HomeMy WebLinkAboutRES2008-01670, 08-1671City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 6/04/09
Parcel Number . . . . . 230100-1101-0020
Property Address . . . 903 WHITEWING LN
COLLEGE STATION TX 77845
Subdivision Name DOVE CROSSING PH lA
Legal Description . . . DOVE CROSSING SUBDIVISION
PHASE lA
BLK 1 LT 2
Property Zoning . . . . SINGLE FAMILY RESIDENTIAL
Owner
Contractor . . . . . . ED FROEHLING BUILDERS
979 776-8266
Application number 08-00001670 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone
Approved . . . . . . .
B�lding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED 6/02/09, 12:03:51 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/02/09
------------------------------------------------------------------------------------------------
ADDRESS . : 903 WHITEWING LN SUBDIV: DOVE CROSSING PH lA
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER . . PHONE
PARCEL . . 230100-1101-0020
APPL NUMBER: 08-00001670 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 6/24/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00
6/24/08 AP June 24, 2008 8:47:34 AM glsouth.
Strings up. Slab ground installed.
B120 01 6/30/08 BB BLDG, FRAMING -PARTIAL TIME: 17:00
6/30/08 AP June 30, 2008 11:15:32 AM glsouth.
APA FRAME
B115 01 8/06/08 OC BLDG, FRAMING TIME: 17:00
8/06/08 AP August 6, 2008 9:52:47 AM ccourt.
B130 01 8/11/08 RH BLDG, INSULATION TIME: 17:00
8/11/08 AP August 11, 2008 10:09:39 AM bboerboom.
B125 01 6/02/09 BI �.,BLDG, FINAL TIME: 17:00
ejR`VC;�' June 2, 2009 10:26:15 AM kgreen.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
Date: 6/2/2009
Inspection Comments for Finals
Permit Year: 8 Permit Number: 1670
Address: 903 WHITEWING LN
Type
Inspection Type Code
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings up. Slab ground installed.
M100
MECH, ROUGH IN
IC
Connect bath fan ducts by framing.
P105
PLBG, TOP OUT
IC
Finish nail plates and nail guards by framing.
Page 1
WF1044933 /4001`"" City of College Station
PAGE 1
REQ. DATE: 06/10/08 06/10/08 10:43:18
LOCATION: 903 WHITEWING LN LOC ID: 202788
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 06/10/08 SCHED COMPLETION: 06/10/08
********************************************************************************
JOB ORDER RESULT COMIENTS
06/02/2009 14:50 9797740565 ED FROEHLING BUILDER PAGE 02/03
,
ACE PEST CONTROL
T.P.C..L. # 7120 PT
PO BOX 4474
BRYAN, TX 77805
(979) 823-7777
(979) 774-4736
CERTIFICATE
The following property 903 WHIT WING
built by FROEIFI M ROMMS —State of Texas
County of RRLZ_O$ the city of COLLEGE STATION
Mailing Address A M � Zip code 77845
was treated for subterranean termites on this day JRINE 23, 200g --and has met with
approval. Cost of initial treatment, 406A1 is payable upon completion of work. The
treatment is guaranteed for 12 lnGnths from the date of treatment. Thereafter, this
contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection
and renewal fee of 1M lus tax, for a period of_,_, wears. ( see attached letter ) if
at any time during this contract a reinfestation of subterranean termites should occur., the
above said property will be heated at no additional cost to the owner. ACE PEST
CONTROL does not accept any liability for any subterranean termite damage repair.
Failure to pay the annual renewal fee within thirty days after the inspection date shall be
construed as a cancellation of this contract. Any alteration or addition to the foundation
Of tilt above described property without proper toudte treatment by ACE .PEST
CONTROL Services shall. nullify this contract.
Licensed and .licgulated by the
T"m Depart!Mnt ofAgriculturo,
Structural Pest Control Service,
PO -Box 12847, Austin, Texas 78711.2847
(512)305-8250
06/02/2009 14:50 9797740565 ED FROEHLING BUILDER
PAGE 03/03
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
Pr-QpmW Owner: FROEHLING HOMES
L.0_c tiQ to be Tr 903' WHITEVNING
AuPEQ W at@ M easmn,11a Treated:
2779
P��[!C_entaae of'�I c9de�g).to be aoolied at this locafion: 0,06% 93-GAL
�CKp� of Treatme - EMU- _, AWL—myffd6a� x_x
Horizontal/Perimeter Beim XX
Eoursdation; SLAB Sidi. : BR(��
A label of T,�Istar ins�jcide has bee��sa�t o��Us docu
A LA13RL FOR ANY oTNER PESTICIDE RECOMENDFD OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY)
INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OMIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL, OPERATOR TO RE.
TREAT FOR TgRMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNERS ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED,
Charges for pre -treat:
$40641
NOTES: Annual re-newal: .$IX00
322129 PT
Ca a Tnd"8n SP= Ikmnsa r
6/23/2008
32129 PT
+ BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00001670 Date 6/09/08
Application pin number . . . 732450
Property Address . . . . . . 903 WHITEWING LN
Property ID: 230100-0101-0020
R #: R13907
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 146982
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
RD
COLLEGE STATION
TX 77845
(979) 776-8266
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . A/C SEER RATING
13.00
CEILING 1 R VAL. (FLAT)
30.00
CEILING 2 R VAL-NO ATTIC
19.00
DUCT R VALUE
6.00
EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
o GLAZING
12.00
GLAZING U-FACTOR
.64
HEATED AREA
2227.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
5.00
EXTERIOR WALL INSUL R VAL
13.00
GLAZING SHGC
.40
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number
579128
Permit Fee
601.00 Plan Check Fee
.00
Issue Date
6/09/08 Valuation . . .
. 146982
Expiration Date
12/06/08 .
----------------------------------------------
BUILDING DEPT REPRESENTATIVE: '../
APPLICANT
------ /I- --'4--- _'X-t---------
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . .
Application pin number
Qty Unit Charge Per
47.00 3.0000 THOU
08-00001670
732450
BASE FEE
BLDG, VAL 1000,01-500000
Page 2
Date 6/09/08
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with 16" Minimum APA
Garage Framing
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
Extension
460.00
141.00
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
--------PENETRATIONS SEALED
-----------------------------------------�- - -----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00001670
Application pin number . . . 732450
Page 3
Date 6/09/08
Special Notes and Comments
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 150-o the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
* THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED
AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN
2006 IRC
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR
HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE
UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR
COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL
BE PERFORMED PRIOR TO FRAMING INSPECTION.
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
BUILDING DEPT REPRESENTATIVE:
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00001670
Application pin number . . . 732450
Page 4
Date 6/09/08
Special Notes and Comments
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE
LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
----------------------------------------------------- --- -------_--------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . . 08-00001670 Date
6/09/08
Application pin number . . . 732450
----------------------------------------------------------------------------
Special Notes and Comments
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
*GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
*PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR
CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY
BEING ELEVATED A MINIMUM OF 18" ABOVE FLOOR LEVEL.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 601.00 601.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1351.00 1351.00 .00
.00
------------------------------'-- ------------ ---------------- ---- -
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00001671
834685
903 WHITEWING LN
230100-0101-0020
R13907
TEMP POLE
Date 6/09/08
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
RD
COLLEGE STATION
TX 77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 579136
Permit Fee . . .
. 20.00
Issue Date . . .
. 6/09/08
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------------------------
BUILDING DEPT REPRESENTATIVE: �E
APPLICANT:
----- —--------------------
APPLICATION FOR BUILDING PERMIT DATE:
CITY OF COLLEGE STATION APPLICATION /
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE /
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
ADDRE;7BLOCK
TION:
LOT SUBDIVISION % ✓ SEC/PH 1 A
BUSINESS/OWNER NAME: PHONE:
CONTRACTORHOMEOWNER: E b ROE klt-k4 %UI.RPHONE: - (e —&2444
CONTACT PERSON FOR REVIEW COMMENTS: ! " 4.zrk- PHONE: " 71 4'w V54005
FAX: 27+ '0565 EMAIL:
ELECTRICIAN: f5 ORCMIC PLUMBER: T '� %pi
HVAC: GOOD CENTS (Residential only):
ACCESSORY/STORAGE OVING RE -ROOF
ADDITION NEW CONSTRUCTION* SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEL/RENOVATION*
DESCRIPTION OF WORK:
PROPOSED USE: 61 LG'r
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 146 01- ' TOTAL AREA: Z HEATED AREA: 2.22
(Cost of Labor and Materials)
R05UBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP: INTERIOR WALL TYPE: S
SUE
[j?G1IATER TAP: ✓ 4 s• EXTERIOR WALL TYPE: eQ 1KX.
si
OTHER TAP: FOUNDATION TYPE: SILARS (514
Sim
TEMP POLE ROOF TYPE:
GARAGE TYPE: SINGLE DOUBLE Ez TRIPLE
ATTACHED DETACHED CARPORT
SIGNATURE OF APPLICANT: of— '
*If proposed work Involves new commercial construction or facade im ents/renovations to an exist
commercial property, building elevations are required.
Official Use Only
Comments:oNO
w' Plans Examiner Zoning Official
�V1 -t P, 147-CA"s
= -Energy Code Compliance Information
% Glazing of gxterior walls 12��
Insulation R value of exterior walls '
Insulation R value of ceiling 1 (flat areas) , 50
Insulation R value of ceiling '2 (vaulted areas/no attic) jJ A
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor _ �t
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
Chemical Termiticide Treatment Soil Treatment
O Chemical Termiticide Treatment (Field Applied Wood Treatment)
I O Physical Barriers
O Other
* Verification of Application shall be submitted to the City of College Station
. Building Division prior to issuance of the Certificate of Occupancy.
•�:Y fi:..:;,i: i -+•.: t r.�,. �'�,� +f 5 •• ;4�._•y01
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning 6' Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# / w7o
DATE: (`q- Og-
BUILDING ADDRESS: qO3
I. Foundation Requirements- Minimum CityFou�tn2dation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
O
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R.
S.
18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
All walls within 3' of property line to have protected openings.
AWOK
OK
j PLAN REVIEW
(*
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS 4001F� CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Ser vices COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
WOK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum of ten (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
O
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAT
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
i PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning 6- Development Servinr COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA1
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/ft
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NAIM
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
DATE
10" P.U.E.--
ELEC BOX
V FROM CORNER
Lot 1 Block 1
Dove Crossing Subdivision
Scale: 1" = 20'
60'-6" N
SMMTEWING
.y E s L
Lot 3 Block 1
44'-6"---8'-0„
in I ,Concrete :I
N m I onveway
---- ----o e - F L---- - - - - --
qa 3 WHITEWING LANE
50' R.O.W. — 27' Pavement
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: Untitled.rck
TITLE: 903 WW 44.5 5 BED
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 05/29/08
DATE OF PLANS: 4/8/08
PROJECT INFORMATION:
903 WHITEWING LANE
LOT 2 BLOCK I DOVE CROSSING Ilk
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC.
COMPLIANCE: Passes
Maximum UA = 750
Your Home UA = 592
21.1% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.29
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.33
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.29
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2227
30.0
0.0
78
356
13.0
0.0
21
61
0.640 40
38
0.400 15
530 13.0 0.0
41
26
0.640 17
356 13.0 0.0
23
61
0.640 39
Door 2: Glass
SHGC: 0.78
Bldg. faces 135 deg. from North; Comp. orient.:
Projection factor: 1.12
Wall 4: Wood Frame, 16" o.c.
Window 4: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.:
Projection factor: 0.00
Floor 1: Slab -On -Grade: Unheated
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
18
Back
530
61
Right Side
222
0.580 10
13.0 0.0 38
0.640 39
0.0 231
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec4 and to comply with the mandatory requirements listed in
the RES check Inspection Checklist.
Builder/Designer Date S ?�