HomeMy WebLinkAboutRES2008-00424, 08-425FINISHING NOTES A More Home, Less Money SHEET INDEX COVER SHEET G-1 GENERAL NOTES G-2 SITE PLAN C-1 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 DETAILS S-3 BRACING PLAN S-4 FRAMING PLAN S-5 ROOF FRAMING PLAN S-6 DECKING LAYOUT S-7 ELEVATIONS S-8 FRAMING DETAILS S-9 ELECTRICAL PLAN E-1 FLOOR PLAN A-1 FLOORING PLAN A-2 CABINET LAYOUT A-3 PLAN APPROVAL APPROVED INITIALS I DATE ADMINISTRATOR / SUPERINTENDENT / CUSTOMER / NOTICE THIS SET OF DRAWINGS FOR A HOME IS THE COPYRIGHTED PROPERTY OF STYLECRAFT BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL OR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF THE DESIGNERS. 1 ST PLAN PREVIEW SCALE:3/32'=1'-0" r-------------------------� i I I I L------------� 2ND PLAN PREVIEW SCALE:3/32'=1'-0' 1 Notes COMMENTS G-1 CFRONT ELEVATION SCALE:3/32"=1'-0" (7/31/2008) Gina Southerland Re Calling for CO for 2915 McLaren Dr.v Page 1 ; From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Christina Court; Gina S... Date: 7/30/2008 3:56 PM Subject: Re: Calling for CO for 2915 McLaren Dr ALL OK. PAUL >>> Christina Court 7/30/2008 12:48 PM >>> bp# 08-424 any issues? Christina Court CSR Planning & Development City Of College Station 979.764.3570 Apr.11, 2008 3:36PM Stylecraft Builders, Inc. No, 8957 "Shielding A Protecting Homes Against Pests" Renewable 5 Year Subterranean Termite Retreatment Agreement (Does not cover any other species of Termites) This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph). �1GvcN �/_-o-Uie Customer Name Date Billing Name if different "y& .rr .& GL 4'l' e.IV Street Address of treated structure Billing Address if different City State Zip Code City State Zip Code Home Phone Work Phone Type of Treatment Partial Bait _ZPre-'heat Treatment for: _Prevention Control of Subterranean Termites Notes; Initial Termite Cost — Additional Renewals Paid Other Tax f- Cash_Check# Total S Payment S 4 Balance $ /� r Dg-4a�! Credit Card: Type Exp. Date Card Number 5 Year Subterranean Termite Re • RP Lee Termite and Pest Control will retreat the structure for Subterranean Termites at to cost to the customer, if an infestation of Subterranean Termites is found, as long as the original treatment is paid in full and the customer is current on their yearly renewals. This Agreement will expire in one (1) year unless the customer elects to pay the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termite and Pest Control may approve additional warranty years after the five (5) years with an additional increase in the yearly warranty fee. The guarantee does not cover any damages to the structure or contents of the customer. The customer agrees to control all conducive conditions that may cause rcinfestatiot. If the structure is modified, added on to, altered, or if the soil treatment around the structure is removed the customer must contact RP Lee Termite and Pest Control and pay for additional treatment in order to keep the guarantee in effect If the customer does not pay for additional treatment the retreatmcat guarantee can be cancelled. ReneEvaLEea Customer may elect to renew the retrcatment guarantee for additional years. The renewal fee is S 0 plus tax. The renewal fee is due on or before the annual anniversary date or paid S,_,,-" plus tax every third (3) month with inspection. Maintaining the The customer agrees to correct all eondusive conditions, at owner's expense, as they exist or as they occur in the future in order for the guarantee not to be cancelled. Customer will make the structure available for inspections and treatments as requested by RP Lee Termite and Pest Control. $glggpg�Qn; RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times RP Lee Termite and Pest Control deems necessary. RP Lee Termite and Pest Control recommends that the customer call and set up an annual inspec- tion at the time of customers yearly renewal. 'hansfg[,, This agreement may be transferred to a new owner with the payment of a transfer fee of Ste/ , copy of the Wood Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest Control. This Subterranean Termite Aetreotmgnt nnarantaa dais pot nrnvenr and is nest intended to cootroLother fora of Termites O j=zd. Eq►mosan. etc.'. Wood Bering Beetles. CmWnter Ants, Carpenter3.le.- Wand Rot, Fun2uL NOMv. or any other wood de"ng insects or organisms. r gg-, In the event of any dispute arising out of this agreement or any other services performed or not performed the parties above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final, binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration Act Limitation of Llabiiity: Landscaping acid grass next to the slab may be damaged during treatment, carpet may need to be pulled up in certain areas around the home, drill holes may need to be made in floor coverings such as file or linoleum or in cabinets next to pipe areas, sod holes may need to be cut in walls. Customer agrees not to hold RP Lee Termite and Pest Control liable for these damages, or treatment techniques, or other damages that may occur during treatment. Agreement: This Agreement shall be the entire agreement between customer and RP LecTcrmite and Pest Control. If any part of this agreement is found to be invalid it shall not affect the validity of any other part of the Agreement. We are licensed by the Shatctnnral Pest Control Beard - 33341usdalune. Suite i-530 Anson. TX 21201512-305-8250 u61t, RP Lee Tc�A & Pest Control Cert. Apl.n Custol6er Signatbrc Date Apr.11. 2008 3:36PM Styledaft Builders, Inc. No.8957 P. 6 0160 Applovn! NO. SM-052'1 New Construction Subterranean Termite (alp. tml�) Soil Treatment Record 7t11s torn is t omplotod tho tt�ancod l�rnt Gontrat Comnr,n� _. - — }�µs f rm is d plot !a y 1 colt= td�unnaWXl tti eatmal0d to IIyp:apo 16 mlaultu Rar ratpOnrA.1l�dudr0 U1o'4riii lift rgrwhtn� o,JINC11C71C. toarchl�y tvoutetl to &" a%0jftVQ aid 0 HUD may rwt wriWo ViAm a dalidta 11 n, . WO Mou of r+or �tGrea rn mom 0�r:lurm�url�a�a�l;Apys a euavn&/trs 14 Ctdeoeryonmet is nuadler. ' dat to C%-.tivn 24 CF1a '00.D20d(b)j3) rey�res that tha sites ke HUD hwuW ctrvcsurao must W Lvo W tam11W htlatrtls. This Initimatlon co3lwY'on wv.lte3 urtosmthoft� � tmW ew an =Aol tad Pwt Co &W *AP5�r Aothxmad aA r equltad traatm W 1ff tcm�loo. 311d Utat 019 Wilacr µwataow the Uowad aloe Lprej oue year. DWI&a. poet wnuol Cpinpmide morgtapo londam, hanotvye+% and HL'b as a rewnl or treau mt xr µl0a4a jLUU*H Vari ud, uw adufflaUun cdcom. . 7110 in&.MAt.ft c nd o ..kk red lxafidortb+t _ ThtbtaportttWmntAtlJUtorinraera°'1"'Yip°rtJ°`a6tothoturttdetonproporAo(new)t1ku11ruGwr•eawsMhrr zoUtroatrlontlarpr6v'onuonaa„hwrranaa� t9lmitb inloctatim Is cpedfiod by 11w bjdor, arotdtoot, Pr roquk°d by lha WNW, archl1eC1, FWaVA. AU contrails for aorvicoo Oro WhVOQr 910 P091 Control t?parator and buUder, urtlo&. "tad othorwim FAXan 1: Gonaraf rn(osmatdann((Trwththl q CGnpanr I111WIn w) cwwnyNOlna r.. r�..�•� GC� �iL�srZC �+rCsr Til_��-- —�-� -- W.— .�t GomWy AAdrw d p _ 7.Z ComWny Hualnacc Wourtao NO. / �/ D 4 Cumvany rttww No. —.1 Le- FW1NA Caro No. (V any) _ SeatloA 2s 8ulfder IhANOIoUOn �� PlttulrJ Nil. Company Nano—--^--- 8ectlon 3. property Intarmatinn 2 Location of shichxo (a) TtoutW (3lroot ArUvQ at Lo171190A)eon, CO- 6WO and zlp) 77 y T}pd of Conouctioa (mcra titan caw box mvY b0 0110chod) t-PI Slab U 8seomnn: , Crawt OPtor - — A mate DOPIA1 of FOOM9; t3trf Ply Fidw ,� WAda Typoof Fill Soatlan a: Ystmabmnt Infcrsastton a _,0 Ce - Drag(i) of 7roafmant(a) w Brand Nana or Frnductf&) tA0 g, 9PA Replstratlon No 1p Apprortmofo Final Wix SduWts % _5v APpAoxllnatp:die0!Tro0lrtl--Aran: Ski -IL uwrft. uraurr o!MdconryVotilu_�_�_� Appt04rna110 TOW Wane of Srdutlan A010d Was trootmufr, conoutad on axWwr? � Yac M No C berytco ASrpont:rnt AvallnUoT Yes 0 MNote. C, OMO oleic IM toqutro eeM agroarnenta to be iaauol Thia harm duay nut prol rnpt stdto :m- At=-11Wda (List) Corlmlentr �_� lvaloa of Appllrxtar(sl Cjancauon W. (I! rogt*od by State taw) 7'/ Ttw appuca(or hart used a product In Aw-69A l LV W'Sh U10 Aroduct tobOl and 9tato requlramotos. AA tro3trtwnt rnaloru,c Wd mothods u50d comply whh ctata and fadorm ro ftrlA`JOna. AJthodzad 012naturu -- — ^-- loom MJD wti Prv'up�n tntso erttms r+M ftltamAnk Cer1wAM1 mny �y1dt N pyxrnal :�rl',v �i.Jn...,a„in tg U.S.G- unI 1010 101'l: 11 11.11 r ri?r Y"") Irym HUD-WCA-V" (W.'( %a; rwlm NFCA40-0 mar cUk bo uwd Apr. 11. 2008 3:36PM Stylecraft Builders, Inc. No, 8957 P, 8 SUBTERRANEAN TERMITE PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATE Licensed and regulated under the Texas structural Past Control Act RP LEE TERMITE & PEST CONTROL PO Box 9423 • College Station, TX 77842 • (972) 690-8622 • TPCL #11486 CUSTOMER INFORMATJON: / Name: +/ 4 de., Oct _ Phone #1: Phone #2; Address:2913 A C L.410`w City: C , 5 state: 7.' zip Code: 4,Y� Location to be Treated: For all treatments there WR be a diagram showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If you have any questions, Contact the Pastcant[ol comrtsry or the Texas Structural Pest Control Board, P.O. Box 1927, Austin, TX 79767.1927. Telephone number (512) 30"250. Before conducting a termite preconstruedon treatment, the company will present a complete diagram of the structure including construction details. When construction prevents performance of a full treatment, in accordance with a bid far full treatment, any change to a partial treatment by the company providing the treatment wig be permitted 'd the owner of the structure or the person in charge of the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amended diagram showing the exact areas to be treated, Copies must be sent to the owner of the property within seven days of the application. //�� notes:1%711ACAet �Clo""¢c c y�oSc'e 2-6 .' Type of treatment proposed; (check all that apply): ❑ Full tif Partial Wood a Bait o Commercial Mingle Family Total square feet to be treated: l , Total linear feet to be treated: Z&S . Approximate measurements of structures) to be treated: A label of �Uh A C 4( term cufe(s) Is attached. The percentage of the termhlclde(s) to be applied at this location Is °A. Estimated amount of terniticide to be applied: F/�`N gallon(s). THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED ON BACK (SPCB10d). THE BOARD APPROVED SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED T0, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT SERVICE. Complete details of warranty (ifany) including time period of warranty, renewal options and cost, and obligations of the contracting parties is attached. If the warranty does not include the entire st oture treated, the areas included in the warranty are (specify): A consu information sheet Is also attached. cd __S@naturaofC r Technician Printed Name Date SI nature of Cuilimer Verifying Receipt of This Document Date rr at c STPR Ss62 nuoaor white copy - Service Provider Wlow Copy . Customer corm pealed W P,;rA W SWwkm c cwk2am I-mo-W-Wa, NM rA 0907 Service Treatment Invoice 2oute: U Map Code: itartTuae: am/pm FiaishTime: amlput rype of Service: tier Regutar Follow Up OneTlao Chartty Service Adore Name: Address: City: (' t °i TX ij, y--) Phone: Billing: Bate: % 'u Fnegiwncy: B?d1 Q S SW Structure: Crawl WB Appoint. Time.• amlpua Y CWAbo Pets: Dog(s) Cat(s) Birds) Fist, .i f Cost of Service $ % J Tax S Total Due S / ` a - Payment $ Balance $ PEST PROBLEMS: —,Z;4,V X- V eff DIRECTIONS INSTRUCTIONS: EQUIP. METH. LOCATIONS) WOOD DESTROYING INSECGS PRODUCT QTY TARGET PEST(S) "W,r.,r ft Payment by: Cash ❑ Check ❑ # Credit Card D PAYMENT DUE UPON RECEIPT TeroddorSC-Fipranll.06/o Subtetrraneaa Termites, Ants Size of Task Posted TermiderSOXV-Piprooi1.06'/ Subterramon'rermkcs. SizeofTaak Posted IforR-care)-D1sedium Waboratc 7elrah)4ate 50% d N� SabtcrramyNFormonao/Drywood 7ermilee, CorpenterAnts, Beetles, Vested l invader HPH-Uaygon 1 % Demon WP-Cj�ano-PhenosDphenyl DictWoeyloyetolimponecarboxylate 1% Ternpo Ukra W-Cyltulbrin .1125% (Rest) (gen. surface spray, spot, mist, crack dr erevke) Talslar I:L Blrenthrht .2% blaxfotoo-Hydramethylon 19LZ.i5o/. Cykick CS Cylluthrin .05% Phoutora.5% 'leagard•Pennelhrin .5% Saspead SC-Deltaaetnrin 4.7S% (REST) Nyguact-Mcdoletsoxy 10% (REST) Ertdte R Pyrelhrin .05% Fostrat-BromeltAiu Al % Bak Station -Large Small Glue Boards Yro-control Plus Pyrtarins.50% Masterline Bifembrin .46% CarpenterAnbs Spiders, Crickets, Millipedes, Beetles,Tcrmttes. Cockroaches, Millipedes, Suwbug% FlUn4'11eka, Mosgsitos,Pillbugs, Silverfish,Beea,Anls,CarpeohrAuts,Seorploos,Spd ere Ants (Exupt Pharaoh), CoeBreaches, Crkkels, Earwigs, Millipedes, Flies, 61vk Flies. Bmlks, Pillhtrf, Silverfish, Spiders, Goats, Hornets, Wasps, VellowJaekets. Ante, Cootipedes, Cockroaches, Crlekds, Grassboppera, Scorpions,'ficks, Silverfish, Spiders. Pharsoh Ant% Crickets, Carpenter Art% Lg. Roaches, Varlcly of Asts. Spiders, Seorpkms,AnU6 Carymler Ud8,CarpentW Dcca, hunches, Or ckets, Silverish. PhorohArrts, Variely orAnts, lloacbes. Flcas,'lTcks, Aryls. Ccatipcdes, Carpt veer Anls, Bees, Wasps, Carpenter Dees, Cockroaches, Crickets, Files, Earwigs, MBlipedes, Beelles, Pillhu91- Fleas, Bees, Beetles, Roaches, Crlckcts, Lice, Flies, Scorpdons, Mcks, Wasps. ICR-Growth Regulator -Fleas, Roaches, Crkkets, Flying Insects, Stored Product Pests. f leas. Mice, Rodeub, Rats. 61ice, Rodents, hats, Bug Nlenitors. Heasellies, Mosquilos. Moths, Pleas, %hasps, ftorset%'11e}ts,Cockrnaehcs. Spltlers, Anls, Roaches, Sliertiisb, Far•aigs, Fleos, Scorpions i"Wrilent: A -Compressed Sprayer'P-Power Sprayer B-Bait Dispenser BS-knit Station BT-Bail Trap D-Acrosol Can ];,-Glue Board H-Band Duster S-Spreacler F-Fogger "I-Foamer AC-Actisoi unit Other Ldicsitions: I -Kitchen 2-Balks) 3-Bedrooms- 4-Dining Roam 5-Utility liaoiage 7-CommonAreas 8-13arage 9-Perimacr of Structure 10-Attic 11-Yard 12-Un&,r flume 13-Warelcouse 14-Office 15-Exposed Wood 2' up from Slab Other Method of,nVatments: CC -Crack & Crevice SS -Sub -Slab Injection VT -Void Treatment BP -Bait Placement BS-Broadcast Spray PB-Perimeter Barrier BV-Brick Venire NW -Wood Treatment PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried. Lteenced by the Texas Department of Agriculture Structural Pest Control Service - P.O. Box 12847 • Austin, TX 78711 - 512-305-8250 SERVICE TECHNICIAN: f.ACr CUSTOMER SIGNATURE: f�rf� ' / DATE: J Please review the Customer information on the other side of Invoice P.O. Box 9423 - College Station, TX 77842 (979) 690-8622 - Fax (979) 690-8840 0 00 f i 3 w W iw PREPARED 7/30/06, 12:15:55 INSPECTION TICKET PAGE 8 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/30/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 2915 MCLAREN DR SUBDIV: SOUTHERN TRACE PH 2 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 579530-0207-0120 APPL NUMBER: 08-00000424 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 3/20/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00 3/20/08 AP March 20, 2008 10:40:21 AM glsouth. 03/20/2008 05:04 PM BB PDA Strings up. Slab ground installed B145 01 4/03/08 RH BLDG, EXT. SHEATHING FASTENER TIME: 17:00 4/03/08 AE April 3, 2008 11:59:09 AM glsouth. April 3, 2008 4:23:23 PM kwolfe. OSB in the storage room needs nails 4" on center at edges and 12" on center in the field by framing B115 01 5/02/08 BB BLDG, FRAMING TIME: 17:00 5/02/08 AE May 2, 2008 10:58:19 AM glsouth. 05/02/2008 04:18 PM BB PDA Need bottom row of nails, 411 o.c. in storage room. Need anchor bolts inside entrance to storage room. Both by insulation. Note: all 2nd floor operable windows, must be 24" aff. B130 01 5/06/08 BB BLDG, INSULATION TIME: 17:00 5/06/08 DP May 5, 2008 1:51:50 PM glsouth. TUESDAY AM 05/06/2008 12:24 PM BB PDA Need anchor bolt inside door at storage room, as noted on previous inspection. Need moisture barrier over OSB on front house. B132 01 5/13/08 BB BLDG, SHEETROCK FASTENER TIME: 17:00 5/13/08 DP May 12, 2008 3:23:57 PM acarter. 05/13/2008 10:14 AM BB PDA Need proper fastening schedule. Plans call for 5d nails (or equal) at 7" O.C. through out. B132 02 5/14/08 BB BLDG, SHEETROCK FASTENER TIME: 17:00 5/14/08 AP May 13, 2008 4:01:42 PM acarter. B125 01 7/30/08 BI v5 BLDG, FINAL TIME: 17:00 July 30, 2008 9:35:41 AM glsouth. -------------------------------------- COMMENTS AND NOTES -------------------------------------- T�C whu(p�i1 �V� WFl004709 / 001 City of Coll6 e Station PAGE l REQ. DATE: 02/14/08 02/14/08 15:18:53 LOCATION: 2915 MCLAREN DR LOC ID: 208578 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/14/08 SCHED COMPLETION: 02/14/08 ******************************************************************************** JOB ORDER RESULT CONN=S BUILDING PERMIT] CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00000424 Date 2/14/08 Application pin number . . . 741944 Property Address . . . . . . 2915 MCLAREN DR Property ID: 579530-0207-0120 R #: R305138 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SOUTHERN TRACE PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY CLUSTER DEV Application valuation . . . . 112860 Owner ------------------------ Contractor BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1710.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- TRAFFIC IMPACT ANAL (TAZ) 405.00 Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 552315 Permit Fee . . . . 499.00 Plan Check Fee .00 Issue Date . . . . 2/14/08 Valuation . . . . 112860 Expiration Date . . 8/12/08 Qty Unit Charge Per Extension BASE FEE 460.00 13.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG, VAL 100001-500000 39.00 Special Notes and Comments *IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ------------------------------- BUILDING DEPT REPRESENTATIVE: ------ -- --.- -•---------- .� J?td /Yll�� APPLICANT: F BUILDING PERMIT t CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00000424 Date 2/14/08 Application pin number . . . 741944 ---------------------------------------------------------------------------- Special Notes and Comments ROOM. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 1501 the Values Shall be R-13 and R-30, above 150-. the Ceiling Insulation is Increased to R-38. *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR --------------------------------------------'- ------ ---- - -- ------------ BUILDING DEPT RW ATIVE: APPLICANT: BUILDING PERMIT r CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00000424 Date 2/14/08 Application pin number . . . 741944 ---------------------------------------------------------------------------- Special Notes and Comments TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH ------------------------------------------- ------ --- - -- -•----------- BUILDING DEPT REP ESEN ATIVE: 0 APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00000424 Date 2/14/08 Application pin number . . . 741944 ---------------------------------------------------------------------------- Special Notes and Comments SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 499.00 499.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1249.00 1249.00 .00 .00 ------------------------------------------- ---- -- '------------ BUILDING DEPT REPRFSENTJ'IVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . 08-00000425 Date 835675 2915 MCLAREN DR 579530-0207-0120 R305138 TEMP POLE SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY CLUSTER DEV 0 2/14/08 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc GS Permit pin number 552323 Permit Fee . . . . 20.00 Issue Date . . . . 2/14/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------- BUILDING DE APPLICANT: For Ofte Use Only APPLICATION FOR BUILDING PERMIT DATE :�Ih� TRCCREG 1101 TEXAS AVENUE— �-i COLLEGE STATION, TX 77840 APPLICATION # CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX TEMP POLE # UU "fin Planning d Developmnn Sm�int WWW.CSTX.GOV ADDRESS/LOCATION: 2-915 MGLAgetJ �Q . LOT I Z VIBLOCK SUBDIVISION Gov HE12N T(LA,C.E `/ SEC/PH 2 / BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext. 120 FAX: 690-0348 EMAIL: ewivagg(�stylecraft-builders.com ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: -- Control Temp GOOD CENTS (Residential only): No ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: Conventional Framing PROPOSED USE: Sinale Familv Residence WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS ENGINEERED HOMEt WNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROV 4L: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ IIZ ,$6fl ✓ - TOTAL AREA: 194q HEATED AREA: 17/0 (Cost of Labor and Materials) � C' q � PUBLIC SEWER "� SEPTIC/TREATMENT SYSTEM QX SEWER TAP: 4" SIZE �X WATER TAP: 3/a" SIZE OTHER TAP: X TEMP POLE 0i �� �� GARAGE TYPE: SIZE SINGLE ATTACHED FX NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: `1 INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: DOUBLE SIGNATURE OF APPLICANT: V !,j- I / . *If proposed work involves new commercial con structiaff orr commercial property, building elevations are required. Official Use fe;� _08 5 �1QS Plans Examiner Composition TRIPLE a ,ARPORT 2 Jill bb e iftrovements/r6dove Zoning Official s to an existing Fire Marshall Comments: _� Cr NO Energy Code Compliance Information % Glazing of exterior walls l Insulation R value of exterior walls R13 / Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 / Glazing SHGC (Solar Heat Gain Coefficient) .35 Glazing U-Factor 53 R value of ductwork R6 / A/C SEER Rating 13 Protection Against Subterranean Termites ❑ Chemical Termiticide Treatment (Soil Treatment) Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other E *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. ! PLAN REVIEW (*f/ ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning dDevelopment Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 0 _ y a'J 7 7 DATE: _ BUILDING ADDRESS: I. Foundation Requirements- Minimum City Foundation Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex JbK NA 1. One -hour rated extending to roof deck IVAO K E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H.. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of ro ertline to have rotected o enin s. F/WK PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details NAKK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NI 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location i CITY OF COLLEGE STATION Planning d Development Service PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N AfgK B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N O A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) y B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert an .flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER .2- /Z,-b 8 DATE s Permit # Permit Date REScheck Software Version 3.7.3 Compliance Certificate CNJ( Project Title: 1711 Report Date: 02/11/08 Data filename: S:\ACAD\RESCheck\1711.00-Master.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 11% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: College Station, TX 77845 Stylecraft Builders, Inc. Stylecraft Builders, Inc. 4090 SH 6 South 4090 SH 6 South College Station, TX 77845 College Station, TX 77845 979-690-1222 x127 979-690-1222 x127 jsaucier@stylecraft-builders.com jsaucier@stylecraft-builders.com Compliance: Passes Maximum UA: 644 Your Home UA: 507 — 21.3% Better Than Code (UA) Maximum SHGC: 0.40 Your SHGC: 0.40 Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 2: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 3: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 4: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 5: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 6: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 7 Twin: Metal Frame:Double Pane with Low-E SHGC: 0.40 Window 7 Twin: Metal Frame:Double Pane with Low-E SHGC: 0.40 Window 8: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 9: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 10: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 11: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 12: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 13: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 14: Metal Frame:Double Pane with Low-E: SHGC: 0.40 1711 2254 13.0 0.0 163 16 0.670 11 16 0.670 11 16 0.670 11 16 0.670 11 4 0.670 3 4 0.670 3 16 0.670 11 16 0.670 11 4 0.670 3 16 0.670 11 16 0.670 11 4 0.670 3 13 0.670 9 3 0.670 2 4 0.670 3 Page 1 of 2 Window 15: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 16: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 17: Metal Frame:Double Pane with Low-E: 6 0.670 4 SHGC: 0.40 Window 18 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 18 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 19: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 20: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 21: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 22: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 23: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Door 1: Solid: 20 0.500 10 Door 2: Glass: 18 0.440 8 SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: 873 30.0 0.0 31 Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0' 127 0.0 132 Floor 2: All -Wood Joist/Truss:Over Unconditioned Space: 24 13.0 0.0 2 Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. Thpnposed building has en designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the r dato uire s I' ted in the REScheck Inspection Checklist � 5E(icQA t 2 I! p$ Builder/Designer Company Name Date Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 1711 Page 2 of 2