HomeMy WebLinkAboutRMDL2008-01594BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00001594 Date 6/02/08
Application pin number . . . 696382
Property Address . . . . . . 1005 UNIVERSITY DR E
Property ID: 620400-0221-0030
R #: R79052
Tenant nbr, name . . . . . . FOUNDATION REPAIR
Application type description COMMERCIAL, REMODEL/RENOVATION
Subdivision Name . . . . . . UNIVERSITY PARK #2
Property Use . . . . . . . .
Property Zoning . . . . . . . UNKNOWN
Application valuation . . . . 31800
Owner Contractor
------------------------ ------------------------
PODOG INVESTMENTS, LP ANCHOR PIERS, LLC.
P O BOX 10358 2924 CAIN RD
COLLEGE STATION TX 77842 COLLEGE STATION TX 77845
(979) 219-2774
--- Structure Information 000 000 57 FOUNDATION REPAIR PIERS
Construction Type . . . . . NON-COMBUSTIBLE
Occupancy Type . . . . . . BUSINESS
Other struct info . . . . . IMPACT/PRORATA FEES PAID N/A
HEATED AREA .10
INTERIOR WALL TYPE N/A
SEWER TYPE N/A
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . AC
Permit pin number . 577007
Permit Fee . . . . 170.00 Plan Check Fee .00
Issue Date . . . . 6/02/08 Valuation . . . . 31800
Expiration Date . . 11/29/08
Qty Unit Charge Per Extension
BASE FEE 15.00
31.00 5.0000 THOU BLDG, VAL 1001-50000 155.00
----------------------------------------------------------------------------
Special Notes and Comments
*ALL UTILITIES MUST BE DISCONNECTED BEFORE DEMOLITION
BEGINS. PLUMBING SEWER LINES MUST BE CAPPED TO AVOID STORM
WATER FLOWING INTO LINES. MAINTAIN SAFE JOB SITE AND REMOVE
ALL DEBRI PROMPTLY.
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
-
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00001594 Date 6/02/08
Application pin number . . . 696382
----------------------------------------------------------------------------
Special Notes and Comments
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
PROVIDE SPECIAL INSPECTIONS FOR WELDED AND HIGH -STRENGTH
BOLT STRUCTURAL CONNECTIONS PRIOR TO COVER-UP. THESE
INSPECTIONS MUST BE CONDUCTED BY A LICENSED SPECIAL
INSPECTOR. SUBMIT SPECIAL INSPECTION REPORTS TO OUR
BUILDING DIVISION OFFICE, (979)764-3570, AND SUBMIT A FINAL
SPECIAL INSPECTION REPORT, VERIFYING THAT ANY DEFICIENCIES
FOUND IN PREVIOUS INSPECTION ARE NOW REPAIRED AND HAVE BEEN
RE-INSPECTIONED. SUBMIT ALL SPECIAL INSPECTION REORTS PRIOR
TO CERTIFICATE OF OCCUPANCY.
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
CALL IN FOR RE -ENFORCES STEEL INSPECTION (979)764-3570 PRIOR
TO CONCRETE POUR OF REPAIR PIERS.
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total
Plan Check Total
Grand Total
170.00 170.00 .00 .00
.00 .00 .00 .00
170.00 170.00 .00 .00
----------------------------------------------- -----------------
BUILDING DEPT REPRESENTTATIVE:
APPLICANT:
=IV
1 APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
/9 COLLEGE STATION; TX 77840
CITY or COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planrirrj d Drrubpnrnt Sendai
WWW.CSTX.GOV
ADDRESS/LOCATION: _ /</D.5' i� Sl ?` p2 r"
LOT BLOCK SUBDIVISION
SEGPH
BUSINESS/OWNER NAME: G� ��'�� C'p r
PHONE:
CONTRACTOR/HOMEOWNER: PHONE: 2(q7 —2?? 4
CONTACT PERSON FOR REVIEW COMMENTS:
FAX: EMAIL:
ELECTRICIAN: PLUMBER:
HVAC:
PHONE:
GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION" SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEL/RENOVATION* TENTS
DESCRIPTION OF WORK:
PROPOSED USE:
STRUCTURE USE; 0
HOMEOWNER ASSOC IATI ONIARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ G
VALUATION: $ _ 131, goo TOTAL AREA: HEATED AREA:
(Cast of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
❑ SEWERTAP:
WATER TAP:
OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
SIZE
size
SINGLE a
ATTACHED 0
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE F-1 TRIPLE
IETACHYD r CARPORT F
SIGNATURE OF APPLICANT:
"If proposed work involves new commercial con truction or facade i ements/renovations to an existing
cOMnle ial property, building elevations are required.
OfrGial Use O
`2" N nts:
YES NO
Plans Examiner Zoning Official
I• -d 9CZ00696L6
d I.O:tiO 80 8Z AeW
rr�1'-3A2A0T-0r$ :23 AH ANCHOR PIER LLC 1 r F+1
111110%11111924 Cain Road
College Station, TX 77845
Office: (979) 690-2020 Onto: Oct'-J 1
Fax: (970) 990.0235 AGREEMENT
Anchor Piers LLC, called Contraotor, and 'f U 5, Lust l � e� T , Qr r agree that the sum
of 0 00 �r , to be paid as follows: plots are l7ourod, balance on oomplotlon,
Contraotor will furnish labor, equipment and meterlara to perform the following described work to the horolnafter descrbed
building or structure located at: �00� I�IUJd ffT . Z Story .jLvm, Struoture
Phan0 jbt 6 -)(7d'
—Z
1. The work shell consist of the installation o1L,_ -wltd nine Inch,
V4 rado`+�> oN� piers dlameter shans drilled to 8" to IX'. water
Iftle rocks ttndlor men placed olojoute permitting. The buttom of the eheftwill have a bell footing of 20 Inches In
diameter, unlees rock is encountered.
2. Contractor assumes no responsibility for any under Blab plumbing. It may currently be cracked, broKon, detedo-
ratod or may do so In the leveling prows&. Any repalrv, if raquired are the sole responsibility of rho owner.
3. Job site will be clean of all excess dirt and material,
4. Contractor w0I carry all required Insuranoo,
5. When Inside Piero are called for, contractor will patch floors. Patches will be mods with concrete to wooden floor
level. Carpet will NOT be stretched.
S. Whero surfaces such as concrete floors or patios are broken In order to Install plore, Contractor will patch such
area. The patches, however, will not match he color or texture of the original material, Special surface such Qo
Flagstone, Spanish Tlls, Brick or other such special matorlals Mil be restored at a coat In adcUtlon to pier Installs.
lion.
7. In foundation leveling, condltlone mlghl appear when work is begun that were not visible when estimate was
submitted, such as, Inaumclent rolnforcing steel In concrete slab, andlor other original foundation structural
deflolency. In such cases the guarantee becoman Invalid. -
8. 6PECiALPROVISIONS; No Subcontractors. ea;- f`Xr5 rT;,� du��yr,
9. LfFETI6ME SERVICE /AGREEMENT; it any raising is necessary due to settling during the first five years (rum date
of completion of the job, Contractor will ro•rafae the ee ed ard# without cost to the OWNER. For additional
years, servicing, If required, will be done at the rate o °'per adju3ted pier, labor and materials Included,
Plus or minus the U.S. Consumer Price Index each year. This service agreement applies only to the =ZZ piers
installed by Contractor.
THIS AGREEMENT TRANSFERABLE TO NEW OWNERS. NOTIFICATION MUST BE TENDERED IN WRITING
WITHIN 30 DAYS OF OWNERSHIP
It 18 underatood agreed that In order to Perform the atrovo described work it Is possible that sheotrock, wal►paper, or other
rigid material may crack. Therefore, the above figvre does not Include any rodeovrating, repAlring, electrical work or the
replacement of any material not ottlled for In this Agreement, Contractor upon fequest from owner, will transplant plants
and shnrb8 oOf RUCIting operations, and replace same, ay Iv y
11 Is Understood and agreed that Contractor will furnish all the labor, equipment and material and will perform all necessary
work In conneotlon with this job, In a good workmanlike manner.
Tho Owner may order extra work to be Cone not contemplated by the contract. In which event, a separate Agreement for
such work shall be entered between the Owner and tho Contractor. No oral repreeentatlon made by anyone can change
or modify this Agreement, This Agreement in order to be bingln by both parties, must be signed In the space provided
below, and'the original copy returned to this office within & — days from the date shown above.
Owner
1.
Anchor Piers LLG
I'd S£200696L6:01
Z-d 9£Z00696L6
92S1S216L6 09 06tii` 9tw"A £Z:80 8002-92-AUW
d60:t,o g0 gZ AeW
rya' - _ =`"
:c otxzsc�,�,$i�s�
11
PIER FOUNDATION DETAILS
FOR REPAIR ONLY TO DAMAGED FOUNDATIONS WHERE SPECIFICALLY DESIGNATED
1 EXISTING SLAB ABEAM
GRADE
6.114 RODS
I EACH WAY
ALL CONCRETE
TO iE b BACK
W/ 1.1ir ROCK
ii
SHIM&GROUT
,i-- all x 9" x 12"
SOLID CONC.
BLOCKS *'
r
2-0"
SIDE VIEW
t d 99Z00696Z6
STABLE
CLAY
W
K O
O �
¢ ¢
IL 0
K 4
J
(�
y 2
O 3c
Lu
O w
4C to
t O
O
F p
1"MIN a" 1"MIN.
JACK
SPACE
_ .,-- t t
POUR CAP i
• FOOTING AT
THE SAME
TIME
4
2-2"
I
� 3-#4VERT.
L W/ N2 TIES i 14"O.C.
t 9" D".
Tj
20" OIAM.
FRONT VIEW
d 60:t0 90 9Z AeN