PREPARED 6/24/08, 12:06:28 INSPECTION TICKET PAGE 11
City of College Station . INSPECTOR: BUILDING INSPECTOR DATE 6/24/08
------------------------------------------------------------------------------------------------
ADDRESS . .
CONTRACTOR
OWNER
PARCEL .
APPL NUMBER:
2612 ALEXANDER VALLEY CT
STYLECRAFT BUILDERS
SUBDIV: SONOMA PH 1
PHONE (979) 690-1222
PHONE
578700-0120-0070
08-00000513 RESIDENTIAL, 1 UNIT DETACHED NEW
-------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/01/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00
4/01/08 AP April 1, 2008 8:09:11 AM kwolfe.
April 1, 2008 4:29:44 PM kwolfe.
STRINGS UP, SLAB GROUND INSTALLED
B115 01 4/30/08 RH BLDG, FRAMING TIME: 17:00
4/30/08 AE April 28, 2008 4:45:08 PM bcaldwell.
04/30/2008 10:27 AM RH PDA
Nails needed on strap for garage at every joist. X- brace
on wall needs min: 3 16d nails at top and bottom plates.
Draft stop chase in kitchen properly by insulation.
B130 01 5/01/08 OC BLDG, INSULATION TIME: 17:00
5/01/08 AP May 1, 2008 10:04:50 AM glsouth.
B132 01 5/02/08 BI BLDG, SHEETROCK FASTENER TIME: 17:00
5/02/08 CA May,2, 2008 3:45:07 PM malford.
May 2, 2008 3:57:56 PM acarter.
Wrong inspection.
B132 02 5/06/08 BB BLDG, SHEETROCK FASTENER TIME: 17:00
5/06/08 AE May 6, 2008 8:52:13 AM glsouth.
05/06/2008 04:05 PM BB PDA
Nails needed between gaps at top and bottom.
B125 01 6/24/08 B BLDG, FINAL TIME: 17:00
June 24, 2008 8:23:45 AM glsouth.
-------------------------------------- COMMENTS AND NOTES------------------------------------
Apr.23. 2008-10:14AM--. Stylecraft Builders, Inc.
"Shielding & Protecting
Homes Against Pests"
No, 9578 ' P. 7
Renewable 5 Year v9,51-3
Subterranean
Termite Retreatment
Agreement
(Does not cover any other species of Termites)
This /agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph).
CustAer Name 4 Date Billing Name if different
Street Address of treated structure
Billing Address if different
City State Zip Code City
Home.Phone Work Phone
Type of Treatment Partial Bait iPre-Treat
State Zip Code
Initial Termite Cost
Additional Renewals Paid
Other
Tax
Treatment.for:Prevention Control of Subterranean Cash Check# Total
Termites Payment
Notes: Balance
$
S
Credit Card:
Type Exp. Date Card Number
5 Ye r Snbte n n Te ttP Retreatm n# f:narant .; RP Lee Termite and Pest Control will retreat the structure for Subterranean
Termites at no cost to the customer, if an infestation of Subterranean Termites is found, as long as the original treatment is paid in fall
and the castontcr is current on their yearly Mewals. This Agreement will expire in one (1) year unless the customer elects to pay
the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termite
and Pest Control may approve additional warranty years after the five (5) years with an additional increase in the yearly warranty fee.
The guarantee does not cover any damages to the structure or contents of the customer. The customer agrees to control all eondusive
conditions that may cause reinfestation, if the structure is modified, added on to, altered, or if the soil treatment around the struetttre
is removed the customer must contact RP Lee Termite and Pest Control and pay for additional treatment in order to keep the guarantee
in effect If the customer does not pay for additional treatment the retreatment guarantee can be cancelled. ou
Renewal Fee: Customer may elect to renew the retrcatmcnt guarantee for additional years. The renewal fee is $ ✓2? plus tax.
The renewal fee is due on or before the annual anniversary date or paid S / plus tax every third (3) month with inspection.
Maintaining the Guarantee: The customer agrees to correct all condusivc conditions, at owner's expense, as they exist or as they
occur in the future in order for the guarantee not to be cancelled. Customer will make the structure available for inspections and
treatments as requested by RP Lee Termite and Pest Control.
$elrtsagdAn RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times RP Lee Termite
and Pcst Control deems necessary. RP Lee Terroite and Pest Control.reeotnmeods that the customer call and setup an annual inspec-
tion at the time of customers yearly renewal.
Trapsfer: This agreement may be transferred to a new owner with thc-paymmt of a transfer fee of S copy of the wood
Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest Control.
Tblc t . n . n T rmit . R . s+fm .nt .narontee does not prevent and is not Intended to control doer forms of Termites
{Dr3�oQd�Formn etc.1. Wood 7or1nQ_$eetjeg. CementerAat. Cea rtenter_Bee_s. Wood Rot, Fungus, Decay, or,Any other
wood destroying insects or organisms.
Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties
above agree. to participate in mediation through and in accordance with the commercial mediation rules ofthe American Arbitration
Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final,
binding, non -appealable and maybe entered and enforced in any court having jurisdiction in accordance with the Fcdcral Arbitration
Act.
Umfta0m 2f_LiahMM Laodseaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled
up in certain areas around the home, drill holes may need to be .made in floor coverings such as tile or linoleum or in cabinets next
to pipe atcas, and holes may need to be cut in walls. Customer agrees not to hold RP Lee Termite and Pest Control liable for these
damages, or treatment techniques, or other damages that may occur during treatment.
Agreement: This Agreement shall be the entire agreement between customer and RP LccTcrmitc and Pest Control. If any part of
this agreement is found to be invalid it shall not affect the validity of any other part of the Agreement.
We are dcensed_bv t Ctructnral Peat Control Board - 331:raadalao . Suite 1-530
Austin, TX 78701 512-305.2.40
RP Lee Termitex Pest Control Cert. Apt# Customer 91guaturc Date
Apr, 23, 2008 10:14AM Stylecraft Builders, Inc, No. 9578 P. 6
New Construction Subterranean Termite °W "pp'°"°' Na' (elp. 1`0IJ 1/2005)�:�'°w! soli Treatment Rocord
THS toast 19_ cor iolixod lho 11+; Od Pont Coelyd Cam nY----
i�rbcl0 rgfla np Lurwo tar des tolod)Itn d ittforiaw.0 la mt malod to 8voraao 113 NFUIlu Far ratpontA+ Dtdudirip Uio Lrio'iui rvviwoi d�a►uocticts. 1u2�ChMy
O+ ip data eett<re6, t?A+tt c9 gild r+lak wiln 1110 ttata ntA+nud. and o01t1p1 MO and rvAoftg rite COW10A m 1AIwW t 'RIF Wanidlltrn b iri011=41ry aricl is
ragUUed 10 dAO tx uoftta. HUD rrla)' M COW t f; 5durnw W4 ar4 YOUamnot rpptJlmd Td crrrultom tTlJu form, urtla to R u�ttays a cwrunt/ raid CUB conaot
nun>ixsc.
C*:Son 24 GFA 2200, a'od(b)(3) tdgd ae that dte skew for HUD Inaurod atructuroa mvat Lv hug ur iom1ko habrtds. Tb13 lnla Rion 040dw food= 919 tr'tder 10
Cal* @tut An a4Ktaod Pout C gnol wtnl+a y pell.rrnod eA miluhod ltisaWwl tar 1o.,W . arts owl Div W Wcr j,%wat9= dla troollid MW apSatst IntOCMV-1w
tnle year. buddors, post aoauw ODtlrprtni- mwvgo condom, irarnatsrl' .% and HL''Ll as a row'd vt UOAMMI trr al,otiliu lrum= wib u+w dw'cdinil> An, CdLvt:C
Tito itlrsr4rkin is nit cmiidrrracf tu1rdar"
ThAlopartis&9MI Wfor1ntorrtmWnatPuWMu3tothohWWNronprbp=od(now)tomitucu00%cwosumae::ollVAal+ontforpr-vuntionQvubiorranpan
Ieunlltb inroetat:m 1e cpeolnod by Via b:itldor, axelrnaol, w tagviruJ by thu tontlur, iWO1101, FKA. or VA.
All tsmuaCts tot t orvicoo aro 14twoor.:110 Nosl Gonuot Operotor and buUdar, unlos- ttatad athoriviae.
SaaWn 1: Genera} irlfotmatton (Tre116115 Cc+)panr 11110fcnali9ct)
Compan}•NQrtla ���.i�• � �/i �i.9.y/T� r+• �GSY ��,,,/..._. pt/�
Cgmpany Addrilba _ -- r • �" . y �/ �" '� "'. SWIu / �. Dp
Cartlpmny dutlnau Lgrutco T1a aP Gamyatiy PtiCnu No.
FKANA Casa Nc. (it any)
vaoiton 21 Guudor )nfixM41fan
Company Namo .^ phone Na
. $actiaD �: Property NclartttaUtm � � �Z ��CXQv ate'
Loz tt(act of Sttucftxa (a) Tcoolod (Shoot ALUM Zr L0931 Deacrlp6on. City, ftsta WO A)) 77a 5�5
T}Ste o1 COrwlruellon (Mara Ulan ww Lwu twy bo vhocl.00) Ld_J Stab r--' t}aaornnnt � Crawt
Appraldmato Doptr, of Footing: Qu.'clde bizide Typo r+f Fill .Y
3174on 4. Trcalamrd 11110nn41ett
Dato(s) of Tivatmont(c)
Brand flerrte at ProdUc*,)--
EPA Aootmdon No.
Approxlmale Final 3JA1t SatuUan •� 5v q
Approldmato slz4 01 TroatMont Aroa Sq.1L ^ LJnoar ft 3 z 33 Llrcar R, a1 Masonry Vo'•do
Approxlmato TuW Wong of WWan AWivd G'a'
Was treatrrlurg cnmtioted an aztttriWY) M Yes ��•• No
6wvlcoAgroomontAvallrhlv7 O yas Om
Nets: $oM0 e4o lawa roquuo adMoo agroements to Lo isauod Thio fain Ovoo nut pruunlpt stag la1r.
Atino-rovo (tat)
Nions M APPIIcal0i fs)
CwU r&Ucrl No. Vf rogWod by 5tola low)
Vito opplleator has used a prodWt In "wrdallce wth U10 product Ipbal ar4 sluto rcquirarinnm. All troatroom rn2tdru1-i :Yid nlolho& USod Campl} wkh
mate and fodorW riyutAUons.
Authodzedfrtor+otwu
�VOrgltt HCiJwilpfD".NVJUtplso�tlMY:tlndraato�+M�bt CFeNr�rv,�M �+�ahMtuVnlnnl.•wV•+rti+�l �.�•+ni,u: 1EU.;•.G. I'7nt Iaf014�7�:f1U:.J:.:1T'^- V+)?)!
Fo+m NACA-9" may &9F W urod Main 1SUr�tIpCA-STil II (Ua/Yc03)
Apr, 23. 2008 10:15AM Stylecraft Builders, Inc. No, 9578 P. 8
SUBTERRANEAN TERMITE, PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATE
Licensed and reguiated under the Texas Structural Pest Control Act
RP LEE TERMITE & PEST CONTROL
PO Box 9423 - College Station, TX 77842 - (972) 690.8622 - TPCL #11486
:--CUSTOMER INFO TIpN: T 1.....
Name: ly7e .4 F7�1'44 H� Phone #1 Phone #2:
Address:Al? AL 4.ut e n City; r , 5 State: 7r/ Zip Code: 7704'1/5 j
Location to be Treated,
For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards.
Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the hew. Review the consumer information sheet for further informatlon. If you
have any questions, contact the p9st congol company or the Texas Structural Pest Control Board, P.O. Box 1927. Austin, TX 78767-1927. Telephone number (512) 305.8250.
Before conducting a termite pfewstruction treatment, the company will present a complete diagram of the structure including construction decals. When construction prevents performance of a full
treatment in accordance with a bid for full treatment, any change to a partial treatment by the company providing the treatment will be permitted if the owner of the structure or the person in charge of
the construction and the certified applicator for the pest coritrel company slgn a statement attesting to the construction conditions. The agreement must be attached to the contract with an amended
diagram showing the exact areas to be treated. Copies must be sent to the owner of the property within seven days of the application.
notes: 1,46,9",4,ve
�1�7 RC C CJ�/JUS��
3,2y
CONSTRUCTION DETAILS:
/ I
Type of treatment proposed: (check all that apply): 0 Full 5 Partial i-XWood ❑ Bait 13 Commercial C j0ngle Family
Total square feet to be tr led: _�. Total linear feet to be treated: 313 . Approximate measurements of structures) to be treated:
A label of 7u Y; Cr:; t termiroide(s) is attached. The percentage of the tarmiiicide(s) to be applied at this location is y'a,
Estimated amount of termltldde to be applied: aallon(s).
THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED ON BACK (SPCEID-4). THE BOARD APPROVED SUBTERRANEAN TERMITE
PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUcnON TREATMENT
SERVICE. Complete details of warranty (if any) including time period of warranty, renewal options and cost, and obligations of the contracting parties is attached. If the warranty does not
include the entire structure treated, the areas included in the warranty are (speelfy);
A consumer'nformation sheet is also attached.
V2)t e �f-lS.f 6 /Je'� jlle'� s a�v -I
Signature of qkbr Technician Printed Name Date SignSign ruCustomer Verifying Receipt of This Document Data
m d a arvR 4-0 01=MT white copy • Smite Providor Yellow Copy -Customer Form Oeam,m e m Pued by Snvneltm 0v=mta= i-m&7m4Eer3. =4 flCaw
Service Treatment Invoice
Route: Map Code.
Stxrt'flute. amlpm Finish 111ne: amlpm
Type of Service: lulia Regular Follow Up One Time Charity
Service Address
Name: 1r4 is T Z TO N 5
Address: e,21PlZ A1errz;4-,y�)rr'-
City: e , 5 TX -'7 & L/5-
Phone:
I �
.�.Y��
y �tli._GrL:pZ.
V.1iil"Ir. F`E1!;'d t1jr-J 10�
Date.
Appoint. Time: Ar amlpm
Frequency: M BM Q S Y a
Structure: Slab Crawl P/B Combo 17
Pets.- Dog(s) Cat(s) Bird(s) Fish /:1/&/VC_ W
Cost of Service S _ l'V3 0 V
Tax S
Total Due S
Payment $�_
Balance $
PEST PROBLEMS: �fc��%rde-'gVA4e 'ul DIRECTIONS / INSTRUCTIONS:
Billing:
EQUIP. METH. LOCATIONS) PRODUCT
WOOD DESTROYING INSECTS
MICE, RODENTS„ RATS, MONITORS
QTY
TARGET PEST(S)
k. i dam-` o
Payment by. -
Cash Q o
Check rJ #
Credit Card Q
PAYMENT DUE
UPON RECEIPT
'Ile raider SC-Fiprwril .06%a Subtrrrascen Termites, Ants Sfxc ofMnk Posted
Tcrmidor®OW-Mpnonll.06% j SobhxraaennTermites SreeofTank Ported
[iezacareDiaodiumlkhboratcTetra➢yda[e59°i6-7, C 4M/ SublerreeemVFornosanfDryvtred Termite4,CarpcntcrAnts,Beelks, postal
Invader HP1I-Baygu■ M
Demos wr-Cyano*Phenoxyphenyl
DLnclhyeylryelepropssecorboxylste 1%
Tempo Ultra WP-Cy lathrtn .025% (Real)
(gm surface spray, spot, nisi, crack & crevice)
Thislar EZBiferthriu .2%
hlaxiorcrHydramethylon 1'/-2.15%
Cyklck CS Cylluthrin .Odx
Phantom .VA
Tengard-Permuthrin .5%
Suspend SC-Defloseterin 4.75% (REST)
Nyguard-Methyletsoxy 13% (RDS'l)
Excite R Pymbrin A3ye
Fumeac.-Bromethalin .01%
Unit Station-LargelSmall Glue Boards
Pro-Contrul Plus Pyrethrins.50%
:1lasterllne Bifmthrin A6%
CurpenterAnts, Spiders, Qrickels, MdUpedes, Beetles, Termttes,
Cockroaches, Millipedes, Smsbap. Fllahllcks, Mosquiloa. Pillbugs,
Silrcrtish. Dora. Ants, Carpnmcr Arft Scorpions. Spidery.
Ants (Except Pharouh), Cockroaches, Crickets, Earwigs, lgilhpedes, Flies, Frolt Flies, Becties,
Piflbuga,Silverfish, Splders.Gnats, Hornels. Wasps, Veflow3ackets.
AnM Ceetipcdes, Cockroaches. Crkketa. Grasshoppem ScorpionsTicks, Silverfish, Spiders.
PharaolrActs, Crickets,Carpenter Ants Lg. Reaches, VarletyufAnta.
Spiders, Scorpions, An% Carpereler Ants, Carpenter Bees, Roaches, Crickets, Sitverlish.
Miaro➢ Ants, Variety of Ants, Roaches.
Fleas, 7lclw6 Acts, Cenlipedes, Carpenter Ants, Bees, Warps, Carpenter Brea, Cockroaches,
Crickets, Flies, EarwW, hlillipedas, HeOtes, PiObugs.
Fleas, Bees, BeWes, Rcaches,Crkkets,Lie% FIks,ScwVkoes,'11chs, Wasps.
IGR-Growdi Regaiator-Fleas, Roachca,Crkkels, Flying Insects, Stored Product PON.
Fkaa
Mice, Rodcnts, ]fats.
llliee, kodads, Rats, Beg Umilore.
Houseflies, Mosgsiles, lt[olhs, Fleas, %Vaaps, llornets,'lYrks, Cockroaches.
Spiders, Ards, koaches, Silverfisb, Fansigs, Fleas, Scorpions
F&uiomenilA-Compmesad Sprayer P-Power Sprayer H-Bait Dispenser US -Bait Station BT-Bait Trap D-Aerosol Can G-Girls Board H-Hand Duster S Spreader F-rogser FM -Fortner AC Actisol unit Other
LPSgtlon1:1-i(itclum 2-Batb(s) 3-Bedrooms 4-Dining Room S-U(ilily 6-Storage 7-Coaunon Areas S-Gatagc 9-Perimelcr ofStmcture 16-Attic 11 Nard 12-Under Home MV#isrehmm 14-Oiiicc 1SExposcd Wood 2' up from Slab Other
bletked of3)3#Iments: CC -Crack & Crevice SS -Sub -Slab Injm-tion VT -Void Treatment BP -Bait Placement BS-Broadcast Spray PB-Perimeter Barrier 13 13rick Vlenire NVT-Wood Treatment
PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried.
Licenced by the Texas Department
-of Agriculture Structural Pest Control Service - P.O. Box 12847 • Austin, TX 78711 •512-3054250
SERVICE TECHNICIAN: �~ G�-� CUSTOMER SIGNATURE: 41�e11/ Ii/r�e S e,ti 11 le DATE:
Please review the Customer Information on the other eide of liavoiee
P.O. Box 9423 • College Station, TX 77842 • (979) 690-8622 • Fax (979) 690-8840
z
0
i
i
2FRONT ELEVATION B
SCALE: 3116'=1'-0'
Y
SHEET INDEX
COVER SHEET
G-1
SITE PLAN
C-1
FLATWORK DETAILS
C-2
FOUNDATION PLAN
S-1
DIMENSION PLAN
S-2
FRAMING PLAN
S-3
ROOF FRAMING PLAN
S-4
DECKING LAYOUT
S-5
FRAMING DETAILS
S-6
FLOOR PLAN
A-1
DETAILS
A-2
ELEVATIONS
A-3
CABINET LAYOUT
A-4
FLOORING PLAN
A-5
ELECTRICAL PLAN
E-1
2612 ALEXANDER VALLEY CT.
SONOMA
LOT - 7
BLOCK- 2
PHASE - 1
VERSION
#
DATE
REVISION
O
8/1 C
MASTER APPROVED
1
11/13/06
SECOND MASTER SINK OPTION ADDED
2
11H3lo6
CABINETS CHANGED: MASTER BATH, KITCHEN
3
1/10/07
CHANGED 2X6 CEILING JOISTS TO #3 YELLOW PINE
SHEET:
G-1
0
0
00
0
z
H
a
w
w
N
r4
N
a
Y
ki
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLAGE STATION, TX '77840
`PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00000513 Date 2/25/08
Application pin number . . . 626359
Property Address . . . . . . 2612 ALEXANDER VALLEY CT
Property ID: 578700-0120-0070
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . SONOMA PH 1
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . SINGLE FAMILY CLUSTER DEV
Application valuation . . . . 78210
Owner
------------------------
Contractor
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
MASONRY
.IMPACT/PRORATA FEES PAID
DUE
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1185.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
-------------------------------------------
TRAFFIC IMPACT ANAL (TAZ)
427.00
Permit . . . . . .
--------------------------------
BUILDING PERMIT 7.
Additional desc . .
GS
Permit pin number .
554170
Permit Fee . . . .
376.00 Plan Check Fee
.00
Issue Date . . . .
2/25/08 Valuation . .
. . 78210
Expiration Date . .
8/23/08
Qty Unit Charge Per Extension
BASE FEE 260.00
29.00 4.0000 THOU BLDG, VAL 50001-100000 116.00
------------------------='---------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing Engineered Methods
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
-
--------------- ----- ------------------------ ----- --- -- -----------
BUILDING DEP//T.' REPRESENTATIVE:
APPLICANT: �L, _. —
BUILDING PERMIT
` CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00000513 Date 2/25/08
Application pin number . . . 626359
----------------------------------------------------------------------------
Special Notes and Comments
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*Engineered Bracing Methods Used To Meet Windbracing
Requirements.
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE l
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
*PLATFORM FOR MECHANICAL EQUIPMENT 3ANDOR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC TION -
- �- -------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX '7840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00000513 Date 2/25/08
Application pin number . . . 626359
----------------------------------------------------------------------------
Special Notes and Comments
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 150W the Values Shall be
R-13 and R-30, above 150W the Ceiling Insulation is Increased
to R-38.
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 1511 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFI
-------------
IENT OF ALL GLAZED
------------------------------�-- ---• -
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 08-00000513 Date
2/25/08
Application pin number . . . 626359
----------------------------------------------------------------------------
Special Notes and Comments
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 200-. TO 3001 A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
*GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------
------------------------------
Permit Fee Total 376.00 376.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1126.00 1126.00 .00
.00
--------------------- ------ ---- -- --•-----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: a-Irm_/�z'
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number .
Application pin number
. . . 08-00000513
. . . 626359
Page 5
Date 2/25/08
--------------------- - - - - -- ----- - - --.- -------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:,x2
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property. Zoning . . . . .
Application valuation . . . .
08-00000514 Date
707502
2612 ALEXANDER VALLEY CT
578700-0120-0070
TEMP POLE
SONOMA PH 1
RESIDENTIAL
SINGLE FAMILY CLUSTER DEV
0
2/25/08
Owner
------------------------
Contractor
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit pin number
. 554196
Permit Fee . . .
. 20.00
Issue Date . . .
----------------------------------------------------------------------------
. 2/25/08
Valuation . . . .
0
Other Fees . . .
----------------------------------------------------------------------------
. . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary
Charged
Paid Credited
Due
-----------------
Permit Fee Total
----------
20.00
------------------------------
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-
APPLICANT: ���
(*//q"' APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning & Development Seracer
WWW.CSTX.GOV
/G'-, office Use Onty �7 ,
DATE: � ` I_O�RCc RREEG I J�
APPLICATION # O� 45t1 >
TEMP POLE # l`/� r ✓ H
ADDRESS/LOCATION: &A?e ALCE (APQC-P. V kL1EY
LOT —1 /BLOCK 2- SUBDIVISION e7WOMk\ SEC/PH I r
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext. 120
FAX: 690-0348
ELECTRICIAN: Brazos Valley Electric
EMAIL: ewivagg(aD-stylecraft-builders.com
PLUMBER: Bass Plumbing
/\,V0 HVAC: Control Temp GOOD CENTS (Residential only): No
O C ACCESSORY/STORAGE LOCATION
ADDITION MOVING
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION
DUPLEX (Landscape Plans) REMODEURENOVATION*
00
DESCRIPTION OF WORK: Conventional Framinq
PROPOSED USE: Single Family Residence
RE -ROOF
SHELL ONLY
SLAB ONLY
SWIMMING POOL
TENT/CANOPY
WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS ❑ ENGINEERED gL
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ 113 .1210 TOTAL AREA: i62_ 7 HEATED AREA: U&S
(Cost of Labor and Materials)
j„ �X PUBLIC SEWER
I `(� SEPTIC/TREATMENT SYSTEM
IS
�X SEWER TAP: 4"
SIZE
- • � bj � • a.o„
N4
QX WATER TAP: 3/a" EXTERIOR WALL TMWM pn,,qVr Masonry
SIZE
WAM
OTHER TAP: FOUNDATION TYP IN 'b oXNde
SIZEaxibmw
Q �O TEMP POLE ROOF TYPE:
1 • S'GARAGE TYPE: SINGLE DOUBLE TRIPLE
• ATTACHED �X D ED <OR
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction oe cade infirm
commercial property, building elevations are required.
Official Use Only
1:X Z —pf 0 (b
Plans Examiner
All M-
lk",ram g tow �q
Zoning Official
CC ents:
/YESIor NO
Composition
0
'D For Stylecraft
ovations to an existing
Fire Marshall
(CLJ
Energy Code Compliance Information
% Glazing of exterior walls
11 %
Insulation R value of exterior walls
R13
Insulation R value of ceiling 1 (flat areas)
R30
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19
Glazing SHGC (Solar Heat Gain Coefficient)
.35
Glazing U-Factor
.53
R value of ductwork
R6
A/C SEER Rating
13
i
Protection Against Subterranean Termites
7
❑ Chemical Termiticide Treatment (Soil Treatment)
Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
r
PLAN REVIEW
(*f/"" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning dDevelopment Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# _ 3
DATE:
BUILDING ADDRESS: / 141 0!�LN4
I. Foundation Requirements- Minimum City Foundation Standards
N
A. Concrete minimum compression strength of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F. Protection Method used for Termites.
G. Wood foundation details indicated
N K
11. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E. Header sizes indicated on plans
NA/
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O. Roof covering
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
W10K
OK
CITY OF COLLEGE STATION
Planning d Development Servicef
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d Development Service;
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window LI-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
dle
Street Ordinance Requirements
N K
Maximum drive width for residence is 25' combined for circular and 12' minimum for
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
S EXAMrNER DATE
0 REScheck Software Version 3.7.3
8/"' Compliance Certificate
Project Title: Plan # 1185-SN
Report Date: 02/18/08
Data filename: S:\ACAD\Archived\Old REScheck\1185_2612 Alexander Valley.cck
Energy Code: 2003 IECC
Location: Bryan (Brazos), Texas
Construction Type: Single Family
Glazing Area Percentage: 11%
Heating Degree Days: 1788
Construction Site:
Permit Date: 2/18/08
Owner/Agent:
Designer/Contractor:
Permit #
Permit Date
Compliance: Passes Maximum UA: 455 Your Home UA: 386 —> 15.2% Better Than Code (UA)
Maximum SHGC: 0.40 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
Ceiling 2: Cathedral Ceiling (no attic):
Wall 1: Wood Frame, 16" o.c.:
Window 1: Metal Frame, Double Pane with Low-E:
SHGC: 0.40
Door 1: Solid:
Door 2: Glass:
SHGC: 0.40
Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0'
Air Conditioner 2: Electric Central Air: 13 SEER
Furnace 2: Forced Hot Air: 80 AFUE
999 30.0
0.0
35
186 19.0
0.0
10
1192 13.0
0.0
84
112
0.670
75
38
0.500
19
18
0.440
8
149
0.0
155
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 3.7.3 and to comply with the nda ry irem is listed in the REScheck Inspection Checklist.
S�Yt Ect 2,1181D5
Builder/Designer Company Name Date
Project Notes:
Previously saved project information:
Porras
2612 Alexander Valley
COLLEGE STATION
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
Plan # 1185-SN Page 1 of 1