INSPECTION TICKET PAGE 1
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 7/14/09
------------------------------------------------------------------------------------------------
ADDRESS
. : 5310 RIVIERA
CT
SUBDIV: PEBBLE CREEK
CONTRACTOR CLAY KOLBY HOMEBUILDING, LLP PHONE (979) 777-9840
OWNER .
.
PHONE
PARCEL .
. 497900-0946-0230
APPL NUMBER: 08-00001605
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING
PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
7/02/08
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
7/02/08
AP
July 2, 2008 8:03:39 AM acarter.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
8/25/08
OC
BLDG, FRAMING TIME: 17:00
8/25/08
AP
August 25, 2008 10:09:14 AM bboerboom.
APA inspection requested for 4 spots.
B�15 02
9/15/08
RH
BLDG, FRAMING TIME: 17:00
4
9/15/08
DP
September 11, 2008 3:06:19 PM bboerboom.
1
Need to submit drawings for detached garage. Detached garage
does not meet APA requirements. Fireplace flue needs min. 2"
from combustibles. Need blocking between flor joist above
wall between garage and kitchen. Need joist hanger at master
closet. Need anchor between the two back doors. Tape seal
all penetrations through Tyvek.
B115 03
9/19/08
RH
BLDG, FRAMING TIME: 17:00
9/19/08
AE
September 18, 2008 4:29:02 PM 'ccourt.
Install blocking between floor joist above wall between
kitchen and garage. Finish installing metal panel at
detached garage. By insulation.
B130 01
9/29/08
BH
BLDG, INSULATION TIME: 17:00
9/29/08
AP
September 29, 2008 4:41:59 PM glsouth.
B125 01
7/13/09
RH
BLDG, FINAL TIME: 17:00
7/13/09
DP
July 13, 2009 9:17:05 AM ccourt.
Post energy requirements. Relabel electrical panel where its
easier to read. Smoke detector is too close to fan upstairs
as noted on elect.final. needs amin. 3 ft from fan blades
and a/c vents. Bottom section of handrail for stairs is too
low. 34" min. Some plumbing vent pipes not flashed at roof.
B125 02
QED-
BI
BLDG, FINAL TIME: 17:00
July 14, 2009 11:40:29 AM ccourt.
-------------------------------------- COMMENTS AND NOTES--�-------- --
6_q__ 7411e�
c
(9/29/2008) Gina Southerland,- Insulation request inspection result'; 53J10 Riviera, #08-1605 Page 1
From:
Brian Henry
To:
Southerland, Gina
Date:
9/23/2008 3:36 PM
Subject:
Insulation request inspection result, 5310 Riviera, #08-1605
CC:
Carter, Amber
Print for file
Inspected insulation, 5310 Riviera, #08-1605, Clay Kolby Homes 9-23-08
Inspection result: Inspected OK for Good Cents
JUL-20-2009 14:09 From:9797744736 To:7643496
Page:2,2
" TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
Prod O1Nt .1 CLAY KOLBY HOMEBUILDING, INC.
Location to be Treated: 5310 RIVIERA CT.
"57
Perce tacic of YermtlSide(s) to b�
^+ 0.06 /oT49'.C�IA r. �r:ii«o
B..Qf_Treatment:Full Partial _XX_ y
Horizontai/Perimeter Beam—XX_
Fol�Jidation: SI..AB S.ifllnla: BRICK
Primary Use: RESIDENCE f3�t: COMPt,�$ITION
Alib"Jaistar insgCji, id has boortis document_
A LABEL hOR ANY OTHER PESTICIDE RECOMENOEO OR USED HM RF.FN ATTACHED A$ PART OF THIS DOCUMENTWARRANTY INFORMATION (IF ANY)
INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY. RENEWAI. OPTIONSAND COST. THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERNITF INFESTATIONS OR REIYUR DAMAGE CAUSED By TFRMRC INFESTATIONS WITHIN THE WARP_"rV PFRIOD, AND THE CONLWTIDM THAT
COULD DEVELOP AS A RCSUI.I OF THE OWNER•$ ACTION OR INACTION THA I WOULD VOID TI'IC WARRANTY HAS ALSO SLCP,N ATTACHED.
Charges for pretreat:
NOTES: Annual re-newal:
Ra
BUILDNESIII'PL;IES+ KETCH/'PLAN" -
�L_J°hoD
C I )�rS
$723.02
$140.00
32129 PT
Ce or T.entndw 3PC6 Men** r
6/2712008
321" PT
1
WF1041891 / 001 City of -College Station
PAGE 1
REQ. DATE: 06/02/08 06/02/08 12.:52:03
LOCATION: 5310 RIVIERA CT LOC ID: 210902
REQUESTOR: CLAY KOLBY HOMEBUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/411
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 06/02/08 SCHED COMPLETION: 06/02/08
********************************************************************************
JOB ORDER RESULT COMlENTS
BUILDING;'PERMIT
'CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00001605 Date 6/02/08
Application pin number . . . 031000
Property Address . . . . . . 5310 RIVIERA CT
Property ID: 497900-0946-0230'
R ## .
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . PEBBLE CREEK
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 450000
Owner Contractor
------------------------ ------------------------
CLAY KOLBY HOMEBUILDING, LLP
P.O. BOX 8
NAVASOTA TX 77868
(979) 777-9840
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . A/C SEER RATING 14.00
CEILING 1 R VAL. (FLAT) 30.00
CEILING 2 R VAL-NO ATTIC 19.00
DUCT R VALUE 6.00
EXTERIOR WALL TYPE BRICK/STONE
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 3.00
TYPE OF GARAGE (ATT/DET) ATT/DET
0-8 GLAZING 14.00
GLAZING U-FACTOR .35
HEATED AREA 3742.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 4.50
NUMBER OF BEDROOMS 4.00
EXTERIOR WALL INSUL R VAL 13.00
GLAZING SHGC .28
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 426.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 576967
Permit Fee . . . . 1510.00 Plan Check Fee .00
Issue Date . . . . 6/02/08 Valuation . . . . 450000
Expiration Date 11/29/08
------------------------------------------
0 -- -----------------
BUILDING DEPT REP�RESEDI�TIVE�^
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00001605 Date 6/02/08
Application pin number . . . 031000
Qty Unit Charge Per Extension
BASE FEE 460.00
350.00 3.0000 THOU BLDG, VAL 100001-500000 1050.00
----------------------------------------------------------------------------
Special Notes and Comments
-Make sure 2nd Floor windows are at least 24" Above Finished
Floor
-Garage Ceiling must have 5/8" Type X Sheetrock
-Narrow Wall Bracing Fully Sheathed with 20" Minimum APA
Framing with 21IX12" Minimum Header to be used in Bedroom #2
and Family Room Areas.
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PEj22O 5 National Electrical
------------------------------------ -------/'�J•--------------
BUILDING DEPT REPItESEM70IVE:
APPLICANT:
r-
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00001605
Application pin number . . . 031000
Page 3
Date 6/02/08
Special Notes and Comments
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 15t the Values Shall be
R-13 and R-30, above 15t the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
* THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED
AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTIO OF PROPERTY LINES
------------------------------------------ ----- - -------------
BUILDING DEPT REPRESENTATIVE -
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00001605 Date 6/02/08
Application pin number . . . 031000
----------------------------------------------------------------------------
Special Notes and Comments
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN
2006 IRC
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR
HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE
UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR
COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL
BE PERFORMED PRIOR TO FRAMING INSPECTION.
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE
LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 200-o.40 O LOW P"AC $ AND
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . . 08-00001605 Date
6/02/08
Application pin number . . . 031000
----------------------------------------------------------------------------
Special Notes and Comments
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2006
IRC )
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------
------------------------------
Permit Fee Total 1510.00 1510.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 2260.00 2260.00 .00
.00
--� - -
-------------- - - -
BUILDING DEPT REPRY-�EN;PATIVE ,-
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00001607
235400
5310 RIVIERA CT
497900-0946-0230
Date 6/02/08
TEMP POLE
PEBBLE CREEK
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
CLAY KOLBY HOMEBUILDING, LLP
P.O. BOX 8
NAVASOTA
TX 77868
(979) 777-9840
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit pin number
. 576975
Permit Fee . . .
. 20.00
Issue Date . . .
. 6/02/08
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
--------------------
Due
Permit Fee Total
20.00
----------
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRFFNTATIVE:
% �l rt--
APPLICANT:
.woft.
CrryoF COLLEGI; STATION
rw.ftdta.&rwim
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 7844W0 (979) 764-34H FAX
W W W.CSTX.GOV
ADDRESs/LOCATION: 'S 51.0 1 C (V l EQ A
LOT 2-3,✓ BLOCK I&ylSUUVIVISION I
BUSINESSIOMER NAME:
DATE:
APPLICATION 0
TEMP POLE 0
SEC/PH F ✓
PHONE: -777— j%q0
CONTRACTORMOMEOYVNER: PHONE:
CONTACT PERSON FOR REVIEW COMMENTS:
FAX 2(�0—cin06
ELECTRICIAN: 1411. (- o
HVAC: '!!�te6'F4 j
PHONE:
EMAIL:
PLUMBER: Tzl
GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION' SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) pORTAsLE STORAGE (RESIDENTIAL} SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL SWIMMING POOL
LOCATION RaMODEL/RENovATIoN' TENTS
DESCRIPTION OF WORK: 6w t'n K1 Fw wtw-e
PROPOSEDUSE: RIF5119Ei"GE
STRUCTURE USE: IU-s & b'e^cf-
HOMEOWNER ASSOCIATIOWARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISiRATiONN EABPRJ
VALUATION: $ 4f 5-6L6-u-b y TOTAL ARFALI ( HEATED AREA:
t� a L� wd Matetlab) S7 OOet
PUBUC SEWER NummKoF BEDROOMS:
SEPW./TRJEATMENT SYSTEM NUMBER OF BATHROOMS: � S
M SEWER TAP: INTERIOR WALL TYPE: I Z 5 �fi ET2�
WATER TAP: 57q
11 EXTERIOR WALL TYPE:sw
C.l S TAN $ o
0 OTHER TAP: i=OUNDATiON TYI'E 5C 415 C9`I 64041;—,
TEMP POLE ROOF TYPE:
v) GARA(IE TYPE: SINGLE DOUBLE rM TRIPLE r7 p OU gt,C A TTlkkftw/)
ATTACHE p DETACHED.ro CARPORT (� 5 1 A) GLE 9 F T AG (4VD
SIGNATURE OF APPLICANT:
"If proposed work involves new cOnVMrci8-rd&v9ffw6tiOn ojTb9ade impnuvernents/renovations to an existing
commercial property, building elevations are required.
Offs" Use Ow
—. Ft p
Plans Examiner Zoning Official ES NO
—:y IAeJtu' Aee.crl
— /-,,--f4vu /9~; cot
- r-v IN SLw&W wl z, Ir Al rN• AOi4 W1 ZX i L
g &J"90., of Z f- It kook. 17 tetJ I
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R. value of exterior walls
Insulation R. value of ceiling 1 (flat -areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar He4 Gain Coefficient)
Glazing U-Factor
K value of ductwork
A/C SEER Rating
Protection against Subter�%wean Termites
Chemical Termiticide "Treatment (Soil Treatment)
❑ Chemical Termiticid� Treatment (Field Applied Wood Treatment)
❑ Physical Bar iers
❑ Other i
* Verification of Appli tiona shall be submitted to the City of College Station
Building Division pri r to issuance of the Certificate of Occupancy.
PLAN REVIEW
(*. tl"" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
D -l&os
DATE:
s-3o-o8
BUILDING ADDRESS:
5310 / ivi eAC4.
I. Foundation Requirements- Minimum City Foundation Standards
N
ffO K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
MCLK
Il. Framing:
Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
NA0K
E.
Header sizes indicated on plans
Nkoll
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
VOK
OK
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairwa Details
N AfQrK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N K
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
i (*f/,"
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
Na
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N401
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
DATE
4-,
REScheck Software Version 4.1.4
Compliance Certificate
Project Title: 5310 Riviera
Report Date: 05/29/08
Data filename: C:\Program Files\Check\REScheck\5310 Riviera.rck
Energy Code: 20001ECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 14%
Heating Degree Days: 1788
Construction Site:
Owner/Agent:
Designer/Contractor.
Clay Kolby Homebuilding Inc
Compliance: 37.5% Better Than Code Maximum UA: 1041 Your UA: 651 Maximum SHGC: 0.40 Your SHGC: 0.28
Gros Cave Con Glazi g U
sse� Are o R- lu - aW o Doo
elttt, _ - Ct0
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Vinyl Frame:Double Pane with Low-E
SHGC: 0.27
Door 1: Solid
Door 2: Glass
SHGC: 0.33
Furnace 1: Forced Hot Air 78 AFUE
Air Conditioner 1: Electric Central Air 14 SEER
3742 0.0 30.0 116
4244 13.0 0.0 296
486 0.350 170
24 0.600 14
120 0.460 55
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Version 4.1.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
Project Title: 5310 Riviera
Data filename: C:\Program Files\Check\REScheck\5310 Riviera.rck
Report date: 05/29/08
Page 1 of 4
RESc eck Software Version 4.1.4
Inspection Checklist
Date: 05/29/08
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade. Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For wkxk)ws without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.600
Comments:
❑ Door 2: Glass, U-factor: 0.460
Comments:
Heating and Cooling -Equipment:
❑ Furnace 1: Forced Hot Air: 78 AFUE or higher
Make and Model Number.
❑ Air Conditioner 1: Electric Central Air. 14 SEER or higher
Make and Model Number.
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in
accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible
materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Materials. Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ k►sulation R-values, glazing U-factors, and c oohng equipment efficiency are clearly marked on the buildkV plans or specifications.
❑ Insulation is installed according to manufacturers instructions, in substantial contact with the surface being insulated, and in a manner
that achieves the rated R-value without compressing the insulation.
Duct Insulation:
0 Ducts in unconditioned spaces are insulated to at least R-5. Ducts outside the building are insulated to at least R-8.0.
Duct Construction:
❑ All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastfc-plus-embedded-fabric, or
tapes. Tapes and mastics are rated UL 181A or UL 181B.
Project Title: 5310 Riviera
Data filename: C:\Program Files\Check\REScheck\5310 Riviera.rck
Report date: 05/29/08
Page 2 of 4
Excepdons
r
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:.
❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
is part of a circulating system.
Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time dock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Project Title: 5310 Riviera Report date: 05/29/08
Data filename: C:\Program Files\Check\REScheck\5310 Riviera.rck Page 3 of 4
Table 1: Minimum-insulatio►1 Thickhess for Circulating Hot Water Pipes
insulation Thickness in Inches by Pipe Sizes
Non-Circulating-Runouts
Circulating Mains and Runouts
Heated Water
Up to 1"
-- Up to 1.25"
1.5" to 2.0"
Over 2"
Temperature ("F)
17 -48U
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 4-Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
- Fluid Temp.
Piping System Types
Range("F)
2" Runouts 1" and Less
1.25" to 2.0"
2.5" to 4"
Heating Systems
Low. Pressurerremperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
Project Title: 5310 Riviera .Report date: 05/29/08
Data filename: C:\Program Files\Check\REScheck\5310 Riviera.rck Page 4 of 4