HomeMy WebLinkAboutRES2008-00476, 08-477�i r ol�� b --, \ \ PREPARED 8/08/08, 12:10:02 INSPECTION TICKET PAGE 4 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/08/08 ------------------------------------------------------------------------------------------------ ADDRESS 2823 HORSEBACK DR SUBDIV: HORSE HAVEN PH 3 CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504 OWNER OAKWOOD CUSTOM HOMES GROUP LTD PHONE PARCEL 336300-0304-0110 APPL NUMBER: 08-00000476 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 3/14/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00 3/14/08 AP March 14, 2008 9:58:37 AM acarter. Strings On Setbacks O.K. Slab Ground Installed B115 01 4/14/08 OC BLDG, FRAMING TIME: 17:00 4/14/08 AP April 14, 2008 9:16:58 AM bcaldwell. B130 01 4/21/08 BB BLDG, INSULATION TIME: 17:00 4 8 AP April 21, 2008 12:06:13 PM glsouth. B1r25 01 �1171. BI BLDG, FINAL TIME: 17:00 August 8, 2008 10:42:36 AM bboerboom. -------------------------------------- COMMENTS AND NOTES------------------------- MAR-14-2008 09:35 From:A-1 TERMITES Top6902504 SUBTERRANEAN TERMITE PRECONSTRUCTION DISCLOSURE FOR EACH ESTIMATE Page:2,'B bS 4-1� For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minilmum treatment standards. Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer infornation sheet for further information, if you have any questions, contact the pest control company or the Texas Department of Agriculture, Structural. Pest Control Service, P.O. Box 12847, Austin, Texas 7871 l -2847. Phone: (512) 305-8250. Contractor Nance: Oakwood Custom Homes Location Name: Property Owner Contractor Address. 4060 State Hwy 6 South I .ocation to Treat: 2823 Horseback Drive College Station, TX 77845 College Station, TX 77845 Type of Treatment [ ] Full [XJ Partial [ ] Wood [ ] Bait [ ] Conuncrcial [X] Single Family A label of Maxxthor SC Termiticide(s) is enclosed. The percentage of the termiticide(s) to be applied at this location is: 0.06% Warranty Information provided must include the Complete Details of any Warranty provided and the fallowing: Time Period of Warranty; Renewal. Options and Cost; and Obligations' cf the Contracting Parties. Tithe warranty does not include the entire structure treated, the areas included in the warranty are: (specify) Total Square Feet to be Treated: 201.1. Total Linear Feet to be Treated: Approximate Measurements of the Structure(s) to be Treated: W"If G. Z...f d Russell C. Breland 03/08/2008 Signature of Certified Applicator or Printed Name Date Technician Completing L:stimate A-1 Termites TPC1_, 11932 Name of Pest Control Company TPCL. No. Licensed and regulated under the Texas Structural Pest Control Act 1'exas Department of Agriculture, Structural Pest Control Service, PO Box 12847, Austin, 'texas 7871 l-2847, Phone: (512) 305-8250. Page 1 of 4 From: Terry Boriskie To: Alan Gibbs Date: 6/24/2008 9:20 AM Subject: Re: Fwd: Horse Haven Phi Bk4 Lts1O, 11, and 12 They are actually. Lots 10, it and 17 and the only one permitted at this time is Lot 17. I believe since Oakwood owns the subdivision that they are still in their name, but could be sold. Terry Boriskie City of College Station Residential Plans Examiner Ofc. 979-764-3744 Fax 979-764-3496 >>> Alan Gibbs 6/24/2008 9:18 am >>> Are each of these lots Oakwood? Alan Gibbs, P.E. City Engineer City of College Station, Public Works >>> Alan Gibbs 6/24/2008 8:34 AM >>> Can you put this on all the noted lots: "Existing Drainage must be allowed to continue to conveyed across this lot. Raised slabs are appropriate, but lot lines must remain 'low' and ensure drainage is not blocked." Alan Gibbs, P.E. City Engineer City of College Station, Public Works >>> Alan Gibbs 4/10/2008 3:31 PM >>> fyi Alan Gibbs, P.E. City Engineer City of College Station, Public Works >>> Alan Gibbs 4/10/2008 3:25 PM >>> Alton, The Herman's have made us aware that there is a drainage swale that will be altered with the development of these lots which has the potential to block drainage flows if not properly addressed. You are likely aware of the existing concrete flume discharging from the Herman property into the middle of Lot 17. This specific drainage as well the general drainage must be accommodated by keeping the downstream lot lines low to enable the drainage to discharge to Horseback Drive. The raised slabs are appropriate, but again the lot lines must remain "low" and ensure drainage is not blocked. We'll check this ultimately at the issuance of COs. This notice is an effort to inform you sooner rather than later so this can be best addressed. Alan Gibbs, P.E. City Engineer City of College Station, Public Works i I: t L - - IV k 13- v lz� 12 c N1 pp 1 ' OAKWOOD CUSTOM HOM' OUP L 1 HERMANN, BURT & VIRGINIA -- e co OAKWOOD C - STOM HOMES GRO QHERMANN, BU T & VIRGINIA 9 C"*/ .. ERMANN BURT & VIRGINIA OAKWOOD CUSTOM HOMES GROUP LTD € OTT, DIANA8 � r � �'1r1 30A.. OOD CUSTOM HOMMGROUP LTD 1 0 50 100 200 300 08/12/2008 09:20 FAX 9796902504 CERTIFIED COPY R 003 MAR-14-2008 09:35 From:A-1 TERMITES To':6902504 Pi�,e:2/8 SUBTERRANEAN TERMITE PRECONSTRUC.TION DISCLOSURE FOR EACH ESTIMATE For all treatments there will be a diagram showing exactly what will be treated prior to the be; inning of treatment. Review the pesticide label provided to you at this time for minimum treatment stall lards. Remember that your architects or design engineers specifications must also be followed, unless they are it violation of the law. Review the consumer information sheet for further information. If you have any question . contact the pest control company or the Texas Department of Agriculture, Structural Pest Control Service, N Box 12847, Austin, Texas 78711-2847. Phone: (512) 305-8250. Contractor Name: Oakwood Custom Homes Location Name: property Owil :r Contractor Address: 4060 State Hwy 6 South location to Treat: 2823 Horsebal k Drive College Station, TX 77845 College Statiol,., TX 77845 Type of Treatment [ ] Full [X) Partial [ ] Wood [ ] Bait [ ] Commercial [X] Sing):: Family A label of Maxxthor SC Termiticide(s) is enclosed. The percentage of the termiticide(s) to be applied at this location is: 0.06% Warrantp Information provided must urclude the Complete Details of any war runty provided and the following. Time Period of Warranty; Renewal Options and Cost; and � )bligationc of the Contracting Parties. If the warranty does not include the entire structure treated, the areas included in the warranty ire: (specify) Total Square Feet to be Treated: 2011 Total Linear Feet to be Treater: Approximate Measurements of [lie Structure(s) to be Treated: Z,.,el d Russell C. Breland 03/8/2008 Signature of Certified Applicator or Printed Name Date Technician Completing hstimate A-1 Termites TPCL 11932 Name of Pest Control Company TPCL. No. Licensed and regulated under the Texas Structural Pest Control Act Texas Department of Agriculture, structural Pest Control service, Po Box 12847, Austin, Texas 78711-2847, Phi ,te: (512) 305-8250. Page 1 of 4 (8/12/2008) Bethany Boerboom - Re Calling for CO'for 2823 Horseback,Dr Page From: Mitchell Carson To: Amber Carter; Benjamin McCarty; Bethany Boerboom; Chris Haver; Gina ... Date: 8/11/2008 4:19 PM Subject: Re: Calling for CO for 2823 Horseback Dr NO to CO Sewer box it broken on clean out needs to be replaced ....... Mitch >>> Bethany Boerboom 08/08/08 12:43 PM >>> BP 08-476 Any issues? Beth Boerboom, Customer Service Rep. Planning & Development Services City of College Station 979.764.3570 www.cstx.aov (8/12/2008) Bethany Boerboom - Re Calling for CO for 2823 Horseback Dr Page 1 From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Bethany Boerboom; Chris Haver; Gina ... Date: 8/11/2008 4:47 PM Subject: Re: Calling for CO for 2823 Horseback Dr Contacted Jennifer at Oakwood Homes via e-mail jennifer(&oakchb.com. Terry Boriskie City of College Station Residential Plans Examiner Ofc.979-764-3744 Fax 979-764-3496 >>> Mitchell Carson 8/11/2008 4:19:31 pm >>> NO to CO Sewer box it broken on clean out needs to be replaced ....... Mitch >>> Bethany Boerboom 08/08/08 12:43 PM >>> BP 08-476 Any issues? Beth Boerboom, Customer Service Rep. Planning & Development Services City of College Station 979.764.3570 www.cstx.00v WF1006714 / 001 City of College Station PAGE 1 REQ. DATE: 02/20/08 02/20/08 15:33:26 LOCATION: 2823 HORSEBACK DR LOC ID: 208714 REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4"WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/20/08 SCHED COMPLETION: 02/20/08 ******************************************************************************** JOB ORDER RESULT COM1ENTS BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE ST.kTION, TX 77840 PHONE: (979)764-3�70 + FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00000476 Date 2/20/08 Application pin number . . . 387076 Property Address . . . . . . 2823 HORSEBACK DR Property ID: 336300-0304-0110 R #: R305328 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . HORSE HAVEN PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 96193 Owner ------------------------ Contractor OAKWOOD CUSTOM HOMES ------------------------ GROUP LTD OAKWOOD CUSTOM HOMES 4060 SH 6 S 4060 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1504 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1368.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- TRAFFIC IMPACT ANAL (TAZ) 285.00 Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 553578 Permit Fee . . . . 448.00 Plan Check Fee .00 Issue Date . . . . 2/20/08 Valuation . . . . 96193 Expiration Date . . 8/18/08 Qty Unit Charge Per Extension BASE FEE 260.00 47.00 4.0000 ---------------------------------------------------------------------------- THOU BLDG, VAL 50001-100000 188.00 Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with Regular Garage Framing with 24" Minimum OSB and Interi r Anchors and ---------------------------- BUILDING DEPT REPRESENTATIVE: ---- ----46 -- ---1---------- _% A / APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STjkTION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00000476 Application pin number . . . 387076 Page 2 Date 2/20/08 Special Notes and Comments Bracing to left of front Door *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) *PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULA ION ---------------------------------------------- ---- -- ---4;---------- BUILDING DEPT REPRESENTAVIVY: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00000476 Date 2/20/08 Application pin number . . . 387076 ---------------------------------------------------------------------------- Special Notes and Comments *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 15% the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system as a SEER rating ----------------------------------------------- ---- � - - •-------- BUILDING DEPT REPRESENTATIVE 0 APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLE,-E STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00000476 Application pin number . . . 387076 Page 4 Date 2/20/08 Special Notes and Comments of 12 or more. *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK *GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND BUILDING DEPT REPRESENTATIVE: APPLICANT: ;� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00000476 Date 2/20/08 Application pin number . . . ---------------------------------------------------------------------------- 387076 Special Notes and Comments CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 ---------------------------------------------------------------------------- WATER TAP 3/4" 400.00 Fee summary Charged ----------------- Paid Credited Due ---------- Permit Fee Total 448.00 ---------- 448.00 ---------- .00 ---------- .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1198.00 1198.00 .00 .00 ------------ ---------------- ----- -- ------------ BUILDING DEPT REPRESENT APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101,TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 08-00000477 Date 482427 2823 HORSEBACK DR 336300-0304-0110 R305328 TEMP POLE HORSE HAVEN PH 3 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 2/20/08 Owner ------------------------ Contractor OAKWOOD CUSTOM HOMES GROUP LTD ------------------------ OAKWOOD CUSTOM HOMES 4060 SH 6 S 4060 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 ---------------------------------------------------------------------------- (979) 69.0-1504 Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit pin number . 553586 Permit Fee . . . . 20.00 Issue Date . . . ---------------------------------------------------------------------------- . 2/20/08 Valuation . . . . 0 Other Fees . . . ---------------------------------------------------------------------------- . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - i For Office Use Only APPLICATION FOR BUILDING PERMIT DATE�TRCCREGLVV-1 CITY OF COLLEGE STATION • �* 4 9V 1101 TEXAS AVENUE 01 APPLICATION # COLLEGE STATION, TX 77840 TEMP POLE # , CITY of COLLEGE STnTtON (979) 764-3570 (979) 764-3496 FAX NwWrigd'Drurlop+ncnrSmkoi pWWW.CSTX.GOV ADDRESS/LOCATION: 2U2 y ll LOT I • BLOCK SUBDIVISION JAUCf.&, M 2E�� SEC/PH BUSINESS/OWNER NAME: Mon O cy&zay, PHONE: q- 1 4(2; zzzo CONTRACTOR/HOMEOWNER: l.JI. y mc)U a*m �A ■ eJ PHONE: 9_T t 00 ` L504 CONTACT PERSON FOR REVIEW COMMENTS: _R\Ia1 n L ILY l(xC/�I PHONE: 2-2t O U 3 FAX: 2- , EMAIL: ----- 1 Q,1(thl _- �JVbF�iib- com ELECTRICIAN: ll;AQi b PLUMBER: (VL�J►Y�{.J HVAC: S1GOOD CENTS (Residential only): `FL✓ ACCESSORY/STORAGE MOVING RE -ROOF ADDITION NEW CONSTRUCTION` SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REM ,,ODEL/RENOVATION` TENTS DESCRIPTION OF WORK: NeW Coneb2Ac m PROPOSED USE: 1 ` STRUCTURE USE: �/� HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: /G5 TEXAS ACCESSIBILITY STANDARD (TABS) PROJECT REGISTRATION# EABPRJ I_ VALUATION: $ O , � TOTAL AREA: 20 HEATED AREA: 13(08 (Cost of Labor and Materials) 2 PUBLIC SEWER NUMBER OF BEDROOMS: J SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 2 SEWER TAP: l INTERIOR WALL TYPE: 21�WATER TAP: 31; 4 EXTERIOR WALL TYPE: ❑ SIZE OTHER TAP: FOUNDATION TYPE: SlO�o 61 ` TEMP POLE SIZE ROOF TYPE: C0111tQ • SYU �Iv GARAGE TYPE: SINGLE F-1 DOUBLE TRIPLE ATTACHED �� DETACHED CARPORT \vivtY SIGNATURE OF APPLICANT:nakw��Wkys 'If proposed work involves new comm ' ial constructioVor facade improvements/renovations to an existing commercial property, building elevation are required. .........................................................too / Official Use Only �. ���� Comments: CJt'r NO (;A*,,&..a_ UJIKPlans Examiner Zoning Official %%%l� dd'�'� 19&41'151& FV It ( S1,0� IJI�- "-J d J !9 yr + Fffi fty,' ode Compliance Information % Glazing of exterior walls ' M '/ .I s ' lation R value of exterior walls Insulation R. value of ceiling- 1 (flat areas') Insulation R value of ceiling 2 (vaulted areas/no attic) GlazingSHGC (Solar Heat (S. Gain Coefficient) � Glazing U-Factor R value of ductwork (p _ A/C SEER Rating • y. Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) , ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. • • PLANS REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning dDevdopmentSemicet COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 00 _ y%eo —]-DATE: BUILDING ADDRESS: I. Foundation Requirements- Minimum Ci Foundation Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements NAIAK A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck WdQK E. Header sizes indicated on plans N AJW F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered -Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. OK K PLAN REVIEW (*f/"" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& DevelopmentServicet COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details N OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: INAtr 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW CITY OF COLLEGE STATION Planning d Development Services ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NAI A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NkOW Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." Ai ".. a , PS_ 08 L MINER DATE IAIN, LAX) RESeheefr Software Verrsiop 4.1.1 Compliance Certificate p , Project Title: The Caballero Report Date: 02/07/08 Data filename: Untitled.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 1," Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: Horseback Drive Alton Ofczarzak Alton Ofczarzak College Station, TX 77845 Oakwood Custom Homebuilders, LLC Oakwood Custom Homebuilders. LLC 4060 State Highway 6 South 4060 State Highway 6 South College Station, TX 77845 College Station, TX 77845 979-690-1504 979-690-1504 seig @oakchb.com janalane@suddenlink.net r Compliance: 23.40/6 Better Than Code Maximum ILIA: 565 Your ILIA: 433 Maximum SHGC: 0.40 Your SHGC: 0.30 Ceiling 1: Flat Ceiling or Scissor Truss 1368 0.0 30.0 Wall 1: Wood Frame, 16" o.c. 102 13.0 0.0 Window 1: Metal Frame:Double Pane with Low-E 15 SHGC: 0.30 Window 1 copy 1: Metal Frame:Double Pane with Low-E 15 SHGC: 0.30 Wall 2: Wood Frame, 16" o.c. 97 13.0 0.0 Wall 3: Wood Frame, 16" o.c. 50 13.0 0.0 Door 1: Solid 20 Wall 4: Wood Frame, 16" o.c. 85 13.0 0.0 Wall 5: Wood Frame, 16" o.c. 164 13.0 0.0 Door 2: Solid 18 Wall 6: Wood Frame, 16" o.c. 180 13.0 0.0 Window 3: Metal Frame: Double Pane with Low-E 4 SHGC: 0.30 Wall 7: Wood Frame, 16" o.c. 190 13.0 0.0 Window 4: Metal Frame:Double Pane with Low-E 15 SHGC: 0.30 Window 4copy 1: Metal Frame:Double Pane with Low-E 15 SHGC: 0.30 Window 6: Metal Frame:Double Pane with Low-E 18 SHGC: 0.30 Door 3: Glass 18 SHGC: 0.30 Wall 8: Wood Frame, 16" o.c. 62 13.0 0.0 Wall 9: Wood Frame, 16" o.c. 118 13.0 0.0 Window 7: Metal Frame:Double Pane with Low-E 9 SHGC:0.30 Wall 10: Wood Frame, 16" o.c. 412 13.0 0.0 Window 8: Metal Frame: Double Pane with Low-E 15 SHGC: 0.30 Window 8copy 1_ Metal Frame:Double Pane with Low-E 15 Project Title: The Caballero Data filename: Unbtled.rck 42 6 0.540 8 0.540 8 8 2 0.140 3 7 12 0.140 3 14 0.540 2 10 0.540 8 0.540 8 0.540 10 0.540 10 5 9 0.540 5 30 0.540 8 0.540 8 Page 1 of 2 Report date: 02/07/08 0 SHGC: 0.30 Window 8 copy 2: Metal Frame:Douti� Pane with Low-E r * 15 0.�40 8 SHGC: 0.30 Window 11: Metal Frame:Double Pane with Low-E 4 0.540 2 SHGC: 0.30 I Floor 1: Slab-On-Grade:Unheated 189 0.0 197 Insulation depth: Off Furnace 1: Forced Hot AM AFUE Air Conditioner 1: Electric Central A04 SEER Compliance Statement The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with t* permit application. The proposed building has been designed to meet the 2006 IECC requirements in REScheck Version 4.1.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Notes: lot 11, block 4, phase III, Horse Haven Estates Project Title: The Caballero Page 2 of 2 Data filename: Untitled.rck Report date: 02/07i08