Loading...
HomeMy WebLinkAboutRES2008-00330, 08-331�� �� � r r � ,� (7/15/2008) Amber Carter Re: Calling for C.O. @ 29z3lMclaren Dr� Page 1 i From: Terry Boriskie To: ' Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 7/14/2008 4:58 PM Subject: Re: Calling for C.O. @ 2923 Mclaren Dr Contacted Stylecraft Via -email to notify of issues. Terry Boriskie City of College Station Residential Plans Examiner Ofc. 979-764-3744 Fax 979-764-3496 >>> Paul Schoenfeld 7/14/2008 3:48 pm >>> NO for CO. Sewer buried Flagged. Paul >>> Gina Southerland 7/14/2008 9:07 AM >>> BP# 08-330 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.aov PREPARED 7/14/08, 9:01:38 INSPECTION TICKET PAGE- 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/11/08 ------------------------------------------------------------------------------------------------ ADDRESS 2923 MCLAREN DR SUBDIV: SOUTHERN TRACE PH 2 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 579530-0207-0160 APPL NUMBER: 08-00000330 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 3/17/08 BB BLDG, FOUNDATION -SLAB TIME: 17:00 3/17/08 AP March 17, 2008 8:52:25 AM acarter. 03/17/2008 04:33 PM BB PDA Strings up. Slab ground installed. B115 01 4/15/08 RH BLDG, FRAMING TIME: 17:00 4/16/08 DP April 11, 2008 2:44:59 PM glsouth. Metal straps require min 3-16d nails at top and bottom plates and min 2-8d nails at each stud. Need draftstop for all chases Need joist hangers at RTA. OKAY TO INSULATE B115 02 4/17/08 RH BLDG, FRAMING TIME: 17:00 _ 4/17/08 DP April 16, 2008 2:26:05 PM npadilla. 04/17/2008 11:51 AM RH PDA Did not fix previous notes. B115 03 4/18/08 RH BLDG, FRAMING TIME:, 17:00 4/18/08 AP April 17, 2008 1:44:12 PM glsouth. B130 01 4/18/08 RH BLDG, INSULATION TIME: 17:00 4/18/08 AP April 16, 2008 2:26:20 PM npadilla. 13125 01 7/11/08 BI BLDG, FINAL TIME: 17:00 ,fit? �3 July 11, 2008 1:24:47 PM glsouth. -------------------------------------- COMMENTS AND NOTES ------ - - -------------------------- f .Apr, 4. 2008 9;43AM' Stylecraft Builders`, Inc, No. 8561 "Shielding & Protecting Homes Against Pests" Renewable 5 Year Subterranean Term.fte Retreatment Agreement (Does not cover any other species of Termites) 0g, 330 This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph). Customcr Name Date Billing Name if different Street Address of treated structure Billing Address if different 0,5 77,� V-1 City State Zip Code City State Zip Code Initial Termite Cost na S / mo Home Phone Work Phone Additional Renewals Paid Other 100-0 Type ofTxeatmeot� `PrePa.rtial Bait YPre-Treat TAX 01 Treatment for: .Y vention Control of Subterranean Cash,Check# Total $� Termites Payment $ r Notes: Balance S� Credit Card: Type Exp. Date Card dumber S c r cubterra n T r�1M Retreatment Guarantee: RP Lee Termite and Pest Control will retreat the structure for Subterranean Termites at no cost to the customer, if an infestation of Subtemmean Termites is found, as ]ong as the original treatment is paid in full and the customer is current on their yearly renewals. This Agreement will expire in one (1) year unless the customer elects to pay the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termite and Pest Control may approve additional warranty years after the five (5) years with an additional iucrease is the yearly warranty fee. The guarantee does not cover any damages to the structure or contents of the customer, The customer agrees to control all eondusive conditions tbat.may cause relnfestation. If the structure is modified, added on to, altered, or if the soil treatment around the structure is removed the customer must mutact RP Lee Termite and pest Control and pay for additional treatment in order to keep the guarantee in effect If the customer does not pay for additional treatment the tetr eatro t guarantee can be cancelled. ot, Renewal Fee: Customer may elect to rtmcw the rctrcatmcnt guarantee for additional year... The renewal fee is S .0_ plus tax. The renewal fee is due on or before the annual anniversary date or paid S --' plus tax every third (3) month with inspection. Maintalping the Guarantee: The customer agrees to correct all condusive conditions, at owner's expense, as they exist or as they occur in the future in order for the guarantee not to be cancelled. Customer will make the structure available for inspootiotts and treatments as requested by RP .Lee Termite and pest Control. RtjA$pgrrtion: RP Lcc Termite and Pest Control will reinspect the structure at customers request or any other times RP Lee Termite and Pest Control deems ncccssary. RP Lee Tcrmitc and Pest Control recommends that the customer call and set up an annual inspcc- tion at the time of customers yearly renewal, oaf ers This agreement may be transferred to a new owner with the payment of a transfer fee of S , copy of the Wood Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest Control. This Subterranean Termite Retreatment Guaranteelloes p t prevent and Is not intended to control other forms of Termites aDnmod, Formosan, etc.). Wood Boring Beetles. Carpenterr AM—C !WWer Bees Rood Rot. Fungus. Decay, gr any other wood destroying insects orQrgain sms. Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shrill be final, binditS, ton -appealable and may be entered and enforced in any court having jurisdiction in accordance with the kbderal Arbitration Act. br milpft of Liability: Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled up in certain areas around the home, drill holes may need to be made in floor coverings such as We or linoleum or in cabinets next to pipe areas, and holes may need to be cut in walls. Customer agrees not to hold RP I ec Termite and Pest Control liable for these damages, or treatment techniques, or other damages that may occur during treatment. Agmimcimt This Agreement shall be the entire agreement between customer and RP LecTcrmitc and Pest Control..lf any part of this agreement is found to be invalid it sball not affect the validity of any other part of the Agreement. We are licensed by the Structural Pest Control _BoazcL- 333—Go_ e_dalnne Suite I-k30 Austin, TX 78701512-105-8250 a 7�4/4A7 41ew e4s v,/-,Y 5--,?Y,00' RF Lee Tory e & Pest Control Cert. Apl.tt Cuitomer 96iturc Date v Apr. 4. 2008 9:43AM S t y I e c r a f t Builders', Inc, No, 8561 P. 30 New Construction Subterranean Termite olna Apyto ( p. IC/3 ,°oo 1 Soli Treatment Record TNs form Is corn •W%d ih—rr- ilr.Oncod Pool Gen ral C omWY rt pottfn0 Oufnml ht qm mfeW¢ n d Kacnoatlrn Is 04MAM to LAMP r8 rNnw9t W ruporii0 DiduGlflgl}tp �0 {nt NN�rvf oi1n1( (�6 ioarCi�n�) o41a9 data W=j;% 94mmg and matrak na Ma asta nead(rl. and ooraplodnq and twowft rm," cattbcaw tht( Tw d W ri rTb a ornbab �/ I t. MUI04 CMB Wnand is rldaurod 10 d=n bWVfi(e. HUD M" f* wood Iva bltuma o' and you ore not rsgtdt �+ 061 wftw. won 24 CFR 200.A24d(b)(3) repdmb NO tbo ages for FWD burred ONClvrab must W Uoe of tumrltn ha ulds. Thus Wamsti0n caltnttloa 1046'm rho 5'JldLr to :eI y itnr An aldhwged Poo! CWrL+t uxnWW peed sA (equbed iroe0nwd 1cr woe ma, and (hat m owMcr gnsrar000s the vowed um agal= tntamw.. for au yw. OtAldaro, poet Gowrror mmWim nvr tjaf)o londma, homaujyws, and HlU as o record of trwo wnt of fim:Wu InAtm wifA uau Ow bifurnu]vn edQLY. a MW inror hgWi o out oon kl&ud araFdaobit. _ - - You:,oporl isolritte(!tar IntamaUanaf puryas�a tome twlldur on proposes (now) t rvlxUUGror cososullor, sell troxtr lent lar pravanLon of eubkwn�naan Iomite inflctaCan )c wdfled by tho I�Jlklw, mchneol, or requtrrnf by thv londor. archiraou FHA, or VA All 00ntrAcxy 10, 60rvicoa nro Uotwoon 710 Most contour f3parator and builder. untont ttaterf othanviaa. l;ao(lon 1: General lnformetlon (Tres% Co jjmpany Inloaar(naron) Company Nomtx �. 'I.GRee /r+/lmIre Q4r? City Company Addreae - -- Company Buslnsss timnea Qfa. ! CompM Pharw No. �^ i FFWVA Caw Ne. (0 any) _.. - cocoon 21 BMW jrtw nt(on Company Nam) -.. Ph= No. » -- seetlan 3: Property Inlormauon Location of OvuoApe (a) Tloulad (81mal kk7r9e4 x Lopai Description, City, We and ilp) G r.6 - Z,/ Tod of Con&Uu Won (Moro Iran ono bux n>tty bo 01104,1,00) 1 Slab u ya&arnarrt Crawl Other Approxlmate Dopy; of FOOfingr; Outelde Inside ter.. Typo a F11 - - Secliwr 4:'ft4abnm>t lnlorruxUan t3aSa(e) of Trwalmont(e) W Brand rftm at Pt*kxa(6) Lkmd-- F-PA I9epI&v4don Na Zl AWOxlmalc Final Mix WuWn % �i3 Llnc:a Y 01 Musa VOW _ /lpproxim m Vza of Troalmont AMA: : s. It Llnaar>t _. �� .- rr)' ---- ApWow mato Total adons d SolWan NOW was mmord wffyloted an oxww PAY" No 8errlcaAgwwn ntAvaWlbto7 Le Yea L3 NC Note: SontO Slate laws roquko advAce spraemente rn ba )Ltuni Thia form dvoa nut preempt state raw. COMmm'ws Name tsAPPOUlor(s) - --�� Ctt wcaaon No. (if roqukad by State taw) d-fI1111 Tho app "Wr has used a product in aa;ordwm wkh tho pradurd labor and slato requlrementt,. Al uaa;rwra nalortitt and niathode vaod comply with =0 and fadoral repufAtione. 77°-d cY Audwdzad $ wwwo 1Y mIrta HUD wll wwoo6m lots 'pod rintomEdbt CcnvSrTw mnY h137R1 Sn afffi MI !aW Y foal insmhvtn (7 C U.S.G. f ly loin 1017; 31 Folm NPCA-9" may 6112 bo UQOd ►four l4Uo-xaCA#8 (aa1z003) Apr, 4. 2008 9:44AM S t y I e c r a f t Builders, Inc. No, 8561• -P. 32 i SUBTERRANEAN TERMITE PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATE Licensed and regulated under the Texas Structural Past Control Act I RP LEE TERMITE & PEST CONTROL PO Box 9423 • College Station, TX 77842 • (972) 690-8622 + TPCL #11486 —CUSTOMER INFO TIO ! Name: C Phone #1,. Phone #2: Address: City. Stale: Zip Code: Location to be Treated: a9 93 A c4melu C1, 5 . rl 1-700VY For all treatments there will be a diagram shoWng exady what will be treated plor to the beginning of treatment Review the pesticide label provided to you at this time for minimum treatment standards. Remember that'your architects or design engineers specifications must also be followed, unless they are In violation of the law. Review the consumer Information sheet for further information, If you have any questions, contact the nest C,2W l comoarry or the Texas Structural Pest Control Board, Po. Box 1927, Austin, TX 78767-1927. Telephone number (S12) 305-8250, Before conducting a termite preconstruction treatment, the company will present a complete diagram of the structure including construction details, when construction prevents performance of a full treatment, In accordance with a bid for fug treatment, any change to a partial treatment by the company providing the treatment will be permitted 9 the owner of the structure or the person in charge of the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions, The agreement must be attached to the contract with an amended diagram showing the exact areas to be treated. Copies must be sent to the owner of the property within seven days of the application. notes: lJD 9ACi412e �/e'47 we i9�2 • • /�� Ong 1012/9� Type of treatment proposed: (check all that apply); 7 Full Partial gWood ❑ Bak ❑ Commercial Crngle Family Total square feet to be treated: -*'� . Total linear feet to be treated; all. Approximate measurements of structure(s) to be treated: zsz G'L A label of /,91146,41R termiitidde(s) is attached. The percentage of the termriticide(s) to be applied at this Ipcafion is Estimated amount of termtticids to be applied: Z / gallon(s), THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED ON BACK (SPCBID-4). THE BOARD APPROVED SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT SERVICE, Complete details of warranty (iany) including time period of warranty, renewal options and cost, and Obligations of the comracdng pariles Is attached. If the warranty does not Include the entire structure treated, the areas Included in the warranty am (specify); V A consuw4information sheet * also attached. xyll Signature o nfclann Prints Name Date Signature of CuRomer Verifying Receipt of This Document Date rtm:stPaxoz • ' OtlOOA7 WhlroCopy •8orvimPrewEer YNIowCopy- Customer �D�,;PWWoPftWby&MccMtamn.� I-W&78td275,p�OWTAGM Service 'I%eatment Invoice Route: d,7— Map Code: Start'l'lme: a)Wpm Finish Time: amfpm 'type of ScrvJce: initi Regular lrollav Up One Time Charity Service Address Name: Address- 9.9'3 6► 4eA.) City: 6-5 TX 1'ay-6 Phone: 1 � 1E:F�mi & pis 1f ciiNI'H01 Date: 3'Zri-Uu Appoint.Thne: Al rimdpin Mcegnency: Wow] Q S V a Structure: 'lz(jy-",rj Crawl PIB Combo Pegs: Dog(s) Cai(s) Bird(s) Fish � y� 4 Cost of Service S %ad- Tax S Total Due S Payment $ Balance $7 PEST PROBLEMS: 6, dC-41eo47 DIRECTIONS I INSTRUCTIONS: Billing: s Payment by: Cash ❑ .o Check D # Credit Card a PAYMENT DUE EQUIP. METH. LOCATIUN(S} PRODUCT QTY TARGET PEST(S) UPON RECEIPT WOOD DESTROYING INSECT'S 1brm1dor SC-Fiproni1.06°% SubterraannTerrnites, Acts Saxe er•1'ank Postctil IbrmldorSOVitFipronil06•A _! SubtermncenTermiks. SiacofTank (bated Bow•a�arc-1NsorllnmlDctaboratel'etrahydate50•!. 71 SubtcrraneantFornomjVDryKnod'fcrinites,CarpcnterAnts;ticetlea, Pegged ' W GENERAL PESTS — le adcr 111'1411aybron 1 % Carpenter Ant; SpkWra, Crickcla, M111ipcdes, Bcetles,'l'� nkcs. rn De3amr WP-Cyace-Phcnoayphe,ryl Cockroaches, Millipedes, Sowbogs, Files; ltdcs, hlorquitos, Hibmgm, y- Dimethyeyleydopropanecarbonylaie 3 % Silvertislr, Bees, Ants, CsrpcntcrAats, Scorpions, Spiders. - 'RKUPDVRrawp-cylluthris.0251%(ticut) Ants (ExceptPharaoihCoulimmehes,Crickets,Earwk%N11111pedes,Dlles,Fr•uitMies, Bregks, _ (gen. surface spray, spot, mist, crack & crevice) Pilltrugs. Slltrrifi sh, Spiders, Goats, Hor eels, Wags, Ydknv Jackets. TalslarEZRientbrict 2% Ants. Cc■tipcdes,CackeoacbmvCrkkch6Grassbuppcn,Scorp[orr;,Ticks,Sllvrrrish,SpLdm. MaxforrallydraorethylosiM-2.151A PharsubAoh,Crickets,CarpentcrAaba 1:,&Roache5,Wrektyo1Auts. CykickCS Cyftulhr1a .Q5% Spiders, Scorpions, Ants, CorpecterAots,Carpenter Bees, Roaches, Crlckcls,SIhw@sh. FY.EAS Phantam .5% Pharoh Aots, Variety of Ants, Roaches. Terrgard-Permetirrin .5% Fleas,11chs,Anls, Centipedes, CarpeaterAnts, Beer, W aspa, Carpenter Bees, Cockroorhes, CrkkeN Mes, Earwi;, Millipedes, Beteks, FIMugs. Suspend SC-Deltauetnrin 4.75°% (RlST) Fleas, Bets, Betties, ltoachcs, Crickets, Lice, flies, Sco redo rrs,'1'ick s, V lYta ps. Nyguard-Methyleteaxy 10% (RFS'l) 1GIt Groutle Regulator -fleas, Roaeies, Crickets, Flying loseels,Slaved Product Pest% Excite R YyrMhrin ,0594 Fleas. MICE. RODENTS. RAT& MQN1TORS Fastrac-Bronclhalln .01 % lalkc, Rodents, Rate. OTHER Bait Station-LurgdSsrall Clot Boards hike, Rodents, Rats, Dug alon[tors. Speckox-Pyreeide .50% llamell", Mosquitos, Moths, l<]cas, Wasps, Horncls,'Jlcks, Cockmachcs, z Biren Uf Btrenthrin A6'/. o Spiders,Aofa, Roaches, Slhier0slr, Eanvi)�s, Fleas, Smrplars - rn I✓aulnment: A -Compressed Sprayer P-Power Sprayer B-Bait Dispenser BS-Bait Station BT-Bait Trap D-Aesasol Can G-Glue Board H-Nand Buster S-Spreuder F-Cogger FNI-Foamer AC-Actisol unit Other Locations: (-Kitchen 2-BaQt(s) 3-Bedrooms 4-Dining Room 5-Utility (-Storage 7-CommenAreas S-Garage 9-Periaxlerof Structure 10-Attic It -yard 13-Under Home 13-Wlareltoisse 14-Offim IS-ExpwcdNN16W 2' up from Slab 016cr Method of7Yeatments: CC -Crack & Crevice SS -Sub -Slab lnjoetion VT -Void Treatment BP-]3ait Placement BS-Broadeast Spray PB-PPieiimt:ter Barrier BV-Brick Venire PVT -Wood Treatment PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried. W Licenced by the Structural Pest Control Board - 333 Guadalupe, Suite I-530 • Austin, TX 78701 •512-30�5--42�50 SERVICE TECHNICIAN: -0?/IrC- CUSTOMER SIGNATURE: 9C11 !l/ Z5 Ong i'%/l' DATE-3—2,v'49.C' louse revlew the Castomer Information on the other tAdc of Invoice P.O. Box 9423 • College Station, TX 77842 • (979) 690-8622 n Fax (979) 690-8840 WFl003026 / 001 City of .CO1165 Staition PAGE 1 REQ. DATE: 02/08/08 02/08/08 9:10:53 LOCATION: 2923 MCLAREN DR LOC ID: 208586 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/411 ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/08/08 SCHED COMPLETION: 02/08/08 ******************************************************************************** JOB ORDER RESULT COMMENTS AMok ww aff0mam More Home, Less Money SHEET INDEX COVER SHEET G-1 GENERAL NOTES G-2 SITE PLAN C-1 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 ETAILS S-3 RACING PLAN S-4 FRAMING PLAN S-5 ROOF FRAMING PLAN S-6 DECKING LAYOUT S-7 ELEVATIONS S-8 FRAMING DETAILS S-9 ELECTRICAL PLAN E-1 FLOOR PLAN A-1 FLOORING PLAN A-2 NET LAYOUT A-3 PLAN APPROVAL APPROVED INITIALS I DATE ADMINISTRATOR / SUPERINTENDENT / CUSTOMER / NOTICE THIS SET OF DRAWINGS FOR A HOME IS THE COPYRIGHTED PROPERTY OF STYLECRAFT BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL OR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF THE DESIGNERS. BUILDING ENVELOPE i' era• . aa'a• 1 ST PLAN PREVIEW SCALE:3/32'=1'-0' 2ND PLAN PREVIEW SCALE:3/32'=l'-0' FINISHING NOTES 1 Notes COMMENTS Iu RnA. LOCATION A O O N a Q w SHEET: G-1 COVER SHEET CFRONT ELEVATION SCALE:3/32'=1'-0' I 1 0' EAR PUE I I I I I I I e I I I, nne . 5 F' i . I. I Iw I Z IN76S6-0 I ISOD LL .i I . SOD. Q 1580 SF XU' cV M�W I ,Ir I 1- a 1 I , II I I I I I I I LK I I S I I I 1 ONT S T K - 2923 MCLAREN DRIVE jjSI _ LK 1 SOUTHERN TRACE R UE LOT - 16 BLOCK - 7 PHASE - 2 SOD 71 SF SOD . . . . . .372 SF. 2923 MCLAREN DRIVE 1 SITE PLAN SCALE:1'=20'-0' LOCATION BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979) 764-35.70 FAX: -.(979) 764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00000330 Date 2/07/08 Application pin number . . . 468870 Property Address . . . . . . 2923 MCLAREN DR Property ID: 579530-0207-0160 R #: R305142 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW .Subdivision Name . . . SOUTHERN TRACE PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY CLUSTER DEV Application valuation . . . . 106326 Owner Contractor ------------------------ ------------------------ BCS DEVELOPMENT CO STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1610.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 550319 Permit Fee . . . . 481.00 Plan Check Fee .00 Issue Date . . . . 2/07/08 Valuation . . . . 106326 Expiration Date . . 8/05/08 Qty Unit Charge Per Extension BASE FEE 460.00 7.00 3.0000 THOU BLDG, VAL 100001-500000 21.00 ---------------------------------------------------------------------------- Special Notes and Comments -Make sure 2nd Floor Operable Windows are 24" AFF Minimum -Narrow Wall Bracing Prescriptive Methods ---------- *ALL BRANCH CIRCUITS THAT SUPPLY OUTLET IN DWELLING _ ----------------------------------- --------------- BUILDING DEPT REPRE�7NTATIVE: - APPLICANT: BUILDING PEFfMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00000330 Date 2/07/08 Application pin number . . . 468870 ---------------------------------------------------------------------------- Special Notes and Comments UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 1501 the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FR THE I SIDDE�Ejj��y,,,. ----------------------------------------------- ---------- BUILDING DEPT REPRESEJNTATIVEj APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00000330 Date 2/07/08 Application pin number . . . 468870 ---------------------------------------------------------------------------- Special Notes and Comments WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING N PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20o A .4 OR LOW FACTOR, D _ ___ =w ---------------------------- - -- - ----------------- BUILDING DEPT REPRES#TATIVj: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00000330 Date 2/07/08 Application pin number . . . 468870 ---------------------------------------------------------------------------- Special Notes and Comments ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Pa i Credited Due -----------------------------------------------�-- ---. -`------------- BUILDING DEPT REPRESYNTATIVY: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . Application pin number . . . ----------------- ---------- Permit Fee Total 481.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1231.00 Page 5 08-00000330 Date 2/07/08 468870 -------------------- 481.00 ---------- .00 .00 .00 .00 .00 750.00 .00 .00 1231.00 .00 .00 ------------------------------------------- ---- -- - •------------ C44 BUILDING DEPT REPRES#NTATIYE: APPLICANT: TEMPORARY POLE,PERMTT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00000331 Date 2/07/08 Application pin number . . . 552109 Property Address . . . . . . 2923 MCLAREN DR Property ID: 579530-0207-0160 R #: R305142 Application type description TEMP POLE Subdivision Name . . . . . . SOUTHERN TRACE PH 2 Property Use . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY CLUSTER DEV Application valuation . . . . 0 Owner ------------------------ Contractor BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 ---------------------------------------------------------------------------- (979) 690-1222 Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 550327 Permit Fee . . . . 20.00 Issue Date . . . . 2/07/08 ---------------------------------------------------------------------------- Valuation . . . . 0 Other Fees . . . . . . . . . ---------------------------------------------------------------------------- TEMP ELECT POLE CONNECT 45.00 Fee summary Charged ----------------- Paid Credited Due ---------- Permit Fee Total 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------------------------- --- - z- - ----t-'-------------- BUILDING DEPT REPRE,9ENTAT,IVE: APPLICANT: CITY OF COLLEGE STATION Plamdng & Derelopmrmr SerrLen ADDRESS/LOCATION: . LOT I% BLOCK _ APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV _; m4j� DA APPLICATION # TEMP POLE # "1�s pp / SUBDIVISION 50 TT IkOO 1-eAC9 SEC/PH_ BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext.120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext.120 FAX: 690-0348 EMAIL: ewivagg(a)-stylecraft-builders.com ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION • SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: Conventional Framing PROPOSED USE: Single Familv Residence WALL BRACING METHOD: PRESCRIPTIVE 0 APA PORTAL FRAME W/ CSPS ENGINEEREI HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TS) PROJECT REGISTRATION# EABPRJ NIA VALUATION: $ i0b ") NO 2 TOTAL AREA: no HEATED AREA: 1610 (Cost of Labor and Materials) l I �X PUBLIC SEWER 'U 1 SEPTIC/TREATMENT SYSTEM �X SEWER TAP: 4° SIZE QX WATER TAP: %" OTHER TAP: SIZE QX TEMP POLE SIZE r GARAGE TYPE: SINGLE ATTACHED F-4 NUMBER OF BEDROOMS: b NUMBER OF BATHROOMS: INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/Or Masonry FOUNDATION TYPE: Slab On Grade ROOF TYPE: Composition DOUBLE a TRIPLE a 4AC.1E� CARPORT SIGNATURE OF APPLICANT: 14,1 ) /-- *If proposed work involves new commercial constructioA-6r f cad, commercial property, building elevations are required. ��_ Official Use Only Z -.S ��� — _S4-a4e Igs Plans Examiner Z-4 lclba& "4&'js _ A"Ofi-t f�4 /3 Zoning Official ,CafflTents: Y rNO to an existing Fire Marshall Diergy CodeCompliance Information % Glazing of exterior walls - 11) - % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling Z (vaulted areas/no attic) R19 Glazing SHGC (Solar Heat Gain Coefficient) .35 Glazing U-Factor 53 R value of ductwork R6 / A/C SEER Rating 13 J— Protection Against Subterranean Terfnites ❑ Chemical Termiticide Treatment (Soil Treatment) Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other z ''Verification of application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning&Development Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# QQ OCR — 3 C7 DATE: _ BUILDING ADDRESS: AJ b/2 I. Foundation Requirements- Minimum City Foundation Standards A. Concrete minimum compression strength of 3000 PSI NA/ B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' Ion must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. II. Framing: A. Wood foundation details indicated Floor, Wall, Ceilingand Roof Requirements Girder or sill dimensions, grade & species OK NA/ B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in du lex K E. F. 1. One -hour rated extending to roof deck Header sizes indicated on plans Emergency bedroom egress OK N AAM 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an 0. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. OK K i CITY OF COLLEGE STATION Planning d Development Services III. Stairway Requirements A. Stairway Details N 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 0 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location 0 ; (*� CITY OF COLLEGE STATION Planning d Development Servieei PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NAB A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 A/Ml Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NAdOW Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." NS EXAMINER DATE Permit # Permit Date 0 REScheck Software Version 3.7.3 8/"' Compliance Certificate Project Title: 1611 Plan Report Date: 02/04/08 Data filename: S:IACADIRESCheck11611.00-Master.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 10% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: College Station, TX 77845 Stylecraft Builders, Inc. Stylecraft Builders, Inc. 4090 SH 6 South 4090 SH 6 South College Station, TX 77845 College Station, TX 77845 979-690-1222 x127 979-690-1222 x127 jsaucier@stylecraft-builders.com jsaucier@stylecraft-builders.com Maximum SHGC: 0.40 Your SHGC: 0.40 Wall 1: Wood Frame, 16" o.c.: 1096 13.0 0.0 76 Window 1: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 2: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 3: Metal Frame: Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 4: Metal Frame:Double Pane with Low-E: 21 0.670 14 SHGC: 0.40 Window 5: Metal Frame:Double Pane with Low-E: 21 0.670 14 SHGC: 0.40 Window 6: Metal Frame:Double Pane with Low-E: 21 0.670 14 SHGC: 0.40 Window 7: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 8 Twin: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 8 Twin: Metal Frame: Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Door 1: Solid: 18 0.500 9 Door 2: Glass: 20 0.440 9 SHGC: 0.40 Wall 2: Wood Frame, 16" o.c.: 974 13.0 0.0 75 Window 9: Metal Frame: Double Pane with Low-E: 6 0.670 4 SHGC: 0.40 Window 10: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 11: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 12: Metal Frame:Double Pane with Low-E: 3 0.670 2 1611 Plan Page 1 of 2 SHGC: 0.40 Window 13 Twin: Metal Frame:Double Pane with Low-E: 13 0.67Q 9 SHGC: 0.40 Window 13 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: 818 30.0 0.0 29 Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0' 122 0.0 127 Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. Th op ed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with thendatory r ments ' t in the REScheck Inspection Checklist. `5NLCs�� 2 k 05 Builder/Designer Company Name Date Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 1611 Plan Page 2 of 2