PREPARED 6/30/08, 7:55:32 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/30/08
------------------------------------------------------------------------------------------------
ADDRESS . : 4313 VELENCIA CT SUBDIV: CASTLEGATE SEC 8
TENANT, NBR: GATE CODE *8853
CONTRACTOR WESTERHEIM CUSTOM HOMES PHONE (979) 696-4163
OWNER GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL 184200-0801-0210
APPL NUMBER: 08-00000484 RESIDENTIAL, 1 UNIT DETACHED NEW
-------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 2/29/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00
2/29/08 AP February 29, 2008 9:36:17 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B115 02
4/07/08
BE
BLDG, FRAMING TIME: 17:00
4/07/08
AE
April 7, 2008 11:05:31 AM glsouth.
Tape seal all penetrations through tyvek.
B115 01
4/07/08
RH
BLDG, FRAMING TIME: 17:00
4/07/08
DP
April 7, 2008 11:29:25 AM kwolfe.
Tyvek is to cover walls completely to top plates.
Tape seal all windows, doors, and penetrtions through tyvek.
Tyvek missing.
Need nuts on all anchors and thighten completely.
Need joist hangers throughout.
Need draft stopping at chases and arches.
Need fireblocking at fireplace.
°
Need support for valleys.
Make sure to have 7 3/4" max at bottom step of stairs.
B130 01
4/08/08
BE
BLDG, INSULATION TIME: 17:00
4/08/08
AP
April 8, 2008 9:51:51 AM kwolfe.
B125 01
6/25/08
RH
BLDG, FINAL TIME: 17:00
6/25/08
DP
June 25, 2008 10:49:50 AM glsouth.
Nead-e. nsu a io .
t n
�.
B125 02 6/,0/08 111 BLDG, FINAL TIME: 17:00
June 27, 2008 2:50:35 PM ccourt.
-------------------------------------- COMMENTS AND NOTES -------------- ------ - JS----------
L.J
23,46
From:A-1 TERMITES To.6964164
Not: I's
A Termites
P.O. Box Mal, BrYar►, TX 77805-5481
979-589-1203 Ofe M-589-3655 Pax
A1Tsrmlt tcon0ne,net
Treatment Date: 2/28/2008
Treatment Titre: 10,30-12.00
Guarantee,.
2 Years
Renewal Date:
2/28/2008
Renewal Price;
$215.50
Property Names 6 Address
Property Owner
4313 Valencia
College Station, TX 77845
Invoice No.: 2008.2035
Payment Terms: tw Now
Tank Size: 525
Job/Project No:
EPA Reg. No: $1824-5
81111Name 4 Address
Wwerheirn Cwtom Homes
Fax: (979) 696.4164
DasortptIgn of Precvtw►n+ttian t rcatment
aaHons
Td*s
Chemical 8 PerceMage
Slab Ares
Amount Due
R"idesntial House Slab - Horizontal
341
0.65
AMaWhor SC 0 0.06%
3,411
477.54
foundation Partial Pretraatmont for
subt&Y,dM r► Termites
[TOW Due $477.54
tEacelpt of S,a %' " sisnctNP4 v
A-i Tsmites wants to thank you for your buxln=.
We now offer Bore -Cars Wood Pretreatments in plant of the foundatlon pretreatment. If you
would like more information planate Contact Our office at 9"-589-1208.
Please Pay From This INVOICE
(6/30/2008) Amber Carter- Re: Calling for C.O. @ 4313 Velencia Ct.J Pagel
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 6/30/2008 10:11 AM
Subject: Re: Calling for C.O. @ 4313 Velencia Ct.
Contacted Brandon Westerhiem at 575-8853
Terry Boriskie
City of College Station
Residential Plans Examiner
Ofc.979-764-3744 Fax 979-764-3496
>>> Paul Schoenfeld 6/30/2008 9:56 am >>>
NO for CO.
Sewer buried flagged.
PAUL
>>> Gina Southerland 6/30/2008 8:04 AM >>>
BP# 08-484
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.csbc.gov
WFl007489 / 001 City of College _S ation PAGE 1
REQ. DATE: 02/25/08 02/25/08 9:32:44
LOCATION: 4313 VELENCIA CT LOC ID: 196300
REQUESTOR: WESTERHEIM CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 02/25/08 SCHED COMPLETION: 02/25/08
********************************************************************************
JOB ORDER RESULT COMENTS
BUILDING PERMIT`
CITY OF GGLi-06E STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number .
. . . . 08-00000484
Date 2/25/08
Application pin number
. . . 954664
Property Address . .
. . . . 4313 VELENCIA CT
Property ID:
184200-0801-0210
R #:
R113907
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . CASTLEGATE SEC 8
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . PLANNED DEVL HOUSING
Application valuation
. . . . 198-198
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD WESTERHEIM CUSTOM
HOMES
4490 CASTLEGATE DR
3800 SH 6 S 108
COLLEGE STATION
TX 778453388 COLLEGE STATION
TX 77845
(979) 696-4163
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK/STONE
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
3.00
TYPE OF GARAGE (ATT/DET)
ATT/DET
HEATED AREA
3003.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.50
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
----------------------------------------------------------------------------
TRAFFIC IMPACT ANAL (TAZ)
441.00
Permit . . . . . .
BUILDING PERMIT
Additional desc . . AC
Permit pin number .
554394
Permit Fee . . . .
757.00 Plan Check Fee
.00
Issue Date . . . .
2/25/08 Valuation . .
. . 198198
Expiration Date . .
8/23/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
99.00 3.0000
----------------------------------------------------------------------------
THOU BLDG, VAL 100001-500000
297.00
Special Notes and Comments
-Make sure all Electrical and Smoke detectors are installed
per 2005 NEC.
--------
----------
C9-A1 ------------------
BUILDING DEPT REPRESENTATIVt: ---------
APPLICANT:
BUILDING PERMIT
CITY OF GOLLEVE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00000484 Date 2/25/08
Application pin number . . . 954664
----------------------------------------------------------------------------
Special Notes and Comments
-2nd Floor Windows are to be at least 24" AFF
-Narrow Wall Bracing To Be Fully Sheathed with placement of
4 Simpson Panels per plans.
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
---------------------- ----------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: e� wlok�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00000484 Date 2/25/08
Application pin number . . . 954664
----------------------------------------------------------------------------
Special Notes and Comments
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 1501 the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
-------------------------------- ---------------
BUILDING DEPT REPRESENTaTIV�:C-,qxlj
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00000484 Date 2/25/08
Application pin number . . . 954664
----------------------------------------------------------------------------
Special Notes and Comments
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
-------------------------------------------------�
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . . 08-00000484
Date
2/25/08
Application pin number . . . 954664
----------------------------------------------------------------------------
Special Notes and Comments
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF
DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL
SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER
HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN
36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED
(2003
IRC )
*U-Factor Ratings for Window % up to 15% is .65,
from 15%
to
20% is .55, from 20% to 25% is .54 and above 25%
is .46 or
lower.
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical)
WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT
BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
-----------------
Due
------------------------------
Permit Fee Total 757.00 757.00
----------
.00
.00
Plan Check Total .00 .00
.00
.00
Other Fee Total 750.00 750.00
.00
.00
Grand Total 1507.00 1507.00
.00
.00
-------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
08-00000485
Date 2/25/08
Application pin number . . .
055810
Property Address . . . . . .
4313 VELENCIA CT
Property ID:
184200-0801-0210
R #:
R113907
Application type description
TEMP POLE
Subdivision Name . . . . . .
CASTLEGATE SEC 8
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
PLANNED DEVL HOUSING
Application valuation . . . .
0
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS LTD
------------------------
WESTERHEIM CUSTOM
HOMES
4490 CASTLEGATE DR
3800 SH 6 S 108
COLLEGE STATION TX 778453388
COLLEGE STATION
TX 77845
(979) 696-4163
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . AC
Permit pin number . 554402
Permit Fee . . . . 20.00
Issue Date . . . . 2/25/08
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
----------------------------------------------------------------------------
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
---------------------------
Paid Credited
Due
Permit Fee Total 20.00
--------------------
20.00 .00
----------
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
__�_�a�
________________________________________________ .________________
BUILDING DEPT REPRESENTATIVE
APPLICANT:
CITY OF COLLEGE STATION
Planning d Dewlepnena Srrnua
ADDRESS/ LOCATION:
LOT 21 BLOCK 1
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
"I � 1r1 rw .. An
4 - I5"- °* � p�4
DATE: TRCC REG 6?
APPLICATION #
TEMP POLE # O
SUBDIVISION CASTLEGATE .ol� SEC/PH 8
I BUSINESS/OWNER NAME: WESTERHEIM CUSTOM HOMES PHONE:979-696-4163
I CONTRACTOR/HOMEOWNER: WESTERHEIM CUSTOM HOMES PHONE:979-696-4163
CONTRACTOR ADDRESS: 240 SOUTHWEST PKWY E COLLEGE STATION, TX 77840
ELECTRICIAN: HILCO PLUMBER: JB PLUMBING
HVAC: SEIGERT GOOD CENTS (Residential only): YES
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: NEW HOME
STRUCTURE USE: SINGLE FAMILY DWELLING
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (fA�WROJECT REGISTRATION# EABPRJ
VALUATION: $ l"l� I o ,/ TOTAL AREA:3411 HEATED AREA:3003
(Cost of Labor and Materials)
I PUBLIC SEWER
NUMBER OF BEDROOMS:
4
�X SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
3.5
SEWER TAP: 4"
INTERIOR WALL TYPE:
SHEETROCK
SIZE
WATER TAP: %11
EXTERIOR WALL TYPE:
BRICK/STONE
SIZE
I OTHER TAP:
FOUNDATION TYPE:
SLAB ON GRADE
SIZE
Ip� A TEMP POLE
ROOF TYPE:
COMP SHINGLES
•
V-�/ GARAGE TYPE: SINGLE DOUBLE
TRIPLE
X
ATTACHED XQ DETACHED �X CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade improvementstrenovations to an existing
commercial property, building elevations are required.
Official Use Only
m ents:
V E or NO
Plans Examiner Zoning Official
// -' Fotvyf
Z'� F'y S� w�
60i ' Gt%►�dvwx - 5/�� Im x &*04UO` Cam' ( `i.�
®� 1 J
-: .'a
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
InsulationR value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
r
Protection Against Subterranean Termites
Chemical Terrruticide Treatment (Soil Treatment)
10.8
13.0
30
0.31
6
14
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers ,
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
.w o
> PLAN REVIEW
(*f/ ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 0 �� y
DATE:
a-IS-vg
BUILDING ADDRESS:
4313 <,' c, C�
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size,
location indicated on plans
grade &
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
OK
IOK
PLAN REVIEW
(*f/'" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
NVqkj
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/
A. Hearth extensions
1. Fireplace o enin < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
TJ
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
1
CITY OF COLLEGE STATION
Planning d Development Servicei
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAtOg
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
A/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street pr6perty line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N K
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLAN EXAMINER
zg -va
ATE
68
2
• I
e• ovlx
I
T' I
e oerm
1.61 SO. FT0 I
I I
I
I I
I I
OOOOOOOOOO I
_oho
— V
I
0
I
0
I OQ
I
0�
U �
ao
m
�
`o
W
(/) -
ri
I
I
I
I
I
49.43'
I
I
WESTERHEIM CUSTOM HOMES
CASTLEGATE SECTION 8 LOT 21 BLOCK 1
4313 VELENCIA
SCALE = I° = 20'
O,
OD
5.71'
4V
REScheck Software Version 4.1.3
Compliance Certificate
Project Title: The Westerheim Residence
Report Date: 02/14/08
Data filename: C:\Users\Westerheim Custom Homes - Brandon\JOBS\544 - 2102 Joseph Creek\4313 velencia.rck
Energy Code: 2000 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 12%
Heating Degree Days: 1788
Construction Site: Owner/Agent: Designer/Contractor:
4313 Velencia Court Westerheim Custom Homes, Ltd
College Station, TX 77845 240 Southwest Parkway East
College Station, TX 77845
979-696-4163
brandon@westerheimcustomhomes.net
Compliance:
Compliance: 29.7% Better Than Code Maximum UA: 1124 Your UA: 790 Maximum SHGC: 0.40 Your SHGC: 0.34
Ceiling 1: Flat Ceiling or Scissor Truss 2607 30.0 0.0 91
Wall 1: Wood Frame, 16" o.c. 3467 13.0 0.0 248
Window 1: Wood Frame:Double Pane with Low-E 326 0.310 101
SHGC: 0.27
Window 2: Metal Frame:Single Pane 49 1.020 50
SHGC: 0.76
Door 1: Glass 42 0.310 13
SHGC: 0.38
Door 2: Solid 20 0.150 3
Floor 1: Slab-On-Grade:Unheated 273 0.0 284
Insulation depth: 0.0'
Furnace 1: Forced Hot Air78 AFUE
Air Conditioner 1: Electric Central Air14 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Version 4.1.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
/J/"4vN .1(. G✓E3my/wt.,% Z-/y-oCe
Name - Title Signature Date
Project Title: The Westerheim Residence Report date: 02/14/08
Data filename: C:\Users\Westerheim Custom Homes - Brandon\JOBS\544 - 2102 Joseph Creek\4313 velencia.rck Page 1 of 1