HomeMy WebLinkAboutRES2008-00480, 08-48108- 4�I�Cfcn.p)
PREPARED 7/10/08, 8:20:10 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/10/09
------------------------------------------------------------------------------------------------
ADDRESS 2803 HORSEBACK DR SUBDIV: HORSE HAVEN PH 3
CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504
OWNER OAKWOOD CUSTOM HOMES GROUP LTD PHONE
PARCEL 336300-0304-0040
APPL NUMBER: 08-00000480 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 3/06/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00
3/07/08 AP March 6, 2008 11:01:21 AM glsouth.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 4/14/08 OC BLDG., FRAMING TIME: 17:00
4/14/08 AP April 14, 2008 9:16:32 AM bcaldwell.
B130 01 4/22/08 OC BLDG, INSULATION TIME: 17:00
4/22/08 AP April 21, 2008 4:44:37 PM acarter.
B125 01 7/08/08 DS BLDG, FINAL TIME: 17:00
7/09/08 DP July 8, 2008 12:51:20 PM ccourt.
needs energy information posted in electric panel
B125 02 7/10/09 BIBLDG, FINAL TIME: 17:00
AAlp 6z July 9, 2008 4:08:35 PM ccourt.
- ---------------- COMMENTS AND NOTES -------------------------------------- --------------f�- L2QLG�/�'f`LoAl
Date: 7/10/2008
Inspection Comments for Final-,
Permit Year: 8 permit Number: 48C
Address: 2803 HORSEBACK DR
Type
inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION-SL,
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION-SLi
IC
Slab Ground Installed
B125
BLDG, FINAL
IC
needs energy information posted in electric panel
E110
ELEC, ROUGH IN
IC
April 14, 2008 12:15:20 PM glsouth.
Ell
ELEC, ROUGH IN
IC
will need to install spark gaurd on vent hood outlet
E150
ELEC, FINAL
IC
July 8, 2008 12:55:30 PM ccourt.
E150
ELEC, FINAL
IC
see R.I. for exception notes.
P100
PLBG, ROUGH IN
IC
February 29, 2008 4:39:28 PM glsouth.
P105
PLBG, TOP OUT
IC
April 14, 2008 12:14:59 PM glsouth.
Page 1
-(7/10/2008) Amber Carter - Re: Calling for C.O. @ 2803 Horseback Dr Page 1 t
From: Mitchell Carson
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 7/9/2008 12:17 PM
Subject: Re: Calling for C.O. @ 2803 Horseback Dr
This one is ok..... Mitch
>>> Gina Southerland 07/09/08 8:18 AM >>>
BP# 08-480
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.csbc.aov
WFl006706 / 001 City of College Station
PAGE 1
REQ. DATE: 02/20/08 02/20/08 15:29:11
LOCATION: 2803 HORSEBACK DR LOC ID: 208700
REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 02/20/08 SCHED COMPLETION: 02/20/08
JOB ORDER RESULT CObBlENTS
1'1r1R-1J'CeJYJ0 cep: r=Lj r rOm: H-1 I.tKMI I t5 To:6902504
SUBTERRANEAN TERMITE PRECONSTRUCTION
DISCLOSURE FOR EACH ESTIMATE
Pa9e:2/6
For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of
treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember
that your architects or design engineers specifications must also be followed, unless they are in violation of the
law. Review the consumer information sheet for further information. If you have any questions, contact the pest
control company or the Texas Department of Agriculture, Structural Pest Control Service, P.O. Box 12847,
Austin, Texas 78711-2847. Phone: (512) 305-8250.
Contractor Name: Oakwood Custom Homes Location Name: Property Owner
Contractor Address: 4060 State Hwy 6 South 1oocation to Treat: 2803 Horseback Drive
College Station, TX 77845 College Station, +IIX 77845
Type of Treatment [ ] Full [X] Partial [ ] Wood [ ] Bait [ ] Conunercial [X] Single Family
A label of Maxxthor SC Termiticide(s) is enclosed.
The -percentage of the ternuticide(s) to be applied at this location is: 0.06%
Warranty Information provided must include the Complete Details of 'any Warranty provided
and the following: Thne Period of Warranty; Renewal Options and Cost, and Obligations of
the Contracting Parties.
If the warranty sloes not include the entire structure treated, the; areas included in the warranty are: (specify)
Total Square Feet to be Treated: 2001 Total Linear Feet to be Treated:
Approximate Meatiurcmcnts of the Structure(s) to be Treated:
r�ee!!�..Urslant(
Signature of Certified Applicator or
Technician Completing Estimate
A-1 Termites
Name of Pest Control Company
Russell C—Breland
Printed Name
03/05/2009
TPCL 11932
TPCL. No.
Date
Licensed and regulated under the Texas Structural Pest Control Act
Texas Dcpurtinent of Agriculture, Structural Pest Control Service, PO Box 12847, Auslirl, Texas 78711-2847, Phone: (512) 305-8250.
Pale 1 of 4
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
--------------------------------- ------------------------------------------
Application Number
. . . . . 08-00000480
Date 2/20/08
Application pin number . . . 768480
Property Address .
. . . . . 2803 HORSEBACK DR
Property ID:
336300-0304-0040
R #:
R305321
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name .
. . . . . HORSE HAVEN PH 3
Property Use . . .
. . . . . RESIDENTIAL
Property Zoning . .
. . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 96559
Owner
------------------------
Contractor
OAKWOOD CUSTOM HOMES
------------------------
GROUP LTD OAKWOOD CUSTOM HOMES
4060 SH 6 S
4060 SH 6 S
COLLEGE STATION
TX 77845 COLLEGE STATION
TX 77845
(979) 690-1504
--- Structure Information 000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1384.00
INTERIOR WALL TYPE
SHHETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
285.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit pin number .
553537
Permit Fee . . . .
448.00 Plan Check Fee
.00
Issue Date . . . .
2/20/08 Valuation . .
. . 96559
Expiration Date . .
8/18/08
Qty Unit Charge Per Extension
BASE FEE 260.00
47.00 4.0000 THOU BLDG, VAL 50001-100000 188.00
----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with Regular Garage
Framing with 24" Minimum OSB
--------------------------------------------- ----- ---- --'--------------
BUILDING DEPTT RREPRESENTATIVE
APPLICANT: Q.... `7_�,f',,,&
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00000480 Date 2/20/08
Application pin number . . . 768480
----------------------------------------------------------------------------
Special Notes and Comments
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
---------------------------------------------------- ----------------------
BUILDING DEPT REPRESENTATI E: •
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000480
Application pin number . . . 768480
Page 3
Date 2/20/08
Special Notes and Comments
If Wall to Window Ratio is up to 15% the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING S5TBACKS AND
----------------------- - - - - -✓ ----- -- ------ - - - - - -
BUILDING DEPT REPRESENTATIVE:
APPLICANT: //_ i, v
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00000480 Date 2/20/08
Application pin number . . . 768480
----------------------------------------------------------------------------
Special Notes and Comments
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
*GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
S-------------------------------- ------ -------=----------
BUILDING DEPT REPRESENTATIVE -
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
----------------- ----------
Permit Fee Total 448.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1198.00
Page
5
08-00000480
Date
2/20/08
768480
--------------------
448.00
----------
.00
.00
.00
.00
.00
750.00
.00
.00
1198.00
.00
.00
------------------------------------- --.- --'----------
BUILDING DEPT�REPRES�ENTTTATIVE:
A P P L I CANT :
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00000481 Date
863831
2803 HORSEBACK DR
336300-0304-0040
R305321
TEMP POLE
HORSE HAVEN PH 3
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
2/20/08
Owner
Contractor
------------------------
OAKWOOD CUSTOM HOMES
GROUP LTD
------------------------
OAKWOOD CUSTOM HOMES
4060 SH 6 S
4060 SH 6 S
COLLEGE STATION
TX 77845
COLLEGE STATION TX 77845
(979) 690-1504
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit pin number
. 553545
Permit Fee . . .
. 20.00
Issue Date . . .
----------------------------------------------------------------------------
. 2/20/08
Valuation . . . . 0
Fee summary
-----------------
Charged
Paid Credited Due
Permit Fee Total
----------
20.00
------------------------------
20.00 .00 .00
Grand Total
20.00
20.00 .00 .00
--------------------------------------------- ----
PT-- --- -------------
BUILDING DEPTREPRESENTATIVE:
APPLICANT: /T%i � /�
aU�
(*t1""
CITY OF COLLEGE STANONI
planning C? nrur1op'nrnt sr.mirct
ADDRESS/LOCATION:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
V//
zsEFYUc .
F r rr Uso oMy
DATE: � RCC REG 1091
APPLICATION #
TEMP POLE #
LOT 4 BLOCK `i / SUBDIVISION
111— ✓
� Mge s�V Iv IGT/SEC/PHAn
^
BUSINESS/OWNER NAME: ALTON l l�
7A7 �J [�
GLL PHONE: '7rJ L_
CONTRACTOR/HOMEOWNER: ONANODO
/n���
l� 9DM NO ES PHONE: UV� O —tSC -
CONTACT PERSON FOR REVIEW COMMENTS:
h 1` V T�LUN DELI— PHONE: �-W —0 113
FAX: (oq D - / 504V
EMAIL: .Imy)i�a U9 lr lb Coro
ELECTRICIAN: oIJ�LYYI DI /
.
PLUMBER: I `i/Yl/lI�/1a and
HVAC: �1�PX"1
GOOD CENTS (Residential only): it 7
ACCESSORY/STORAGE
MOVING
RE -ROOF
ADDITION
DEMOLITION (ASBESTOS SURVEY)
NEW CONSTRUCTION"
PORTABLE STORAGE (RESIDENTIAL)
SHELL ONLY
SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED)
PORTABLE STORAGE (NON-RESIDENTIAL)
SWIMMING POOL
LOCATION
REMODEL/RENOVATION"
TENTS
DESCRIPTION OF WORK:
PROPOSED USE:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY /STANDARD
�(TAS)y'ROJECT REGISTRATION# EABPRJ rp
VALUATION: $ 1 l0 1 5S / TOTAL AREA: XO j HEATED AREA: �J
(Cost of Labor and Materials)
0 PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP: 4
WATER TAP: 3 y
SIZE
OTHER TAP:
TEMP POLE
GARAGE TYPE
SIZE
SINGLE
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
5
1z
SIGNATURE OF APPLICANT: V Ulm vr' `l!5
If proposed work involves new comm r ial constructio r facade improvements/renovations to an existing
commercial property, building elevatio are required.
_ Official Use Only
Co ments:
r NO
G" WI A Plans Examiner Zoning Official
Fo `\„ S,
f t
En4r4y,.Lode Compliance Information
t
% Glazing of exterior walls '
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
toiC
30
c4
Protection Against Subterranean Termites
Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning &DevelapmentServica COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
DATE:
BUILDING ADDRESS:
03 b�Ck ,
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
WOK
Il. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
O
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
/OK
IOK
MAI
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning dDevelopment Semicef COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
_
IV. Fireplace Requirements
)
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
Nl�p
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d Development Srrnrca
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N O
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N
O
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NAVOKI
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
JK
Does not block an water course or divert an flow
Elevation certificate needed
"APPROVED PLANS PER IRC SECTION R106.3.1."
jX � "__ 0� `l�_-o15
PLANS EXAMINER DATE
)1"REScheck Softwa.rn- Version 4.1.1
Compliance Certificate
Project Title: The Wagonwheel
Report Date: 02/07/08
Data filename: C:\Program Files.\ART Inc\Chief Architect 10.0 Full Version\Project file\oakchb\wagonwheehwagonwheel.rck
Pnergy Code:
2003 IECC
e
Location:
College Station,
Texas
Construction Type:
Single Family
Glazing Area Percentage:
13%
Heating Degree Days:
1788
Construction Site:
Owner/Agent:
Designer/Contractor:
Horseback Drive
Alton Ofczarzak
Alton Ofczarzak
College Station, TX 77845
Oakwood Custom Homebuilders, LLC
Oakwood Custom Homebuilders, LLC
4060 State Highway 6 South
4060 State Highway 6 South
College Station, TX 77845
College Station, TX 77845
979-690-1504
979-690-1504
seig @oakchb.com
janalane@suddenlink.net
Compliance: 20.7% Better Than Code
Maximum UA: 555 Your UA: 440
Maximum SHGC: 0.40 Your SHGC: 0.30
Ceiling 1: Flat Ceiling or Scissor Truss
1384
0.0
30.0
43
Wall 1: Wood Frame, 16" o.c.
98
13.0
0.0
6
Window 1: Metal Frame:Double Pane with Low-E
15
0.540
8
SHGC: 0.30
Window 1 copy 1: Metal Frame:Double Pane with Low-E
15
0.540
8
SHGC: 0.30
Wall 2: Wood Frame, 16" o.c.
32
13.0
0.0
3
Wall 3: Wood Frame, 16" o.c.
55
13.0
0.0
5
Wall 4: Wood Frame, 16" o.c.
100
13.0
0.0
8
Wall 5: Wood Frame, 16" o.c.
166
13.0
0.0
12
Door 1: Solid
20
0.140
3
Wall 6: Wood Frame, 16" o.c.
202
13.0
0.0
16
Window 3: Metal Frame: Double Pane with Low-E
4
0_540
2
SHGC: 0.30
Wall 7: Wood Frame, 16" o.c.
164
13.0
0.0
8
Window 4: Metal Frame:Double Pane with Low-E
15
0.540
8
SHGC: 0.30
Window 4 copy 1: Metal Frame:Double Pane with Low-E
15
0.540
8
SHGC: 0.30
Window 6: Metal Frame: Double Pane with Low-E
17
0.540
9
SHGC: 0.30
Window 6 copy 1: Metal Frame:Double Pane with Low-E
17
0.540
9
SHGC: 0.30
Wall 8: Wood Frame, 16" o.c.
56
13.0
0.0
3
Door 2: Glass
18
0.540
10
SHGC: 0.30
Wall 9: Wood Frame, 16" o.c.
70
13.0
0.0
3
Window 8: Metal Frame:Double Pane with Low-E
18
0.540
10
SHGC: 0.30
Window 8 copy 1: Metal Frame:Double Pane with Low-E
18
0.540
10
SHGC: 0.30
Wall 10: Wood Frame, 16" o.c.
22
13.0
0.0
2
Project Title: The Wagonwheel
Page 1 of 2
Data filename: C:\Program Files\ART Inc\Chief Architect 10.0 Full Version\Project file\oakchb\wagonwheel\wagonwheel.rck
Report
date:
Wall 11: Wood Frame, 16" o.c. 76 13.0 0.0 5
ti Window 10: Metal fr'ame:Double Pane with Low-E 10 ` 0.540 5
SHGC: 0.30
Wall 12: Wood Frame, 16" o.c. 392 13.0 0.0 31
Window 11: Metal Frame:Double Pane with Low-E 15 0.540 8
SHGC: 0.30
Window 12: Metal Frame:Double Pane with Low-E 4 0.540 2
SHGC: 0.30
Floor 1: Slab-On-Grade:Unheated 187 0.0 195
Insulation depth: 0.0'
Furnace 1: Forced Hot Air78 AFUE
Air Condilpner 1: Electric Central Air14 SEER
Compliance Statement The proposed building design described hcrc is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 4.1.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
Project Notes:
lot 4, blk 4, phase 111, Horse Haven
Project Title: The Wagonwheel Page 2 of 2
Data filename: C:\Program Files\ART Inc\Chief Architect 10.0 Full Version\Project file\oakchb\wagonwheel\wagonwheel.rck Report
date: