PREPARED 7/14/08, 9:01:38 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/11/08
------------------------------------------------------------------------------------------------
ADDRESS . : 1024 WALTON DR SUBDIV: COLLEGE HILLS
CONTRACTOR BACC ENTERPRISES, INC PHONE (979) 776-2222
OWNER LEIGHTON, WILLIE M TRUSTEE PHONE
PARCEL 194000-0070-0130
APPL NUMBER: 08-00000397 RESIDENTIAL, REMODEL & RENOVATION
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B115 01 3/11/08 OC BLDG, FRAMING TIME: 17:00
3/11/08 AP March 11, 2008 4:36:25 PM kwolfe.
March 11, 2008 4:36:37 PM kwolfe.
B130 01 3/20/08 RH BLDG, INSULATION TIME: 17:00
3/20/08 AP March 20, 2008 8:22:02 AM glsouth.
March 20, 2008 8:22:06 AM glsouth.
B125 01 7/ 1/08 ,�Ir BLDG, FINAL TIME: 17:00
July 11, 2008 2:23:06 PM acarter.
NUMBER 102 4 THEN�ENTER . —
COME IN THROUGH GARAGE DOOR -AND _USE _CODE _ WHICH IS ADDRESS —
-------------------------------------- COMMENTS AND NOTES --------------------------------------
BUILDING PERMIT
CITY CF COIpLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
LEIGHTON, WILLIE M TRUSTEE
ATTN: HUGH LINDSAY 412 TARROW
ST
COLLEGE STATION TX 77840
08-00000397 Date- 2/11/08
532777
1024 WALTON DR
194000-0070-0130
R23670
RESIDENTIAL, REMODEL & RENOVATION
COLLEGE HILLS
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
65000
Contractor
BACC ENTERPRISES, INC
10464 SH 30
COLLEGE STATION TX 77845
(979) 776-2222
--- Structure Information 000 000 REMODEL
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . IMPACT/PRORATA FEES PAID NA
HEATED AREA 2015.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit pin number . 551093
Permit Fee . . . . 320.00 Plan Check Fee .00
Issue Date . . . . 2/11/08 Valuation . . . . 65000
Expiration Date . . 8/09/08
Qty Unit Charge Per Extension
BASE FEE 260.00
15.00 4.0000 THOU BLDG, VAL 50001-100000 60.00
----------------------------------------------------------------------------
Special Notes and Comments
-Remodel of house to include removal of the existing
fireplace and replace with structural exposed beams, rewire
entire house including new service, replace all mechanical,
rearranging bathroom fixtures and removing all existing gas
outlets.
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
-------------------------------- ----- A
BUILDING DEPV REPRESENTATIVE: '_
APPLICANT:
BUILDING PERMIT
CITY OF COImLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00000397 Date 2/11/08
Application pin number . . . 532777
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 150-. the Values Shall be
R-13 and R-30, above 15o the Ceiling Insulation is Increased
to R-38.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20a A .40 OR DOWER FACTOR AND
-------------------------------------------------------------
BUILDING DART REPRESENTATIVE:
APPLICANT: /� Q ��n �_ �("�Q� �C(__,
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00000397 Date 2/11/08
Application pin number . . . 532777
----------------- 7----------------------------------------------------------
Special Notes and Comments
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total
Plan Check Total
Grand Total
320.00 320.00
.00 .00
320.00 320.00
----- W----_4-
BUILDING DEM REPRESENTATIVE:
APPLICANT:
is
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
LEIGHTON, WILLIE M TRUSTEE
ATTN: HUGH LINDSAY 412 TARROW
ST
COLLEGE STATION TX 77840
08-00000404 Date 2/11/08
194564
1024 WALTON DR
194000-0070-0130
TEMP POLE
COLLEGE HILLS
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Contractor
BACC ENTERPRISES, INC
10464 SH 30
COLLEGE STATION TX 77845
(979) 776-2222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit pin number
. 551101
Permit Fee . . .
. 20.00
Issue Date . . .
. 2/11/08
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
----------------------------------------------------------------------------
. . . . . .
TEMP ELECT
POLE CONNECT
45.00
Fee summary
-----------------
Charged
Paid
Credited
Due
Permit Fee Total
----------
20.00
----------
20.00
--------------------
.00
.00
Other Fee Total
45.00
45.00
.00
.00
Grand Total
65.00
65.00
.00
.00
BUILDING DEff REPRESENTATIVE: 1
1 \
MEMBERI01MITZ1�1F.12 l.J�M94
For Ofte UUse Only
APPLICATION FOR BUILDING PERMIT DATE: CC REG '� CITY OF COLLEGE STATION APPLICATION # 00O ~YI 1)
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
TEMP PALE #
Cm of COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning b''l7atdny,nnrt Srviar.
n `WWW.CSTX.GOV
vats- �D SS/eL14ATION: Io24- �1 G�, S� y
LOT 13 I BLOCK �_ SUBDIVISION RA�SEC/PH
BUSINESS/OWNER NAME: _ [y t �� I0f_r priCeS '_ -Ar � PHONE: b2U- KjI D-D-Vtlq 1t G-
CONTRACTOR(HOMEOWNER: RA�� E14mr i Ce.0 a he, PHONE: S 20 - N � 6 92o - 141
CONTACT PERSON
rtjFOR
hREVIEW COMMENTS:RI"Cm+ 1" 1 ckly_' PHONE: b 2-0 Vf t
FAX: EMAILA-f1\&614_.)eVerrun.nPk loma��r�,e�.yer�ze�,n�
ELECTRICIAN: [SE ?) C ec4r 1C i PLUMBER:
HVAC: MAI-ek. GOOD CENTS (Residential only): N�
ACCESSORY/STORAGE MOVING RE -ROOF
�� ^ i` ADDITION NEW CONSTRUCTION* SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
o�/A LOCATION REMODEURENOVAT,I,ON" f TENTS
DESCRIPTION OF WORK: ['t� �(1nAP I. \ n-�er b O,,hL°.tL(a' 0� � 1 OI ^(f1,ome_/
I i
PROPOSED USE: 1'�Sjc�er,�latnVeS�-rr`Pn� �li�� �V I411 I� Itljpz VIP,o-r>
STRUCTURE USE: Nrn)eI �glmp�
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: eS
TEXAS ACCESSIBILITYn /
STANDARD (TAS) PROJECT REGISTRATIO�N# EABPRJ n ,
VALUATION: $ 5 Q CO , TOTAL AREA: -Q IS HEATED AREA: /� IS
(Cost of Labor an Materials)
Vj PUBLIC SEWER NUMBER OF BEDROOMS: 3
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 2—
❑ SEWER TAP:
❑ WATER TAP:
OTHER TAP:
® TEMP POLE
GARAGE TYPE
SIZE
SIZE
SIZE
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
SINGLE a DOUBLE
ATTACHE ® DETACHED
SIGNATURE OF APPLICANT:
*If proposed work involves new com ercial constructio
commercial property, building elevations are required.
Official
Plans Examiner
N
•sw•d �,1
® TRIPLE
CARPORT
P r '��log
or facade
..............................
Xse Only
Zoning Official
to an existing
C ents:
SA NO
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
2' Chemical Termiticide Treatment (Soil Treatment)
Q Chemical Termiticide Treatment (Field Applied Wood Treatment)
Physical Barriers
O Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
PLAN REVIEW
(*f/q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# o
DATE:
BUILDING ADDRESS:
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
0.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
UVOK
/OK
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Strviat COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches ,
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
(*f/q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning &Development Servicei COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
A roved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
A K
"APPROVED PLANS PER IRC SECTION R106.3.1."
j"_ � V
ANS EXAMINER
DATE