Loading...
HomeMy WebLinkAboutRES2008-00484, 08-485os-vr�f asr- ues ck� p) PREPARED 6/30/08, 7:55:32 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/30/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 4313 VELENCIA CT SUBDIV: CASTLEGATE SEC 8 TENANT, NBR: GATE CODE *8853 CONTRACTOR WESTERHEIM CUSTOM HOMES PHONE (979) 696-4163 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-0801-0210 APPL NUMBER: 08-00000484 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------- PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 2/29/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00 2/29/08 AP February 29, 2008 9:36:17 AM kwolfe. Strings On Setbacks O.K. Slab Ground Installed B115 02 4/07/08 BE BLDG, FRAMING TIME: 17:00 4/07/08 AE April 7, 2008 11:05:31 AM glsouth. Tape seal all penetrations through tyvek. B115 01 4/07/08 RH BLDG, FRAMING TIME: 17:00 4/07/08 DP April 7, 2008 11:29:25 AM kwolfe. Tyvek is to cover walls completely to top plates. Tape seal all windows, doors, and penetrtions through tyvek. Tyvek missing. Need nuts on all anchors and thighten completely. Need joist hangers throughout. Need draft stopping at chases and arches. Need fireblocking at fireplace. ° Need support for valleys. Make sure to have 7 3/4" max at bottom step of stairs. B130 01 4/08/08 BE BLDG, INSULATION TIME: 17:00 4/08/08 AP April 8, 2008 9:51:51 AM kwolfe. B125 01 6/25/08 RH BLDG, FINAL TIME: 17:00 6/25/08 DP June 25, 2008 10:49:50 AM glsouth. Nead-e. nsu a io . t n �. B125 02 6/,0/08 111 BLDG, FINAL TIME: 17:00 June 27, 2008 2:50:35 PM ccourt. -------------------------------------- COMMENTS AND NOTES -------------- ------ - JS---------- L.J 23,46 From:A-1 TERMITES To.6964164 Not: I's A Termites P.O. Box Mal, BrYar►, TX 77805-5481 979-589-1203 Ofe M-589-3655 Pax A1Tsrmlt tcon0ne,net Treatment Date: 2/28/2008 Treatment Titre: 10,30-12.00 Guarantee,. 2 Years Renewal Date: 2/28/2008 Renewal Price; $215.50 Property Names 6 Address Property Owner 4313 Valencia College Station, TX 77845 Invoice No.: 2008.2035 Payment Terms: tw Now Tank Size: 525 Job/Project No: EPA Reg. No: $1824-5 81111Name 4 Address Wwerheirn Cwtom Homes Fax: (979) 696.4164 DasortptIgn of Precvtw►n+ttian t rcatment aaHons Td*s Chemical 8 PerceMage Slab Ares Amount Due R"idesntial House Slab - Horizontal 341 0.65 AMaWhor SC 0 0.06% 3,411 477.54 foundation Partial Pretraatmont for subt&Y,dM r► Termites [TOW Due $477.54 tEacelpt of S,a %' " sisnctNP4 v A-i Tsmites wants to thank you for your buxln=. We now offer Bore -Cars Wood Pretreatments in plant of the foundatlon pretreatment. If you would like more information planate Contact Our office at 9"-589-1208. Please Pay From This INVOICE (6/30/2008) Amber Carter- Re: Calling for C.O. @ 4313 Velencia Ct.J Pagel From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 6/30/2008 10:11 AM Subject: Re: Calling for C.O. @ 4313 Velencia Ct. Contacted Brandon Westerhiem at 575-8853 Terry Boriskie City of College Station Residential Plans Examiner Ofc.979-764-3744 Fax 979-764-3496 >>> Paul Schoenfeld 6/30/2008 9:56 am >>> NO for CO. Sewer buried flagged. PAUL >>> Gina Southerland 6/30/2008 8:04 AM >>> BP# 08-484 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.gov WFl007489 / 001 City of College _S ation PAGE 1 REQ. DATE: 02/25/08 02/25/08 9:32:44 LOCATION: 4313 VELENCIA CT LOC ID: 196300 REQUESTOR: WESTERHEIM CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/25/08 SCHED COMPLETION: 02/25/08 ******************************************************************************** JOB ORDER RESULT COMENTS BUILDING PERMIT` CITY OF GGLi-06E STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00000484 Date 2/25/08 Application pin number . . . 954664 Property Address . . . . . . 4313 VELENCIA CT Property ID: 184200-0801-0210 R #: R113907 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 8 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 198-198 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS ------------------------ LTD WESTERHEIM CUSTOM HOMES 4490 CASTLEGATE DR 3800 SH 6 S 108 COLLEGE STATION TX 778453388 COLLEGE STATION TX 77845 (979) 696-4163 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK/STONE IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 3.00 TYPE OF GARAGE (ATT/DET) ATT/DET HEATED AREA 3003.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- TRAFFIC IMPACT ANAL (TAZ) 441.00 Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 554394 Permit Fee . . . . 757.00 Plan Check Fee .00 Issue Date . . . . 2/25/08 Valuation . . . . 198198 Expiration Date . . 8/23/08 Qty Unit Charge Per Extension BASE FEE 460.00 99.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG, VAL 100001-500000 297.00 Special Notes and Comments -Make sure all Electrical and Smoke detectors are installed per 2005 NEC. -------- ---------- C9-A1 ------------------ BUILDING DEPT REPRESENTATIVt: --------- APPLICANT: BUILDING PERMIT CITY OF GOLLEVE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00000484 Date 2/25/08 Application pin number . . . 954664 ---------------------------------------------------------------------------- Special Notes and Comments -2nd Floor Windows are to be at least 24" AFF -Narrow Wall Bracing To Be Fully Sheathed with placement of 4 Simpson Panels per plans. *Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. *ADD SMOKE DETECTOR(S) PER NOTES ON PLANS *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ---------------------- ---------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: e� wlok� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00000484 Date 2/25/08 Application pin number . . . 954664 ---------------------------------------------------------------------------- Special Notes and Comments *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 1501 the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC -------------------------------- --------------- BUILDING DEPT REPRESENTaTIV�:C-,qxlj APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00000484 Date 2/25/08 Application pin number . . . 954664 ---------------------------------------------------------------------------- Special Notes and Comments *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS -------------------------------------------------� BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00000484 Date 2/25/08 Application pin number . . . 954664 ---------------------------------------------------------------------------- Special Notes and Comments *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC ) *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ----------------- Due ------------------------------ Permit Fee Total 757.00 757.00 ---------- .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1507.00 1507.00 .00 .00 ------------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00000485 Date 2/25/08 Application pin number . . . 055810 Property Address . . . . . . 4313 VELENCIA CT Property ID: 184200-0801-0210 R #: R113907 Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE SEC 8 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ WESTERHEIM CUSTOM HOMES 4490 CASTLEGATE DR 3800 SH 6 S 108 COLLEGE STATION TX 778453388 COLLEGE STATION TX 77845 (979) 696-4163 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 554402 Permit Fee . . . . 20.00 Issue Date . . . . 2/25/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ---------------------------------------------------------------------------- TEMP ELECT POLE CONNECT 45.00 Fee summary Charged --------------------------- Paid Credited Due Permit Fee Total 20.00 -------------------- 20.00 .00 ---------- .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 __�_�a� ________________________________________________ .________________ BUILDING DEPT REPRESENTATIVE APPLICANT: CITY OF COLLEGE STATION Planning d Dewlepnena Srrnua ADDRESS/ LOCATION: LOT 21 BLOCK 1 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV "I � 1r1 rw .. An 4 - I5"- °* � p�4 DATE: TRCC REG 6? APPLICATION # TEMP POLE # O SUBDIVISION CASTLEGATE .ol� SEC/PH 8 I BUSINESS/OWNER NAME: WESTERHEIM CUSTOM HOMES PHONE:979-696-4163 I CONTRACTOR/HOMEOWNER: WESTERHEIM CUSTOM HOMES PHONE:979-696-4163 CONTRACTOR ADDRESS: 240 SOUTHWEST PKWY E COLLEGE STATION, TX 77840 ELECTRICIAN: HILCO PLUMBER: JB PLUMBING HVAC: SEIGERT GOOD CENTS (Residential only): YES CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION " SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: NEW HOME STRUCTURE USE: SINGLE FAMILY DWELLING HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (fA�WROJECT REGISTRATION# EABPRJ VALUATION: $ l"l� I o ,/ TOTAL AREA:3411 HEATED AREA:3003 (Cost of Labor and Materials) I PUBLIC SEWER NUMBER OF BEDROOMS: 4 �X SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 3.5 SEWER TAP: 4" INTERIOR WALL TYPE: SHEETROCK SIZE WATER TAP: %11 EXTERIOR WALL TYPE: BRICK/STONE SIZE I OTHER TAP: FOUNDATION TYPE: SLAB ON GRADE SIZE Ip� A TEMP POLE ROOF TYPE: COMP SHINGLES • V-�/ GARAGE TYPE: SINGLE DOUBLE TRIPLE X ATTACHED XQ DETACHED �X CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new commercial construction or facade improvementstrenovations to an existing commercial property, building elevations are required. Official Use Only m ents: V E or NO Plans Examiner Zoning Official // -' Fotvyf Z'� F'y S� w� 60i ' Gt%►�dvwx - 5/�� Im x &*04UO` Cam' ( `i.� ®� 1 J -: .'a Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls InsulationR value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating r Protection Against Subterranean Termites Chemical Terrruticide Treatment (Soil Treatment) 10.8 13.0 30 0.31 6 14 ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers , ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. .w o > PLAN REVIEW (*f/ ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 0 �� y DATE: a-IS-vg BUILDING ADDRESS: 4313 <,' c, C� I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, location indicated on plans grade & Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. OK IOK PLAN REVIEW (*f/'" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details NVqkj 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements NA/ A. Hearth extensions 1. Fireplace o enin < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/ TJ 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location 1 CITY OF COLLEGE STATION Planning d Development Servicei PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NA/ B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NAtOg A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements A/ A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street pr6perty line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N K Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." PLAN EXAMINER zg -va ATE 68 2 • I e• ovlx I T' I e oerm 1.61 SO. FT0 I I I I I I I I OOOOOOOOOO I _oho — V I 0 I 0 I OQ I 0� U � ao m � `o W (/) - ri I I I I I 49.43' I I WESTERHEIM CUSTOM HOMES CASTLEGATE SECTION 8 LOT 21 BLOCK 1 4313 VELENCIA SCALE = I° = 20' O, OD 5.71' 4V REScheck Software Version 4.1.3 Compliance Certificate Project Title: The Westerheim Residence Report Date: 02/14/08 Data filename: C:\Users\Westerheim Custom Homes - Brandon\JOBS\544 - 2102 Joseph Creek\4313 velencia.rck Energy Code: 2000 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: 4313 Velencia Court Westerheim Custom Homes, Ltd College Station, TX 77845 240 Southwest Parkway East College Station, TX 77845 979-696-4163 brandon@westerheimcustomhomes.net Compliance: Compliance: 29.7% Better Than Code Maximum UA: 1124 Your UA: 790 Maximum SHGC: 0.40 Your SHGC: 0.34 Ceiling 1: Flat Ceiling or Scissor Truss 2607 30.0 0.0 91 Wall 1: Wood Frame, 16" o.c. 3467 13.0 0.0 248 Window 1: Wood Frame:Double Pane with Low-E 326 0.310 101 SHGC: 0.27 Window 2: Metal Frame:Single Pane 49 1.020 50 SHGC: 0.76 Door 1: Glass 42 0.310 13 SHGC: 0.38 Door 2: Solid 20 0.150 3 Floor 1: Slab-On-Grade:Unheated 273 0.0 284 Insulation depth: 0.0' Furnace 1: Forced Hot Air78 AFUE Air Conditioner 1: Electric Central Air14 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 4.1.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. /J/"4vN .1(. G✓E3my/wt.,% Z-/y-oCe Name - Title Signature Date Project Title: The Westerheim Residence Report date: 02/14/08 Data filename: C:\Users\Westerheim Custom Homes - Brandon\JOBS\544 - 2102 Joseph Creek\4313 velencia.rck Page 1 of 1