Loading...
HomeMy WebLinkAboutRES2008-00339, 08-340F PREPARED 7/14/08, 12:09:59 INSPECTION TICKET PAGE 10 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/14/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 4124 MCFARLAND DR SUBDIV: SOUTHERN TRACE PH 2 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 579530-0209-0090 APPL NUMBER: 08-00000339 ------------------------------------------------------------------------------------------------ RESIDENTIAL, 1 UNIT DETACHED NEW PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 3/14/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00 3/14/08 AP March 14, 2008 9:41:16 AM glsouth. 03/14/2008 03:19 PM BB PDA Strings up. Slab ground installed. B120 01 4/01/08 OC BLDG, FRAMING -PARTIAL TIME: 17:00 4/01/08 CA March 31, 2008 2:30:48 PM acarter. apa inspection B145 01 4/01/08 OC BLDG, EXT. SHEATHING FASTENER TIME: 17:00 4/01/08 AP April 1, 2008 11:39:12 AM glsouth. B115 01 4/16/08 BB BLDG, FRAMING TIME: 17:00 4/16/08 DP April 16, 2008 9:27:55 AM acarter. 04/16/2008 04:52 PM BB PDA Nailing pattern on rear wind bracing, needs to be 4 inches O.C. on edges and 12 inches in field. Inner liners on A\C duct, at vents, need to be fixed, as noted on previous inspection. B115 02 4/18/08 RH BLDG, FRAMING TIME: 17:00 a 4/18/08 AE April 17, 2008 4:15:43 PM glsouth. 04/18/2008 11:54 AM RH PDA Re -mount switch box in Bathroom upstairs by insulation. B130 01 4/22/08 RH BLDG, INSULATION TIME: 17:00 4/22/08 AP April 21, 2008 3:31:31 PM glsouth. B132 01 4/24/08 BB BLDG, SHEETROCK FASTENER TIME: 17:00 4/24/08 AP April 24, 2008 10:22:19 AM acarter. April 24, 2008 4:49:55 PM glsouth. B125 01 7/03/08 BI BLDG, FINAL TIME: 17:00 7/03/08 CA July 2, 2008 4:11:39 PM ccourt. B125 02 7/14/08 BI BLDG, FINAL TIME: 17:00 D July 14, 2008 9:17:17 AM acarter. ------------ COMMENTS AND NOTES ----------------------------------- -Ap r 4. 2008" 9:42AM - Stylecraft Builders, Inc. No. 8561 "Shielding & Protecting Homes Against Pests" Renewable S Year Subterranean Termite Retreatment Agreement (Does not cover any other species of Termites) a,?31 This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph). Customer Name Date Billing Name if different y/;�/ // CA,4,VI,ti3 Street Address of treated structure Billing Address if different .s Tx 774fyr city State lip Code City Home Phonc Work Phone 3jpe of Treatment Partial Bait X Pre -Treat Treatment for: ,Prevention Control of Subterranean Termites Notes; State Zip Code Initial Termite Cost S %� Additional Renewals Paid Other Tax Cash_Check# Total $ payment $ '' G Balance $ �r Credit Card. -- Type Exp. Date Card Number S Year Subterraneag JeMita Ratr aatment Guarantee: RP Lcc Termite and Pest Control will.retreat the structure for Subterranean Termites at no cost to the customer, if an irr£estation of Subterranean Termites is found, as long as the original treatment is paid in full and the customer is current on their yearly renewals. This Agreement will expire in one (1) year unless the customer elects to pay the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termitc and Pest Control may approve additional warranty years after the five (5) years with an additional increase in the yearly warranty fcc. The guarantee does not cover any damages to the structure or contents of the customer. The customer agrees to control all conclusive conditions that may cause rcin£cstatiom If the structure is modified, added on to, altered, or if the soil treatment around the structure is removed the customer must contact RP Lee Termite and Pest Control and pay for additional treatment in order to keep the guarantee in c5ect. if the customer does not pay for additional treatment the rctrcatmmt guarantee can be cancelled. po f nemni. w Customer may elect to roncw the retreatment guarantee for addiRiq*years. The renewal fee is $ 5V. Plus tax. The renewal fcc is due on or before the annual aunivmury date or paid $ plus tax every third (3) month with inspection. Maintainigg,the Cuamoke_ The customer agrees to corrcet all conclusive conditions, at owner's expense, as tbey exist or as they occur in the future in order for the guarantee not to be cauccEcd. Customer will make the structure available for inspections and treatments as requested by RP Lcc Termite and Pest Control. $gagggWm RP Lee Termite and Pcst Control will reinspect the structoe at customers rrqucst or any other times RP Lcc Termite and Pcst Control deems necessary. RP Lcc Tcrmite and Pest Control recommends that the customer call and set up an annual inspec- tion at the time of customers yearly renewal. Transfer: This agreement may be transferred to a new owner with the payment of it ttansfer fee of $ copy of the Wood Destroying Insect Report tkom the sell, and approval of RP Lcc Termite and Pest Control. This ,901c neap Termite Retreatment Cbmmntee does not prevent and is not intended to m tml other forms of T rmites (Pnmmd Formosan etc). Wood Boring BffAu&menter Ants, Carpenter Bees- Wood Rat _ agg Decay, or any_oth_er_ wood destrggng insects ar organisms. AM In the event of any dispute arising out o.f this agreement or any outer services performed or not performed the patties above agree to partieipate in mediation through and in accordance with the commercial mediation rules of the American Arbitration Association. Tho Arbitrator shall consider the legal dcfenscs.raised in the arbitration, and the decision of tho arbitrator shall be final, binding, non-appcolablc and maybe entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration Act Limitation of LiabOity: Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled up in certain areas around the home, drill holes may need to be made in floor coverings such as tilt or linoleum or in cabinets next to pipe areas, and holes may need to be cut in walls. Customer agrees not to hold RP Lee Termite and Pcst Control liable for these damages, or trzatmcat techniques, or other damages that may occur during treatment. A This Agreement shall be the entire agreement between customer and RP LceTermite and Pest Control. If any part of this agreement is found to be invalid it shall not affect the validity of any other part of the Agreement We are licensed by the SgurMiml, Pest Control Board - 333-Guadalupe. SW I-530 Austin, n 28701 512-305-82Si! RP Lee Termite cst Control Cert. Apl.# Cus mer Signatuze pate Apr. 4, 2008 9:42AM Stylecraft Builders, Inc. No,8561 P. 26 New ConstruAtion Subterranean Termite ofAc Ap{rldvel p. �5� os2) $oil Treatment Record Tnts form Is Com lewd tho Hemod Poor Control Compnn� _ iiJb1le rsporong trunM for tins aofodim Aannadw Ll oarna to k-PgoT�m>twtoa par re�onio. urrludulp Oro trio iur rwwMrvj uij7uWW+p. �WU�hbry 0x4dnp data EQi m" Qdillorin0 and mahttmntn0 tfw dais 91"W. and ourrtyledng Mal roViowlr+t 00 dwde m 01 bum'M t M. tins rtnam>attm' O manduloh trtd 1% MWad to dot M bwofite. HUD moy not wlbtl tie bdwvw9 4 aW you am twt ruVred m =nP Bta Ha; turn, unlom R dtopuWs a raururntj va➢d Cub COU01 minds. Srl4 n 24 CFR 200,92W(b)(3) reteths dial the dtoe tar HUD Inourod atntdum must Lv bog of Wrmlto hautds. Thy Intormetion t dOdon loqulres th9 b-IM r to :mtey tzd an mdlbrbod Pout Crndn t amtnm v Pedamed all loqulrod treatment to tm,raifwr and Hurt W2 Wdcr 11.tarcrneos the trootod um aowM udar~advn for orw year. Doildore, pad eonuol oxnPitu e. mmVgo londoro, h mabryw:i and WD US o rowid of trea raw, kf epoe&. Irnn;&a va usa Qw ouurma9vn coldAtC. Tw intmoiation ti nd "&Wired ftx dWw" _ -- rims sport if VAMIE d for iptorrrradanal purpaeas to the bultdor on proposed (now) aonalrumon Cason whoa sail ttoatatont rot pr,:vaAb6n & oUbterran0ah twmito inlaakltion Ic epedflod by t%o bugdor. AreldteoL or roqulrud by tho londw, archltsm. FHA. or VA. A,1 Coro u lot borvicas ato UOiwaon :tto IPae1 cmugi Upuawr and hulider. unlocs 9=4d o.harwlaa. Sootlon 1: General Wormatlan (Treating Ctv)paty tnlortnnlion) —12 A C"r+paty Nantes . CompanyAd4MW GOMPMV Bututesr LPWMa po. W Company Pharw No. FHAlVA Casa Ne. (if any) Soatiatt As guilder Infofntatlon Cry Company Name PAM8 No. $getloA 3: Aropbrty IrKorrstatlon ��y � /� Location of avwbRo (a) Tioutod (Sltgot Atkkg#a .r Loge! DaUtlptlon, City, Ettuo trnd zip) Type of Consttudon (Mora than am twz may bo vtwd,uo) N dab ►nJ 8saomunt L Crawl Otttar Appro�dmwa Depth N F44Mg; Mdolds Indds Typo of Fill Sowun 4. TraabnantInlornanflan Orito(s) of Treatowt(c) ardAd 11va ar Proaz4fr") Haag 04A EPA Aeglstrat(on fee. Approtrknoto Final Mix Solution % -1" ' _ Urear ft. 01 Moaonry Vo;du Apprwtlmato :rra 0J Troetnrvnt Arot1 Sct. fL — uttoRr fL �i Apprtudmele TvW Mom d Soluton Apylled Was treamunt Comt3uted oA oxterl 7 Y.s M No Sar6-oASta=ontAvalWQ7 M Yes La NO New Boma MO Iowa rogviro oonAoo egoemonte rn ha itAuoi Thin form duos nul PrOompt stato taW. AIWMWO COrnmenta �. .— Name or Apa1lcawKs) — _ .. onE` — Ceomtlaa No. (If raqulted by State taw) i7t0 eppBcator hoe usece d a prod= In aotdwtcv tho product Cabal and stall) Mulratrtalts. All iteatra M raatttrlrta and ntothods usod coMPly with club and Wow ng;jlOons. 1, AvlhoAzod Vgrotuio SatsD C1ri�i►s rrvl KAtomentrs. C,ern,ir�nn Palm NFCA4" may MR be UW J"M �� .�uf✓ Dula form KUCWNaCA-Sl&B (U412003i Apr. 4. 2008 9:43AM Stylecraft Builders, Inc. No, 8561 P. 28 SUBTERRANEAN TERMITE PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATE ticansed and regulated under the Texas Structural Pest Control Act RP LEE TERMITE & PEST CONTROL PO Box'9423 • College Station, TX 77842 • (972) 690-8622 • TPCL #11486 — CUSTOMER INF ON: Name: r/ eC� Phone #1: Phone #2: Address: ///Z I/ / % �l '� CRY. 0.6 State: r Zip Code: 5 Location to be Treated: Forall treatirients, ftru 411 be a diagrern showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember that -your architects or design engineers specifkatlons must also be followed, unless they are in violation of the law. Review the consumer information sheet for further inforation. If you have any questions, contact the Rest control wmRamr or the Texas Structural Pest Control Board, P.O. Box 1927, Austin, TX 78767-1927. Telephone number (512) 305.8250. Before conducting a termite preconstruction treatment the company will present a complete diagram of the sWaure Including construction details. When construction prevents performance of a full treatment in accordance with a bid for full treatment, any change to a partial treatment by the company providing the treatment will be permitted if the owner of the structure or the person in charge of the construction and the certified applicator forts pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amended diagram showing the exact areas to be treated. Copies must be sent to the owner of the property within seven days of the application. notes: 411,4 e4ve UNIM Ara Gti pd,�bG Type of treatment proposed: (check all that apply): r1 Full Partial X Wood 0 Bait ❑ Commercial 'Mingle Family Total square feet to be tr ted: . Total linear feet to be treated: .�Ai, Approximate measurements of structures) to be treated: -76�L� A label of be A termiticide(s) is attached. The percentage of the termiticide(s) to be applied at this location is Estimated amount of termdcide to be aDRtied: 113oallon(s). THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED ON BACK (SPCBID4). THE BOARD APPROVED SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT SERVICE. Complete details of warranty V any) Including time period of warranty, renewal options and cost, and obligations of the contracting parties is attached. H the warranty does not include the entire structure treated, the areas Included in the warranty are (specify): A oonsu ' oration sheets also attached. Signature of CA or) niaan Printed Name Date Si�a'ture of C' omer Varffying Receipt of This Document Date REM F 67R UO.2.,wlrm otlDWT WAita COpy. Smice Provider Yellow Copy. Catnmor Form Gesi9W W PON h9~&%C*mwiaW* 14$6782-05. Dab. TX02W Date: �- � f Appoint.l,me: Service Treatment Invoice ,EE ^ ,.fir Am/Pm Route: a Map Code: Frequency: h BhI Q S Y StartTJime: mlpm FiniskTime: aMIPM s Structure: la Crawl P/B Combo a l Type Se»•lee: Init • Regular Follmv up Ono Time Charity of Pets: Dog(g) Cat(s) Bird(s) Ash "Shielding8c Protecting Service Address Homes Against Pasts" ��� • ; _ . ;: , Cost of Service o 1t-�n.� F� rPC #11 * '" Name: Billing: Tax Si Payment by: Address- A� '�'� Total Due S , Cash D City: i' TX Payment S '- Check O W - Phone: Balance $ 1P5'_ Credit Card L a PEST PROBLEMS: age — .�.VeoO T.-tei1 r DIRECTIONS I INSTRUCTIONS: PAYMENT DUE .EQUIP. METH. LOCATIONS) PRODUCT QTY TARGET PEST(S) UPON RECEIPT _ WOOD DESTROYING INSECTS Termidor SC-Fiprooll .A6% SabftrraaeanT'ermites, Ants Slue of'1'aok Ported TernWorS0%V41prord1.06% ��r_/ S"IerracemeTermiles. Sim OrTiwk Ported — Boni-rate-Disodlun Octsboratc7binhydate 50% �J ('�R1 SubterrrneaufNormaserlDrywoal is rruilea,CarpeoterAula, Bcetks, Posted o0 c GENERAL VESTS — Lrvader nPlt-Baygan 1 % Car W nWrAats, Sp1ders, Crkktts, illillipedes, Beales, 7Frinites. a co Demon\VP-Cyayo-Ylueoxypaenyl CaLkrowhes,hli0ipedmSmrhmp F1ks,Tick%Mosyuitoa,Plllbugs, Dimetirptyleydopmpautecarboaylnte 1% Silverfish, Bees, Ants, CarpenterAots, Scorpions, Spiders, - 'tempo l)Itra WP.Cytlalhrir .025*A (Rest) "Is (Except I Jra raah), Cockraaehea, Crkken, EarwhA Nli111pedes, Flies, Frmil I les, Beelks, (gen.surfacesproy,"Unist,cnck&crwke) PillbsSs. Skverlisb,Spiders, Goats, RornMn,►Vhsps,lAiknv Jaclscfa. 'I'alsfar E'L Bifenthrin -2*/D Am is, Centipedes, Codrroackes, Cridmis, Grasshoppers, Scorpions,? ticks, Sihrr83h, Spklcrs. -" 1[axforoe4tydramet1rllan1%-MS% PliarnohAnts,Crickets, Carpenter Ants. LU.poaches,V F'WyclAsls. Cyhick CS Cjlisthrin .05% Spiders, Scor pions, Ants, Carpenter Ants, Carpenter flees, Roaches, Clrlckets, Sllsvrtish, Pboatom .5% Pharoh An% Variety of Avis, Roatekes. FL L Teagard-Pernethris .5% llms,Tickr, Ants, Centipedes, Carpenter Ants, Bees, Wasps. Carpenter Ileum, Cochroaches, Sic 0rickets, Files, Harwlgs, Al W ipedes, Beetles, Plllbugm Suspend SC-Deltanctnrin 4.75% (RL$1) Fleas, Bee4,11cct3es, Roaches, Crickets, Lke, Flies, Scorpions, 71chx, VfSaps i Nyguar+d-Mtttiyletamy 10% (RHS7) 1GR-Growth Regulator -}less, Roaches, Crickets, Flying Imects, Stored Product P nts. Exclle R Pyrdlorin .05% Fleas. M ICE. RODENTS. RATS. MONITORS Fastrne-Bromethotin .01% Mice, Rodents, pals. Bait Station-LaroSnall Glue Boards Me, Rodents, Itais, Bag Mooilorn. QTNE�t SpeekarA-Pyrocidt —44)% Horseflies, 6lesqultoo, Meths, Fleas NSrsps,Horncls,Tlclar, Cockro=bes, z Bifen Wr Blfenthrin .06% Spiders,Anls, Reaches, Silvcrilab, Esnrlgs, Fleas, Suorplon► Equipment: A Compressed Spra)rr P-Paver Sprayer B-Bait Dispenser BS-13ait Station BT-Bait Trap D-Acrosol Can IC -Glue Board If -Hand Duster SSpreader F-Pogger Fh1-Roemer AC-Actisol unit Other o� Laealioos:l-KitcMu 2-3alb(s) 3-Bedromm 4-1)iningRoom 5-Utility 6-Slorage'MommonAreas S-Garage 4-PtrimcwxofStructwe 10-Attic it -Yard 12-Uoderllorne13-Mrehousel-Office lSF.iposedWoodTupfrom Slab Other Method ofThR eats: CC -Crack & Crevice SS -Sub -Slab Injection W-Void Treatment BP-BaitPlacmuent BS-Broadcast Spray PB-Perimeter Barrier BV-Brick Venire WT-WoodTroatme tt PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried. ti .o Licenced by the Structural Pest Control Board - 333 Guadalupe, Suite I-530 • Austin, TX 78701 •512-305-8250 �© SERVICE TECHNICIAN: X-CC- CUSTOMER SIGNATURE: A'�+� �I��SG^' DATE: Please review the Customer Information on the other side of Invoice P.O. Box 9423 • College Station, TX 77842 • (979) 690-8622 • Fax (979) 690-8840 WFl003036 / 001 City oftCollege Station PAGE 1 REQ. DATE: 02/08/08 02/08/08 9:21:03 LOCATION: 4124 MCFARLAND DR LOC ID: 208512 REQUESTOR: STYLECRAFT BUI.LDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/08/08 SCHED COMPLETION: 02/08/08 ******************************************************************************** JOB ORDER RESULT COMMENTS SHEET INDEX COVER SHEET G-1 GENERAL NOTES G-2 SITE PLAN C-1 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 DETAILS S-3 BRACING PLAN S-4 FRAMING PLAN S-5 ROOF FRAMING PLAN S-6 DECKING LAYOUT S-7 ELEVATIONS S-8 FRAMING DETAILS S-9 ELECTRICAL PLAN E-1 FLOOR PLAN A-1 FLOORING PLAN A-2 CABINET LAYOUT A-3 PLAN APPROVAL APPROVED INITIALS DATE ADMINISTRATOR / SUPERINTENDENT / CUSTOMER / NOTICE THIS SET OF DRAWINGS FOR A HOME IS THE COPYRIGHTED PROPERTY OF STYLECRAFT BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL OR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF THE DESIGNERS. 1 ST PLAN PREVIEW SCALE:3/32"=1'-0' i--------------------------i I I I I I I I I , �------------iI 2ND PLAN PREVIEW SCALE:3/32"=V-0" FINISHING NOTES 1 Notes COMMENTS G . G-1 'OVER SHEET B FRONT ELEVATION SCALE:3/32'=1'-0' BUILDIk PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00000339 Date 2/07/08 Application pin number . . . 218021 Property Address . . . . . . 4124 MCFARLAND DR Property ID: 579530-0209-0090 R #: R305171 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SOUTHERN TRACE PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY CLUSTER DEV Application valuation . . . . 112926 Owner ------------------------ Contractor BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1710.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- TRAFFIC IMPACT ANAL (TAZ) 405.00 Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 550426 Permit Fee . . . . 499.00 Plan Check Fee .00 Issue Date . . . . 2/07/08 Valuation . . . . 112926 Expiration Date . . 8/05/08 Qty Unit Charge Per Extension BASE FEE 460.00 13.00 3.0000 THOU BLDG, VAL 100001-500000 39.00 ---------------------------------------------------------------------------- Special Notes and Comments -Make sure to maintain Natural Buffer at back of Property -Right side 10' PRAE -Make sure 2nd Floor Windows are 24" F Mizim ---------------------------------------- -- - -----•----------- BUILDING DEPT REP R SENT TIVE: APPLICANT: Z BUILDING PE�MIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00000339 Date 2/07/08 Application pin number . . . 218021 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Engineered Methods *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 15% the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR BUILDING DEPT REPRSSENTA/7IVE n APPLICANT: BUILDING PEA MIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00000339 Date 2/07/08 Application pin number . . . 218021 ---------------------------------------------------------------------------- Special Notes and Comments TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPIvu��_ OM AND OUTSIDE EACH - ------------------------------------ ----���./.-------------- BUILDING DEPT REP R SENT TIVE: APPLICANT: BUILDIIiG PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00000339 Date 2/07/08 Application pin number . . . 218021 ---------------------------------------------------------------------------- Special Notes and Comments SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC ) *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------------------------------------- Permit Fee Total 499.00 499.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 Grand Total 1249.00 1249.0 .00 ------------------------------------------ .00 .00 BUILDING DEPT REP SEN ATIVE: APPLICANT: BUILDING PEkMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00000339 Application pin number 218021 Page 5 Date 2/07/08 ---------------------------------- - - - - -- - -- -------------- BUILDING DEPT REP W TIVE: APPLICANT: z TEMPORARY•POLE`PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 08-00000340 Date 301260 4124 MCFARLAND DR 579530-0209-0090 R305171 TEMP POLE SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY CLUSTER DEV 0 2/07/08 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 550434 Permit Fee . . . . 20.00 Issue Date . . . . ---------------------------------------------------------------------------- 2/07/08 Valuation . . . . 0 Other Fees . . . . -------------------------------------------------=-------------------------- . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------------------------- BUILDING DEPT REPRESENTATIVE: — APPLICANT: --------�- -� `-------------- APPLICATION FOR BUILDING PERMIT DATE: V0 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 APPLICATION Crnt OF COUEGE STATION (979) 764-3570 (979) 764-3496 FAX TEMP POLE # Pk=hrg d-Dcvdopmew Snvuw W W W.CSTX.GOV ADDRESS/LOCATION: Mc-F:p44,AfJ0 LOT Cl 1-11 BLOCK 9 ✓ SUBDIVISION 50MeT-N -TV -ACE SEC/PH 2 �_ BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext.120 CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext.120 FAX: 690-0348 EMAIL: ewivagg(a)stylecraft-builders.com ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbinq HVAC: Control Tema GOOD CENTS (Residential only): No ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: Conventional Framing PROPOSED USE: Sinale Familv Residence WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPSF_j ENGINEERED HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (fAS) PROJECT. REGISTRATION# EABPRJ N/A VALUATION: $ 112/ 92G TOTAL AREA: 1449 HEATED AREA: 71 10 (Cost of Labor and Materials) Ka QX PUBLIC SEWER SEPTIC/TREATMENT SYSTEM D�X SEWER TAP: 4° SIZE QX WATER TAP: %, / SIZE OTHER TAP: IIIUUU"'"' SIZE 'I y ❑X TEMP POLE GARAGE TYPE: SINGLE ATTACHED C I NUMBER OF BEDROOMS:4 NUMBER OF BATHROOMS: "I INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: F] TRIPLE SIGNATURE OF APPLICANT: \_ a_ / / / *If proposed work involves new commercial codstructidrfor ffcad( commercial property, building elevations are required. Official Use Only z -c)c S+&ha Plans Examiner Nft / ,Pl�l� Composition 0 s to an existing Zoning Official Mo�i,wl r Fire Mars al�v Co ments: (JEWor NO Energy Code'Compliance Information r % Glazing of exterior walls '- Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites ❑ Chemical Termiticide Treatment (Soil Treatment) I I t % R13 R30 R19 .35 .53 13 Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. PLAN REVIEW (*t/q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Simko COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# (23- DATE: BUILDING ADDRESS: 14 a M C,i (Z] I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated K II. Framin : Floor, Wall, Ceiling and Roof Requirements Nq/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex N OK 1. One -hour rated extending to roof deck O E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not rovided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an 0. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. OK K PLAN REVIEW (*// I ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning dDevelopment Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details NAIbKT 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairwaydetails 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements M AJb K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: W 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location 4 1 (*t/q" CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N OK A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements NqOK A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window LI-values, etc. Zoning Ordinance Requirements — Ordinance 850 N K Permitted use for district Density requirements Minimum lot size Setbacks Easements .Required parking Street Ordinance Requirements N KC J$K Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NAjbk Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NAgnK Does not block any water course or divert any flow Elevation certificate needed A K "APPROVED PLANS. PER IRC SECTION R106.3.1." - r PLANS EXAMINER 02-s-_08 DATE -w Permit # Permit Date CREScheck Software Version 3.7.3 NJ( Compliance Certificate Project Title: 1711 Report Date: 02/04/08 Data filename: S:IACADIRESCheck11711.00-Master.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 11 % Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: College Station, TX 77845 Stylecraft Builders, Inc. Stylecraft Builders, Inc. 4090 SH 6 South 4090 SH 6 South College Station, TX 77845 College Station, TX 77845 979-690-1222 x127 979-690-1222 x127 jsaucier@stylecraft-builders.com jsaucier@stylecraft-builders.com Como r ..- Maximum SHGC: 0.40 Your SHGC: 0.40 Wall 1: Wood Frame, 16" o.c.: 2254 Window 1: Metal Frame:Double Pane with Low-E: 16 SHGC: 0.40 Window 2: Metal Frame:Double Pane with Low-E: 16 SHGC: 0.40 Window 3: Metal Frame:Double Pane with Low-E: 16 SHGC: 0.40 Window 4: Metal Frame: Double Pane with Low-E: 16 SHGC: 0.40 Window 5: Metal Frame:Double Pane with Low-E: 4 SHGC: 0.40 Window 6: Metal Frame:Double Pane with Low-E: 4 SHGC: 0.40 Window 7 Twin: Metal Frame:Double Pane with Low-E: 16 SHGC: 0.40 Window 7 Twin: Metal Frame:Double Pane with Low-E: 16 SHGC: 0.40 Window 8: Metal Frame:Double Pane with Low-E: 4 SHGC: 0.40 Window 9: Metal Frame:Double Pane with Low-E: 16 SHGC: 0.40 Window 10: Metal Frame:Double Pane with Low-E: 16 SHGC: 0.40 Window 11: Metal Frame:Double Pane with Low-E: 4 SHGC: 0.40 Window 12: Metal Frame:Double Pane with Low-E: 13 SHGC: 0.40 Window 13: Metal Frame:Double Pane with Low-E: 3 SHGC: 0.40 Window 14: Metal Frame:Double Pane with Low-E: 4 SHGC: 0.40 13.0 0.0 163 0.670 11 0.670 11 0.670 11 0.670 11 0.670 3 0.670 3 0.670 11 0.670 11 0.670 3 0.670 11 0.670 11 0.670 3 0.670 9 0.670 2 0.670 3 1711 Page 1 of 2 Window 15: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 16: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 17: Metal Frame:Double Pane with Low-E: 6 0.670 4 SHGC: 0.40 Window 18 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 18 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 19: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 20: Metal Frame: Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 21: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 22: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 23: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Door 1: Solid: 20 0.500 10 Door 2: Glass: 18 0.440 8 SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: 873 30.0 0.0 31 Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0' 127 0.0 132 Floor 2: All -Wood Joist/Truss:Over Unconditioned Space: 24 13.0 0.0 2 Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. sed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the andatory nts li n the REScheck Inspection Checklist. Sr�fr_Ec2a.� 9 D8 Builder/Designer Company Name Date Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 1711 Page 2 of 2