Loading...
HomeMy WebLinkAboutCNEW2008-0050808�508 M 21 o Date 2 Permit # C2 Project Name Yt 7 1/(/i�ri`o��ti COMMERCIAL CO Planning (Lindsay Boyer, Jennifer Prochazka, Jennifer Reeves, Crissy Hard, Jason Schubert, Grant Wencel, Molly Hitchcock) --" Bridgette George Development Engineers (Alan Gibbs, Josh Norton, Carol Cotter) City Engineer (Bob Mosley, Jerry Jones, John Logan, Robert Bumpurs, William Ethridge) Environmental Services (Eaphrame Thomas, James Boykin, Pete Garcia) Fire Department (Eric Hutt, Eric Dotson Jerry Drainage (Donnie Willis) Public Works - Sanitation (Wally Urrutia) 0 `'\ Electrical Services (Tony Michalsky) Water/Wastewater Services (Joe Mike Garcia, Paul Schoenfeld, Mitchell Carson) Miscellaneous Notes f--+ mot a City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . Expiration Date Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning Owner . . . . 12/02/08 12/16/08 005001-1016-0000 400 HARVEY MITCHELL PKWY S 400 COLLEGE STATION TX 77840 J E SCOTT (ICL) A005001 J E SCOTT (ICL), TRACT 16 CS, ACRES 9.63 GENERAL COMMERCIAL TITAN VALLEY PARK, LTD Contractor . . . . . . CPFPCS MGMT Application number 08-00000508 000 000 Description of Work COMMERCIAL, OTHER Construction type . NON-COMBUSTIBLE Occupancy type . . . . BUSINESS Flood Zone . . . . . Special conditions 27. a e 2. Pay $27.00 Reinspec„tion Fee (Electrical). Approved . . . . . . . ng Off icia VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING POTENTIAL Austin McAllen Mexico 901 South Mopac Bldg, V, Suite 110 Austin, Texas 78746 Phone: 512 3281010 Fax: 512 328 3003 wwwwtagae.com TRANSMITTAL Date: July 15, 2008 To: City of College Station From: Lisa Fain 1101 Texas Avenue College Station, Texas 77840 Attn: Ben McCarty Project No: 7114.1 Re: Starvision cc: David Carson, David Hillman Valley Park Copies Date I Description 2 07.02.08 1 Revised Permit Review Documents ❑ For Approval ❑ For Your Use ❑ As Requested ® For Review and Comment Remarks: The enclosed Architectural and Plumbing drawings are for the revised permit for Starvision Valley Park. The original application number is (08-508). The Mechanical and Electrical are now design build and those drawings will be sent to you under separate cover. Please let me know if you have any questions or if you need anything further from me. Thank You, Lisa Fain .PREPARED 12/01/08, 11:59:32 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/01/08 ------------------------------------------------------------------------------------------------ ADDRESS 400 HARVEY MITCHELL PKWY S 400 SUBDIV: J E SCOTT (ICL) TENANT, NBR: STARVISION CONTRACTOR CPFPCS MGMT PHONE OWNER TITAN VALLEY PARK, LTD PHONE PARCEL 005001-1016-0000 APPL NUMBER: 08-00000508 COMMERCIAL, OTHER ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B120 01 7/28/08 DS BLDG, FRAMING -PARTIAL TIME: 17:00 7/28/08 AP July 28, 2008 10:15:55 AM acarter. �1 exterior walls only. B130 01 8/07/08 DS BLDG, INSULATION TIME: 17:00 8/07/08 AP (/ B130 02 8/14/08 DS BLDG, INSULATION TIME: 17:00 8/14/08 CA August 14, 2008 1:45:55 PM bboerboom. For on bathroom walls. B120 02 8/21/08 DS BLDG, FRAMING -PARTIAL TIME: 17:00 8/22/08 AP August 21, 2008 4:22:01 PM glsouth. B115 01 8/28/08 DS BLDG, FRAMING TIME: 17:00 9/02/08 AP August 28, 2008 8:38:29 AM glsouth. B135 01 10/16/08 OC BLDG, CEILING COVER UP TIME: 17:00 10/16/08 AP October 15, 2008 2:23:07 PM glsouth. B125 01 11/24/08 DS BLDG, FINAL TIME: 17:00 11/26/08 CA November 24, 2008 12:12:56 PM kgreen. B125 02 12/01/08 I BLDG, FINAL TIME: 17:00 -, December 1, 2008 9:51:11 AM ccourt. ------------------------ -------- COMMENTS AND NOTES-------------------------------------- Benjamin McCarty -Re: Calling for CO for 400 Harvey Mitchell Pk wy 400 Page 1 From: Rodney Harris To: Alan Gibbs; Benjamin McCarty; Brenda Godfrey; Brent Read; Bridgette George; Carol Cotter; Chris Haver; Christina Court; Cindy Dillard; Crissy Hartl; Donnie Willis; Doug Ervin; Eaphrame Thomas; Eric Dotson; Eric Hurt; Erika Bridges; Gina Southerland; Israel Koite; James Boykin; Jason Schubert; Jennifer Prochazka; Jerry Duffey; Jerry Jones; Joe Wilbert III; John LeBlanc; John Logan; Josh Norton; Julie Caler; Keith Tinker; Kristen Green; Lauren Hovde; Lindsay Kramer; Matthew Hilgemeier; Matthew Robinson; Mitchell Carson; Molly Hitchcock; Paul Schoenfeld; Pete Garcia; Sean Dwyer; Steve Smith; Tony Michalsky; Wally Urrutia; Weldon Davis Date: 11/25/2008 4:24:25 PM Subject: Re: Calling for CO for 400 Harvey Mitchell Pkwy 400 No Sanitation issues. Rodney Harris Sanitation Foreman Public Works Tel(979)764-3698 Fax(979)764-3489 email: rharris@cstx.gov >>> Christina Court 11/25/2008 1:24 PM >>> Starvision bp#08-2875 Owner: Titan Valley Park Any issues, please contact the contractor CPFPCS Mgmt @ 713-355-4379. Christina Court CSR Planning & Development City Of College Station 979.764.3570 Christina Court CSR Planning & Development City Of College Station 979.764.3570 Benjamin McCarty - Re: Calling for CO for 400 Harvey Mitchell Pk wy 400 Page 1 From: Eaphrame Thomas To: Alan Gibbs; Benjamin McCarty; Brenda Godfrey; Brent Read; Bridgette George; Carol Cotter; Chris Haver; Christina Court; Cindy Dillard; Crissy Hartl; Donnie Willis; Doug Ervin; Eric Dotson; Eric Hurt; Erika Bridges; Gina Southerland; Israel Koite; James Boykin; Jason Schubert; Jennifer Prochazka; Jerry Duffey; Jerry Jones; Joe Wilbert III; John LeBlanc; John Logan; Josh Norton; Julie Caler; Keith Tinker; Kristen Green; Lauren Hovde; Lindsay Kramer; Matthew Hilgemeier; Matthew Robinson; Mitchell Carson; Molly Hitchcock; Paul Schoenfeld; Pete Garcia; Rodney Harris; Sean Dwyer; Steve Smith; Tony Michalsky; Wally Urrutia; Weldon Davis Date: 11 /26/2008 9:39:43 AM Subject: Re: Calling for CO for 400 Harvey Mitchell Pkwy 400 They are good for CO no issues. >>> Christina Court 11/25/2008 1:24 PM >>> Starvision bp#08-2875 Owner: Titan Valley Park Any issues, please contact the contractor CPFPCS Mgmt @ 713-355-4379. Christina Court CSR Planning & Development City Of College Station 979.764.3570 Christina Court CSR Planning & Development City Of College Station 979.764.3570 CC: Eaphrame Thomas Benjamin McCarty Re: Calling for CO for 400 Harvey Mitchell Pk wy 400 Page 1 } From: Paul Schoenfeld To: Alan Gibbs; Benjamin McCarty; Brenda Godfrey; Brent Read; Bridgette George; Carol Cotter; Chris Haver; Christina Court; Cindy Dillard; Crissy Hartl; Donnie Willis; Doug Ervin; Eaphrame Thomas; Eric Dotson; Eric Hurt;, Erika Bridges; Gina Southerland; Israel Koite; James Boykin; Jason Schubert; Jennifer Prochazka; Jerry Duffey; Jerry Jones; Joe Wilbert III; John LeBlanc; John Logan; Josh Norton; Julie Caler; Keith Tinker; Kristen Green; Lauren Hovde; Lindsay Kramer; Matthew Hilgemeier; Matthew Robinson; Mitchell Carson; Molly Hitchcock; Pete Garcia; Rodney Harris; Sean Dwyer; Steve Smith; Tony Michalsky; Wally Urrutia; Weldon Davis Date: 11/25/2008 1:16:33 PM Subject: Re: Calling for CO for 400 Harvey Mitchell Pkwy 400 OK on our side. Paul >>> Christina Court 11/25/2008 12:37 PM >>> Starvision Owner: Titan Valley Park Any issues, please contact the contractor CPFPCS Mgmt Christina Court CSR Planning & Development City Of College Station 979.764.3570 BUILDING POTENTIAL Austin McAllen Mexiro STARVISION College Station, Texas Project No. 7114.1 801 South Mopac Bldg. V, Suite 110 Austin, Texas 78746 Phono: 512 3281010 Fax: 512 328 3003 wwN.tagae.com ADDENDUM #1 February 14, 2008 Southcorp Realty Advisors, Inc. This Addendum forms part of the Contract Documents issued 02.11.08. The following changes, omissions, or alterations to the drawings shall be made. Receipt of this addendum shall be acknowledged by inserting its number and date of issue on the proposal. This Addendum is generally separated into sections for convenience; however, all contractors, subcontractors, material men and other parties shall be responsible for reading the entire addendum. The failure to list an item or items in all affected sections of this addendum does not relieve any party affected from performing as per instructions, providing that the information is set forth one time any place in this addendum. DRAWINGS: ITEM 1: Refer to Sheet G1.0 Cover Sheet: CHANGE paragraph 2 of Project Description, in Code Analysis to; `The existing building construction consists of reinforced concrete foundation supporting concrete tilt -wall panels and structural steel frame. Exterior walls are a combination of painted concrete, brick veneer and aluminum storefront. The roof is a metal roof over open pudin structure.", in lieu of, 'The existing building construction consists of reinforced concrete foundation supporting concrete tilt -wall panels and structural steel frame. Exterior walls area combination of painted concrete, brick veneer and aluminum storefront The roof is a metal roof over open pudin structure with minimum R19 insulation draped between purlins." ITEM 2: Sheet G1.0 Cover Sheet: UPDATE Index of Drawings for Plumbing, Mechanical & Electrical. ITEM 3: Refer to Sheet A1.1 Floor Plan: ADD to General Plan Notes; "3. Provide white vinyl faced R30 batt insulation at roof throughout tenant space." Attachments (8'/2 x 11): G1.0: Cover Sheet Dated02.14.08 A1.1: Floor Plan Dated 02.14.08 End of Addendum #1 STATE OF TEXAS: 1994 TEXAS ACCESSIBILITY STANDARDS (TAS) FEDERAL: 1992 AMERICANS WITH DISABILITIES ACT GUIDELINES (ADA) PROJECT DESCRIPTION: PROJECT WILL CONSIST OF A TENANT FINISH OUT IN A ONE-STORY INDUST BUILDING. BUILDING SQUARE FOOTAGE IS APPROX. 58,000 SF. T SPA IS MAT 18,028 SF T E EXISTING B DING CO RUC IST8 0 EINF GE CONCRETE FOUNDATION SUPPORTING CONCRETE TILT -WALL PANELS D STRUCTURAL STEEL FRAME. EXTERIOR WALLS ARE A COMBINATION OF PAINTED CONCRETE, BRICK VENEER AND ALUMINUM STOREFRONT. THE OOF IS A METAL .ROOF OVER OPEN PUR INS UCTURE. A INDEX OF DRAWINGS P1.1 PLUMBING LEGEND NOTES P1.2 PLUMBING SCHEDULES P2.1 PLUMBING DOMESTIC WATER P3.1 PLUMBING RISER DIAGRAM MECHANICAL MO.0 MECHANICAL GENERAL NOTES AND LEGENDS M1.1 MECHANICAL SCHEDULES M1.2 MECHANICAL SCHEDULES M2.1 MECHANICAL HVAC FLOOR PLAN M2.2 MECHANICAL HVAC ENLARGED PLAN M3.0 MECHANICAL DETAILS M4.0 MECHANICAL PIPING FLOOR PLAN ELECTRICAL EO.0 ELECTRICAL NOTES, SYMBOLS & ABBREVIATIONS ` E1.0 ELECTRICAL SCHEDULES:; - '; �•�-Y oCi E1.1 ELECTRICAL SCHEDULES & ONE -LINE E2.0 ELECTRICAL LIGHTING PLAN E3.0 ELECTRICAL POWER PLAN E3.1 ELECTRICAL HVAC PLAN E4.0 ELECTRICAL SPECIAL SYSTEMS Z 14-D°J i z ' r .� .�. .� '' '. P"='s 2 �.. n .� g.. tcgAL� STARVISION cova A°D�'1DSwu .; _i_s a. ii : + - a t. _ .s _ 901 South Mopoc Bldg. V. Suite 110 Austin, Texas 78746 TENANT FINISH OUT VALLEY PARK DATE 0214U8 PRO1ECf NO: 7f141 CIO COLLEGE STATION Phone: 512 328 1010 Fox: 512 328 3003 mm.l oe.cam 9 GENERAL PLAN NOTES 1. REFER TO SHEET A3.3 FOR DOOR AND WINDOW TYPES 2. REFER TO SHEET A3.3 FOR PARTITION TYPES. 3. PROVIDE WHITE VINYL FACED R30 BATT INSULATION AT OOF THROUGHOUT TENANT SPACE. A 2.14•ao tCgS. ! i 1. .. n..w °. a,'.: TENANT FINISH OUT DATE _-J a :_ .z.; 901 South c Btd V, Suite 110 Austin. Texas 78746 PARK 7TI408 PAOIECT NO:7714.1 All COLLEGE STATION Phone: 512 328 1010 Fox: 512 328 3003 www.tagoe.com . T 4t rI1A " COMcheck Software Version 3.5.2 Interior Lighting Compliance Certificate 20061ECC Report Date: 02/14/08 Data filename: 1:1Project120710l ACALClCOMcheck.cck Section 1: Project Information Project Type: Addition Project Title: Starvision Construction Site: Owner/Agent: Designer/Contractor. College Station, TX Buckley Parks Energy Engineering Associates 6615 Vaught Ranch Rd Suite #200 Austin, TX 78731 512-744A400 Section 2: General Information Building Use Description by. Activity Type Activity Tvuefs) Floor Area Manufacturing Facility 15000 Section 3: Requirements Checklist Interior Lighting: ❑ I. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 19500 18899 YES Controls, Switching, and Wiring: El 2. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously Illuminated. lighting In stairways or corridors that are elements of the means of egress. Ll 3. Master switch at entry to hotel/motel guest room. O 4. individual dwelling units separately metered_ ❑ 5. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions. Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or sleeping unit Areas that use less than 0.6 Watts/sq.ft El 6. Automatic lighting shutoff control In buildings larger than 5,000 sq.fL Exceptions: Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security. 7. Photoce[Vastronomical time switch on exterior lights. Exceptions. Project Title: Starvision Data filename: I:Wrojectl20710171CALCICOMcheck.cck Report date: 02/14/08 Page 1 of 9 Lighting intended for 24 hour use. 0 8. Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions. Bectronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement The proposed lighting design represented In this document Is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2006 IECC requirements In COMcheck Version 3.5.2 and to comply with the mandatory requirements in th Re uirements Checklist. ur_kl .,� A, ?rkJ - Elec. C. T � 210108 Name - Title Signature Date Project Title: Starvision Report date: 02/14/08 Data filename: I:1Project120710171CALC1COMcheck.cck Page 2 of 9 COMcheck Software Version 3.5.2 Interior Lighting Application Worksheet 2006 IECC Report Date: Data filename: I:1Projecl1207101nCALC1COMcheck.cck Section 1: Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B x C) Manufacturing Facility 15000 1.3 19500 Total Allowed Watts = 19500 Section 2: Proposed Lighting Power Calculation A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp I Ballast Lamps/ ff of Fixture (C X D) Fixture Fixtures Watt. yUfahuf4Cllif�n Ee9li '1.... :::" ... ,•.• :.. - .a.:...v n"•.. .. o: •.v:.. Linear Fluorescent 1: A. 2x4 Recessed Troffer / 48" T8 32W I Electronic 3 39 96L' 3744 Linear Fluorescent 2: B: 2x2 Recessed Troffer / 24" T8 17W / Electronic 3 13 93 1209 Linear Fluorescent 3: C: 2x4 Direct/indlrect / 48" T8 32W / Electronic 3 62 96 5952 Compact Fluorescent 1: D: 8" Open Recessed / Triple 4-pin 26W 1 Electronic 2 19 52 988 Linear Fluorescent 4: F. 2x4 Recessed Clean Rm 148" T8 32W / Electronic 3 14 95 1344 Linear Fluorescent 6: H: 1x4 Surface Mount / 48" T8 32W / Electronic 3 30 96 2880 Unear Fluorescent 7: J: 2x2 Direct/Indirect / 24" T8 17W / Electronic 3 10 51 510 Linear Fluorescent 8: K:17 / 48" T8 32W / Electronic 2 13 64 832 Linear Fluorescent 9: L:1x4 Teardrop 148" T8 32W / Electronic 1 45 32 1440 Total Proposed Watts = 18899 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Proposed Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 19500 Total Proposed Watts = 18899 . Project Compliance = 601 n .,•SOMME Project Title: Starvislon Report date: 02/14/08 Data filename: I:1Pmject120710171CALC1COMcheck.cck Page 3 of 9 J COMcheck Software Version 3.5.2 Mechanical Compliance Certificate 2006 IECC Report Date: 02/14/08 Data filename: I:IPmject120710171CALC1COMcheck cck Section 1: Project Information Project Type: Addition Project Title: Starvislon Construction Site: Owner/Agent Designer/Contractor. College Station, TX Buckley Parks Energy Engineering Associates 6615 Vaught Ranch Rd Suite #200 Austin, TX 78731 512-744-4400 Section 2: General Information Building Location (for weather data): College Station, Texas Climate Zone: 2a Heating Degree Days (base 65 degrees F): .1188 Cooling Degree Days (base 50 degrees F): 6851 Section 3: Mechanical Systems List u uantii System Type & Description 14 Heat Pump Splits, <54MBH: Heat Pump Splits, <54MBH 1 AH-18: Split System Heat Pump, Cooling Capacity >=54 - <65 kBtu/h, Air -Cooled Condenser I Single Zone 1 AH-8: Split System Heat Pump, Cooling Capacity >=65 - <90 kBtu/h, Air -Cooled Condenser / Single Zone 1 MAU-1: Healing: Duct Furnace, Electric I Cooling: Split System, Capacity >=240 - <760 kBtu/h, Air -Cooled Condenser / Single Zone 3 AH-6,12,13: Cooling: Split System, Capacity <54 kBtu/h, Air -Cooled Condenser / Single Zone 1 AH-14: Cooling: Split System, Capacity >=90 - <135 kBtu/h, Air -Cooled Condenser / Single Zone 2 UH-1, 2: Heating: Unit Heater, Electric 1 Process chiller (2 ton): Cooling: Water Chiller, Capacity <50 tons, Condenser Air -Cooled, Rotary Screw or Scroll Chiller 2 Storage Water Heater 1 & 2: Electric Storage Water Heater, Capacity: 30 gallons 2 Instantaneous Water Heater 1 & 2: Electric Instantaneous Water Heater, Capacity: 1 gallons Section 4: Requirements Checklist Requirements Specific To: Heat Pump Splits, <54MBH 0 1. Equipment minimum effldency: Heat Pump: 0.8 HSPF, 10.0 SEER ❑ 2. Heat pump thermostat required when supplemental electric resistance heat is installed Requirements Specific To: AH-18 : 1. Equipment minimum efficiency: Heat Pump: 6.8 HSPF, 10.0 SEER O 2. Heat pump thermostat required when supplemental electric resistance heat is installed Requirements Specific To: AH-8 : 1.; Equipment minimum efficiency: Heat Pump: 3.2 COP, 10.1 EER Project Title: Starvision Report date: 02/14/08 Data filename: I:1Project120710171CALC1COMcheck.cck Page 4 of 9 2. Heat pump thermostat required when supplemental electric resistance heat Is installed Requirements Specific To: MAU-1 : [I 1. Equipment minimum efficiency: Split System: 9.5 EER, 9.7 IPLV Requirements Speclfic.To: AH-6,12,13 : 1. Equipment minimum efficiency: Split System: 10.0 SEER Requirements Specific To: AH-14 : 1. Equipment minimum efficiency: Split System: 10.3 EER Requirements Specific To: UH-1, 2: None Requirements Specific To: Process chiller (2 ton) : 1. Equipment minimum efficiency: Chiller: COP >= 2.80, IPLV >= 2.80 Requirements Specific To: Storage Water Heater 1 & 2: 1. Hot water system sized per manufacturer's sizing guide 2. Electric Water Heater efficiency >= 0.89 EF, 211 SL, Btu/h (if > 12 kW) 3. First 8 ft of outlet piping Is insulated 4. Hot water storage temperature adjustable down to 120 degrees F or lower S. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To: Instantaneous Water Heater 1 & 2: O 1. Hot water system sized per manufacturer's sizing guide 2. Electric Water Heater efficiency >= 0.93 EF, 55 SL, Btu/h (if > 12 kW) D 3. First 8 ft of outlet piping Is Insulated Generic Requirements: Must be met by all systems to which the requirement is applicable: Cl 1. Load calculations per 2001 ASHRAE Fundamentals 0 2. Plant equipment and system capacity no greater than needed to meet loads - Exception: Standby equipment automatically off when primary system is operating - Exception: Multiple units controlled to sequence operation as a function of load 17 3. Minimum one temperature control device per system O 4. Minimum one humidity control device per installed humidification/dehumidification system I] 5. Thermostatic controls has 5 degrees F deadband - Exception: Thermostats requiring manual changeover between heating and cooling 6. Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool); 7-day clock, 2-hour occupant override, 10-hour backup - Exception: Continuously operating zones - Exception: 2 kW demand or less, submit calculations 7. Outside -air source for ventilation; system capable of reducing OSA to required minimum 0 8. R-5 supply and return air duct insulation In unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 Insulation between ducts and the building exterior when ducts are part of a building assembly - Exception: Ducts located within equipment - Exception: Ducts with Interior and exterior temperature difference not exceeding 15 degrees F. - Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2 Inches w.g. pressure classification 9. Mechanical fasteners and sealants used to connect ducts and air distribution equipment O 10.Ducts sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 181 B tapes and mastics El I l.Holwater pipe insulation: 1 In. for pipes <=1.5 In. and 2 In. for pipes >1.5 in. Chilled water/refrigerantibdne pipe insulation: 1 in. for pipes <=1.5 in. and 1.5 In. for pipes >1.5 In. Steam pipe insulation: 1.5 In. for pipes <=1.5 in. and 3 in. for pipes >1.5 in. Exception: Pip"mg within HVAC equipment Exception: Fluid temperatures between 55 and 105 degrees F Exception: Fluid not heated or cooled Exception: Runouts <4 ft in length 12.0peratlon and maintenance manual provided to building owner Project Title: Starvision Report date: 02/14/08 Data filename: I:1Projec1120710171CALC1COMcheck.cck Page 5 of 9 O 13.Balancing devices provided in accordance with IMC 603.15 (] 14.Piping, insulated to 1/2 In. if nominal diameter of pipe is <1.5 in.; Larger pipe insulated to 1 in. thickness O 15.1-avatory faucet outlet temperatures In public restrooms limited to 110 degrees F (43 degrees C) O 16. Chilled water distribution systems —300 kBlu/h must have one of the following: a) controls that reset supply water temperature by 25% of supply/return delta T b) mechanical or electrical adjustable -speed pump drive(s) c) two-way valves at all healing coils d) multiple -stage pumps e) other system controls that reduce pump slow by at least 50% based on load - calculations required ❑ 17.Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings - Exception: Gravity dampers acceptable in buildings <3 stories - Exception: Gravity dampers acceptable in systems with outside or exhaust air flow rates less than 300 cfm where dampers are Interlocked with fan 11 18.Stair and elevator shaft vents are equipped with motorized dampers Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2006 IECC requirements In COMcheck Version 3.5.2 and to comply with the mandatory requirements in the Requirements Checklist. ? - Title Signature Date Project Title: Starvision� � � Report date: 02114108 Data filename: 1:1Project12071017\CALC1COMcheck.cck Page 6 of 9 COMcheck Software Version 3.5.2 Mechanical Requirements Description 2006 IECC Report Date: Data filename: I:1Project120710171CALCICOMcheck.cck The following list provides more detailed descriptions of the requirements In Section 4 of the Mechanical Compliance Certificate. Requirements Specific To: Heat Pump Splits, <54MBH : 1. The specified heating and/or cooling equipment is covered by the ASHRAE 90.1 Code and must meet the following minimum efficiency: Heat Pump: 6.8 HSPF, 10.0 SEER 2. Heat pumps having supplementary electric resistance heat must have controls that, except during defrost, prevent supplementary heat operation when the heat pump can meet the heating load. Requirements Specific To: AH-18 : 1. The specified heating and/or cooling equipment is covered by the ASHRAE 90.1 Code and must meet the following minimum efficiency. Heat Pump: 6.8 HSPF, 10.0 SEER 2. Heat pumps having supplementary electric resistance heat must have controls that, except during defrost, prevent supplementary heat operation when the heat pump can meet the heating load. Requirements Specific To: AH-8 : 1. The specified heating and/or cooling equipment is covered by the ASHRAE 90.1 Code and must meet the following minimum efficiency: Heat Pump: 3.2 COP, 10.1 EER 2. Heat pumps having supplementary electric resistance heat must have controls that, except during defrost, prevent supplementary heat operation when the heat pump can meet the heating load. Requirements Specific To: MAU-1 : 1. The specified heating and/or cooling equipment is covered by ASHRAE 90.1 Code and must meet the following minimum efficiency. Split System: 9.5 EER, 9.7 IPLV Requirements Specific To: AH-6,12,13 : 1. The specified heating and/or cooling equipment is covered by ASHRAE 90.1 Code and must meet the following minimum efficiency: Split System: 10.0 SEER Requirements Specific To: AH-14 : 1. The specified heating andlor cooling equipment Is covered by ASHRAE 90.1 Code and must meet the following minimum efOclency. Split System: 10.3 EER Requirements Specific To: UH-1, 2: None Requirements Specific To: Process chiller (2 ton) : 1. The specified heating and/or cooling equipment Is covered by the ASHRAE 90.1 Code and must meet the following minimum effdency: Chiller. COP - 2.80. IPLV - 2.80 Requirements Specific To: Storage Water Heater 1 & 2: 1. Service water heating system design loads for the purpose of sizing systems and equipment must be determined in accordance with manufacturers' published sizing guidelines. 2. Service water heating equipment used solely for heating potable water, pool heaters, and hot water storage tanks must meet the following miniumum efficiency: Electric Water Heater efficiency - 0.89 EF. 211 SL, Btu/h (If > 12 kW) 3. Insulation must be provided for the first 8 ft of outlet piping for a constant temperature nonreclrculatfng storage system and for the Inlet pipe between the storage tank and a heat trap in a storage system. 4. Temperature controls must be provided that allow for storage temperature adjustment from 120 degrees F or lower to a maximum temperature compatible with the intended use except when the manufacturer's Installation Instructions specify a higher minimum Project Title: Starvision Report date: 02/14/08 Data filename: I:1Project120710171CALC1COMcheck.cck Page 7 of 9 thermostat setting to minimize condensation and resulting corrosion. Documentation of the installation instructions must be provided to be exempted from this requirement. Heat traps must be provided on Inlet and outlet vertical pipe risers serving storage water heaters and storage tanks not having Integral heat traps and serving a nonreclrculating system. Heat traps must be Installed as close as practical to the storage tank. Acceptable heat traps are either a) a device specifically designed for the purpose or b) an arrangement of tubing that forms a loop of 360 degrees F, or c) piping that from the point of connection to the water heater (inlet or outlet) Includes a length of piping directed downwards before connection to the vertical piping of the supply water or hot water distribution system Requirements Specific To: Instantaneous Water Heater 1 & 2: 1. Service water heating system design loads for the purpose of sizing systems and equipment must be determined in accordance with manufacturers' published sizing guidelines. 2. Service water heating equipment used solely for heating potable water, pool heaters, and hot water storage tanks must meet the following minlumum efficiency. Electric Water Heater efficiency — 0.93 EF, 55 SL, Btulh (if > 12 kW) 3. Insulation must be provided for the first 8 ft of outlet piping for a constant temperature nonrecirculating storage system and for the Inlet pipe between the storage tank and a heat trap In a storage system. Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Design heating and cooling loads for the building must be determined using procedures in the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment providing both heating and cooling must satisfy this provislon for one function with the capacity for the other function as small as possible, within available equipment options. - Exception: The equipment and/or system capacity maybe greater than calculated loads for standby purposes. Standby equipment must be automatically cqntrolled to be off when the primary equipment and/or system Is operating. - Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed If they are provided with controls to sequence operation of the units as the load increases or decreases. 3. Each healing or cooling system serving a single zone must have Its own temperature control device. 4. Each humidification system must have its own humidity control device. 5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degrees F deadband (a range of temperature where no heating or cooling is provided). - Exception: Deadband capability is not required If the thermostat does not have automatic changeover capability between heating and cooling. 6. The system or zone control must be a programmable thermostat or other automatic control meeting the following criteria:a) capable of setting back temperature to 55 degrees F during heating and setting up to 85 degrees F during ccoMgb) capable of automatically setting back or shutting down systems during unoccupied hours using 7 different day schedulesc) have an accessible 2-hour occupant overrided) have a battery back-up capable of maintaining programmed settings for at least 10 hours without power. Exception: A setback or shutoff control Is not required on thermostats that control systems serving areas that operate continuously. Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Btu/h) or less. 7. The system must supply outside ventilation air as required by Chapter 4 of the Intemational Mechanical Code. If the ventilation system Is designed to supply outdoor -air quantities exceeding minimum required levels, the system must be capable of reducing outdoor -air flow to the minimum required levels. B. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditioned air located In unconditioned spaces (spaces neither heated nor cooled) must be Insulated with a minimum of R-5. Unconditioned spaces Include attics, crawl spaces, unheated basements, and unheated garages.b) Supply and return air ducts and plenums must be insulated to a minimum of R-8 when located outside the building.c) When ducts are located within exterior components (e.g., floors or roofs), minimum R-8 insulation Is required only between the duct and the building exterior. - Exception: Duct Insulation is not required on ducts located within equipment. - Exception: Duct Insulation Is not required when the design temperature difference between the interior and exterior of the duct or plenum does not exceed 15 degrees F. - Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification. 9. Mechanical fasteners and seals, mastics, or gaskets must be used when connecting ducts to fans and other air distribution equipment, Including multiple -zone terminal units. 10. All Joints, longitudinal and transverse seams, and connections in ductwork must be securely sealed using weldments; mechanical fasteners with seals, gaskets, or mastics; mesh and mastic sealing systems; or tapes_ Tapes and mastics must be listed and labeled in accordance with UL 1 B1A and shall be marked '181A-P' for pressure sensitive tape;181A-M' for mastic or'l B1A-1-1 for heat -sensitive tape. Tapes and mastics used to seal flexible air ductsand flexible air connectors shall comply with UL 1818 and shall be marked '181B-FX for pressure -sensitive tape or'181B-M' for mastic. Unlisted duct tape Is not permitted as a sealant on any metal ducts. 11. All pipes serving space -conditioning systems must be Insulated as follows: Hot water piping for heating systems: 1 In. for pipes <=1 1/24n. nominal diameter 2 in. for pipes >1 1/2-in. nominal diameter. Chilled water, refrigerant, and brine piping systems: 1 in. insulation for pipes —1 1/2-in. nominal diameter 1 1/2 In. insulation for pipes >1 1/2-in. nominal diameter. Steam piping: 1 1/2 In. Insulation for pipes <=1 1/2-in. nominal diameter 3 in. insulation for pipes >1 1/2-in. nominal diameter. - Exception: Plpe Insulation is not required for factory -Installed piping within HVAC equipment. Project Title: Starvislon Report date: 02/14/08 Data filename: I:1Project120710171CALC1COMcheck cck Page 8 of 9 - Exception: Pipe insulation is not required for piping that conveys fluids having a design operating temperature range between 55 degrees F and 105 degrees F. - Exception: Pipe Insulation is not required for piping that conveys fluids that have not been heated or cooled through the use of fossil fuels or electric power. Exception: Pipe Insulation Is not required for runout piping not exceeding 4 ft In length and 1 in. in diameter between the control valve and HVAC coll. 12. Operation and maintenance documentation must be provided to the owner that includes at least the following Information:a) equipment capacity (Input and output) and required maintenance actionsb) equipment operation and maintenance manuaisc) HVAC system control maintenance and calibration Information, including wiring diagrams, schematics, and control sequence descriptions; desired or field -determined set points must be permanently recorded on control drawings, at control devices, or, for digital control systems, In programming commentsd) complete narrative of how each system is Intended to operate. 13. Each supply air outlet or diffuser and each zone terminal device (such as VAV or mixing box) must have Its own balancing device. Acceptable balancing devices Include adjustable dampers located within the ductwork, terminal devices, and supply air diffusers. 14. Service hot water piping, where required, must be Insulated to 1/2 In. If pipe less than 1.5 in. nominal diameter. Larger pipe must be insulated to 1 in.. Pipe Insulation will have a conductivity of less than 0.28 Btu.in/(h-ft2-degrees F). 15. Temperature controlling means must be provided to limit the maximum temperature of water delivered from lavatory faucets in public facility restrooms to 110 degrees F. 16. Chilled water space -cooling systems with a capacity exceeding 300 kBtu/h supplying chilled water for comfort conditioning systems must Include controls that automatically reset supply water temperatures by representative building loads (including return water temperature) or by outside air temperature. Exceptions: - Where the supply temperature reset controls cannot be Implemented without causing improper operation of heating, cooling, humldlflcation, or dehumidification systems. - Hydronic systems that use variable flow to reduce pumping energy. 17. Outdoor air supply and exhaust systems must have motorized dampers that automatically shut when the systems or spaces served are not in use. Dampers must be capable of automatically shutting off during preoccupancy building warm-up, cool -down, and setback, except when ventilation reduces energy costs (e.g., night purge) or when ventilation must be supplied to meet code requirements. Both outdoor air supply and exhaust air dampers must have a maximum leakage rate of 3 cfm/ft2 at 1.0 In w.g when tested in accordance with AMCA Standard 500. - Exception: Gravity (non -motorized) dampers are acceptable in buildings less than three stories in height. - Exception: Systems with a design outside air intake or exhaust capacity of 300 cfm (140 Us) or less that are equipped with motor operated dampers that open and close when the unit is energized and de -energized, respectively. 18. Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and exhaust hoods, vents, and ventilators must be equipped with motorized dampers that will automatically shut when the spaces served are not in use. Exceptions: - Gravity (non -motorized) dampers are acceptable in buildings less than three stories In height above grade. - Ventilation systems serving unconditioned spaces. Project Title: Starvision Report dale: 02/14/08 Data filename: 1:1ProjeclR2D710l7\CALCiCOMcheck.cck Page 9 of 9 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 110.1 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764-3496 FACSIMILE COVER SHEET Date: f c6 2c3o o # of pages including coveZ IfYou chid not r�ceive a complete fax please call our office iMmedisr: fely for s new transmittal TO: _ k4r, 4'r /lr.. a 8,. COMPANY: �4 COMPANY: v;) ev" 7--em 4 )1 eh , FAX: i / 3 — 3 5'5- — Lr 2 7 S- Me_ REMARKS: ❑ Urgent P' For your review ❑ Repl y ASAP ❑ FYI TRANSMISSION VERIFICATION REPORT DATE DIME FAX NO./NAME DURATION PAGE(S) RESULT MODE TIME 02/21/2008 12:55 NAME FAX TEL SER.# 000L5J596800 02/21 12:54 917133554275-40681# 00: 00: 37 02 OK STANDARD ECM CITY OP COLLEGE NATION DEVELOPMENT SERVICES 1101 Texas Avenue South, p0 Box 9980 College Station, Texas 7 784 Z Phone 979,764.3570 / Fax 979.764.3496 FRCS LE COVER SHEET Date: t-'e4r �_I i '2-�a CIS ## of pages including cover: Ifyou did notreoeive s aompl�etefaxl please call vur ati`%ae unmediafalyfar s new. &ansmitisl TO: "r. r 11 *"" w a FAX: '7 / S— 3 SS` — Y 2 7 5- COMPANY., TxOM: c C-a. el COMANX: City of College St-aiinn_ TRANSMISSION VERIFICATION REPORT DATE DIME FAX NO./NAME DURATION PAGE(S) RESULT MODE TIME 02/21/2008 12:51 NAME FAX TEL SER.# 000L5J596800 02/21 12:50 915123283003-40681# 00:00:26 02 OK STANDARD ECM CITY OF COLLEGE STATION DEMOPMENT SERVICES 1101 Texas Avenue South, PO Box 9980 College S`1at10n, Texas 7784Z Phone 979.764.3870 / Fax 979.764.3496 FACSMME COVER SBEffr Date: Fed. 2,00 g # of pages including cover: 2 Ifyou drd not receive a completse fax, our 042' le immefflawy fop a new arms TO; G rsw FAX: 5 (4 — -3 COMPANY: d► ::r�i 4es-vl of T t#r r., ri G COMPANY: City, of Coll ve SfiAfinn CITY OF COLLEGE STATION DEVELOPMENT SERVICES 110.1 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET Date: Fid - _Z1, ?moo 8 # of pages including cover: Z you did notrwerve a complete fax, please call our office unmediatelyfor anew transmittal, TO: L ism FAX. 5 ( � — 3 7o _ 3oc 3 COMPANY: RE: �rl►��iel.. We Mc COMPANY: City of Colles�e Station. Development Services REMARKS: ❑ Urgent IgPor your review ❑ Repl y ASAP ❑ FYI 64A .fId'14 1-1/0 .., it C`t a t., L-t 7A r CITY OF COLLEGE STATION February 21, 2008 Re: Starvision- 400 Harvey Mitchell Pkwy, Suite # 100 Application # 08-508 Dear Mr. Hillman & Ms. Lisa Fain, I have completed the plan review for the above referenced project and have the following comments. The plan review is based on the 2006 International Codes, the 2005 National Electrical Code, ANSI A117.1-2003 Accessibility Standards, and our local amendments. Where appropriate, I have included the applicable code sections. 1. Submit building envelope ComCheck 2006 IECC. 2. Change door #106A to swing towards front means -of -egress (direction of egress travel), two exit doors are required off corridor #106. 3. Provide an exit sign above Door #106A on the corridor #106 side to comply with section 1011 of the 2006 IBC. 4. Remove exit sign above Door #114A, because it is not an exit. A required exit path shall not pass through an intervening room which can be locked and obstruct egress (Project Room #4). Section 1014.2 of the 2006 IBC. 5. Provide an exit sign above Door #107A to comply with section 1011 of the 2006 IBC. 6. Provide demarcated, minimum 44" wide on floor of egress path/corridor adjacent to rear overhead loading/unloading door to maintain required egress width to exit door without obstruction. 7. Locate fire extinguishers. 8. Submit fire sprinkler and fire alarm plans to Fire Marshal Office, Eric Hurt, 979-764-3705 for approval prior to installation. P. The review does not include any civil or zoning issues or NRA requirements of the Unified Development Ordinance. Please respond to the plan review comments at your convenience. Three sets of plans addressing these issues will be required. Should you have any questions, contact me at 979-764-3754. Thank You, Ben McCarty Plan Examiner the heart of the Research Valley P.O. BOX 9960 1101 TEXAS AVENUE COLLEGE STATION • TEXAS • 77842 979.764.3510 www.cstx.gov eg� City of College Station Page of � Building Inspection Department PLANS EXAMINATION REPORT Address: Ko0 frvcy I`7►��( �%/G,,,.��0 Date: ig D g Project Name: Sint ✓ i S tov Drawing Number Code Ref. Number Questions or Comments 2 I ►•�; �0(�'r� F—iiveloofe Cows 611e&//- ?-v46 .t6G6 6 o k-.x. d s -�ropq -,4- Plea 4f - o �' - rest oroo rs �h G loll. I Pollo&-1111ee A04 4-:Ylli S1 k, AhoVc Poo►- 1 06 A ovr l'Gte Cor r ta(o r #' (O6 S�% . 1,-6C J DIN. 2 i5la t- ei►' r► Move peon /l N i� Sti4// 6e Ike w1 D V G al h e c fti4ot f G o' t; s r� G OI H e i,1<,<�' ! / /' f an i N�fr ►1 Yoean /a '4C, k y s/s 6 to l i 41ov►ale an t �'� s- vi i2bo ve Poo,, # 102 A ?/V V OV G We PnarC44* w► 1 r� i w, in...y C-( f (v o✓ o-F E r� �s12 -t G o rno(o a rca.r vvcr Lteao( 100-oe; u911010 i s/oor IV v►� a J v►�ya i.� r wr rc d �,.- r`d � '�'o ems` �- dm o � W- 6 B o � S T►'�^ `�i . Received by: Date: oc_ c Cl.(- p c4o-�-- Loo,,� I ��C000? / 10 0 -:-- I �- wo�� Ll� COMcheck Software Version 3.5.2 Envelope Compliance Certificate 2006 IECC Report Date: 02/20/08 Data filename: FA0717114 SlarAsion120—Schematic—Design17114.1 Comcheck--shell changedw.furring.stseam.cck Section 1: Project information Project Type: New Construction Project Tittle : Valley Park Construction Site: Owner/Agent: Designer/Contractor: 400 Harvey Mitchell Parkway David Hillman Michael Drewry College Station, TX 77845 Southcorp Realty Advisors, Inc. Drewry Martin, Inc. 3401 Allen Parkway 3707 N. St. Marys St. Suite 200 Suite 200 Houston, TX 77019 San Antonio, TX 78212 713-960-1680 210-738-3200 dhlllman®southcorprealty.com Section 2: General Information Building Location (for weather data): College Station, Texas Climate Zone: 2a Heating Degree Days (base 65 degrees F): 1788 Cooling Degree Days (base 50 degrees F): 6851 Vertical Glazing / Wall Area Pct.: 13% Activity Tvoeisl Floor Area Office 15025 Section 3: Requirements Checklist Climate -Specific Requirements: Component Name/Description Gross Area Cavity or Perimeter R-Value Cont. Proposed R-Value U-Factor Budget U-Factor Roof 1: Metal Building, Standing Seam 55027 30.0 0.0 0.051 0.065 Exterior West Wag: Solid Concrete:8" Thickness, Light Density, 5725 11.0 0.1 0.166 0.320 Furring: Metal Window 1: Metal Frame:Double Pane with Low-E, Clear, SHGC 180 — — 0.650 0.750 0.40, PF 0.64 Window 2: Metal Frame:Doubte Pane with Low-E, Clear, SHGC 138 — — 0.650 0.750 0.40, PF 0.64 Door 1: Glass, Entrance Door, SHGC 0.25, PF 0.64 42 -- — 0.350 1.100 Door 2: Uninsulated Double -Layer Metal, Swinging 42 -- — 1,200 0.700 Exterior East Wall: Solid Concrete:8" Thickness,Llght Density, 7920 11.0 0.6 0.162 0.320 Furring: Metal Window 3: Metal Frame:Double Pane with Low-E, Clear, SHGC 1080 — -- 0,650 0.750 0.40, PF 0.40 Window 4: Metal Frame:Double Pane with Low-E, Clear, SHGC 414 — — 0.650 0,750 0.40, PF 0.64 Door 3: Glass, Entrance Door, SHGC 0.25, PF 0.26 126 -- — 0.350 1.100 Door 4: Uninsulated Double.Layer Metal, Swinging 21 — --- 1.200 0.700 Exterior South Well: Solid Concrete: WThickness, Light Density, 7250 11.0 0.5 0.152 0.320 Furring: Metal Project Tiffs: Valley Park Report date: 02120108 Data filename: FAMA7114 StBrvisionl20—Schematic Design%7114.1 Comcheck_shell changedw.furring.stseam.ock Page 1 of 2 Door 5: Insulated Metal, Swinging 189 — — 0.600 0.700 Door 7: Insulated Metal, Non -Swinging 144 --- -- 0.125 1.450 Exterior North Wall: Solid Concrete:B" Thlckness,Light Density, 9466 11.0 0.6 0.152 0.320 Furring: Metal Window 5: Metal Frame:Double Pane with Low-E, Clear, SHGC 1260 — --- 0.650 0.750 0.40, PF 0.48 Window 6: Metal Frame:Double Pane with Low-E, Clear, SHGC 552 -- — 0.650 0.750 0.40, PF 0.36 Door 6: Glass, Entrance Door, SHGC 0.25, PF 0.36 168 -__ — 0.350 1.100 Floor 1: Slab-On-Grada:Unheated 1320 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: 0 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance with the manufacturer's Installation Instructions. 2. Windows, doors, and skylights certified as meeting leakage requirements. 0 3. Component R-values & U-factors labeled as certified. 0 4. Insulation Installed according to manufacturers instructions, In substantial contact with the surface being Insulated, and in a manner that achieves the rated R-value without compressing the Insulation. 0 5. No roof insulation Is installed on a suspended calling with removable ceiling panels. 6. Stair, elevator shaft vents, and other outdoor air Intake and exhaust openings in the building envelope are equipped with motorized dampers. 0 7. Cargo doors and loading dock doors are weather sealed. 8. Recessed lighting fixtures are: 0) Type IC rated and sealed or gasketed; or (it) installed inside an appropriate alr-tight assembly with a 0.5 Inch clearance from combustible materials and with 3 Inches clearance from Insulation material. Note: Vapor retarder not required in this location. Section 4: Compliance Statement Compliance Statement The proposed envelope design represented In this document Is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2006 IECC requirements in COMcheck Verslon 3.5.2 and to comply with the mandatory requirements in the Requirements Checklist Name - Title Signature Date Project Notes: Shell Building Architect Drewry Martin, Inc. Tenant Improvement, Suite 200 Architect: David Carson, TAG Intematlonal.901 S. Mopac,Bidg V, Suite 110 Austin, Texas 78746, 512-328-1010 Project Title: Valley Park Report date: 02/20/08 Data filename: F:10717114 Starvision120_Schematic_Designl7l l4.1 Comcheck_shell changedw.furring.stseam.cck Page 2 of 2 CITY OP COLLEGE S r'ATIQN February 21, 2008 Re: Starvilsion- 400 Harvey Mitchell Pkwy, Suite # 100 Application # 08-508 Dear Mr. Hillman & Ms. Lisa Fain, I have completed the plan review for the above referenced project and have the following comments. The plan review is based on the 2006 Wernational Codes, the 2005 National Electrical Code, ANSI A117.1-2003 Accessibility Standards, and our local amendments. Where appropriate, I have included the applicable code sections. 1. Submit building envelope ComCheck 2006 IECC. ✓2. Change door #106A to swing towards front means -of -egress (direction of egress travel), two exit doors are required off corridor #106. 3. Provide an exit sign above Door #106A on the corridor #106 side to comply with section 1011 of the 2006 IBC. 4. Remove exit sign above Door #114A, because it is not an exit. A required. exit path shall not pass through an intervening rooms which can be locked and obstruct egress (Project Room #4). Section 1014.2 of the 2006 IBC. 5. Provide an exit sign above Door #107A to comply with section 1011 of the 2006 IBC. vt. Provide demarcated, minimum 44" wide on Boor of egress patb/corridor adjacent to rear overhead loadinglunloading door to maintain required egress width to exit door without obstruction. 7. Locate fire extinguishers. 8. Submit fire sprinkler and fire alarm plans to Fire Marshal Office, Eric Hurt, 979-764-•3705 for approval prior to installation. 9. 71c review does not include any civil or zoning issues or NRA requirements of the Unwed ]Development Ordinance. Please respond to the plan review comments at your convenience. Tbree sets of plans addressing these issues will be required. Should you have any questions, contact me at 979-764-3754, Thank You, Ben McCarty Plan Examiner the heart of she Research V514 PO. BOX9960 1101 TEXAS AvENUE COLLEGE STATION - TEXAS, 77842 979.764.3510 WWW.c5tx.94v BUILDING POTENTIAL Austin McAllen Mexico 901 South Mopac Bldg. V, Suite 110 Austin, Texas 78746 Plione: 512 3281010 Fax: 512 328 3003 mvw.tagae.can February 22, 2008 College Station Development Services 1101 Texas Avenue South PO Box 9960 College Station, Texas 77842 Re: Response to Review Comments Starvision — 400 Harvey Mitchell Pkwy, Suite #100 College Station, TX TAG Project No. 7114.1 Application No. 08-508 Dear Mr. Ben McCarty, Please accept this letter and the attached revised drawings in response to the permit review comments received on 02.21.08. Below is the response to each comment: Building: Comment 1: Submit building envelope ComCheck 2006 IECC Response: The revised envelope compliance form is attached. Comment 2: Change Door #106A to swing towards front means -of -egress (direction of Now egress travel), two exit doors are required off corridor #106 1 Response: (See sheet A1.1 a, Revision 1, Dated: 02.22.08, attached) One of the double doors (Door #106A) will swing toward the front means of egress and one door will swing toward the back means -of -egress. // Comment 3: Provide an exit sign above Door #106A on the corridor #106 side to comply N� with Section 1011 of the 2006 IBC. Response: (See comment 2, response) Exit signs to be provided on both sides of Door #106A, per sheet E2.0, Dated: 2.22.08, attached. Comment 4: Remove exit sign above Door #114A, because it is not an exit. A required exit path shall not pass through an intervening room which can be locked and obstruct egress (Project Room #4) Section 1014.2 of the 2006 IBC. Response: Exit sign above Door #114A to be deleted, per sheet E2.0, Dated: 2.22.08, attached. Comment S: Provide an exit sign above Door #107A to comply with Section 1011 of the 2006 IBC. Response: An exit sign to be installed above Door #107A, per sheet E2.0, Dated: 2.22.08, attached. ,l City Review Comments TAG Project No. 6075.1 Page 2 of 2 X Comment 6: Provide demarcated, minimum 44" wide on floor of egress path/corridor adjacent to rear overhead loading/unloading door to maintain required egress width to exit door without obstruction. • Response: (See Sht. A1.1 b, Revision 1, Dated: 02.22.08, attached) A 44" wide path of egress shall be indicated by painted striping on the floor. Building Fire: UComment 7: Locate fire extinguishers. Response: See General Note #10, Sheet G1.0-Cover Sheet: Fire extinguishers shall be purchased and installed by the Contractor per local fire department and building code requirements. Comment 8: Submit fire sprinkler and fire alarm plans to Fire Marshal Office, Eric Hurt, 979- A/O 764-3705 for approval prior to installation. Response: Contractor to submit fire sprinkler and fire alarm shop drawings to Fire Marshall for review and comment prior to installation. Please call me if you have any questions or if you need additional information. Sincerely, TAG International, LLP David L. Carson, AIA, Partner Texas Registered Architect No. 17513 Cc: David Hillman, Southcorp Realty Advisors, Inc. Rod Tello, Sundance Construction Company Ron Pope, TAG International 11-17-'08 18:00 FROM-STARVISION 9794581481 T-077 P002/002 F-174 v Application to Stock/FixturelMove-in Prior to Issuance of a Certificate of Occupancy CM of CDUXGE STAMN Property Address: Company Name: Business Name: Property Owner or Manager Information: Name: U i ma vi --� Address: 6Lf City, State, Zip: �� I Phone: '� Mobile: 21 -7Z3 Sl1-i-� Construction Company Information: Name: Addres City, SI Phone: I am applying for permission to: Move furniture and/or equipment into the building >C Fixture and/or stock the building Conduct training for staff members only Other (Be Specific) .i mcf—I ea,r�l I hereby make application to the City of College Station to Perform the action(s) indicated above without the benefit of a Certificate of Occupancy. I certify that the above statements are true and correct. i understand that occupancy of a structure prior to obtaining a Certificate of Occupancy is a code violation and may result in the issuance of citatiou(s). I further understand that fines associated with citations range up to $2,000,00 per day. Applicant Signatur6aJ-'7-"S Printed N me• / t __1L,1,5 Date: 1'7 ,^ ���r♦����������������������1���11�11/1♦ ♦�����111���1��1�1�11�1111 Building Department Representative: - %9' Comments: Date: _ 1117' q / (9 11-17-'08 18:00 FROM-STARVISION 9794581481 T-077 PO01/OO2 F-174 TARVISI T E C H N t) L O 1700 Research Parkway Suite 170 College Station, TX 77845 Phone: 979 4584445 FAX: 979 4584481 www.starvisiontech.com To: City of College Station From: Gail Mills — 979-458-1445 x 32 TM F S Fax 979-764-3496 Pages: 2 (Including this page) Date: Nov 17, 2008 Re: Application for early move in Here is our completed application. Please let me know if you will need anything more in order to approve the application. Thank you for your help, G��S BUILDING PERMIT CITY OF COLLEGE STATION 101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . Application pin number Property Address . . . . . . Property ID: R #. Tenant nbr, name . . . . . . Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner TITAN VALLEY PARK, LTD PARTNERSHIP 6300 RIVERSIDE PLAZA LN NW ALBUQUERQUE NM 87120 08-00000508 Date 5/15/08 110916 400 HARVEY MITCHELL PKWY S 900 005001-1016-0000 R13556 STARVISION COMMERCIAL, OTHER J E SCOTT (ICL) GENERAL COMMERCIAL 630000 Contractor ------------------------ CPFPCS MGMT OUTSIDE CITY LIMITS-BL COLLEGE STATION TX 77840 --- Structure Information 000 000 OFFICE TENANT FINISHOUT Construction Type . . . . . NON-COMBUSTIBLE Occupancy Type . . . . . . BUSINESS Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB HEATED AREA 15000.00 INTERIOR WALL TYPE SHEETROCK SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 310.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 573279 Permit Fee . . . . 1920.00 Plan Check Fee .00 Issue Date . . . . 5/15/08 Valuation . . . . 630000 Expiration Date . . 11/11/08 Qty Unit Charge Per Extension BASE FEE 1660.00 130.00 2.0000 THOU BLDG, VAL 500001 & UP 260.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT: 5" ADDRESS NUMBERS, AND ON REAR DOOR(S): 2" HIGH ADDRESS NUMBERS AND NAME OF BUSINESS. FOR MULTI -FAMILY RESIDENTIAL PROVIDE UNIT NUMBER ON FRONT DOOR AND IDENTIFY EACH UNIT FROM A REAR FIRE ---------------------------------- ---------- _} ------------- ------ BUILDING DEPT REPRESEN`A�f E: �°� APPLICANT: [ 1/ BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00000508 Date 5/15/08 Application pin number . . . 110916 ---------------------------------------------------------------------------- Special Notes and Comments LANE. IDENTIFY MULTI -FAMILY BUILDINGS WITH 12" BUILDING NUMBERS, VISIBLE FROM ALL ADJACENT/NEARBY FIRE LANES. ALL NUMBERS AND LETTERS SHALL HAVE CONTRASTING BACKGROUNDS. Shall advertise only the name of, uses of, or goods or services available within the building, or tenant lease space, to which the banner is attached. Shall be mounted parallel to the face of the building. Shall not be cantilevered away from the structure. Shall not extend more than one foot from any exterior building face, mansard, awning, or canopy. Shall not obstruct any window, door, stairway, or other opening intended for ingress or for needed ventilation or light. Shall not be attached to any tree, fence, or public utility pole. NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY, WATER SUPPLY LINES SERVING THE THIRD FLOOR OR HIGHER, AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394 ELECTRICAL UTILITIES COMMENTS DEVELOPER INSTALLS CONDUIT PER CITY SPECS & DESIGN DEVELOPER PROVIDES TEMP BLANKET EASEMENT FOR CONSTRUCTION DEVELOPER POURS TRANSFORMER PAD PER CITY SPECS (IF NECESSARY) DEVELOPER PROVIDES 30' RIGID CONUDIT FOR RISER POLE (IF NECESSARY) DEVELOPER INSTALLS FIRST 10' OF CONDUIT ON RISER POLE. CITY INSTALLS REMAINING 201. DEVELOPER PROVIDES EASEMENTS FOR ELECTRIC INFRASTRUCTURE AS INSTALLED FOR ELECTRIC LINES. DEVELOPER PROVIDES DIGITAL SITE PLAN IN AUTOCADE 14 VERSION. EMAIL TO RBOLIN®CI.COLLEGE-STATION.TX.US DEVELOPER IS REPSONSIBLE FOR THE INSTALLATION OF SERVICE FROM TRANSFORMER TO BUILDING FOR QUESTIONS CONTACT RONNIE BOLIN AT 979-764-3614 *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -A- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BUILDING DEPT REPRESENT TI APPLICANT: rt BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00000508 Date 5/15/08 Application pin number . . . 110916 ---------------------------------------------------------------------------- Special Notes and Comments CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE PROVIDE COMBUSTION AIR: FOR GAS -FIRED APPLIANCES PER SECTION 304 OF THE 2006 INTERNATIONAL FUEL GAS CODE; FOR OTHER FUELS TO COMPLY WITH CHAPTER 7 OF THE 2006 IMC. Underground electrical conduit installation shall be installed per city specs and is the responsibility of the owner and/or contractor. Contact the electrical division at (979) 764-6314 for more information. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR REQUIRED EXIT DOOR(S) SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND RETURNED PROVIDE FIRE EXTINGUISHERS) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC) SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. *Assure Proper GFI Locations, Including One Within 25, Of Outside A/C Unit PROVIDE MINIMUM 42" CLEARANCE FROM CENTER LINE OF WATER CLOSET TO EDGE OF LAVATORY OR WALL TO COMPLY WITH ANSI 2003, ACCESSIBLE STANDARDS. PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. A KEY FOR EACH SHELL BUILDING AND/ OR TENANT DOOR IS REQUIRED. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT INTERIOR LIGHTING SHALL MEET THE CONTROLS AND WATTAGE REQUIREMENTS OF SECTION 505 OF THE 2006 INTERNATIONAL ENERGY CONSERVATION CODE. All roof and ground -mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from any public right-of-way or residential district within 150 ------------------------------------------------= -------------------------- BUILDING DEPT REPRESENTATI E: APPLICANT: ( I , �kl�- BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00000508 Date 5/15/08 Application pin number . . . 110916 ---------------------------------------------------------------------------- Special Notes and Comments feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screening rooftop equipment may include, but are not limited to encasement, parapet walls, or partition screens. CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) PROVIDE PANIC HARDWARE ON EXIT DOORS *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES AS PER THE ZONING ORDINANCE SECTION 12.3.L; ATTACHED SIGNS SHALL NOT EXTEND MORE THAN ONE FOOT AWAY FROM EXTERIOR BUILDING FACE Shall advertise only the name of, uses of, or goods or services available within the building or tenant lease space to which the sign is attached; Shall be parallel to the face of the building; Shall not be cantilevered away from the structure; Shall not extend more than one foot from any exterior building face, mansard, awning, or canopy; Shall not obstruct any window, door, stairway, or other opening intended for ingress or for needed ventilation or light; and Shall not be attached to any tree or public utility pole. CONSTRUCTION CONTRACTS OVER $50,000 REQUIRE SUBMISSION TO THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR (512) 463-3211 FOR MORE INFORMATION *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST - BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . 08-00000508 Date 5/15/08 Application pin number . . . 110916 ---------------------------------------------------------------------------- Special Notes and Comments BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK DOUBLE DOOR #106A WILL HAVE ONE DOOR SWING TOWARDS THE FRONT MEANS -OF -EGRESS AND THE OTHER DOOR WILL SWING TOWARDS THE BACK MEANS -OF -EGRESS, SEE 2ND SUBMITTAL REVISED PLANS ATTACHED TO APPROVED BUILDING PLANS. KEEP CONTRACTOR'S SET OF BUILDING PLANS ON JOB SITE EVERYDAY. PROVIDE ADDITIONAL EXIT SIGNS PER 2ND SUBMITTAL REVISED BUILDING PLANS, WHICH ARE ATTACHED TO APPROVED BUILDING PLANS, KEEP ON JOB SITE AT ALL TIMES. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 1920.00 1920.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 1920.00 1920.00 .00 .00 BUILDING DEPT REPRESENT APPLICANT: ------------ - ---------------------- FIVE : o APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY Of, Ccat.UGES7:a� IO'!� (979) 764-3570 (979) 764-3496 FAX Planning -Dewfopiuu.irmitit WWW CSTX.GOV ADDRESS/LOCATION: +00 Fpr ice DATE: ,JI rl APPLICATION # TEMP POLE # Toy K_A.7. NIR 00 LOT BLOCK SUBDIVISION SEC/PH BUSINESS/OWNER NAME: Spy'tC. �, ol.l., PHONE: rs I (on 00 O CONTRACTOR/HOMEOWNER: Suncln�ce� ��s ��c'�te-t PHONE: 1 -11- 000 CONTACT PERSON FOR REVIEW COMMENTS: a,J PHONE: (r;m) 3 2 -( OI O FAX: (�7I 2.) 32 -10 -3003 EMAI-: 4C;L%J - COYSaA 4!_­� �'rte..coon ELECTRICIAN: —f-6,A PLUMBER: HVAC: -}-tti d GOOD CENTS (Residential only): ACCESSORY/STORAGE ADDITION DEMOLITION (ASBESTOS SURVEY) DUPLEX (LANDSCAPE PLANS REQUIRED) LOCATION DESCRIPTION OF WORK: PROPOSED USE: MOVING NEW CONSTRUCTION PORTABLE STORAGE (RESIDENTIAL) PORTABLE STORAGE (NON-RESIDENTIAL) REMODEURENOVATION* 1 ht 11 CJk �✓► - � P tt iet o%t� ,-d C9' STRUCTURE USE: 4 1 v HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIG REVIEW COMMI EE APPROVAL: I d� TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ A 80091 S S VALUATION: $ 6130, 000 TOTAL AREA:-T / HEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: 0 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 0 ❑ SEWER TAP: ❑ WATER TAP: ❑ OTHER TAP: TEMP POLE GARAGE TYPE: SIZE SIZE SIZE SINGLE ] ATTAS KffD 77 i INTERIOR WALL TYPE: RE -ROOF SHELL ONLY SLAB ONLY SWIMMING POOL TENTS I e-11 EXTERIOR WALL TYPE: FOUNDATION TYPE: ; .0' ROOF TYPE: DOUBLE TRIPLE C=ft MM 9M F1 ER 4AC>W—E] CARPORT a SIGNATURE OF APPLICANT:� _- *If proposed work involves new commercia ons action or facade improvements/renovations to an existing commercial property, building elevations are required. ............................................................ Official Use Only Co ments: ES or NO Plans Examiner Zoning Official BUILDING POTENTIAL Austin McAllen Mexi(x) TRANSMITTAL Date: February 12, 2008 1 To: City of College Station 1101 Texas Avenue College Station, Texas 77840 Attn: Project No: 7114.1 Re: Starvision Valley Park 901 South Mopac Bldg. V, Suite 110 Austin, Texas 78746 Phone: 512 3281010 Fax: 512 328 3003 www.tagae.corn From: David L. Carson, AIA cc: David Hillman Copies Date Description 3 02.11.08 Permit Review Documents 1 Application for Building Permit ❑ For Approval ❑ For Your Use ❑ As Requested ❑ For Review and Comment Remarks: FedEx Ship Manager I Label 791498380742 Page 1 of 1 From: Origin ID: MMRA (512)328-1010 David Carson Fec[E& TAG International 901 South Mopac Building V, Suite Suite 110 Austin, TX 78746 CL3173]37RU20 SHIPTO: (979) 764-3570 BILL SENDER Ben McCarty City of College Station 1101 Texas Avenue College Station, TX 77840 Ship Date:12FEB08 ActWgt:1 LB System#: 3 838191 / I N ET8011 Account#: S Rf RRRf RRR Invoice # Dept # TRK# 7914 9838 0742 n�1 A9 CLLA Shipping Label: Your shipment is complete 1. Use the 'Print' feature from your browser to send this page to your laser or inkjet printer. WED -13FEB A4 PRIORITY OVERNIGHT 77840 TX -US IAH 2. Fold the printed page along the horizontal line. 3. Place label in shipping pouch and affix it to your shipment so that the barcode portion of the label can be read and scanned Warning: Use only the printed original label for shipping. Using a photocopy of this label for shipping purposes is fraudulent and could result in additional billing charges, along with the cancellation of your FedEx account number. Use of this system constitutes your agreement to the service conditions in the current FedEx Service Guide, available on fedex.com. FedEx will not be responsible for any claim in excess of $100 per package, whether the result of loss, damage, delay, non -delivery, misdelivery, or misinformation, unless you declare a higher value, pay an additional charge, document your actual loss and file a timely claim. Limitations found in the current FedEx Service Guide apply. Your right to recover from FedEx for any loss, including intrinsic value of the package, loss of sales, income interest, profit, attorney's fees, costs, and other forms of damage whether direct, incidental, consequential, or special is limited to the greater of $100 or the authorized declared value. Recovery cannot exceed actual documented loss. Maximum for items of extraordinary value is $500, e.g. jewelry, precious metals, negotiable instruments and other items listed in our Service Guide. Written claims must be filed within strict time limits, see current FedEx Service Guide. https://www.fedex.com/ship/domesticShipmentAction.do?method=doProcessShipment 2/12/2008