HomeMy WebLinkAboutRES2008-01599l;
WF1044929,/.001 City of College Station PAGE 1
REQ. DATE: 06/10/08 06/10/08 10:41:42
LOCATION: 1101 HARRISONBURG LN LOC ID: 202662
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 06/10/08 SCHED COMPLETION: 06/10/08
********************************************************************************
BUILDING PERMIT .�.:.
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00001599 Date 6/09/08
Application pin number . . . 905990
Property Address . . . . . . 1101 HARRISONBURG LN
Property ID: 569500-1438-0080
R #: R302506
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 173316
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDER INC ED FROEHLING BUILDERS
3887 HIGH LONESOME 3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . A/C SEER RATING 13.00
CEILING 1 R VAL. (FLAT) 30.00
CEILING 2 R VAL-NO ATTIC 19.00
DUCT R VALUE 6.00
EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
GLAZING 10.09
GLAZING U-FACTOR .64
HEATED AREA 2626.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 5.00
EXTERIOR WALL INSUL R VAL 13.00
GLAZING SHGC .40
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 427.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . AC
Permit pin number . 579169
Permit Fee . . . . 682.00 Plan Check Fee .00
Issue Date . . . . 6/09/08 Valuation . . . . 173316
Expiration Date 12/06/08
-
----------------------------------------------- -----� -----
-- --- -----
BUILDING DEPT REPRESENTATIVE:
APPLICANT: e
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00001599 Date 6/09/08
Application pin number . . . 905990
Qty Unit Charge Per Extension
BASE FEE 460.00
74.00 3.0000 THOU BLDG, VAL 100001-500000 222.00
----------------------------------------------------------------------------
Special Notes and Comments
-Right side of property has 10' PUE that structure can not
encroach.
-All 2nd floor operable windows must be 24" AFF
-Garage ceiling sheetrock to be 5/8" Type X due to habitable
space above
-Narrow Wall Bracing Fully Sheathed with 16" Minimum APA
Garage Framing.
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
--------------------------------------------- -� - --------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Page 3
Application Number . . . . . 08-00001599 Date 6/09/08
Application pin number . . . 905990
----------------------------------------------------------------------------
Special Notes and Comments
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 15% the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
* THE MAXIMUM ALLOWABLE RESIDENTIAL DRIVEWAY WIDTH MEASURED
AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
--------------------------------------- -- -----------
BUILDING DEPT REPRESENTATIVE: vim.!•
APPLICANT:w
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00001599 Date 6/09/08
Application pin number . . . 905990
----------------------------------------------------------------------------
Special Notes and Comments
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN
2006 IRC
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR
HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE
UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR
COVER-UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL
BE PERFORMED PRIOR TO FRAMING INSPECTION.
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON SITE
LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING N PERCENTAGE OF WALL
--------------------------------------------- ------ ---+- ----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number . . . . . 08-00001599 Date 6/09/08
Application pin number . . . 905990
----------------------------------------------------------------------------
Special Notes and Comments
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2006
IRC)
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
*GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
*PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR
CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BY
BEING ELEVATED A MINIMUM OF 18" ABOVE FLOOR LEVEL.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
--------------------------------------------- ----- --- ----- -•----------
BUILDING DEPT REPRESENTATIVE: .*+�
.I / —
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Permit Fee Total 682.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1432.00
08-00001599
905990
682.00
.00
750.00
1432.00
Page 6
Date 6/09/08
.00
.00
.00
.00
.00
.00
.00
.00
---------------------------------------------------�-- --------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
P4iurIM d Dswfojmmr Servim
W W W.CSTX.GOV
ADDRESS/LO
CATION: b I
LOT BLOCK 3 v SUBDIVISION
BUSINESS/OWNER NAME:
DATE: � TRCCCREG1J�
APPLICATION 0- t J 6- I- J- i 1
TEMP POLE
J
f SEC/PH l�
PHONE:
CONTRACTOR/HOMEOWNER: E b T7ROE OUNkA 13VILPHONE: '77(0 —WIAICA
CONTACT PERSONYOR REVIEW COMMENTS: Pam PHONE: 71T 0656
FAX:
ELECTRICIAN: f5 EIA=lc
HVAC: �tla,leJt�llDya►T1y�
EMAIL:
PLUMBER: -ra %PLw 5
GOOD CENTS (Residential only):
ACCESSORY/STORAGE OVING RE -ROOF
ADDITION NEW CONSTRUCTION" SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEVRENOVATION"
DESCRIPTION OF WORK:
PROPOSED USE:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PR%JECT REGISTRATION/ ,VV
#�,E,A�BPRJ
VALUATION: $ t I 15 .3( • O ✓ TOTAL AREA: 6T'HEATED AREA: '7-(t
(Cost of Labor and Materials)
MOPO'UBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
4''
SIZE
[jrWATER TAP:
5a•
SUE
OTHER TAP:
Sim
TEMP POLE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
GARAGE TYPE: SINGLE F__j DOUBLE II TRIPLE
ATTACHED
SIGNATURE OF APPLICANT:
*If proposed work involves new com erci " s ti cade imp
commercial property, building elevations are require .
.............................................
r /o ON7c/al Use Only
_ fi t o - scAe A jE Plans Examiner
_wC?AUV WI H
Zoning Official
to an existing
Cam
jLnents:
YSoNO
G1 t wl ' b I I m al - AX 6�.sk A I
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
Chemical Termiticide Treatment Soil Treatment
1.
O Chemical Termiticide Treatment (Field Applied Wood Treatment)
0 Physical Barriers
t] Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
r
4% PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning 6 Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# g- JSq7
DATE: 5--30 _08
BUILDING ADDRESS:
O h 119.
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
AM O
ll. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
E.
Header sizes indicated on plans
NA/ K
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R.
S.
18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
All walls within 3' of property line to have protected openings.
OK
X0K
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
NA
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
I
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N K
1. Electrical fixtures & switches indicated
2. Smoke detector location(s) indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
7
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window Ll-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N K
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
�� LW_ L.S.,
PL NS EXAMINER
S—�o_"g
DATE
May.28. 2008 2:24PM McClure & Browne Eng/Surveying,
No, 4255 P. 1
�cCLURE'�BROIYNEENG/NEERIN 'UR4E17NG, /NCB 7G08�oae'ce OGrNe, Su/b 103, Co/%ye.ftAw,, revs 77AT- jYF$1 W-d3B
Lot 8 Block 38.dwg
CURVE TABLE
CURVE DELTA
RADIUS LENGTH CHORD, BRG,
C1 119'41'36"
50.00' 101.83' S 12'54'13" E
Lot 7 Lot 6
Now or Formerly Now or Formerly
Lot 5
Now or Formerly
Ed Froehling
Vol.
Builder, Inc_ Ed Froehling Builder, Inc,
7343, Pg. IbI I Vol. 7343, Pg. 101
Ed Froehling Builder, Int.
Vol. 7343, Pg. 101
ti
1 l
N 4576'36" E 107.54'
Z
20' P.U.E.
IT—
m
LotNote_
Building Setback Linea per
1
Block 38
�
City of College Station Unified
pevefopment Ordinonee J2617
....................
Q�
5
Scale: 1~ 30' p9bU�
T
Lot 9
Now or Formerly
Now
p(1 ¢
Na(ri
Ed Builder, Snc.
Vol. 7343, Pg. 101
1 n�OdM
1I� $he�a o'•
aIt
7
r"
r
,N
►'
Prop once
onee
d
Edward Froehling
Remainder 49.35 Acres
I Rep
of
Vol, 424B• Pg, 144
✓'
n ' •
—
32.91
M1
r'
it
0
1 �
n
back/curb
!`• !
HaU (nburg Lane
\f
50' R.D.W. — 27' Pavement
Vo% 7T43 Pg. 101
A
ta' 1L9-
1- t
REScheck Compliance Certificate
2000 IECC
RES check Software Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\1206SB.rck
TITLE: 1101 Harrisonburg Lane
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 05/27/08
DATE OF PLANS: March 25, 2005
PROJECT INFORMATION:
Spec House
Lot 8 Block 38
Shenandoah Phase 14
COMPANY INFORMATION:
Ed Froehling Builder, Inc
NOTES:
Originally 1112 Bracey with kitchen changes
COMPLIANCE: Passes
Maximum UA = 991
Your Home UA = 698
29.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.09
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.09
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
1595
30.0
0.0
56
1031
30.0
0.0
36
445
13.0
0.0
30
38
0.640 24
38 0.400 15
448 13.0 0.0 33
48 0.640 31
Wall 3: Wood Frame, 16" o.c.
445
13.0 0.0
31
Window 3: Metal Frame:Double Pane with Low-E
54
0.640 35
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.09
Door 2: Glass
18
0.580 10
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.81
Wall 4: Wood Frame, 16" o.c.
448
13.0 0.0
36
Window 4: Metal Frame:Double Pane with Low-E
14
0.640 9
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor: 0.10
Wall 5: Wood Frame, 16" o.c.
251
13.0 0.0
17
Window 5: Metal Frame:Double Pane with Low-E
40
0.640 26
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.23
Wall 6: Wood Frame, 16" o.c.
298
13.0 0.0
24
Window 8: Metal Frame:Double Pane with Low-E
2
0.640 1
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.22
Wall 7: Wood Frame, 16" o.c.
251
13.0 0.0
18
Window 7: Metal Frame:Double Pane with Low-E
37
0.640 24
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Wall 8: Wood Frame, 16" o.c.
298
13.0 0.0
23
Window 8: Metal Frame:Double Pane with Low-E
18
0.640 12
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Slab -On -Grade: Unheated
199
0.0
207
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in RES checkVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in
the RES checkInspectio Checklist.
Builder/Designer t / �J Date ' 'Z-7 lV