Date: 11/19/2009
Inspection Comments for Finals
Permit Year: 8 Permit Number: 1673
Address: 5003 AUGUSTA CIR
Insp.
Inspection Type Code
Description
scats
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings up. Slab ground installed
B115
BLDG, FRAMING
IC
Fireblock fireplace in living room by insulation.
E150
ELEC, FINAL
IC
Need spark rings in livingroom. eed G protection for
E150
ELEC, FINAL
IC
outdoor-rVZge. Need or
E150
ELEC, FINAL
eed arc fault protection for outdoor light
E150
ELEC, FINAL
IC
switches in master. Need to install outdoor flood lights to
E150
ELEC, FINAL
IC
check operation. Need to install light above master tub.
P105
PLBG, TOP OUT
IC
Partail, vent only. Install stud repair shoes on load baring
P105
PLBG, TOP OUT
IC
walls, by framing.
Page 1
PREPARED 11/19/09, 12:01:38
INSPECTION TICKET PAGE 1
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 11/19/09
------------------------------------------------------------------------------------------------
ADDRESS
. : 5003 AUGUSTA CIR
SUBDIV: PEBBLE CREEK
CONTRACTOR S C STOKES CONSTRUCTION, INC PHONE (979) 690-6626
OWNER
SCRUGGS, SHAY W &
RONNA S PHONE
PARCEL
497900-0018-0220
APPL NUMBER: 08-00001673 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
7/31/08 BB
BLDG, FOUNDATION -SLAB TIME: 17:00
7/31/08 AP
July 30, 2008 8:03:23 AM acarter.
thursday afternoon please
Strings up. Slab ground installed
B115 01
11/06/08 BB
BLDG, FRAMING TIME: 17:00
11/06/08 AE
November 6, 2008 8:05:21 AM ccourt.
Fireblock fireplace in living room by insulation.
B130 01
11/21/08 OC
BLDG, INSULATION TIME: 17:00
11/21/08 AP
November 20, 2008 9:46:03 AM ccourt.
Friday AM /
B125 01 11/19/09 BI BLDG, FINAL TIME: 17:00
/L M -cq M j?j+
November 19, 2009 10:57:39 AM ccourt
----------------------------------- CONTINUED ONTO NEXT PAGE--------
'T-&M P C. D,
Lpi
i ^j A4 c AN COM 10k, U NC)�eFZ • �:
w `�°f �-- V�-I U�- �� e�z . � �2 io hoc ►�ov� `t-�-�� �sa-c2
QOM
C�
P
NOV-20-2009 11:50 From:9797744736
Ace Pest Control
PO Box 4474
Bryan TX 77805
Bill To
To:7643496 Pa9e:2/3
i
j
STATEMENT
I
Dole: November 20, 2009
979-823-7777
TPCL 712OPT
Professional Services At An Affordable Price
/1 All bills DUE on or before the 1001 Of the month
foliowing date of service. Service Charge of
] 'h %, per month (18% per year)
a Added to Past Dues Accounts. THIS PORTION IS
e FOR YOUR RECORDS. YOUR CHECK IS YOUR
RECIEPT
I
i
I '
Service Type Or Service Square i
Date _ ... - - —. _ _._ ........... ..... ft I
.. .....................
7/22/2008 5003AUGUSTA SLABPRETREAt - 675� _.�.__._..�__._.. .
.06% Bifenthrin Solution 275 gals.
SC STOKES CONSTRUCTION
5200 WHISTLING STRAITS CT.
COLLEGE STATION, TX. 77845
1-30 Days
Current
31-60 days
61-90 Days
.................. ........
I
I
I
Over 90 Days
I
Please relurn this portion with payment
Remittance
Date
Amount Due
Amount enclosed
SC STOKES CONSTRUCTION
Thank you for your business
Arnount Due
_ I
ACE PEST CONTROL! - TPCL#7120PT
P.Q. BOX 4474
BUILDING PERMIT
CITY,OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)76.4-3570 FAX: (979)764-3496
http:'//bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00001673 Date 6/10/08
Application pin number . . . 728020
Property Address . . . . . . 5003 AUGUSTA CIR
Property ID: 497900-0018-0220
R #: R93888
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . PEBBLE CREEK
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 1000000
Owner Contractor
------------------------ ------------------------
SCRUGGS, SHAY W & RONNA S S C STOKES CONSTRUCTION, INC
810 ROYAL ADELADE DR 5200 WHISTLING STRAITS CT
COLLEGE STATION TX 778454443 COLLEGE STATION TX 77845
(979) 690-6626
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . A/C SEER RATING 13.00
CEILING 1 R VAL. (FLAT) 30.00
CEILING 2 R VAL-NO ATTIC 30.00
DUCT R VALUE 6.00
EXTERIOR WALL TYPE STUCCO
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 3.00
TYPE OF GARAGE (ATT/DET) ATT
01 GLAZING 15.00
GLAZING U-FACTOR .65
HEATED AREA 6802.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 5.50
NUMBER OF BEDROOMS 5.00
EXTERIOR WALL INSUL R VAL 13.00
GLAZING SHGC .40
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 411.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . AC
Permit pin number . 579672
Permit Fee . . . . 2660.00 Plan Check Fee .00
Issue Date . . . . 6/10/08 Valuation . . . . 1000000
Expiration Date 12/07/08
---------------------------- ---------------
BUILDING DEPT REPRESENTATIVE:
. . ' n
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . .
Application pin number . . .
Qty Unit Charge Per
08-00001673
728020
BASE FEE
500.00 2.0000 THOU BLDG, VAL 500001 & UP
Page 2
Date 6/10/08
Extension
1660.00
1000.00
Special Notes and Comments
-Elevator to be installed per Manufacturers Installation
instructions.
-Make sure that all operable 2nd floor windows are at least
24" Above Finished Floor.
-Make sure Kitchen Island GFI plugs meet code.
-Narrow Wall Bracing Fully Sheathed with the Study Wall to
be 24" Minimum APA Framed with 211X12" Header. Also Back
door is to be modified to achieve 33" of OSB Minimum.
* THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED
AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTI L CODE
------------------------------------------------ ---� - ------
�rf� -
BUILDING DEPT REPRESENTATIVE:
. --" f • i Z
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00001673 Date 6/10/08
Application pin number . . . 728020
----------------------------------------------------------------------------
Special Notes and Comments
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 150-. the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
----------------------------------------------- ------ ]eg
--------------
BUILDING DEPT RREPPRESSENNTATI E/:
APPLICANT: /C J
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00001673
Application pin number . . . 728020
Page 4
Date 6/10/08
Special Notes and Comments
NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN
2006 IRC
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR
HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE
UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR
COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL
BE PERFORMED PRIOR TO FRAMING INSPECTION.
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE
LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and bove 25% is .46 or
--------------------------------------------------�J--- •-----------
BUILDING DEPT REPRESE,TATIV :
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . . 08-00001673 Date
6/10/08
Application pin number . . . 728020
----------------------------------------------------------------------------
Special Notes and Comments
lower.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2006
IRC )
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
-----------------------------------------------
----------
Permit Fee Total 2660.00 2660.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 3410.00 3410.00 .00
.00
-------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
� ." �l _
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
08-00001674 Date
6/10/08
Application pin number . . .
858760
Property Address . . . . . .
5003 AUGUSTA CIR
Property ID:
497900-0018-0220
R #:
R93888
Application type description
TEMP POLE
Subdivision Name . . . . . .
PEBBLE CREEK
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
SCRUGGS, SHAY W & RONNA S
------------------------
S C STOKES CONSTRUCTION,
INC
810 ROYAL ADELADE DR
5200 WHISTLING STRAITS CT
COLLEGE STATION TX 778454443
COLLEGE STATION
TX 77845
(979) 690-6626
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . AC
Permit pin number . 579698
Permit Fee . . . . 20.00
Issue Date . . . . 6/10/08
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
----------------------------------------------------�-- •---------
BUILDING DEPT REPRESENTATIVE:
..-I . . ,r
APPLICANT:
t For Offi�ce Use Only
APPLICATION FOR BUILDING PERMIT DATE:J/'`' VOTRCC REG /224
CITY OF COLLEGE STATION APPLICATION It ' `
1101 TEXAS AVENUE _og
COLLEGE STATION, TX 77840 TEMP POLE # —
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
09 &7U4
Planning d Development Services
WWWW.CSTX.GOV /
ADDRESS/LOCATION: c) 0 W M W S �� I'1rC. /c, V
LOT _42- Z' BLOCK / '/SUBDIVISION Ae b L /Pl C trt! Q Imo. a✓ SEC/PH
BUSINESS/OWNER NAME: S G S (6 kt5 (+10 IIJ.iI(i( C O N PHONE:
CONTRACTOR/HOMEOWNER: SA y" V (' PHONE:
�,y
CONTACT PERSON FOR REVIEW COMMENTS: � J�Bke s PHONE:
FAX: 7 % ' (� ' f �P 6 EMAIL:
ELECTRICIAN: ' ! � ` ��, W.s (Q.0 � C) PLUMBER: Aq o l"t l/! K- d / �%� fm
HVAC: A I l V GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION" SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEURENOVATION* TENTS
DESCRIPTION OF
PROPOSED USE:
STRUCTURE USE: /`1 d /0 t')
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATIO7340
N## EABPRJ
VALUATION: $ A() D6, nc�o TOTAL AREA: b J 4 0 HEATED AREA:
(Color and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
�0 [RSEWER TAP: L`
� 3 SIZE
WATER TAP:
SIZE
OTHER TAP:
I
TEMP POLE
7 41 GARAGE TYPE:
LA, ^
SIZE
SINGLE El
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
TJ
J
EXTERIOR WALL TYPE: S to C C 10
FOUNDATION TYPE: S A
ROOF TYPE: �i f `/Q.)
DOUBLE TRIPLE K
IETACFAD a CARPORT
SIGNATURE OF APPLICANT: / �� -- z
*If proposed work involves ne commercial cons c Ion 6r facade improvements/renovations to an existing
commercial property, building elevations are required.
............................................................
Official Use Only
V CJ
-FV Plans Examiner
_.EI evafa jLP4t Wev. . t "fa v ck eN s
Z''if )C`e It Waowl ZY "AFF
A40A 5-00 KID• I'f1&J CGFI w%eeff C040
1j/ S�oG �t% two /V1¢ �,,�11 pp�J+11 God �Ji�d� 0��1C �+ � v t �/�tlrv• 0�
Zoning Official
mments:
YE or NO
Energy Code Compliance Information
Glazing of exterior walls' � 15
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas) 0 t/
Insulation R value of ceiling 2 (vaulted areas/no attic) ` 3 O
Glazing SHGC (Solar Heat Gain Coefficient) - �d
Glazing U-Factor G
R value of ductwork l
A/C SEER Rating - 115
Protection Against Subterranean Termites
® Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
.' t10 •. •. � ;! �'""a,.t' �LS�r ` �' y+)s�i. � �% ` r li .
lV y�,• � � j Mtn '•`
. a�M 4i � •� . 4:', �< . `�, v' � .. C,, \� ` 5 .{ � �' • t'. `� � 7:..• a t a,.'H t `ti. �
yf j
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning dDevelopment Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# oS '
DATE:
BUILDING ADDRESS: n iae
�p0 3 v a (! c
I. Foundation Requirements- Minimum Ci Foundati Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
O
E.
Header sizes indicated on plans
NAIqW
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R.
S.
18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
All walls within 3' of property line to have protected openings.
OK
OK
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
N AA K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
Y_
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
O 144
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NffgW
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
71
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
INMO
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
jj 6 - !�`012,P
PLANS EXAMINER DATE