HomeMy WebLinkAboutRES2008-01667City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 9/19/08
Parcel Number . . . . . 230100-0103-0040
Property Address . . . 3707 DOVE HOLLOW LN
COLLEGE STATION TX 77845
Subdivision Name . . .
Legal Description . . . DOVE CROSSING PH 1C
BLK 3
LOT 4
Property Zoning . . . . SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . . .
Contractor . . . . . . ED FROEHLING BUILDERS
979 776-8266
Application number 08-00001667 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
I "C A.
Approved . . . . . .
B ld ng Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
(9/18/2008) Beth Boerboom - Re: Calling for CO for 3707 Dove Hollow Ln Pagel
From: Paul Schoenfeld
To: Benjamin McCarty; Beth Boerboom; Chris Haver; Christina Court; Gina
Date: 9/18/2008 4:08 PM
Subject: Re: Calling for CO for 3707 Dove Hollow Ln
NO for CO.
Sewer buried.
Paul
>>> Beth Boerboom 09/18/08 12:15 PM >>>
BP 08-1667
Any issues?
Beth Boerboom, Customer Service Rep.
Planning & Development Services
City of College Station
979.764.3570
www.cstx.aov
PREPARED 9/18/08, 11:58:01 INSPECTION TICKET PAGE 5
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/18/08
------------------------------------------------------------------------------------------------
ADDRESS . : 3707 DOVE HOLLOW LN SUBDIV:
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER . . PHONE
PARCEL . . 230100-0103-0040
APPL NUMBER: 08-00001667 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 6/25/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00
6/25/08 AP June 25, 2008 8:58:27 AM acarter.
Strings up. Slab ground installed.
B120 01 7/16/08 OC BLDG, FRAMING -PARTIAL TIME: 17:00
7/16/08 AP July 16, 2008 10:24:02 AM ccourt.
APA- GARAGE
B115 01 8/06/08 OC BLDG, FRAMING TIME: 17:00
8/06/08 AP August 6, 2008 9:53:35 AM ccourt.
B130 01 8/19/08 RH BLDG, INSULATION TIME: 17:00
8/19/08 AP August 19, 2008 10:28:37 AM glsouth.
B125 01 9/18/08 BI BLDG, FINAL TIME: 17:00
lap a>
1 September 18, 2008 9:29:24 AM bboerboom.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
'x_(MT ,gTSoJ 4STjkU cb ---t> pf5 ;Z82(a
0�_
SUBTERRANEAN TFAMTE P
REC��''#QN
DISCLOSURE FOR EACH ES'l�i�,�;'I'-�
For all treatments there will be a diagram showing exactly what will be-traate Prior to the beghin4 of
treatment. Review the pesticide label provided to you at this time for miniuuun treatment standards.
Remember that your architects or design engineers specifications must also be followed, unless they are
in violation of the law. Review the consumer information sheet for fiuther information. If you have any
questions, contact the pest control company or the Texas Department of Agriculture, Structural Pest
Control Service, P.O. Box 128.47, Austin, Texas 78711 2847, phone: (512) 305-8250,
Name of Customer
Address '
6ty State Zip
Location to be Treated —7 ' ' �* r
Type of Treatmant: [ ] Full f-pjifial
Q�
A label of r� '6't
[ ] Wood f ] Bait [ ] Commercial (.iSingle family
The percentage of the termiticide(s) to be applied at this location is ' 06
is enclosed.
W4rrardy AfOrmadon prvvlded nuw Lwlude the Complete Details of aqy Warranty provided acid the
1'arAw' 9' 7tow Period of Warranty, RMCW4l 0pt10ds and Cost; and 061adorns of am Contracting
Xf the warranty does not include the entire structure treated, the areas included in the warranty are:
(Specify)
Total Square Feet to be Treated. Total Linear Feet to be Treated:
Approximate Measurements of the Structures) to be Treated:
vt
r01
all 61
(�
Signature of Certified Applicator or
Technician CompletingE,sti
Ac-e__ ;�e 5 f 7,a
l
Name of Pest Control Company
Printed Name
TPCL. No.
PT
Date
Lle msed and regulated under the Texas Structural Pest Control Act
Texas 17epar(meut of Agriculture, Strwtural pest Control Service, P.O. Box 12847, Austin, TMs 78711-2947, Phone: (512)
305-9250.
Sample Form —09/01/07
Page 1 of Z
Z0 39Vd a3G-lins 9NIIH3OaA Q3 9990VLL6L6 60:Zi 800Z/9T/60
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
PrropOrW Owner- FROEHLING HOMES
Location tQ be Treated: 3707 DOVE HOLLOW
2436
Percentage of Termticide-A to be applied at this locau= 0.06144rOA .
Type of Treatment: Full Partial XX Verrticai Xx
Horizontal/Perimeter Beam_XX
A L,AAEL FOR ANY OTHER POMIDE RECOLWWED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY)
INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE -
MEAT FOA TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID TN4 WARRANTY HAS ALSO PEEN ATTACHED,
Charges for pre -treat:
NOTES: Annual re-newal:
Maw,
.}fLyj�jJ�'�h
# si l .�felA'Oi2L1 Y 1�1�W1. , �'a. �!{l„�:�'.`;.
$356.9.0
$125.00
32129 PT 6/24/2008
Ca w TwMnclm SM 11consu # 32129 PT
60 39Vd dMlif1H 9NI-1H30dJ Q3 9990PLLGL6 60:TT 800Z/9T/60
WF1044931 V .00L City of Coll'age Station
• -PAGE 1
REQ. DATE: 06/10/08 06/10/08 10:42:17
LOCATION: 3707 DOVE HOLLOW LN LOC ID: 205486
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 06/10/08 SCHED COMPLETION: 06/10/08
********************************************************************************
JOB ORDER RESULT COMMENTS
BUILDING PERMIT '
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00001667 Date 6/09/08
Application pin number . . . 425745
Property Address . . . . . . 3707 DOVE HOLLOW LN
Property ID: 230100-0103-0040
R #: R
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 175956
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
RD
COLLEGE STATION
TX 77845
(979) 776-8266
--- Structure Information
000 000 SINGLE FAMILY
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . A/C SEER RATING
13.00
CEILING 1 R VAL. (FLAT)
30.00
CEILING 2 R VAL-NO ATTIC
19.00
DUCT R VALUE
6.00
EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
GLAZING
10.00
GLAZING U-FACTOR
.65
HEATED AREA
2666.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
5.00
EXTERIOR WALL INSUL R VAL
13.00
GLAZING SHGC
.40
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
405.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. AC
Permit pin number
579151
Permit Fee
688.00 Plan Check Fee
.00
Issue Date
6/09/08 Valuation . . .
. 175956
Expiration Date
12/06/08
- --------------- ----- --------------------------
BUILDING DEPT
REPRESENTATIVE:
..uv
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . .
Application pin number . .
Qty Unit Charge Per
76.00 3.0000 THOU
08-00001667
425745
BASE FEE
BLDG, VAL 100001-500000
Page 2
Date 6/09/08
Extension
460.00
228.00
Special Notes and Comments
-Make sure Garage Ceiling has 5/8" Type X Sheetrock
-@nd Floor Operabl Windows must be 24" AFF
-Narrow Wall Bracing Fully Sheathed with 16" Minimum Garage
APA and 20" Minimum Dining Room APA Framing.
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR ESIDENNTIAL
— _--------
-
------------------------------------
------------��!•-- -
'
BUILDING DEPT REPRESENTATIVE:
APPLICANT;
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00001667 Date 6/09/08
Application pin number . . . 425745
----------------------------------------------------------------------------
Special Notes and Comments
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 150-. the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
* THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED
AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN
2006 IRC
-------------------------------------`�J--- - -`------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00001667 Date 6/09/08
Application pin number . . . 425745
----------------------------------------------------------------------------
Special Notes and Comments
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR
HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE
UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR
COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL
BE PERFORMED PRIOR TO FRAMING INSPECTION.
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE
LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*ALL SILLS AND BOTTOM PLATES IN CONTACJH CONRETE MUST BE-------------------------------------------------- - - - ------
.xs+tc
BUILDING DEPT REPRESENTATIVE:
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number . . . . . 08-00001667 Date 6/09/08
Application pin number . . . 425745
----------------------------------------------------------------------------
Special Notes and Comments
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2006
IRC )
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
*GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
*PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR
CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY
BEING ELEVATED A MINIMUM OF 18" ABOVE FLOOR LEVEL.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP
4"
350.00
WATER TAP
3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid -
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
688.00
688.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1438.00
1438.00
.00
.00
------------------------------------------------
BUILDING DEPT
REPRES TATIVE:
------ ----
--"-- ti ------
APPLICANT:
��
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
Crrx OF COLLEGE STATION (979) T64-3570 (979) 764-3496 FAX
I'LMrKdDnra�rSr.►�ner WWW.CSTX.GOV
DATE: _ — 'TRC(
APPLICATION /
TEMP POLE #
ADDRESS/LOCATION: O "0 1O -✓ t�
LOT 4/BLOCK 3 SUBDIVISION �� ��'SSw�el SEC/PH I L
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: E b FaoE �11.II �3VI1.001� PHONE:
CO T PERSON FOR REVIEW COMMENTS: PHONE: 734-00544
F�-" �� 4 • oSGS
*EIAN: EEC'��.IC.
�rAc: 11tJ�•lQyATwrc
EMAIL:
PLUMBER: TR S
GOOD CENTS (Residential only):
AACCVVD Wf RAGE OVING RE -ROOF
iT��� �� NEW CONSTRUCTION' SHELL ONLY
^../NN (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
(LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL.
L .Lr1.,n,ION4 REMODEL/RENOVATION'
DESCRIPTION OF WORK:
PROPOSED USE:
I
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS/) PROJECT REGISTRATION# EALBPRJ L
VALUATION: $ 17s}/41S6• - ✓ TOTAL AREA: 3Z I v_ HEATED AREA: 2666
(Cost of Labor and Materials)
DePUBLIC SEWER
F� SEPTICrrREATMENT SYSTEM
NrSEWER TAP:
• Cj2o�NATER TAP:
.l 1�„ s•
�(
OTHER TAP:
Bug
TEMP POLE
sae
GARAGE TYPE:
SINGLE a
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE E TRIPLE
J,. DETACHED I CARPOR
� >• 1 s
_•A Vie` Ill
SIGNATURE OF APPLICANT:
'If proposed work involves new commercial construction or facade Improv renovations to an exist
commercial property, building elevations are required.
OffkJal use only C mments:
17% ��G%corNO
--• S��ir2t Plans Examiner Zoning Official
G" wl N
- z & IP4M WrAj uwr zy„
Fury skeA41uJ &,/ APA Ib'' #Kf,j@GAd-W �-
'o 'k.
Energy Code Compliance Information
% Glazing of exterior walls 10%
Insulation R value of exterior walls
Insulation R value of ceiling I (flat* areas) so
Insulation R value of ceiling 2 (vaulted areas/no attic)Q `/
Glazing SHGQ (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
I/Chemical Termiticide.Treatment (Soil Tieatment)
0 Chemical Termiticide Treatment (Field Applied Wood Treatment)
0 Physical Barriers
0 Other
U
Verification of Application shall be submitted to the City of College Station
on
Building Division prior to.issuance of the Certificate of Occupancy.
A k -
f PLAN REVIEW
(*tl ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
DATE:
BUILDING ADDRESS:
3 o Dow L.AI .
I. Foundation Requirements- Minimum City Foundation Standards
N
K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
N
K
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
MWOK
OK
M
PLAN REVIEW
(*//q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning crDevelopment Servicet COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
N
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
I
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
E
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
p
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
i
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
`
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
�1
CITY OF COLLEGE STATION
Planning cr Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for as appliances when required)
VIII. EnergyRequirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energydata supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
,_ L- L
vVILAN9 EXAMINER
DATE
May, 7, 2008 2;14PM McClure & Browne Eng/Surveying,
,�1 CLUREc�BRO`YNEENG/VEER/N 'URt�EY/NG, /NC• >A?BfYoadc .¢Drivc SLAP AV - allege r�rasn8�'•/3�1.��d ?B
Lot 04 Block 03.dwq
Common Area
Now or Formerly
Phi —Ton Investments
Vol, 7478. Pg. 068
20' P.U.E. 5 48V4a9" E' — 55' 00'
B.S,L
Lot 4
Now or Formerly
Ed Froehling Builder, Inc
I
Vol. 7925, Pg_ 184
�1
I
Z
TE — _, —.—
Note: Building $Mock Linea per
ll City of College Stotio� Unified
Development Ordinance #2817 I 1
3707 Dove Hollow Lone
Lot A Block 3
Dove Crossing, Ph. 1C
ro �
Proposed
Residence
7.0
I I
I I
I Proposed
n� Drrvcway
N I I ifj
— 5' P.U.E. m ^�r
N 48V4'39" W = 55. 00'
Dove Hollow Lane
50' R.O.W. — 27' Pavement
Wal, 7478, Pg. 66
Scale:
S"=20'
7.5'
B.S.L
ti
Lot 6
Now or Formerly
1 Ed Froehling Builder, Inc
Vol. 7925, Pg. 184
�
w,
;I
1
R
1
7.8'
REScheck Compliance Certificate
2000 IECC
RES check Software Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\3707DH LILLY.rck
TITLE: 3707DH
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 05/26/08
DATE OF PLANS: 3/12/08
PROJECT INFORMATION:
3707 DOVE HOLLOW LANE
LOT 4 BLOCK 3
DOVE CROSSING 1 C
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
LILLY
COMPLIANCE: Passes
Maximum UA = 974
Your Home UA = 710
27.1 % Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.35
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Front
Projection factor: 0.29
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Left Side
Projection factor: 0.40
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
1886
30.0
0.0
66
780
30.0
0.0
27
316
13.0
0.0
19
42
0.640 27
38
510 13.0 0.0
29
0.400 15
39
0.640 18
Wall 3: Wood Frame, 16" o.c.
316
13.0 0.0
18
Window 3: Metal Frame:Double Pane with Low-E
75
0.640
48
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.29
Door 2: Glass
18
0.580
10
SHGC: 0.78
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.25
Wall 4: Wood Frame, 16" o.c.
510
13.0 0.0
35
Window 4: Metal Frame:Double Pane with Low-E
78
0.640
50
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Right Side
Projection factor: 0.29
Wall 5: Wood Frame, 16" o.c.
229
13.0 0.0
19
Wall 6: Wood Frame, 16" o.c.
327
13.0 0.0
23
Window 5: Metal Frame:Double Pane with Low-E
51
0.640
33
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Left Side
Projection factor: 0.40
Wall 7: Wood Frame, 16" o.c.
229
13.0 0.0
19
Wall 8: Wood Frame, 16" o.c.
327
13.0 0.0
26
Window 6: Metal Frame:Double Pane with Low-E
4
0.640
3
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Right Side
Projection factor: 2.00
Floor 1: Slab -On -Grade: Unheated
206
0.0
215
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described
here is consistent with the building
plans, specifications,
and other calculations submitted with the permit application. The
proposed
building has been designed to
meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory
requirements listed in
the REScheckInspection Checklist.
Builder/Design
Date