INSPECTION TICKET
PAGE 2
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 12/23/08
------------------------------------------------------------------------------------------------
ADDRESS
. : 2491 NEWARK
CIR
SUBDIV: CASTLEGATE PH 5
SEC 2
CONTRACTOR H & E
CONTRACTING
PHONE (979) 574-0374
OWNER.
H & E
CONTRACTING
LLC PHONE
PARCEL
184200-2501-0040
APPL NUMBER: 08-00000438
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING
PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
3/18/08
BB
BLDG, FOUNDATION -SLAB TIME: 17:00
3/18/08
AP
March 18, 2008 9:55:21 AM acarter.
"
03/18/2008 05:04 PM BB PDA
Strings up. Slab ground installed.
B115 01
4/25/08
RH
BLDG, FRAMING TIME: 17:00
4/25/08
DP
April 24, 2008 3:37:46 PM bcaldwell.
04/25/2008 04:11 PM RH PDA
Need proper APA for outside corner of garage.
Need bolts
and bracing on garage wall where security box
is mounted.
Anchors at doors. Draft stop all chases. Brace valleys and
hips,not off of joist. Need joist hangers upstairs.
Tape
seal all holes through TYVEK.
B115,02
4/29/08
OC
BLDG, FRAMING TIME: 17:00
'
4/29/08
AP
April 29, 2008 12:04:49 PM glsouth.
B130\91
5/05/08
OC
BLDG, INSULATION TIME: 17:00
5/05/08
AP
May 2, 2008 2:27:56 PM glsouth.
B125 01
12/23/08
BI
BLDG, FINAL TIME: 17:00
W'"—
December 23, 2008 10:00:04 AM acarter.
----------------------------------- CONTINUED ONTO NEXTPAGE -----------------------------------
tz
A!�D5
ov
WFl004742 / 001 City of College Station PAGE 1
REQ. DATE: 02/14/08 02/14/08 16:26:13
LOCATION: 2491 NEWARK CIR LOC ID: 204032
REQUESTOR: H & E CONTRACTING ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 02/14/08 SCHED COMPLETION: 02/14/08
********************************************************************************
JOB ORDER RESULT COMIENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . .
Property Address . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
1/13/09
184200-2501-0040
2491 NEWARK CIR
COLLEGE STATION TX 77845
CASTLEGATE PH 5 SEC 2
CASTLEGATE SEC 5, PH 2, BLOCK
1, LOT 4
PLANNED DEVL DISTRICT
Owner . . . . . . . . . H & E CONTRACTING LLC
Contractor . . . . . . H & E CONTRACTING
979 574-0374
Application number 08-00000438 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved
Building Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
12/29/2008 02:26 9796908470 CHB HOMES PAGE 07/12
s r•. A
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
z4M
Ace Pest Control
PO Box 4474
Bryan TX 77805
Bill To
CHO HOMES
P. 0. BOX 10710
COLLEGE STATION, TX 77M
I
979-823.7777 Dote: March 28, 2008
TPCL 712OPT
Professional Services At An Affordable Price
All bills DUE on or before the 101n of the month
foltowing date of service. Service Charge of
T YR % per month (183'o per year)
Added to Past Dues Accounts. THIS PORTION IS
FOR YOUR RECORDS. YOUR CHECK IS YOUR
RECIEPT
Service Type Of Service Linear Square Check# Amount
Date ft
ft
3/17/2008 2491 NEWARK SLAB PRETREAT 220 2981 $322.69
Current 1.30 Days 31-60 days 61-90 Days Over 90 Days
-- _ $322Amount Due
.G9 . -- -
—.... _ _... • --- —.J. -- .. -—.....--.. ..�._... $322.69
12/29/2008 02:26 9796908470 CHB HOMES PAGE 08/12
ACE PEST CONTROL
PO BOX 4474
BRXAM TX 77805
(979) 823-7777
TPCL, 71120 PT
LIMITATIOMN O.F LIABILITY
I- ACE PEST CONTROL'S liability for additional treatment of the covered property is
limited to areas of infestation to the structure(s) which occur during the term of this
agreement (with the .restrictions of the chemical label).
2, ACE PEST CONTROL shall not be liable for property that has been added to or
structurally altered unless ACE PEST CONTROL has been notified prior to the
beginning of any additions or alterations, and any additiotl.al treatment or re -treatment
found necessary is performed. Such additional treatment must be performed by ACE
PEST CONTROL at the expense of the owner.
3. ACE PEST CONTROL shall have no liability under this agreement should the
customer refuse access to the covered premises of any additions for -the purpose of
carrying out the terms and conditions of the agreement.
4. ACE PEST CONTROL shall not be liable .for re -treatment of subterranean termite
infestation caused by ABNORMAL moisture conditions such as leaky roofs, shower
stalls, plumbing, orwet soil under the structure due to poor ventilation.
5. This service agreement does not guarantee against present or future damage to
property or contents, nor provide for repairs or compensation therefore. This service
agreement is for subterranean termites only, and does not include•treatment for dry -
wood termites, carpenter ants, powder post beetles, or other wood destroying insects,
6. ACE PEST CONTROL shall not be liable for re -treatments of subterranean termites
caused by excess wood left around the foundation. For example: wood forms,
railroad ties, or any excess wood forms left in tub drains.
Licensed and .regulated by the
Structural. Pest Control Board
P.O. Box 1927
Austin, Texas 78767-1927
(512) 305-8250
12/29/2008 02:26 9796908470 CHB HOMES PAGE 09/12
ACE PEST'CONTROL
T.P.C.L. # 71201PT
PO BOX 4474
BRYAN, TX 71905
(979) 823-7777
(979) 7744736
CERTIFICATE
The following property „2491 NEW,�RX ��.
built by CUR HOMES State of Texas
County of $RAZOS the city of COLLEG STAITON
Mailing Address SAME ,Zip code 77845
was treated for subterean tertl;<ites on this day MARCH 17, 2008 and has met
with. approval. Cost of initial treatment, $322.69, is payable upon completion of work.
The treatment is guaranteed for 12 months from the date of treatment. Thereafter, this
contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection
and renewal fee of S a,30�lus tax, for a period of�ears. (see attached letter. } if
at any time during this contract a rei.nfestation of subterranean termites should occur, the
above said property will be treated at no additional cost to the owner. ACE PEST
CONTROL does not accept any liability .for any subterranean termite damage repair.
Failure to pay the annual renewal fee within thirty days after the inspection date shall be
construed as a cancellation of this contract. Any alteration. or addition to the foundation
of the above described property without proper termite treatment by ACE PEST
CONTROL Services shall nullify this contract.
Liccnsed and Regulated by the
Texas ..Department of Agriculture,
Structural Pcst Control Service,
PO Box 12847, Austin, Texas 78711-2847
( 512) 305-8250
12/29/2008 02:26 9796908470 CHB HOMES PAGE 10/12
CONSUMER INFORMATION SHEET
The structural. pest control industryis regulated by the Texas Department of. Agriculture (TDA), Structural. Pest Control
Service (SPCS), PO Box 12847, Austin, TX 78711-2847. TDA licenses the businesses, certified applicators and
technicians who perform, structural pest control work. Certified applicators and technicians must pass a written
examination in order to receive their licenses.
Pesticides must be registered with the United States Environmental. Protection Agency (EPA) and TDA before they may
be used in Texas. EPA registration is not a finding of product safety. Pesticides are designed to kill or control pests.
Your risk of harm depends upon the degree of your exposure and your individual susceptibility.
Specific health and safety information varies between pesticides and types of exposures and is available on the label
information or MS.DS sheet, which can be supplied to you upon request from the licensed applicator. 'Take precautions
when. a treatment has been performed to avoid exposure to vulnerable individuals. Pesticides may be harmfirl. i.f
swallowed, inhal4 or absorbed through the skin. Avoid breathing dust or spray mist and any unnecessary contact with
treated surfaces. If you desire specific information on precautions, refer to the pesticide label. The law requires that the
application procedures specified on, the label be followed.
If you have questions about the application, contact the business or person making the application. If you suspect a
violation of the law regarding structural pest control, contact the SPCS. In case of a health emergency, seek immediate
medical attention.
Pest control signs must be posted prior to treatment in many instances. The signs should be posted in an area of common
access at least 48 hours prior to treatment. The information. sign will allow you to contact someone who can tell you what
pesticide is being used.
If you are contracting for pest control services due to a home solicitation, you have the right to cancel the contract within
72 hours. You may exercise this right by notifying the pest control company that you do not wish to receive their service.
For general information on pesticides, contact the National. Pesticide Information Center 1-800-858-7378
For information concerning structural pest control laws, contact the Structural Pest Control Service at : (512) 305-8250 or
866-91.8-4481.
For information concerning the formulation and registration of pesticides, contact the TDA pesticide registration at (512)
463-7476 or800-835-5832.
For non -emergency health information relating to pesticides, contact Texas Department of State Health Services (512)
458-7111.
REDUCED IMPACT SERVICE
In order to minimize the reliance on pesticides and reduce pest populations, a Reduced Impact Pest Control operator may
recommend that you consider the sanitation or physical alteration of your work place or residence. It is your
responsibility to follow those recommendations. Your pest control operator may or may not offer these services upon
request. A proper inspection will provide the information necessary for you to choose the method of pest control which
best suits your situation. Many pest problems can be solved without using pesticides.
This Reduced Impact Service will include an inspection report and treatment recommendations. You should review these
and keep a copy for your records. Your cooperation in following the rccommendati.ons made by your service provider is
essential to a reduced impact service program.
Pesticides may be used in a responsible and professional manner in a reduced impact pest control. service. If you do not
want a specific pesticide used or any pesticides used at all, you must note this in writing on the contract prior to the
initiation of the service. If any specific pesticide or class of pesticides are not excluded, it may be used by the provider.
REQUIRED BY THE TDA STRUCTURAL PEST CONTROL SERVICE
Revised 09/01/07
Page I of 1
12/29/2008 02:26 9796908470 CHB HOMES PAGE 11/12
SUBTERRANEAN TERMM FRECUNS•T UC`I'fON
DISCLOSURE FOR EACH ESTiiIV
For all treatments there will be a diagram showing exactly what wgl'be treed prior to the beginning of
treatment ,Review the pesticide label provided to you at this time fdr minimgm treatment standards.
Remember that your architects or design engirit;m specifications must also be followed, unless they are
in violation of the law. Review the consumer information sheet for furthex.ibe folloion. If you have arty
questions, contact the pest control company or the Texas Department of Agriculture, Structural -Pest
Control Service, P.O. Box 1.2847, Austin, Tl'xas 7871I-2847. Phone: (512) 305-8250.
Name of Customer
Cm' State Zip
Location to be Treated.
Type of Treatment: [ ) Full f-71 rda)
A label
[ j Wood [ ] Bait f ] Commercial FtSiNle Family
is enclosed.
The percentage of the texmiticide(s) to be applied at this location is '
Warranty. Information provided must include the Co»splete,Details of any Warranty provided and the
following: Time Period of WarranNy, flenewal O, phorrs and Cost; and Obligations of the Contracting
.Parties
If the warranty does not include the entire structure treated, the areas included in the warranty are:
,r
Total Square Feet to be Treated:, j „Total Linear Feet to be Trued:''
Approximate Measurements of the Structure(s) to be Treated:
�rnL� ��•,�,5 Gy lam.
Signature of Certified Applicator or
Technician Completing Estimate
l"
a � Sf6'itfi I
Name of -Pest Control Company
Printed Name
s 3//YoS
—71
TPCL. No.
Lice and regulated andolr the.Texas Structural Pest Control Act
305-8250.
Texas DapartmEnt of Agriculture, Struehnal Pest Control Service, P.O. Sox 12$47, Austin, Texas 78711-2847, Phone: (512)
Sartiple Form •- 09/01/07
Page 1 of 2
12/ 29/ 2008 02: 26 9796908470 CHB HLINIE' PHiaE 12/ 12
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
pcwo mil..
ge ed • R` I r,
ApPiW%ni tte Ida fires t-Q-tmJ d.;_
-T Y Re, -01 A,atm$
F_Qmcla o LAB
Pft, AJT--AS-;,.MJD-MC>
Siding;. aRKK-
R-o-o�C 1C e-Q$1J10- I
Q,0 °
Y_ ALxx—
HorizontallPerimetxr Beam XX
A I.ASEL FOR ANY OTHER PESTICIDE RECOM[NOED OR USF,O HAS DEF,N ATTACHED AS PART OF THIS DOCUMfNTWARRANTY INFORMATION (IF ANY)
INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, TIDE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RF,-
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE. CONDITIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION TTIAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
�i �I � �Pi Vf R�'s 1ti,N� )I ��" r direr � . �`VI� I• � :mot b �i�x�'i�yJ��
Charges! pre -treat:
NOTES: Annual re-newal.,
C! ew TRchfthon SPCA lice"" R Mpg PT
04yl Newark Circle
Site Plan I" = 201
lba. dmfgs rRrRn rIR pp"er rN u-49�b egw
d W /r.a b bgd <ti mar ffcn UW pba R/uRt wpttl1ctW
1flelwc fo..,.. morn Ilr fnur. �... er om u pfNabn.G fldeafcLefr
dRY cb.cb wp Nlry VI b. —prwf W. ra ur p— rc
eersiftlbw UfW d "mfom b carat 4rw -4 R-kk-W C ,d J GCCr
![roof nml fpfud OTW d" bid cod". req mm o mod's fordJwf
'.d1um —regab malt , rf bm ks W Fbmkt, L1f Bwktvg C4 O"fgi
Od—jf-Ly efdm a da g.—m-coed f—pnd rw pbc
Designs That Work[
;.., Dave and Teresa Wheaton
:.A. .._............. _ 4031 Austin's Landing ph. 919-220-0851
Bryan, TX 11805 fax. 919-T18-3199
BUI`LD3Nd PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00000438 Date 2/14/08
020682
2491 NEWARK CIR
184200-2501-0040
R303642
RESIDENTIAL, 1 UNIT DETACHED NEW
CASTLEGATE PH 5 SEC 2
RESIDENTIAL
PLANNED DEVL HOUSING
170346
Owner Contractor
H & E CONTRACTING LLC
H & E CONTRACTING
DBA CHB HOMES
2306 KENDAL GREEN
CIR
3649 EAGLE NEST
COLLEGE STATION
TX 77845
COLLEGE STATION
TX 778454566 (979) 574-0374
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2581.00
INTERIOR WALL TYPE
GYPSUM
NUMBER OF BATHROOMS
3.50
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
552208
Permit Fee . . . .
673.00 Plan Check Fee
.00
Issue Date . . . .
2/14/08 Valuation . .
. . 170346
Expiration Date
8/12/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
71.00 3.0000
THOU BLDG, VAL 100001-500000
213.00
----------------------------------------------------------------------------
Special Notes and Comments
-Make sure 2nd floor
operable windows ar at least 24"
AFF
----------------------------
BUILDING DEPT REPRESENTATIVE:
----- ----- -
-�---------
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000438
Application pin number . . . 020682
Page 2
Date 2/14/08
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with Outside Garage
Corner 18" Minimum APA Framing and Interior Anchors and
Bracing on Garage Wall per Plans.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GP.
BUILDING P
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00000438 Date 2/14/08
Application pin number . . . 020682
----------------------------------------------------------------------------
Special Notes and Comments
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 15% the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUIL ING ENVELOPE SHALL
----------------------------------------- ----- -----
BUILDING DEPT RE31R� NTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00000438 Date 2/14/08
Application pin number . . . 020682
----------------------------------------------------------------------------
Special Notes and Comments
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
BUILDING DEPT REPRESENTATIVE:
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . . 08-00000438 Date
2/14/08
Application pin number . . . 020682
----------------------------------------------------------------------------
Special Notes and Comments
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
*U-Factor Ratings for Window o up to 150-o is .65, from 1501 to
20o is .55, from 20a to 25% is .54 and above 25% is .46 or
lower.
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM..
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . I . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
-----------------
----------------------------------------
Permit Fee Total 673.00 673.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1423.00 1423.00 .00
.00
BUILDING DEPT RaPR2SENTATIVE:
APPLICANT:
vr:
i
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . .
Application pin number . .
Property Address . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . .
Property Use . . . . . . .
Property Zoning . . . . . .
Application valuation . . .
08-00000439
102921
2491 NEWARK CIR
184200-2501-0040
R303642
TEMP POLE
CASTLEGATE PH 5 SEC 2
RESIDENTIAL
PLANNED DEVL HOUSING
0
Owner Contractor
Date 2/14/08
H & E CONTRACTING
LLC
H & E CONTRACTING
DBA CHB HOMES
2306 KENDAL GREEN
CIR
3649 EAGLE NEST
COLLEGE STATION
TX 77845
COLLEGE STATION
TX 778454566
(979) 574-0374
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 552216
Permit Fee . . .
. 20.00
Issue Date . . .
. 2/14/08
Valuation
0
----------------------------------------------------------------------------
Other Fees . ...
----------------------------------------------------------------------------
. . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary
-----------------
Charged
Paid Credited
Due
Permit Fee Total
----------
20.00
--------------------
20.00 .00
----------
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
For ORcVse only
Fri
APPLICATION FOR BUILDING PERMIT DATEI 10- v ►JTRCC REG C
1101 TEXAS AVENUE APPLICATION #
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX TEMP POLE #�
CIT°Y QFSC.- EGE. STATION yyyyy� CSTX.GOV
P(i{nniiig Developni Srvica /
ADDRESS/LOCATION: Z�� I NJtwQC..k_ CI'a . ✓
LOT _q✓ BLOCK _L_1SUBDIVISION jbt("Ye to 44-4L `� SEC/PH Z
BUSINESS/OWNER NAME: \A Ar E PHONE: S'?%* - c3-t%
CONTRACTOR/HOMEOWNER: \Ae_ck*\,, ' 6,_Q^se+-.ck PHONE: Sig{ - 031 �}
CONTRACTOR ADDRESS: Q, o • Sox \ c1 o Co\�e,ye S'�.�;� `�c '7 T g�to
ELECTRICIAN:
PLUMBER: liar A
HVAC: San\\ C.cee.W_ GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) Y NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE:
HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT¢EGISTRATION# EABPRJ
VALUATION: $ I%Jt , UTOTAL AREA: g397 HEATED AREA: Z$ T
(Cost of Iffabor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
1�
SEWER TAP:
SIZE
X] WATER TAP: 314+11
SIZE
OTHER TAP:
TEMP POLE
GARAGE TYPE
SIZE
SINGLE
ATTACHED
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE F)-k-1 TRIPLE a
DETACHED 0 CARPORT •0
C�vI�S�M
C C.K.
S \cb CO c�cca+re,
C�QoS:�e
SIGNATURE OF APPLICANT: C,
*If proposed work involves new comm cial construction or facade impr vements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
:Z—A -2-/1_o6
..-- jCIP Plans Examiner
Acc.erS
Zoning Official Fire Marshall
CgmLnents:
ES r NO 19 u M i A! PTr A l J:K4-
A,,x,c ,r A-4C p )a,wS
L=
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
3
15
�
- 4
.bs
�
13
. PLAN REVIEW
(*f/q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning dDevelopment Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# DATE:
BUILDING ADDRESS:
I. Foundation Requirements- Minimum City Foundation Standards
N O
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
MAIM
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NAM
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
0.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size,
location indicated on plans
grade &
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
OWK
A/ K
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
planningdDevelopment Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
N
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N O
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required .
4. Arc fault protection for bedroom circuits
5. Panel location
(*f/q"
CITY OF COLLEGE STATION
Planning cd Development Service)
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room direct) .off garage
11
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
7
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
W011K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N ,
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side intersectin street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
C__ t
PLANS EXAMINER
a /g -0 t
DATE