PREPARED 4/30/09, 7:59:18 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/30/09
------------------------------------------------------------------------------------------------
ADDRESS . : 902 WHITEWING LN SUBDIV: DOVE CROSSING PH lA
' CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER . . PHONE
PARCEL . . 230100-1104-0020
APPL NUMBER: 08-00001668 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 6/19/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00
6/19/08 AP June 19, 2008 10:40:15 AM acarter.
Strings up, slab ground installed.
B120 01 6/30/08 BB BLDG, FRAMING -PARTIAL TIME: 17:00
6/30/08 AP June 30, 2008 11:15:12 AM glsouth.
APA FRAME
B115 01 8/08/08 OC BLDG, FRAMING TIME: 17:00
8/12/08 AP August 8, 2008 10:37:39 AM bboerboom.
B130 01 8/21/08 RH BLDG, INSULATION TIME: 17:00
8/21/08 AP August 21, 2008 10:17:44 AM bboerboom.
B125 01 4/30/09 B BLDG, FINAL TIME: 17:00
/April 30, 2009 7:47:15 AM kgreen.
---------------------------------- COMMENTS AND NOTES --------------------------------------
Kv7.,
Mof
it `
OJ7 6 \�
m
Date: 4/30/2009
Inspection Comments for Finals
Permit Year: 8 Permit Number: 1668
Address: 902 WHITEWING LN
Type
Inspection Type Code
siat�s
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
E150
ELEC, FINAL
IC
Need proper size breaker for condenser by final.
M100
MECH, ROUGH IN
IC
Connect bath fan ducts by framing.
Page 1
04/29/2009 17:27 9797740565 ED FROEHLING BUILDER PAGE 04
D a l WW
Pmpedy der;, FIROEHLING H0MrzS
l�ocatiO.�tQ�e Treated: 902 WHITEWING
�,Proglma e_Mea;lis o ba rea d• 2770.
Eull
Y�xl� xx
Horizontal/Perimeter Beam,_ )O
Eolwnd tiQn�S.I.A� S.idinq;, BRIf�[
ErfirlawAUsLRE�In E gaQf,-14)MPQS�
A R AMEL FOR ANY OTHER PESTt = RECOMMED OR USED NA$ SEEN ATTACHPD AS PART OF THIS DOCUMGMT. WARRANTY IwORMAnON (IF ANY)
INCLUDING AASA COVERED, TIME PERIOD OF wARRANTy. RENEWAL OPTIONSAND cWT, THE OSUGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR Tt RMITE PROTATIONS OR REPAIR DAMAGE CAUSED UY TERM►TE INFESTATIONS WrMIN THE WARRANTY PERID4, AND THE CONDITIONS THAT
COULD DEVELOP AS A RASULT OF THE OWNM$ ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTAGMD
Charges for pine -treat:
NOTES: Annual renewal:
'. Ii� ���,�;�t �� i jj,�. 'h+ivr P fh' i�
$406.0.1
$130.00
32129 PT
CH m Tod*,Mu $PCB 9COMM a
611.912008
=29 PT
04/29/2009 17:27 9797740565 ED FROEHLING BUILDER PAGE 05
ACE PEST CONTROL
T.P.C.L. # 7120 PT
PO BOX 4474
BRYAN, TX 77805
(979) 823-7777
(979) 774-4736
CERTIFICATE
The following property 902 VVIiI'iE G
built by -- c k'ROEHI,ING HOMES _ _State of Texas
County of BRAZ S the city of COLLE§& STAT ON
Mailing AddressSAW Zip code 77 445
was treated for subterranean termites on this day JUNE I9 2008 and has met with
approval. Cost of initial treatment, 406.01 is payable upon completion of work. The
treatment is guaranteed for 12 months from the date of treatment. Thereafter, this
contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection
and renewal flee of x30 plus tax, for a period ofears. (see attached letter) If
at any time during this contract a reinfestation of subterranean temutes should occur, the
above said property will be treated at no additional cost to the owner. ACE PEST
CONTROL does not accept any liability for any subterranean termite damage repair,
Failure to pay the annual renewal fee within thirty days after the inspection date shall be
construed as a cancellation of this contract. Any alteration or addition to the foundation
of the above described property without proper termite treatment by ACE PEST
CONTROL Services shall nullify this contract.
Licensed and Regulated by the
Texas Deparancnt of AV iculturc,
Structural Pcst Control SmVica,
PO Box 12847, Austin, Texas 78711-2847
(512) 305-8250
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE:
(979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
http://bpinspect.cstx.gov
Application Number
. . . . . 08-00001668
Date 6/09/08
Application pin number . . . 527980
Property Address
. . . . . . 902 WHITEWING LN
Property ID:
230100-0104-0020
R #:
R13907
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name
. . . . . .
Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 146982
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME RD
COLLEGE STATION
TX 77845
(979) 776-8266
--- Structure Information
000 000 SINGLE FAMILY
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . A/C SEER RATING
13.00
CEILING 1 R VAL. (FLAT)
30.00
CEILING 2 R VAL-NO ATTIC
19.00
DUCT R VALUE
6.00
EXTERIOR WALL TYPE
BRICK -
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
GLAZING
12.00
GLAZING U-FACTOR
.64
HEATED AREA
2227.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
5.00
EXTERIOR WALL INSUL R VAL
13.00
GLAZING SHGC
.40
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
405.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
AC
Permit pin number
579144
Permit Fee . . .
. 601.00 Plan Check Fee
.00
Issue Date . . .
. 6/09/08 Valuation . .
. . 146982
Expiration Date
12/06/08
--------------------------------------------------
----- ---
--•---'=-----
BUILDING DEPT REPRESENTATIVE:
APPLICANT
�� —►--+
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Page 2
Application Number . . . . . 08-00001668 Date 6/09/08
Application pin number . . . 527980
Qty Unit Charge Per Extension
BASE FEE 460.00
47.00 3.0000 THOU BLDG, VAL 100001-500000 141.00
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with 16" Minimum APA
Garage Framing
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
--------------------------------------------------i�_- - --------
BUILDING DEPT REPRESE�;ATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00001668 Date 6/09/08
Application pin number . . . 527980
----------------------------------------------------------------------------
Special Notes and Comments
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 15% the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38•.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY.MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
* THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED
AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN
2006 IRC
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR
HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE
UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR
COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL
BE PERFORMED PRIOR TO FRAMING INSPECTION.
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
------------------------------------------------ r---------------------------
BUILDING DEPT REPRESENTATIVE: —1 /l .e •
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00001668
Application pin number . . . 527980
Special Notes and Comments
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
Page 4
Date 6/09/08
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 150-o of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE
LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
------------------------------------``J --- - -- -------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: / ��
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number . . . . . 08-00001668 Date 6/09/08
.Application pin number . . . 527980
----------------------------------------------------------------------------
Special Notes and Comments
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
*GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
*PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR
CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY
BEING ELEVATED A MINIMUM OF-18" ABOVE FLOOR LEVEL.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP
4"
350.00
WATER TAP
3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
601.00
601.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1351.00
1351.00
.00
.00
----------------------------------------------- ------ --- ---------
BUILDING DEPT REPRESENTATIVE:
0007'
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00001669
630215
902 WHITEWING LN
230100-0104-0020
R13907
TEMP POLE
Date 6/09/08
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
RD
COLLEGE STATION
TX 77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 577247
Permit Fee . . .
. 20.00
Issue Date . . .
. 6/09/08
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------------------------- -----
BUILDING DEPT REPRESENTATIVE:
APPLICANT •
---� --• -----------
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
S AVNUE
COLLEGE STATION, TX 77840
Crry of COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
y Q �Z Vl/in
ADDRESS�OCATION: 1-6Wina
-LOT `BLOCK ��SUBDIVISION JG�re7 t SEC/PH t A
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: E b T7IROEI.1
�I.II�e1 151ill, PHONE: 77& -6 J
CONTACT PERSON FOR REVIEW COMMENTS: PHONE: - 734-005(P5
FAx: en it • 0565
ELECTRICIAN:
HVAC: _ %--�OV�TIV�
EMAIL:
PLUMBER: TR ,1P+LE S
GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION* SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEURENOVATION*
DESCRIPTION' OF WORK:
PROPOSED USE:
STRUCTURE USE:
iL
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (fAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ I4y • CT8r;- • W TOTAL AREA: 2729 HEATED AREA: Z2211
(Cost oT Labor and Materials)
POPO'UBLIC SEWER
aR SEPTIC/TREATMENT SYSTEM
t.d SEWER TAP: 44�
-EirWATER TAP: 314
s,is
—FIP
_GwiN
OTHER TAP:
TEMP POLE
GARAGE TYPE:
sea
SINGLE 0
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF .BATHROOMS:
INTERIOR WALL TYPE:
5
3
EXTERIOR WALL TYPE: Vg iocK".
FOUNDATION TYPE: 014
ROOF TYPE:; 4y��
DOUBLE TRIPLE
DETACHED F 1 CARPORT
SIGNATURE OF APPLICANT;00"_
*If proposed work involves new commercial construction or facade im ments/renovations to an exisl
commercial property, building elevations are required.
Oflkial Use Only ments:
y` �or NO
Plans Examiner
Zoning Official
Energy Code Compliance Information
%.Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling. I (flat areas) 50
Insulation k value of ceiling 2 areas/no attic) (vaulted
Glazing SHGQ (Solar Heat Gain Coefficient)
Glazing U-Factor G(4-
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
M/Chemical Termiticide Treatment (Soil Tipatmen
0
A
0 Chemical --Termiticide Treatment (Field Applied Wood Treatment)
13 Physical'Barriers
❑ Other
Verification of Application shall be submitted to the City of College',Stati . on
Building Division prior to issuance of the Certificate of Occupancy.
j PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning d Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# _ g
DATE:
O
BUILDING ADDRESS: qaa A i4 wl,
I. Foundation Requirements- Minimum City Foundation Sta dards
N O
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in du lex
K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
CAWOK
OK
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
eNAZK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAjPD
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
(*tl""
i
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NNLnQ
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N O
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
A/ K
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
DATE
Dove Crossing Subdivision
Scale: 1" = 20'
10" P.U.E.--
O y
Nm
60'-0"
ELEC BOX
I'FROM CORNER
N
B.S.L.
(0 ProposPsd
Phaso A
Lot 3 Block 4 Lot mock 4 Lot 1 Block 4
44'-6" T-9"
I 'Concrete � a �j N
I Drivgway cV ro
------�-.-- ---= -- — — —- ----— — — — — --
o:
WHITEWING LANE
50' R.O.W. - 27' Pavement
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release I
Data filename: Untitled.rck
TITLE: 902 W W 44.5 5 BED
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 05/29/08
DATE OF PLANS: 4/8/08
PROJECT INFORMATION:
902 WHITEWING LANE
LOT 2 BLOCK 4 DOVE CROSSING 1J%
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC.
COMPLIANCE: Passes
Maximum UA = 750
Your Home UA = 592
2 1. 1% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Ceiling 1: Flat Ceiling or Scissor Truss
Wall l: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Front
Projection factor: 0.29
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame: Double Pane with Low-E
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Left Side
Projection factor: 0.33
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 0.29
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2227
30.0
0.0
78
356
13.0
0.0
21
62
0.640 40
38
530 13.0 0.0
26
0.400 15
41
0.640 17
356 13.0 0.0 23
61 0.640 39
Door 2: Glass 18 0.580 10
SHGC: 0.78
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 1.12
Wall 4: Wood Frame, 16" o.c. 530 13.0 0.0 38
Window 4: Metal Frame: Double Pane with Low-E 61 0.640 39
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Right Side
Projection factor: 0.00
Floor 1: Slab -On -Grade: Unheated 222 0.0 231
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec/ and to comply with the mandatory requirements listed in
the RESchecklnspection Checklist.
Builder/Designe Date S �8