HomeMy WebLinkAboutRES2008-00400, 08-401a,, 4 W-, "Aid jMqp). OA# �leg�t PREPARED 6/03/08, 11:59:52 INSPECTION TICKET PAGE 9 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/03/08 ------------------------------------------------------------------------------------------------ ADDRESS 1215 EBBTIDE CV SUBDIV: SOUTH HAMPTON PH 2 CONTRACTOR ELEGANT LIVING HOMES, INC PHONE (979) 823-0638 OWNER . . PHONE PARCEL . . 579020-0204-0040 APPL NUMBER: 08-00000400 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 2/28/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00 2/28/08 CA February 27, 2008 2:47:02 PM acarter. B100 02 3/03/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00 3/03/08 AP March 3, 20.08 8:13:20 AM kwolfe. 03/03/2008 05:06 PM RH PDA Strings up, slab ground installed. B115 01 3/26/08 RH BLDG, FRAMING TIME: 17:00 3/26/08 AP March 26, 2008 11:26:48 AM glsouth. '! March 26, 2008 4:52:10 PM kwolfe. B130 01 3/27/08 RH BLDG, INSULATION TIME: 17:00 3/27/08 AP March 27, 2008 8:45:21 AM glsouth. March 27, 2008 3:56:25 PM kwolfe. B125 01 6/03/08 BI BLDG, FINAL TIME: 17:00 lao June 3, 2008 9:30:13 AM ccourt. ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- 66 #0526 P.002 /002 02/27/2008 10:07 9798231606 ELEGANT Feb 22 DS 10s3sa Paul Williams Land Surwou 9797797672 7M NOrY ucket On% Soalee ! ` a ,3p' 6/b' bevy JV 40-o9'7S' E B7ag. (cav #w �/�' Rod t%� AW Me.. IV �49'13' £ 87.e9' iAcknv/i f0' p, ,yr - - - - - - - - - - - - - - - ------------ - - - - - - - - Got 4 �.. s4s• i � i f f cot s o /�dI7i7S ssa• LZ.—L �'� fa`•'. 6 1/779Abd Rkt 5� �d SO h=JLiQr7r7• fig- 8�:MT- w7A LADIf 3 ~ 1 t 7/2 6bn �W Farm Survey 1215 Ebbtide Cove Prepared for.• Elegon t Living Homes, Inc. Suing a// of Lot 4 (FOUR), OApc.* 4 (FWP) .So4fl N HWPrCW SU6D/1//S/OA/, Pi/RSE 2, an odd/tion to the GYy of Cp//9ge Station ercww County Texa:51, q=Ord;ng to the p/ot .ceded �n Yo/unre �1 Page f 19 of the Off;a;a/ Records of grozos County, to pond 71�%//lams. Reg�ietarad Pro7tes ens/ Lone Survayer Aim 574,3 do hejw6y cer6Yy that lids plot nspresenLs bhe results of a svrvqy perlorrrted an trhe ground, under nw Sw0rVzMOn on f'ebruory 15y 2dOB, And !s hus orW cwrnrt to the best of my OW to / further csrtlfy that no ;mprawsrnents an th;.s Pr*Per(Y ft=MOCh CM odjoc&nt praper{j, nar dp mry �inproremeoats on odprent prgperty cwcSroocah on to this Property, a xcePt os Shawn. LAND f SURME)oI NG Co. 30077 �S�w� MOM SUVet. Ste. 206 9F79- 7�w ox 2 Abftr awernafar, b busx! on . m. rO M 4W to pkf caft 1* ewl opyl . 7%s aonp� WOW pf"Pdr0d 44% M& bMrAMW orjpgWpfMW n � =Ii*VM t n� o.F AMAP m� WFl004385 / 001 City of Collegq.--S_tation PAGE 1 REQ. DATE: 02/13/08 02/13/08 13:51:06 LOCATION: 1215 EBBTIDE CV LOC ID: 209068 REQUESTOR: ELEGANT LIVING HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/13/08 SCHED COMPLETION: 02/13/08 ******************************************************************************** JOB ORDER RESULT COMMEgTS 06/04/2008 16:55 9798231606 ELEGANT A Termites P.O. Box 5481, Bryam, TX 7785-5481 979-589-1203 Oft 979-589-3655 Fax A 1 Tem ite *tconl ine . net Treatment Date: 2/25/2008 Treatment Time: 10:00-11:00 Guarantee: 2 Years Renewal bate: 2/25/2010 Renewal Price: $215.50 Property Name & Address Property Owner 1215 Ebbtide Cove College Station, TX 77845 #0862 P.002./006 Invoice No.: 2008-2014 Payment Terms: Due Now Tank Size: 325 Job/Project No: EPA Reg, No: 81824-5 Billing Name & Address Elegant Living Homes P.O. Box 7063 Bryan, TX 77805 Description of Preeonstruetion Treatment Gallons Tarries Chemical A Percentage Slab Area Amount pup, Residential House Slab - Horizontal 317 0.98 AAaxKrhor SC @ 0.06% 3,171 443.94 Foundation Partial Pretreatment for Subterranean Termites Total We $443.94 Receipt of Service Signature A-1 Termites wants to thank you for your business. We now offer Bora-Care Wood Pretreatments in place of the foundation pretreatment. if you would Pike more information please contact our office at 979-589-1203. Please Pay From This INVOICE 06/04/2008 16:55 9798231606 W ELEGANT #0862 P.003 /006 SUBTERRANEAN TERMITE PRECONSTRUCTION DISCLOSURE FOR EACH ESTIMATE For all treatments there will be a diagram showing sty what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at than time for minimum treatment standards. Remember that your architects or design engineers specifications must also b, followed, unless they are in violation of the law. Review the consumer information sheet for further information. If you have any questions, contact the pest control company or the Texas Structural Pest Control Board, P.O. Box 1927, Austin, TX 78767-1927. Telephone number is (512) 305-8250. Contractor Name. Ekgant Living Homes Location Name: Property Owner Contractor Address: P.Q. Boa 7063 Location to Treat: 1215 Ebbtide Cove Bryce TX 7705 College Station, TX 77845 Type of Treatment [ J Full [XI Partial [ ] Wood [ ] Bait [ ] Cormnercial [X] Single Family A label of Mayor SC Tertrtiti Ci*5) is enclosed_ The percentage of the termiticide(s) to be applied at this location is: 0.06% Warranty Information provided mi#w ird&& A6e GompjM ,Dete&S of any WarrQn y provided and the following: Tbue Period of iWarrasuy; Renewd Opdons and Cost; and Obligations of the Conow ng Parties. If the warranty does not include the entire structure tom, the areas included in the warranty are: (specify) Total Square Feet to be Treated: 3171 Total Linear Feet to be Treated: Approximate Mneats of the Structure(s) to be Treated: /1V .ifs Russell C. Breland 02/25/2008 Signature of Certified Applicator or Printed Name Date Technician Completing Estimate A-1 Termites TPCL 11932 Nam of Pest Control Company TPCL. No. Licensed and regulated under the Texas SUmeterel Pest Control Act Texas Stractaral Pest Control Bird, PO Box 1927, Aeatin, Texas 78767-IM Telephone number (512) 3054250. Page 1 of 4 06/04/2008 16:56 9798231606 ELEGANT #0862 P.004 /006 Aml. Termites 979-589-1203 Ot .979-589-3655 Fax 7343 Wixoa Road. P.O. Box SM I. Bryan, TX 77805 TPC1. 1.1932 LIFETIME SUBTERRANEAN TERMITE CONTRACT Contractor Name: Contractor Address: Property Description: Effective: Treatment Cost Treatment Areas: Transfer Cost: Degaut Living Homes Prey Nme: Property Owner P.O. Boa 7%3 Property Address: 1215 Ebbd& Cove Bryan, TX 7705 CdkV St on, TX 77W Residence - Horizontal Pormdstion Partial Pretreatment for Subterranean Termites ilT►JrZirILtT:3 through 02/25/2010 S443.94 Yearly Renewal: $200.00 + tax;-- $215.50 [Xj Plumbing Areas M Exterior Beam M Horbeetai Foundation $150.00 (Charged to Buyer after sale of Property) A-1 Termites will annually extead this contract to the Owner for the I,HTR*1E of the property provided the yearly renewal is paid before the end of the previous cauract period. if active Wmite a*station is found while under contract, A-1 Termites will retreat the infested am at no charge. If tiro property sells, the new Owner must pay the transfer cost and yearly renewal or the contract is void A-1 Termites reserves the right to revise the annual m0wal charge after the first year and each year after that. A- l Termites does NOT guarantec against any present or ft= damage to tbis'property or its contents, nor will A-1 Termites provide for any repairs that may be necessary. Any additions or alterations to the property drawn on the graph dated 02/25/2008 will allow A- I Termites the right to change the amount of the amtrai renewal, A 1 Termites.mtsst be notified, of these changes, and the additions or alterations must be properly treated by A-1 Termites at the,eqxvise of the Owaer, or this contract is invalid. Elegant Living Homes Date Rxssefl C. Breland C.A. for A-1 Termites [,iced and Regal ed by the Steal Pqt CQMol Board P.O. Box 1927, AustK TX 78767-1927 512-305.3250 Page 3 of 4 06/04/2008 16:56 9798231606 ELEGANT #0862 P.065 /006 �7 M. CONTACTING THE STRUCTURAL PEST CONTROL BOARD The Texas Structural Pest Control Board does not regulate pricing of treatments. However, we are interested in situations where the price is only a fraction of the cost of materials needed to do the job correctly. Remember, comparing the bid price to the size of the stmcture and the cost of terrniticide does not include costs such as insurance, travel, labor and other costs associated with overhead. FUMIMM, A CONTRACTOR MAY HAVE CIVIL OR CRIIAICNAL LL431 TTY IF THEY CONSPIRE TO VIOLATE STRUCTURAL PEST CONTROL BOARD REGULATIONS. Termiticide labels have specific directions about the product's use. Pest Control Companies must follow these directions and Structural Pest Control Board regulations including 599.3 (a) and (b): (a) All pesticide applications must be made by using the application rate and methods and by following the precautionary statements on the labeling of the pesticide being used - Treatments using kss than label bighcrvotumezpQlic is are prohibited for praconstruction treatments, (b) for a full treatment the entire structure shall be treated to provide a continuous horizontal and vertical barrier as described on the pesticide label including the posting of a treatment sticker and the final treatment to be performed within 30 days of notification of completion of landscaping or one year from the date of completion of cons on; whichever tames first. Except, wbM construction has proceeded to the point that all arms eaenot be nested before the company providing the treatment is called to perform the job, a pwtial art will be pamittsd if the owner of the structure or the person in ctrarge of the coa%ruchon and the calmed applicator for the pest control company sip a statement attesting to the conditions, and a4Nh ix to the contract with au amended t exact areas treated. Termiticides must be used at the prescribed rate, to protect the structure from teamites and to comply with state regulations. The Texas Strucaural pest Control Board will inspect specific treaftnents in response to consumer complaints or inforrnatiotu that indicates a possible impmM treatmenL THE PEST CONTROL COIVIIPANY IS.REQ>UWXD TO YPT O M THE TEXAS STRUCTURAL PEST CONTROL BOARD 4-24 EMM TV" To PERFQMMPFG TM TREAT FI. The prior treatment notification requitement is specific to commercial preconstruction and dweIliags. The Boat} w4ai0 inspect treatments during compliance inspesuons of pest control company opera0ons and will randomly make inspections of job sites where u+eanams are in progress. Such on -site inspoctio typically kvolve collecting samples, of the tank mix and soil samples of treatment sites following application. Questions about termite tt+eatmeat prooa&uw should be directed to the Texas Strucnual Pest Control Board office. IV. TREATIi TNT REQUIREMENTS For existing or post construction treatments, a variety of treatments may be used that include chemical, approved Texas Structural Pest Control physical barriers, methods and devices, and baiting systems. The Texas Structural Pest Control Board will ink some treatments in progress to ensure that proper procedures Sdt beirig used. Keep in mind that an inspection by the Texas Structural Pest Control Board is not required for the treatment or construction to proceed. Inspections at pretreatment sites, both residential and commercial, will be made on a case -by -case basis. It is the philosophy of this agency to combine firm but fair enforcement actions with an educational approach to obtain regulatory compliance. W . ru -s A. Full 0 B. Partial (X] C. wood [ D. Bait [ ) E. Commercial 0 F. Single Family [X] I have received a copy of the Guide for Builders and Commercial Customers. Signature of Customer or ContrWor T ;•0. t . oI/08/Ar Page 2 of 2 BUILDING T ERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX�7784Q PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00000400 Date 2/13/08 Application pin number . . . 299200 Property Address . . . . . . 1215 EBBTIDE CV Property ID: 579020-0204-0040 R #• Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SOUTH HAMPTON PH 2 Property Use . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 178000 Owner ------------------------ Contractor ------------------------ ELEGANT LIVING HOMES, INC P.O. BOX 7063 BRYAN TX 77805 (979) 823-0638 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID DUE FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF.GARAGE (ATT/DET) ATT HEATED AREA 2462.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 447.00 -------------------------------------- Permit . . . . . . ------------------------------------- BUILDING PERMIT Additional desc . . AC Permit pin number . 551671 Permit Fee . . . . 694.00 Plan Check Fee .00 Issue Date . . . . 2/13/08 Valuation . . . . 178000 Expiration Date . . 8/11/08 Qty Unit Charge Per Extension BASE FEE 460.00 78.00 3.0000 THOU BLDG, VAL 100001-500000 234.00 ---------------------------------------------------------------------------- Special Notes and Comments -Make sure to stay at least 10' off 40, Buffer with House. -Narrow Wall Bracing to be Fully Sheat ed with 27" Minimum BUILDING DEPT REPRESENTATIVE: . Ak;;X� APPLICANT: r BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX,7784,0 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00000400 Date 2/13/08 Application pin number . . . 299200 ---------------------------------------------------------------------------- Special Notes and Comments Regular Garage Framing. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) *PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP'PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BUILDING ] APPLICANT BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX,7784.0 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00000400-- Date 2/13/08 Application pin number . . . 299200 ---------------------------------------------------------------------------- Special Notes and Comments BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 150-a the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO.ALLOW FOR COVER-UP *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternat ve, R-6 duct ----------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: 1 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX,778AO PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00000400 Date 2/13/08 Application pin number . . . 299200 ---------------------------------------------------------------------------- Special Notes and Comments insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . SEWER TAP 4" 350.00 ------------------------------------------- '�'L------ --- A-- J- ------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: -�/ BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX,77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . 08-00000400 Date 2/13/08 Application ---------------------------------------------------------------------------- pin number . . . 299200 Other Fees ---------------------------------------------------------------------------- . . . . . . . . . WATER TAP 3/4" 400.00 Fee summary ----------------- Charged Paid.. Credited Due Permit Fee ---------- Total 694.00 ---------- 694.00 ---------- .00 ---------- .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750:00 .00 .00 Grand Total 1444.00 1444.00 .00 .00 ------------------- BUILDING DE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00000401 Date 2/13/08 Application pin number . . . 399948 Property Address . . . . . . 1215 EBBTIDE CV Property ID: 579020-0204-0040 R #. Application type description TEMP POLE Subdivision Name . . . . . . SOUTH HAMPTON PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 0 Owner ------------------------ Contractor ------------------------ ELEGANT LIVING HOMES, INC . P.O. BOX 7063 BRYAN TX 77805 (979) 823-0638 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 551689 Permit Fee . . . . 20.00 Issue Date . . . ---------------------------------------------------------------------------- . 2/13/08 Valuation . . . . 0 Other Fees . . . ---------------------------------------------------------------------------- . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Charged ---------- Paid Credited Due Permit Fee Total 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 -------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT : ----- .J--�--'- s- ------ -� APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGESTATION, TX 77840 CL"1`Y OF COLLLGE STArrON (979) 764-3670 (979) 764-3496 FAX lyadniix6-D44oprreewSrohn WWWCSTX.GOV pA .. TRCC REG APPLICATION # TEMP POLE # ` ADDRESS/LOCATIO/► -t, S ej0b+1 C(>✓ C 0V f . Coi I e�4 b4r., cv, , TX % % s- 5 LOT 4" BLOCK ` SUBDIVISION 60 U4) P'�LYO �'n � SEC/PH Z Q BUSINESS/OWNER NAME: �14-Elewr& Lly to PcyrPS PHONE: "l / - '0 61 13o CONTRACTOR/ HOMEOWNER: M c CONTACT PERSON FOR REVIEW COMMENTS: 2 i j � `� ms PHONE: ���'ZZC% I � O �J EMAIL: i ! ivn L ele-C tyLh vi rl t6.L@Yh PLUMBER: i' 4 '` &-m e/ FAX: C1 l"t b �3 ELECTRICIAN: 1 hOmC e' HVAC: M D O r-e S A- I C' PHONE: GOOD CENTS (Residential only): ACCESSORY/STORAGE VING RE -ROOF ADDITION EW CONSTRUCTION* SHELL ONLY DEMOLITION (ASBESTOS SURVEY PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED PORTABLE STORAGE (NON-RESIDENTIAL SWIMMING POOL LOCATION REMODEL/RENOVATION* TENTS DESCRIPTION OF WORK: ���- -rt,�c-ice c�Y� o-F inew 51 ryA 1 e., (�,m t 1 U /5 k nol j e s PROPOSED USE: 'C Ider6oL_1 STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: -1 C %J TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ FD p TOTAL AREA: I - I HEATED AREA: (Cost of Labor and Materials) �UBLIC SEWER SEPTIC(TREATMENT SYSTEM EWER TAP: WATER TAP: OTHER TAP: �J TEMP POLE a`IUD 1 GARAGE TYPE: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: `I INTERIOR WALL TYPE: $IZE r/ EXTERIOR WALL TYPE: SIZE FOUNDATION TYPE: SIZE ROOF TYPE: SINGLE F__j DOUBLE [J TRIPLF ATTACHED DETACHED D ,CARPORt SIGNATURE OF APPLICANT: *If proposed work involves new commer ' I construe Ion or facade irripr nov commercial property, building elevat re required. ............................................................ r/P Plans Examiner --Tokc l'i ACr"V S �(o a male Official Use Only Zoning Official PAU to an existing ents. r r NO w Energy Code Compliance Information a � % Glazing of exterior walls / O �v Insulation R value of exterior walls / 3 Insulation R value of ceiling 1 (flat areas) 30 Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) 1 3 2— Glazing U-Factor R value of ductwork A/C SEER Rating 3 Protection Against Subterranean Termites eChemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. 'PLAN' REVIEW (*f/q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning dDevelopment Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# O _ oo DATE: —0 8 BUILDING ADDRESS: l'5 V� I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated kWOK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ K A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck @VOK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. OK /OK PLAN REVIEW . ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning d'Development Snvica COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details NKVO 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N O 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW (*tl ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducin valve required when water pressure exceeds 80 psi N K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements NA/ A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N K Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed / K "APPROVED PLANS PER IRC SECTION R106.3.1." LANS EXAMINER DATE 11 I I I I I I 1 I 1215 Ebbtide Cove 1• 1 Lot 4, Block 4, Phase 2 1 South Hampton Subdivision Elegant Living Homes r o ' 1 I 1 1 2s rea. setbadk I { �� m L ---------------------------------------- --- I I I I I 1 I --- 40' after — — — — — — — —— 9--———————————————— ti--- 1 I — — I No clearing in this 49 buffer zone I I 1 Meese A,%s iv te",.:,j 10 , �/l,cvk� i&) UQ4L I , q I aD , I , I 1 I ' � ram• I � I � 1 I I I 6'-0. I I FD ' 1 I I I Building Outline ' 1 ' Scale: 1•=20' 1 -10 1 i2 1 I � 1 i I I I 1 I I I � 1 i I 11 YIY N Y N m _ m m g C — — — Front setback Driveway I 15 I 1 1 I o�2' I I 72.77 0 CREScheck Software Version 4.0.1 NJ( Compliance Certificate Project Title: 1215 Ebbtide Cove Report Date: 02/07/08 Data filename: C:\Program Files\Check\REScheck\1215 Ebbtide Cove.rck Energy Code: 2000 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 10% Heating Degree Days: 1788 Construction Site: 1215 Ebbtide Cove College Station, TX 77845 Owner/Agent: Bill Morris ELH-Elegant Living Homes, Inc. P. 0. Box 7063 Bryan, TX 77805 979-823-0638 cam@elegantliving-bcs.com Designer/Contractor: Bill Morris ELH-Elegant Living Homes, Inc. P. O. Box 7063 Bryan, TX 77805 979-823-0638 billm@elegantliving-bcs.com Compliance: Passes Maximum UA: 577 Your Home UA: 398 —> 31.0% Better Than Code (UA) Maximum SHGC: i 0.34 Ceiling 1: Flat Ceiling or Scissor Truss: Z4bZ u.v JV.V Wall 1: Wood Frame, 16" o.c.: 2341 13.0 0.0 169 Window: 3076 Low E: Metal Frame with Thermal Break, Double 22 0.540 12 Pane with Low-E: SHGC: 0.32 Window: 1068 Low E: Metal Frame with Thermal Break, Double 13 0.540 7 Pane with Low-E: SHGC: 0.32 Window: 5020 Low E: Metal Frame with Thermal Break, Double 10 0.540 5 Pane with Low-E: SHGC: 0.32 Window: 3016 Low E: Metal Frame with Thermal Break, Double 9 0.540 5 Pane with Low-E: SHGC: 0.32 16 0.540 9 Window: 4040 Glass Block: Other: SHGC: 0.58 Window: 3060 Low E: Metal Frame with Thermal Break, Double 72 0.540 39 Pane with Low-E: SHGC: 0.32 Window: 5070 Low E: Metal Frame with Thermal Break, Double 35 0.540 19 Pane with Low-E: SHGC: 0.32 Window: 3080 Low E: Metal Frame with Thermal Break, Double 48 0.540 26 Pane with Low-E: SHGC: 0.32 20 0.580 12 3068 Solid Door: Solid: 0.580 10 2868 Solid Door: Solid: 1 9 Door: 2868 Glass w/mini: Glass: 16 0.580 SHGC: 0.30 Air Conditioner 1: Electric Central Air: 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Page 1 of 5 1215 Ebbtide Cove M� Po? /d� Made - Title Sig to Date Project Notes: Please call when permit is ready to pick up: Bill 979-229-2045 Cindy 979-777-0703 Office 979-823-0638 Thank.you!! 1215 Ebbtide Cove rage z oT 0 CREScheck Software Version 4.0.1 NJ( Inspection Checklist Date: 02/07/08 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: ❑ Window: 3076 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: 3076 Low E Window ❑ Window: 1068 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: 1068 Low E Sidelight ❑ Window: 5020 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes — No Comments: 5020 Low E Transom ❑ Window: 3016 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: 3016 Low E Transom ❑ Window: 4040 Glass Block: Other, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: 4040 Glass Block ❑ Window: 3060 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: 3060 Low E Window ❑ Window: 5070 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: 5070 Low E Dbl Window ❑ Window: 3080 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: 3080 Low E Window 1215 Ebbfide Cove Page 3 of 5 Doors: ❑ 3068 Solid Door: Solid, U-factor: 0.580 Comments: 3068 Solid Door ❑ 2868 Solid Door: Solid, U-factor: 0.580 Comments: 2868 Solid Door ❑ Door: 2868 Glass w/mini: Glass, U-factor: 0.580 Comments: 2868 Glass Door w/miniblind Heating and Cooling Equipment: ❑ Air Conditioner 1: Electric Central Air: 13 SEER or higher Make and Model Number: Solar Heat Gain Coefficient: ❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Ducts in unconditioned spaces are insulated to R-5. Ducts outside the building are insulated to R-8.0. Duct Construction: ❑ All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system provides a means for balancing air and water systems. Temperature Controls: ❑ Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Service Water Heating: ❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: ❑ Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable ❑ sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. 1215 Ebbtide Cove Page 4 of 5 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" Temperature (°F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Insulation Thickness in Inches by Pipe Sizes Piping System Types Fluid Temp. Range ff ) 2^ Runouts 1" and Less 1.25' to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 1.5 2.0 Steam Condensate (for feed water) Any 1.0 1.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) 1215 Ebbtide Cove rage o or o