Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2008-00372, 08-373
OS op 37Z OS-373Li�NP� 1 PREPARED 5/21/08, 12:14:06 INSPECTION TICKET PAGE 16 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/21/08 ------------------------------------------------------------------------------------------------ ADDRESS 3915 LAMBERMONT DR SUBDIV: EDELWEISS GARTENS 10 CONTRACTOR B A CATHEY PHONE : (979) 255-7064 OWNER . . PHONE PARCEL . . 244030-1018-0110 APPL NUMBER: 08-00000372 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 2/15/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00 2/15/08 AP February 14, 2008 10:51:37 AM acarter. friday afternoon please Strings On Setbacks O.K. Slab Ground Installed B115 01 3/07/08 OC BLDG, FRAMING TIME: 17:00 3/07/08 AP March 6, 2008 1:42:36 PM glsouth. B130 01 3/10/08 BB BLDG, INSULATION TIME: 17:00 3/10/08 AP March 10, 2008 10:35:23 AM acarter. / March 10, 2008 4:28:07 PM kwolfe. \ B125 01 21/08 BI BLDG, FINAL TIME: 17:00 May 21, 2008 10:16:58 AM glsouth. ----------------------------------- CONTINUED ONTO NEXT PAGE -------------------------------- -- Feb 29 08 12:50p MACIAS 9797744736 p.10 TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT PrQpody Owner: CATHEY DEVELOPMENT Location to be Treated: 3915 LAMBERMONT Approximate Measures to be Tread: 2367 Percentage of Termticide(s) to be applied at this lion: 0.06[g 79 GAL. T = of Treatment: Full Part'al XX Vertical xX HorizontailPerimeter Bea m_XX Foundation: SLAB Sidina: BRICK Primory Use: RESIDENCE Roof: COMPOSITION A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USEO HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) INCLUDING AREA COVERED. TWEE PERIOD OF WARRANTY. RENEWAL OPTIONSAND COST. THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE- TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. Charges for pre -treat: NOTES: Annual re-newal: SEE ATTACHED SKETCH BUILDERS SUPPLIES SKETCH/ PLAN $307.47 $126.00 32129 PT 2115/2008 Ca or Techincim SPCB Iicmm 0 32129 PT WFl003229 / 001 City of College,Station PAGE 1 REQ. DATE: 02/08/08 02/08/08 14:18:09 LOCATION: 3915 LAMBERMONT DR LOC ID: 210788 REQUESTOR: B A CATHEY ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/41' SWR 41' ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/08/08 SCHED COMPLETION: 02/08/08 ******************************************************************************** JOB ORDER RESULT CONNE14TS BUILDING PERMIT —IU 4 4-11�16`G' CITY OF COLLEGE' STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00000372 Date 2/08/08 Application pin number . . . 632712 Property Address . . . . . . 3915 LAMBERMONT DR Property ID: 244030-1018-0110 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . EDELWEISS GARTENS 10 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 114378 Owner Contractor ------------------------ ------------------------ B A CATHEY PO BOX 9517 COLLEGE STATION TX 77842 (979) 255-7064 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1733.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 550855 Permit Fee . . . . 505.00 Plan Check Fee .00 Issue Date . . . . 2/08/08 Valuation . . . . 114378 Expiration Date . . 8/06/08 Qty Unit Charge Per Extension BASE FEE 460.00 15.00 3.0000 THOU BLDG, VAL 100001-500000 45.00 ---------------------------------------------------------------------------- Special Notes and Comments -Add Smoke Detector Outside of Master Bedroom -Narrow Wall Bracin Fully Sheath-e-d- -w-i------�Min-imum APA P Av ---------- BUILDING DEP RESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE, STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00000372 Application pin number . . . 632712 Page 2 Date 2/08/08 Special Notes and Comments Garage Framing *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. ------------------------- ------------------ ----- - -- -----'---------- BUILDING DEPT R RE ENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00000372 Date 2/08/08 Application pin number . . . 632712 ---------------------------------------------------------------------------- Special Notes and Comments If Wall to Window Ratio is up to 150-o the Values Shall be R-13 and R-30, above 15o the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING.BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 150W of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ----------------------------- --------------- ----- --- ------------ BUILDING DEPT RE ES NTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE, STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00000372 Date 2/08/08 Application pin number . . . 632712 ---------------------------------------------------------------------------- Special Notes and Comments *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *ADD SMOKE DETECTOR(S) PER NOTES ON PLANS *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) *U-Factor Ratings for Window % up to 15% is .65, from 150W to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK --------------------------- ---------------- ------ --- --- - -.---------- BUILDING DEPT REP ES TATIVE: APPLICANT: BUILDING,PERMIT CITY OF COLLEGE, SSTATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00000372 Date 2/08/08 Application ---------------------------------------------------------------------------- pin number . . . 632712 Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited Due Permit Fee Total 505.00 -------------------- 505.00 .00 ---------- .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1255.00 1255.00 .00 .00 -------------------------- ------------------ --------- - ----_--------------- -A BUILDING DEPT REP ES NTATIVE: // .1 / . APPLICANT: / TEMPORARY POLE PERMIT CITY OF COLLEGE, STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . Application pin number . . Property Address . . . Property ID: R #• Application type description Subdivision Name . . . . . Property Use . . . . . . . Property Zoning . . . . . . Application valuation . . . 08-00000373 Date 715058 3915 LAMBERMONT DR 244030-1018-0110 TEMP POLE EDELWEISS GARTENS 10 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 2/08/08 Owner -----------------------"- Contractor ------------------------ B A CATHEY PO BOX 9517 COLLEGE STATION TX 77842 (979) 255-7064 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 550863 Permit Fee . . . . 20.00 Issue Date . . . . 2/08/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited Due Permit Fee Total 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------------------- -------�-- ---.------------ BUILDING DEPT R P SENTATIVE: APPLICANT: 41 01 SEWER TAP: R WATER TAP: OTHER TAP: ® TEMP POLE GARAGE TYPE: (*//4" CITY OF COLLEGE STATION Planning d Dmlopmenl Semicrt APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77B40 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV lFor o�ffwe Use Only 'n DATE-d_6—y TRCC REG APPLICATION tl �� TEMP POLE # ll l — ✓ ADDRESS/LOCATION: =}' I I � j"� i3 ` �"I't C `' � I C, LOT �• ' BLOCK ✓ SUBDIVISION &L7�� SEC/PHA_ BUSINESS/OWNER NAME: PHONE: iV, L©— 9 7 CONTRACTOR/HOMEOWNER: 4 M PHONE: CONTACT PERSON FOR REVIEW COMMENTS: As Dr7 PHONE: PZd `/0_2z FAX: l �1�" Dd�,F� EMAIL: `I�S��"�1 0C'L ELECTRICIAN: � # �✓ I� CUM fit~ � HVAC: 'zAgz�peS PLUMBER: GOOD CENTS (Residential only): 00 ;lam ACCESSORY/STORAGE F1 MOVING FI RE -ROOF ADDITION NEW CONSTRUCTION* SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEURENOVATION* TENTS DESCRIPTION OF WORK: �I,J I� L� —t-,e�n..I L-+ � Lz' PROPOSED USE: STRUCTURE USE: t( HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILIT� STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ SII! d'78 TOTAL AREA., �f HEATED AREA: j733 T. (Cos of Labor and Materials) N PUBLIC SEWER SEPTIC/TREATMENT SYSTEM ii SIZE Sim SINGLE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: a DOUBLE 0 TRIPLE ATTACHED � (TACHED F-1 CARPORT /%Aso�P—ti sLN �r,J6 L ICI SIGNATURE OF APPLICANT: *If proposed work involves new commerclatt6nstruction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only ments: �� a • 7'0b YE or NO _ F1 P Plans Examiner Zoning Official -- 440 811AU'Ot ` �✓(�`( S .l wt� l b" �tru "A Tkv z zi Ac•c sS "ol SO o ✓� rW e k" Energy Code Compliance Information % Glazing of exterior walls. Insulation R value of exterior walls 13 Insulation R value of ceiling I (flat areas) 30 Insulation R value of ceiling 2 (vaulted areas/no attic) Ig Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor . �S R value of ductwork A/C SEER Rating Protection Against Subterranean Termites 91 Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy, (*f/q" CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# _ ? ? J DATE: BUILDING ADDRESS: _ I. Foundation Requirements- Minimum City Foundation Standards NA/ K A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated K II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an 0. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. A K N /OK CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements NAlto A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: W'? 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location CITY OF COLLEGE STATION Planning cd Development Servicei PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NAJqU B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) 7 B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N K A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. rJ� Zoning Ordinance Requirements — Ordinance 850 Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N O Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N O Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N / Does not block any water course or divert any flow Elevation certificate needed —8OK "APPROVED PLANS PER IRC SECTION R106.3.1." LANS EXAMINER DATE