT PLAN LOT 3 BLK 4 CREEK MEADOWS COLLEGE STATION BRAZOS CO. TEXAS Lonestar Construction PLAN # 1500 Creek Meadows Lot 3 Blk 4 15552 Creek Meadow Blvd College Station, Tx. 77845 1 1 14' 2" 4' 6" 8' 0" 9' 8" 3•u^. s�o° ro-x S6. I I I = I � I I MAST4R SU TEI SLOPE CLG 8'- 10' I o _ 2' 8" 4' 0" 3' 0" o 0 8' CLG _ 8' 67 ' 1/4" 2' �•o-xso^ J• a x ,D g n44- FAMILY BREAKFAST 8' CLG 9' 6e 10' CLG a T 8 1' Q I KITCH I v 8' CLG ' BDRM 2 ®° SLOPE CLE 8'- 9' q 11' I 1 /4" - - fV 511101, 3' 8" IT 8 3/4" 6' 6" 310' I 1' 7 1 /4" 6' 3 1!2" 3' 7 1 /4" 5' 10" I I w I t` O Tg" tV v - e" " ENTRY 10' CLG = ATTIC Ls " ? STAIR II � ® a GARAGE ------------ - - FOOTAGE T 5 I/4 4' 2 3/4" LIVING 1500 — Tn� Ri - s BD�-LM 3 gafdA5 I I i COPYRIGHT 2007 I I 19' 6" 3.0' 5' ^ I 36' 4i{" 04t*w esON IAo rs fvo-A Ai�ll t eI1- a�.1 N. I �*-Jljlsl 67CLON 1 1 3T , 5' 0' 3' V 5' 0' MASTER SUITE / SLO�E CLG 8' - 10' 1 I I I I 8' CLG A0� I 1 Y Q ,50^ _________�_ l'01a 5'0' 3'01a 5'0' i BREA14ST F\AMILY / 8' CLG CLG------------------- " a i BDRM ® P SL ECLE8'-9' / I �\ W2'K" W. Dors^ � W • `� D n¢ " ENTRY srR�IL - ----- I O' CLGG GARAGE / au 8'CLG I�OI� ---------------------------------------- 1 131) SLOPE+CLG8' 10' di 01, I/ 3'0'a50- COPYRIGHT 2007 ELECTRICAL SYMBOL ceiling fan spotlights 1 fluorescent fixture vanity bar light Q wall mount I Q fan light outlet outlet gfi smoke detector s switch $ GRANULAR FILL #4 BARS @ 12" O.C. BRICKLEDGE; SEE GENERA. GARAGE 2- #5 BARS BOTH WAYS 2 LAYERS - MASONRY OMIT FOR 2- #5 BARS 2- #5 BARS NOTE FINISH SLAB DROP TOP 1 LAYER - METAL F.P. SIDING WALL TOP FINISH SLAB TOP TYPICAL L OPTIONAL r�N NONE - VENTLESS F.P. I- , �'' O Q I I I la$ I I-1 11=1 I I 11 o II-" _ Il I �11 #3 SUPPORTS �- I- I-1 I k ,, :f=.,• : ' I h ���-li = -- L' o �I I I -III I I- W N Qm-II a I 1=1J= I -I J ° ° II- °" a z -III I -II III_ #3 SUPPORTS @ so" O.C. - II III -I =III - I -II" 11�1I ° III, -III IL- J W Z) 2 `� _ ° ° a Z III I=III' � Y °Q a: - J LL JII II-' @ 60" O.C. TYPICAL -III III- #3 SUPPORTS II ° ° IIL- � } z ° II°n 'I I I ° ° _ �IIII 'I III TYPICAL 3- #5 BARS 3- #5 BARS BOTTOM. CONTINUOUS @ 60 O.C. TYPICAL CONTINUOUS _j m �- SEE PLAN FOR z g FIREPLACE W � p Q _ o ¢ U a 2 o a w BOTTOM. TYPICAL W VAPOR BARRIER 3- #5 BARS W VAPOR BARRIER cn DIMENSION Q ¢ a W w a TYPICAL TYPICAL BOTTOM. TYPICAL a o N x TYPICAL DETAIL "E" rn T m DETAIL "A" DETAIL "B" DETAIL "C'I BAR REINFORCING TO START 2— #6 BARS MAY BE MINIMUM 5" FROM EDGE I SUBSTITUTED BRICK LEDGE 2_ #5 BARS WHEN APPLICABLE 2- FOR 3— #5 BARS TOP FINISH SLAB I rTN Z a ° CORNER BARS BOTTOM INSIDE ONLY APPROX. 45 DEGREE ANGLE BRICKLEDGE o #4 BARS ° #3 HAIRPIN BAR CENTERED =1 I III=11�1-1 II I I I I' ` WHEN Q ¢ @ 12" O.C. 6a a , I AT CORNER 12" FROM EDGE APPLICABLE o 5 BOTH WAYS a _ ° ° ° — _—_ — I ° III=111- 11= ° L=1 I� 3- #5 BARS I I I I 2- #5 BARS TOP I #3 SUPPORTS ° I d °I W @ 60" O.C. a a d° a BOTTOM rTN IL—f �I UNDISTURBED i =11I— 11111� SOIL °zo N — _ _ •-1 — ° , �i i ° l I -- ° °a ° a 2- #4 BARS VERTICALLY SPACED 12" O.C. AS -1 I I 1�11=L-1�J-III=11 III- III—III—IiI—III=f 11=1�1=11 Imo' CORNER BARS ° iz" @ _ a a III= REQUIRED PER BEAM DEPTH AS REQUIRED -III,�III I I TOP &BOTTOM 1 TOP VIEW PER BEAM DETAIL AT CONTRACTOR'S —r I SEE PLAN _ OPTION BEAM WIDTH MAYBE 3- #5 BARS�2 3'-0° MAX. w BOTTOM. TYPICAL _ T�N NOTE: IT IS IMPORTANT TO USE THIS DETAIL WHEN EXTENDED TO DETAIL 'IF" ° � a I 1 - _ -_ _ _ - THERE IS A 4' OR LESS SLOPE IN THE FOUNDATION FOOT PRINT AREA. TO INSURE THAT SETTLEMENT FORM. REINFORCE I I #3 SUPPORTS WITH 2-#5 ° pf @ so" O.C. I DOES NOT OCCUR, THE BOTTOM OF THE BARS BOTTOM ° _ -' SIDE VIEW PERIMETER BEAM MUST PENETRATE UNDISTURBED SOIL A MIN. OF 12" TYPICAL CORNER STIFFNER BAR CONCRETE SLAB CORNER DEEPEN BEAM (THIS REBAR PREVENTS CONCRETE BARS DETAIL CORNER BREAKAGE WHEN BRICK LAYER DETAIL DOES NOT USE POLY UNDER BRICK) (CORNER BARS TO BE SAME SIZE OF BEAM BARS) NOTES: co JK\�\zttl = o N 1. SLAB THICKNESS, BEAM SIZES, AND ,r S* • `�'��ti It N DIAGONAL: A REINFORCEMENT REQUIREMENTS SHALL BE AS ,��P' :z: /`�tir1 o o 73'-0 3/16" SPECIFIED BELOW. :o:� 0 %1 z ~ cn 2. 4" OF CUSHION (LEVELING) SAND UNDER:�:0) w: < a a LOD \ CONCRETE SLAB IS RECOMMENDED TO ACHI .�:� : oz� ¢ 3 a LEVEL SURFACE. I I 1 tX001y Q. r �3. BOTTOMS OF ALL EXTERIOR BEAMS SHALL �,�co W- INCHES I A OL 02),IL, ORilt\\\� ~ ° 0 I COMPACTED12 SELECT FILNIMUM 1 I 1 (IDLIESS THAN 1STURBED I I I ��`�~ 0 a I SHALL BE PLACED IN ACCORDANCE WITH ACCEPTED II I I I I I STANDARDS SUCH AS THE STANDARD PROCTOR - - - DENSITY IN ACCORDANCE WITH ASTM 698. THIS IS NOT - - - - U) r I r r II II I APPLICABLE WHEN USING PIERS. o LU I I I l l I F 4. ALL FORMS SHALL BE STRAIGHT AND WELL U r O w I I I I I I #3 BARS @ SUPPORTED A 5. ALL CONCRETE SHALL HAVE A DAY MINIMUM rr W N � O I 00 I I I I I 12"O.C.E.W. 28 J I I I I I I COMPRESSIVE STRENGTH OF 3000 P.S.I. AND BE O Z r� F- 0 rn � w m z I L I J L J COMPLIANT WITH LATEST EDITION OF AC 318. LL O = � X rn O _ - - - - r - _ _ _ _ - - - - - 6. CONCRETE SHALL NOT BE PLACED WITH SLUMP f r Z - I- w p U I I GREATER THAN 5 INCHES. WATER SHALL NOT BE I - w z w LU Q O~ JO Q O 1 I I I I I I I ADDED TO CONCRETE AT JOB SITE. I I I I I I I _O � ~ a H Q w U�� I N 7. ALL CONCRETE SHALL BE PROPERLY I I I I I I I (n C7 Q 0 � 00 Y m I °' I I I I I CONSOLIDATED ESPECIALLY AT ALL CORNERS. LU Z 5 z'cn w 1 I I I I 11 8. PROVIDE A 6 MIL POLYETHYLENE MOISTURE pQ U 2 w � ZO I L----- 11 I I I I I RETARDER BENEATH SLAB AREA. - JL - - ---- JL-------I--- - - - - -J UJI N w Q O U F= - - 9. ALL BEAM REINFORCING SHALL EXTEND TO WITHIN -------- --------I C �- - N � r----- r----- I ,� 12 OF EXTERIOR FORMS. O V Z U m � (n T I 10. ALL FOUNDATION REQUIREMENTS: ERENOFORCNGSHALL RCING TO BE OBE ¢U Z w ~O = I N I I I I I I 111. BEAM TIED AND I ZO O w r� I I I I I I I A 1. THICKNESS T= 5° SUPPORTED EVERY 4'-0" MINIMUM, STARTING A MAX. U J JO (o I I I I II I I 2. SLAB STEEL - #3 BARS @ 12°O.C.E.W. OF 12" FROM END OF FORM BOARD. U ao U 9 4' 1 u t\ 17' 8 u 9 4 3. BEAM WIDTH W = 1 Q" 12. ALL #3 BARS SHALL BE 40 GRADE STEEL AND ALL LJ L \\_____ L___-_--J O L___--___ ------- #4 OR LARGER BARS SHALL BE ASTM A-615 GRADE 60. -- ---I 4. BEAM DEPTH D = 32" r----- 1 r-------� r--------1 13. LAP ALL BAR REINFORCING 30 DIAMETERS. ~ I I I I I I I I 5. BEAM STEEL - TOP: 245 14. PROVIDE CHAIRS OR OTHER SUITABLE SUPPORTS w T w T- u. O `� DROP i BOTTOM: 345 OR 246 FOR SLAB REINFORCING. � O Oco I I I I I I I I 15. PLUMBING MAY CROSS BEAMS BUT NOT BE 1 1 I I I I 6. AREA = 1898 SQ. FT. Lo 1 I I i I 7. EST. CONCRETE = 80 YDS. PLACED IN BEAMS. I I I I \ I I 1 16. GARAGE AND PORCH SLABS SHALL BE SAME AS o LL ICC L-_____ L_--___J L______-_J L_______J THE HOUSE SLAB. U F----- __J 1 F--------1 F------- �\� I-'-------1 17. ALL REINFORCING TO HAVE A MINIMUM OF 1 I z IJj I 1 CONCRETE COVERAGE. I I DROP 1 1 I 0 0 0 I - II II II w l I 18. DRAINAGE DRAINAGE DRAINAGE: THE FINAL 0 b N O Uo II w OTOUTIOSccm" n GRADE AROUND HE FOUNDATION HALL BE 8" II II co O LOETPO° ATIO I I I I W FOUNDATION AND SLOPE ¢ z L_-___ --z _J L- _-J L________J L__ J AWAY FROM THE FOUNDATION AMINIMUM OF6"IN� O _ r----- I -1 F- r---- ----i F-- ----� l6-0". II A I II I a � s U¢ lw- > w O I I I I I I I I I I I o I I I 19. TO INSURE PROPER DRAINAGE AS STATED ABOVE, 0 cn 0 Im Q C THE ELEVATION OF THE TOP OF SLAB SHALL BE A I 0)I I I I I I MINIMUM OF 12 INCHES ABOVE THE HIGHEST NATURAL J E I I F _ _ J L _ _ _ _ _ _ _ J GRADE ELEVATION AT THE PERIMETER OF THE SLAB E a L _ _ _ _ _ J L _ \ 20. ALL GRADE BEAMS AND SLAB AREA SHALL BE w °' (o0 0 FREE OF ANY STANDING WATER AT THE TIME OF L- , co , o °' CONCRETE PLACEMENT. A to r- � ^ }, E N co coma, -c A 21. AT OWNERS / CONTRACTORS OPTION, BRICK g n N @a MAY BE INCLUDED OR OMITTED AT EXTERIOR U z rn o E 36-4 DOOR OPENINGS. 0)LEDGE c: uj z ui m w 22. THIS PLAN IS FOR FOUNDATION ONLY WHICH W F w SPECIFIES BEAM AND SLAB STEEL. SET FORMS BY Q 3 E FLOOR PLAN. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning 6 Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: O le BUILDING ADDRESS: Ss� C�t.¢elt av /? I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated O II. Framing: Floor, Wall, Ceiling and Roof Requirements K A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an 0. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. 10WOK OK M CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NjAIr 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location 0 (*f/q" CITY OF COLLEGE STATION Planning cr Development ServiaJ PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NA K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NlLkPIV A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) r B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 Nq K Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." 4AO�._� PffATsIS EXAMINER DATE MAR-06-2009 14:20 From:9797744736 To:7643496 Paee:2,2 dOV, 1 (0 �0) �J TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT Property Qwner: LONE STAR. CONSTRUCTION, 15652 CREEK MEADOW. BLVD. 1898 Percentage of 'de`$, to be applied at this location: Iyp2 of Treatment: Full Partial XX Vertical XXM HorizontallPerlmeter Beam„ XX • 1 � • . e =zi 11H • ;111'�I i R ► i•• �I�90m mo, A LABEL FOR ANY OTHER PESTICIDF. RFCOM$NDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) INCLUDING AREA COVERED, TIME PFRIOO OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE- TREAT FOR TEPmTE INFESTATIONS OR RFPAIR DAMAGE CAUSED SY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT COULD DEVELOP AS A RESULT OF THE OWNFR'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. Charges for pre -treat: NOTES: Annual re-newal: f0, WV AMN I ff W 11,W $328.73 $120.00 32129 PT Cm or TWOPOm SPCB 1110 611412008 nt" PT WO MAR-09-2009 16:31 From:9797744736 To:7643496 Pase:1,'2 Ace Pest Control T.P.C.L.# 7120 PT PO BOX 4474 BRYAN TX, 77805 (979) 823-7777 urfice (979) 774-4736 fax Fax Cover Sheet � To: Ef� � 1 O S �t C--�,- nwnber of pages including cover page L Phone: Fax: i(,.4-` -:�¢9 (a From: ACE PEST CONTROL Date: 3 (,) 1 ° C� Remarks: lcwv c srfr� a v 5 oi 155 S Z.r Ca-e:rs k,-- rn&f-p64J &I- y.D Thanks 4s� Ace Pest Control MAR-09-2009 16:31 From:9797744736 To:7643496 Pase:2,2 Zq �m Ace Pest Control PO Box 4474 Bryan TX 77805 Bill To Service Date LONE STAR CONSTRUCTION, LLC. 2602 WINGATE CT. COLLEGE STATION, TX_ 77845 Type Of Service STATEMENT Date: March 9, 2009 979-823-7777 TPCL 712OPT Professional Services At An Affordable Price 6/14/20U8 15552 CREEK MEADOW BLVD. SLAB PRETREAT .06 BIFENIHIiIN SOLUTION 90 GALS 1.30 Days 31-60 days 61-90 Days Current Date 2120109 Amount Due Amount enclosed LONE STAR CONSTRUCTION, LLC. All bills DUE on or before the 101h of the month following date of service. Service Charge of 1 1/2 % per month (18°% per year) Added to Past Dues Accounts. THIS PORTION IS FOR YOUR RECORDS. YOUR CHECK IS YOUR RECIEPT Please return this portion with payment Remittance thank you for your business Amount Due AddieSS: ACE PEST CONTROL - TPCL#7120PT P.O. BOX 4474 BRYAN, TX. 77605 ' BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00001682 Date 6/05/08 Application pin number . . . 904680 Property Address . . . . . . 15552 CREEK MEADOW BLVD N Property ID: - - R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 106000 Owner Contractor ------------------------ ------------------------ LONESTAR CONSTRUCTION P.O. BOX 9606 COLLEGE STATION TX 77842 (979) 680-0551 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . A/C SEER RATING 13.00 CEILING 1 R VAL. (FLAT) 30.00 CEILING 2 R VAL-NO ATTIC 30.00 DUCT R VALUE 6.00 EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT . GLAZING 13.00 GLAZING U-FACTOR .54 HEATED'AREA 1500.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 3.00 EXTERIOR WALL INSUL R VAL 13.00 GLAZING SHGC .29 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 4410.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 578070 Permit Fee . . . . 478.00 Plan Check Fee .00 Issue Date . . . . 6/05/08 Valuation . . . . 106000 Expiration Date 12/02/08 -------------------------------------------- BUILDING DF/PT REPRESENTATIVE: ----- - �� ---------- APPLICANTA BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Page 2 Application Number . . . . . 08-00001682 Date 6/05/08 Application pin number . . . 904680 Qty Unit Charge Per Extension BASE FEE 460.00 6.00 3.0000 THOU BLDG, VAL 100001-500000 18.00 Special Notes and Comments -Engineered Foundation -Narrow Wall Bracing Fully Sheathed with Interior Anchors and Bracing at Back Door Area and Simpson Panels at each side of garage entry. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of A A w . f . ------------------------------------------- +------�� �- ��.�.------------ BUILDING D T REPRE ENTATIVE : {�J. Q✓a"� APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00001682 Date 6/05/08 Application pin number . . . 904680 ---------------------------------------------------------------------------- Special Notes and Comments Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 15% the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 * THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN 2006 IRC *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL BE PERFORMED PRIOR TO FRAMING INSPECTION. *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE --- -- • -------------------------------------------- BUILDING DE /?T REPR SE APPLICANT:'\ I BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00001682 Application pin number . . . 904680 Page 4 Date 6/05/08 Special Notes and Comments *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 150-o of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WLHIN 24" OF DOORS IN ----------------------------------------------------------- EUILDING DPT REtRES�E TA.T^IVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00001682 Date 6/05/08 Application pin number . . . 904680 ---------------------------------------------------------------------------- Special Notes and Comments ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK *GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. *PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY BEING ELEVATED A MINIMUM OF 18" ABOVE FLOOR LEVEL. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 478.00 478.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1228.00 1228.00 .00 .00 r BUILDING D5PT REPRESENTA APPLICANT: • + --- -- - - - - - - - TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00001683 Date 6/05/08 Application pin number . . . 035420 Property Address . . . . . . 15552 CREEK MEADOW BLVD N Property ID: - - R #. Application type description TEMP POLE Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ LONESTAR CONSTRUCTION P.O. BOX 9606 COLLEGE STATION TX 77842 (979) 680-0551 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 578088 Permit Fee . . . . 20.00 Issue Date . . . . 6/05/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 20.00 20.00 .00 .00 Grand Total 20.00 20.00 .00 .00 ------------------------------------- - - - - -- ------ - ---•- ------------- BUILDING DE T REPRESENTATIVE: APPLICANT: -1a. (