HomeMy WebLinkAboutRES2008-00400, 08-401a,, 4 W-,
"Aid jMqp).
OA#
�leg�t
PREPARED 6/03/08, 11:59:52 INSPECTION TICKET PAGE 9
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/03/08
------------------------------------------------------------------------------------------------
ADDRESS 1215 EBBTIDE CV SUBDIV: SOUTH HAMPTON PH 2
CONTRACTOR ELEGANT LIVING HOMES, INC PHONE (979) 823-0638
OWNER . . PHONE
PARCEL . . 579020-0204-0040
APPL NUMBER: 08-00000400 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 2/28/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00
2/28/08 CA February 27, 2008 2:47:02 PM acarter.
B100 02 3/03/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00
3/03/08 AP March 3, 20.08 8:13:20 AM kwolfe.
03/03/2008 05:06 PM RH PDA
Strings up, slab ground installed.
B115 01 3/26/08 RH BLDG, FRAMING TIME: 17:00
3/26/08 AP March 26, 2008 11:26:48 AM glsouth.
'! March 26, 2008 4:52:10 PM kwolfe.
B130 01 3/27/08 RH BLDG, INSULATION TIME: 17:00
3/27/08 AP March 27, 2008 8:45:21 AM glsouth.
March 27, 2008 3:56:25 PM kwolfe.
B125 01 6/03/08 BI BLDG, FINAL TIME: 17:00
lao June 3, 2008 9:30:13 AM ccourt.
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
66
#0526 P.002 /002
02/27/2008 10:07 9798231606 ELEGANT
Feb 22 DS 10s3sa Paul Williams Land Surwou 9797797672
7M
NOrY ucket On%
Soalee ! ` a ,3p' 6/b' bevy JV 40-o9'7S' E B7ag. (cav #w �/�'
Rod t%� AW Me..
IV �49'13' £ 87.e9' iAcknv/i
f0' p, ,yr
- - - - - - - - - - - - - - -
------------
- - - - - - - -
Got 4
�..
s4s•
i �
i
f
f
cot s
o
/�dI7i7S
ssa•
LZ.—L
�'� fa`•'.
6 1/779Abd Rkt
5� �d
SO
h=JLiQr7r7•
fig-
8�:MT-
w7A
LADIf 3
~ 1
t
7/2 6bn
�W
Farm Survey
1215 Ebbtide Cove
Prepared for.• Elegon t Living Homes, Inc.
Suing a// of Lot 4 (FOUR), OApc.* 4 (FWP) .So4fl N HWPrCW SU6D/1//S/OA/, Pi/RSE 2, an odd/tion
to the GYy of Cp//9ge Station ercww County Texa:51, q=Ord;ng to the p/ot .ceded �n Yo/unre
�1 Page f 19 of the Off;a;a/ Records of grozos County, to
pond 71�%//lams. Reg�ietarad Pro7tes ens/ Lone Survayer Aim 574,3 do hejw6y cer6Yy that lids plot
nspresenLs bhe results of a svrvqy perlorrrted an trhe ground, under nw Sw0rVzMOn on
f'ebruory 15y 2dOB, And !s hus orW cwrnrt to the best of my OW
to
/ further csrtlfy that no ;mprawsrnents an th;.s Pr*Per(Y ft=MOCh CM odjoc&nt praper{j, nar dp
mry �inproremeoats on odprent prgperty cwcSroocah on to this
Property, a xcePt os Shawn.
LAND f SURME)oI NG Co.
30077 �S�w� MOM SUVet. Ste. 206
9F79- 7�w ox 2
Abftr
awernafar, b busx! on . m. rO M 4W to
pkf caft 1* ewl opyl .
7%s aonp� WOW pf"Pdr0d 44% M& bMrAMW orjpgWpfMW
n � =Ii*VM t n� o.F AMAP m�
WFl004385 / 001 City of Collegq.--S_tation PAGE 1
REQ. DATE: 02/13/08 02/13/08 13:51:06
LOCATION: 1215 EBBTIDE CV LOC ID: 209068
REQUESTOR: ELEGANT LIVING HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 02/13/08 SCHED COMPLETION: 02/13/08
********************************************************************************
JOB ORDER RESULT COMMEgTS
06/04/2008 16:55 9798231606 ELEGANT
A Termites
P.O. Box 5481, Bryam, TX 7785-5481
979-589-1203 Oft 979-589-3655 Fax
A 1 Tem ite *tconl ine . net
Treatment Date:
2/25/2008
Treatment Time:
10:00-11:00
Guarantee:
2 Years
Renewal bate:
2/25/2010
Renewal Price:
$215.50
Property Name & Address
Property Owner
1215 Ebbtide Cove
College Station, TX 77845
#0862 P.002./006
Invoice No.:
2008-2014
Payment Terms:
Due Now
Tank Size:
325
Job/Project No:
EPA Reg, No:
81824-5
Billing Name & Address
Elegant Living Homes
P.O. Box 7063
Bryan, TX 77805
Description of Preeonstruetion Treatment
Gallons
Tarries
Chemical A Percentage
Slab Area
Amount pup,
Residential House Slab - Horizontal
317
0.98
AAaxKrhor SC @ 0.06%
3,171
443.94
Foundation Partial Pretreatment for
Subterranean Termites
Total We $443.94
Receipt of Service Signature
A-1 Termites wants to thank you for your business.
We now offer Bora-Care Wood Pretreatments in place of the foundation pretreatment. if you
would Pike more information please contact our office at 979-589-1203.
Please Pay From This INVOICE
06/04/2008 16:55 9798231606
W
ELEGANT
#0862 P.003 /006
SUBTERRANEAN TERMITE PRECONSTRUCTION
DISCLOSURE FOR EACH ESTIMATE
For all treatments there will be a diagram showing sty what will be treated prior to the beginning of
treatment. Review the pesticide label provided to you at than time for minimum treatment standards. Remember
that your architects or design engineers specifications must also b, followed, unless they are in violation of the
law. Review the consumer information sheet for further information. If you have any questions, contact the pest
control company or the Texas Structural Pest Control Board, P.O. Box 1927, Austin, TX 78767-1927.
Telephone number is (512) 305-8250.
Contractor Name. Ekgant Living Homes Location Name: Property Owner
Contractor Address: P.Q. Boa 7063 Location to Treat: 1215 Ebbtide Cove
Bryce TX 7705 College Station, TX 77845
Type of Treatment [ J Full [XI Partial [ ] Wood [ ] Bait [ ] Cormnercial [X] Single Family
A label of Mayor SC Tertrtiti
Ci*5) is enclosed_
The percentage of the termiticide(s) to be applied at this location is: 0.06%
Warranty Information provided mi#w ird&& A6e GompjM ,Dete&S of any WarrQn y provided
and the following: Tbue Period of iWarrasuy; Renewd Opdons and Cost; and Obligations of
the Conow ng Parties.
If the warranty does not include the entire structure tom, the areas included in the warranty are: (specify)
Total Square Feet to be Treated: 3171 Total Linear Feet to be Treated:
Approximate Mneats of the Structure(s) to be Treated:
/1V .ifs Russell C. Breland 02/25/2008
Signature of Certified Applicator or Printed Name
Date
Technician Completing Estimate
A-1 Termites TPCL 11932
Nam of Pest Control Company TPCL. No.
Licensed and regulated under the Texas SUmeterel Pest Control Act
Texas Stractaral Pest Control Bird, PO Box 1927, Aeatin, Texas 78767-IM Telephone number (512) 3054250.
Page 1 of 4
06/04/2008 16:56 9798231606 ELEGANT #0862 P.004 /006
Aml. Termites
979-589-1203 Ot .979-589-3655 Fax
7343 Wixoa Road. P.O. Box SM I. Bryan, TX 77805
TPC1. 1.1932
LIFETIME SUBTERRANEAN TERMITE CONTRACT
Contractor Name:
Contractor Address:
Property Description:
Effective:
Treatment Cost
Treatment Areas:
Transfer Cost:
Degaut Living Homes Prey Nme: Property Owner
P.O. Boa 7%3 Property Address: 1215 Ebbd& Cove
Bryan, TX 7705 CdkV St on, TX 77W
Residence - Horizontal Pormdstion Partial Pretreatment for Subterranean Termites
ilT►JrZirILtT:3
through 02/25/2010
S443.94 Yearly Renewal: $200.00 + tax;-- $215.50
[Xj Plumbing Areas M Exterior Beam M Horbeetai Foundation
$150.00 (Charged to Buyer after sale of Property)
A-1 Termites will annually extead this contract to the Owner for the I,HTR*1E of the property provided the yearly renewal is paid
before the end of the previous cauract period. if active Wmite a*station is found while under contract, A-1 Termites
will retreat the infested am at no charge. If tiro property sells, the new Owner must pay the transfer cost and yearly renewal or the
contract is void A-1 Termites reserves the right to revise the annual m0wal charge after the first year and each year after that. A- l
Termites does NOT guarantec against any present or ft= damage to tbis'property or its contents, nor will A-1 Termites provide for
any repairs that may be necessary. Any additions or alterations to the property drawn on the graph dated 02/25/2008 will allow A- I
Termites the right to change the amount of the amtrai renewal, A 1 Termites.mtsst be notified, of these changes, and the additions or
alterations must be properly treated by A-1 Termites at the,eqxvise of the Owaer, or this contract is invalid.
Elegant Living Homes Date Rxssefl C. Breland C.A. for A-1 Termites
[,iced and Regal ed by the Steal Pqt CQMol Board
P.O. Box 1927, AustK TX 78767-1927 512-305.3250
Page 3 of 4
06/04/2008 16:56 9798231606
ELEGANT
#0862 P.065 /006
�7
M. CONTACTING THE
STRUCTURAL PEST
CONTROL BOARD
The Texas Structural Pest
Control Board does not regulate
pricing of treatments. However,
we are interested in situations
where the price is only a
fraction of the cost of materials
needed to do the job correctly.
Remember, comparing the bid
price to the size of the stmcture
and the cost of terrniticide does
not include costs such as
insurance, travel, labor and
other costs associated with
overhead. FUMIMM, A
CONTRACTOR MAY HAVE
CIVIL OR CRIIAICNAL
LL431 TTY IF THEY
CONSPIRE TO VIOLATE
STRUCTURAL PEST
CONTROL BOARD
REGULATIONS.
Termiticide labels have specific
directions about the product's
use. Pest Control Companies
must follow these directions and
Structural Pest Control Board
regulations including
599.3 (a) and (b):
(a) All pesticide applications
must be made by using the
application rate and methods
and by following the
precautionary statements on the
labeling of the pesticide being
used -
Treatments using kss than label
bighcrvotumezpQlic is are
prohibited for praconstruction
treatments,
(b) for a full treatment the entire
structure shall be treated to
provide a continuous horizontal
and vertical barrier as described
on the pesticide label including
the posting of a treatment sticker
and the final treatment to be
performed within 30 days of
notification of completion of
landscaping or one year from
the date of completion of
cons on; whichever tames
first. Except, wbM construction
has proceeded to the point that
all arms eaenot be nested
before the company providing
the treatment is called to
perform the job, a pwtial
art will be pamittsd if the
owner of the structure or the
person in ctrarge of the
coa%ruchon and the calmed
applicator for the pest control
company sip a statement
attesting to the conditions, and
a4Nh ix to the contract with au
amended t
exact areas treated.
Termiticides must be used at the
prescribed rate, to protect the
structure from teamites and to
comply with state regulations.
The Texas Strucaural pest
Control Board will inspect
specific treaftnents in response
to consumer complaints or
inforrnatiotu that indicates a
possible impmM treatmenL
THE PEST CONTROL
COIVIIPANY IS.REQ>UWXD
TO YPT O M THE TEXAS
STRUCTURAL PEST
CONTROL BOARD 4-24
EMM TV" To
PERFQMMPFG TM
TREAT FI. The prior
treatment notification
requitement is specific to
commercial preconstruction and
dweIliags. The Boat} w4ai0
inspect treatments during
compliance inspesuons of pest
control company opera0ons and
will randomly make inspections
of job sites where u+eanams are
in progress. Such on -site
inspoctio typically kvolve
collecting samples, of the tank
mix and soil samples of
treatment sites following
application. Questions about
termite tt+eatmeat prooa&uw
should be directed to the Texas
Strucnual Pest Control Board
office.
IV. TREATIi TNT
REQUIREMENTS
For existing or post construction
treatments, a variety of
treatments may be used that
include chemical, approved
Texas Structural Pest Control
physical barriers, methods and
devices, and baiting systems.
The Texas Structural Pest
Control Board will ink some
treatments in progress to ensure
that proper procedures Sdt beirig
used. Keep in mind that an
inspection by the Texas
Structural Pest Control Board is
not required for the treatment or
construction to proceed.
Inspections at pretreatment sites,
both residential and commercial,
will be made on a case -by -case
basis.
It is the philosophy of this
agency to combine firm but fair
enforcement actions with an
educational approach to obtain
regulatory compliance.
W . ru -s
A.
Full
0
B.
Partial
(X]
C.
wood
[
D.
Bait
[ )
E.
Commercial
0
F.
Single Family
[X]
I have received a copy of the
Guide for Builders and
Commercial Customers.
Signature of Customer or
ContrWor
T ;•0. t .
oI/08/Ar Page 2 of 2
BUILDING T ERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX�7784Q PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00000400 Date 2/13/08
Application pin number . . . 299200
Property Address . . . . . . 1215 EBBTIDE CV
Property ID: 579020-0204-0040
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . SOUTH HAMPTON PH 2
Property Use . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL DISTRICT
Application valuation . . . . 178000
Owner
------------------------
Contractor
------------------------
ELEGANT LIVING HOMES, INC
P.O. BOX 7063
BRYAN TX 77805
(979) 823-0638
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID DUE
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF.GARAGE (ATT/DET) ATT
HEATED AREA 2462.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 447.00
--------------------------------------
Permit . . . . . .
-------------------------------------
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
551671
Permit Fee . . . .
694.00 Plan Check Fee .00
Issue Date . . . .
2/13/08 Valuation . . . . 178000
Expiration Date . .
8/11/08
Qty Unit Charge
Per Extension
BASE FEE 460.00
78.00 3.0000
THOU BLDG, VAL 100001-500000 234.00
----------------------------------------------------------------------------
Special Notes and Comments
-Make sure to stay at
least 10' off 40, Buffer with House.
-Narrow Wall Bracing
to be Fully Sheat ed with 27" Minimum
BUILDING DEPT REPRESENTATIVE:
. Ak;;X�
APPLICANT:
r
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX,7784,0
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00000400 Date 2/13/08
Application pin number . . . 299200
----------------------------------------------------------------------------
Special Notes and Comments
Regular Garage Framing.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP'PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BUILDING ]
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX,7784.0
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00000400-- Date 2/13/08
Application pin number . . . 299200
----------------------------------------------------------------------------
Special Notes and Comments
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 150-a the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO.ALLOW FOR COVER-UP
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternat ve, R-6 duct
-----------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
1
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX,778AO
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00000400 Date 2/13/08
Application pin number . . . 299200
----------------------------------------------------------------------------
Special Notes and Comments
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . SEWER TAP 4" 350.00
------------------------------------------- '�'L------ --- A-- J- -------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: -�/
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX,77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application
Number . . . .
08-00000400
Date 2/13/08
Application
----------------------------------------------------------------------------
pin number . . .
299200
Other Fees
----------------------------------------------------------------------------
. . . . . . . . .
WATER TAP 3/4"
400.00
Fee summary
-----------------
Charged
Paid..
Credited
Due
Permit Fee
----------
Total 694.00
----------
694.00
----------
.00
----------
.00
Plan Check
Total .00
.00
.00
.00
Other Fee Total
750.00
750:00
.00
.00
Grand Total
1444.00
1444.00
.00
.00
-------------------
BUILDING DE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 08-00000401 Date 2/13/08
Application pin number . . . 399948
Property Address . . . . . . 1215 EBBTIDE CV
Property ID: 579020-0204-0040
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . SOUTH HAMPTON PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL DISTRICT
Application valuation . . . . 0
Owner
------------------------
Contractor
------------------------
ELEGANT LIVING HOMES,
INC .
P.O. BOX 7063
BRYAN
TX 77805
(979) 823-0638
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 551689
Permit Fee . . .
. 20.00
Issue Date . . .
----------------------------------------------------------------------------
. 2/13/08
Valuation . . . .
0
Other Fees . . .
----------------------------------------------------------------------------
. . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary
-----------------
Charged
----------
Paid Credited
Due
Permit Fee Total
20.00
------------------------------
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
--------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT :
----- .J--�--'- s- ------
-� APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGESTATION, TX 77840
CL"1`Y OF COLLLGE STArrON (979) 764-3670 (979) 764-3496 FAX
lyadniix6-D44oprreewSrohn WWWCSTX.GOV
pA .. TRCC REG
APPLICATION #
TEMP POLE # `
ADDRESS/LOCATIO/► -t, S ej0b+1 C(>✓ C 0V f . Coi I e�4 b4r., cv, , TX % % s- 5
LOT 4" BLOCK ` SUBDIVISION 60 U4) P'�LYO �'n � SEC/PH Z Q
BUSINESS/OWNER NAME: �14-Elewr& Lly to PcyrPS PHONE: "l / - '0 61 13o
CONTRACTOR/ HOMEOWNER: M c
CONTACT PERSON FOR REVIEW COMMENTS: 2 i j � `� ms PHONE: ���'ZZC% I � O �J
EMAIL: i ! ivn L ele-C tyLh vi rl t6.L@Yh
PLUMBER: i' 4 '`
&-m e/
FAX: C1 l"t b �3
ELECTRICIAN: 1 hOmC e'
HVAC: M D O r-e S A- I C'
PHONE:
GOOD CENTS (Residential only):
ACCESSORY/STORAGE VING RE -ROOF
ADDITION EW CONSTRUCTION* SHELL ONLY
DEMOLITION (ASBESTOS SURVEY PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED PORTABLE STORAGE (NON-RESIDENTIAL SWIMMING POOL
LOCATION REMODEL/RENOVATION* TENTS
DESCRIPTION OF WORK:
���- -rt,�c-ice c�Y� o-F inew 51 ryA 1 e., (�,m t 1 U /5 k nol j e s
PROPOSED USE: 'C Ider6oL_1
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: -1 C %J
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ FD p TOTAL AREA: I - I HEATED AREA:
(Cost of Labor and Materials)
�UBLIC SEWER
SEPTIC(TREATMENT SYSTEM
EWER TAP:
WATER TAP:
OTHER TAP:
�J TEMP POLE
a`IUD
1 GARAGE TYPE:
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
`I
INTERIOR WALL TYPE:
$IZE r/
EXTERIOR WALL TYPE:
SIZE
FOUNDATION TYPE:
SIZE
ROOF TYPE:
SINGLE
F__j DOUBLE [J TRIPLF
ATTACHED
DETACHED D ,CARPORt
SIGNATURE OF APPLICANT:
*If proposed work involves new commer ' I construe Ion or facade irripr nov
commercial property, building elevat re required.
............................................................
r/P Plans Examiner
--Tokc l'i ACr"V
S
�(o a male
Official Use Only
Zoning Official
PAU
to an existing
ents.
r r NO
w
Energy Code Compliance Information
a �
% Glazing of exterior walls / O �v
Insulation R value of exterior walls / 3
Insulation R value of ceiling 1 (flat areas) 30
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient) 1 3 2—
Glazing U-Factor
R value of ductwork
A/C SEER Rating 3
Protection Against Subterranean Termites
eChemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
'PLAN' REVIEW
(*f/q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning dDevelopment Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# O _ oo
DATE: —0 8
BUILDING ADDRESS: l'5 V�
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
kWOK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/ K
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
@VOK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
OK
/OK
PLAN REVIEW .
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning d'Development Snvica COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
NKVO
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N O
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
(*tl ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducin valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
NA/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
K
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
/ K
"APPROVED PLANS PER IRC SECTION R106.3.1."
LANS EXAMINER DATE
11
I
I I
I I
I 1
I 1215 Ebbtide Cove 1•
1 Lot 4, Block 4, Phase 2
1 South Hampton Subdivision
Elegant Living Homes r
o ' 1
I 1
1 2s rea. setbadk I { �� m L
---------------------------------------- ---
I
I I
I I
1 I
--- 40' after — — — — — — — —— 9--————————————————
ti---
1 I
— — I No clearing in this 49 buffer zone I
I 1 Meese A,%s iv te",.:,j 10 , �/l,cvk� i&) UQ4L
I ,
q I
aD ,
I ,
I 1
I
' � ram•
I
� I �
1 I
I
I
6'-0. I
I FD
' 1
I
I I
Building Outline '
1
' Scale: 1•=20'
1 -10 1 i2
1
I �
1 i
I
I I
1 I
I
I �
1 i
I 11
YIY
N Y
N m
_ m m
g C
— — — Front setback
Driveway
I
15
I
1
1
I
o�2' I
I
72.77
0
CREScheck Software Version 4.0.1
NJ( Compliance Certificate
Project Title: 1215 Ebbtide Cove
Report Date: 02/07/08
Data filename: C:\Program Files\Check\REScheck\1215 Ebbtide Cove.rck
Energy Code: 2000 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 10%
Heating Degree Days: 1788
Construction Site:
1215 Ebbtide Cove
College Station, TX 77845
Owner/Agent:
Bill Morris
ELH-Elegant Living Homes, Inc.
P. 0. Box 7063
Bryan, TX 77805
979-823-0638
cam@elegantliving-bcs.com
Designer/Contractor:
Bill Morris
ELH-Elegant Living Homes, Inc.
P. O. Box 7063
Bryan, TX 77805
979-823-0638
billm@elegantliving-bcs.com
Compliance: Passes Maximum UA: 577 Your Home UA: 398 —> 31.0% Better Than Code (UA)
Maximum SHGC: i 0.34
Ceiling 1: Flat Ceiling or Scissor Truss:
Z4bZ u.v
JV.V
Wall 1: Wood Frame, 16" o.c.:
2341 13.0
0.0
169
Window: 3076 Low E: Metal Frame with Thermal Break, Double
22
0.540
12
Pane with Low-E:
SHGC: 0.32
Window: 1068 Low E: Metal Frame with Thermal Break, Double
13
0.540
7
Pane with Low-E:
SHGC: 0.32
Window: 5020 Low E: Metal Frame with Thermal Break, Double
10
0.540
5
Pane with Low-E:
SHGC: 0.32
Window: 3016 Low E: Metal Frame with Thermal Break, Double
9
0.540
5
Pane with Low-E:
SHGC: 0.32
16
0.540
9
Window: 4040 Glass Block: Other:
SHGC: 0.58
Window: 3060 Low E: Metal Frame with Thermal Break, Double
72
0.540
39
Pane with Low-E:
SHGC: 0.32
Window: 5070 Low E: Metal Frame with Thermal Break, Double
35
0.540
19
Pane with Low-E:
SHGC: 0.32
Window: 3080 Low E: Metal Frame with Thermal Break, Double
48
0.540
26
Pane with Low-E:
SHGC: 0.32
20
0.580
12
3068 Solid Door: Solid:
0.580
10
2868 Solid Door: Solid:
1
9
Door: 2868 Glass w/mini: Glass:
16
0.580
SHGC: 0.30
Air Conditioner 1: Electric Central Air: 13 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications,
and other
calculations submitted with the permit application. The proposed
building has been designed to
meet the 2000 IECC requirements
in
REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Page 1 of 5
1215 Ebbtide Cove
M� Po? /d�
Made - Title Sig to Date
Project Notes:
Please call when permit is ready to pick up:
Bill 979-229-2045
Cindy 979-777-0703
Office 979-823-0638
Thank.you!!
1215 Ebbtide Cove rage z oT 0
CREScheck Software Version 4.0.1
NJ( Inspection Checklist
Date: 02/07/08
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ Window: 3076 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 3076 Low E Window
❑ Window: 1068 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 1068 Low E Sidelight
❑ Window: 5020 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes — No
Comments: 5020 Low E Transom
❑ Window: 3016 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 3016 Low E Transom
❑ Window: 4040 Glass Block: Other, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 4040 Glass Block
❑ Window: 3060 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 3060 Low E Window
❑ Window: 5070 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 5070 Low E Dbl Window
❑ Window: 3080 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 3080 Low E Window
1215 Ebbfide Cove Page 3 of 5
Doors:
❑ 3068 Solid Door: Solid, U-factor: 0.580
Comments: 3068 Solid Door
❑ 2868 Solid Door: Solid, U-factor: 0.580
Comments: 2868 Solid Door
❑ Door: 2868 Glass w/mini: Glass, U-factor: 0.580
Comments: 2868 Glass Door w/miniblind
Heating and Cooling Equipment:
❑ Air Conditioner 1: Electric Central Air: 13 SEER or higher
Make and Model Number:
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in
accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-value without compressing the insulation.
Duct Insulation:
❑ Ducts in unconditioned spaces are insulated to R-5. Ducts outside the building are insulated to R-8.0.
Duct Construction:
❑ All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric,
or tapes. Tapes and mastics are rated UL 181A or UL 181 B.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
❑ The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
❑
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
1215 Ebbtide Cove Page 4 of 5
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Up to 1"
Up to 1.25"
1.5" to 2.0" Over 2"
Temperature (°F)
170-180
0.5
1.0
1.5 2.0
140-169
0.5
0.5
1.0 1.5
100-139
0.5
0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Piping System Types
Fluid Temp.
Range ff )
2^ Runouts 1" and Less
1.25' to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
1.5
2.0
Steam Condensate (for feed water)
Any
1.0
1.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
1215 Ebbtide Cove rage o or o