HomeMy WebLinkAboutRES2008-00317, 08-319a PREPARED 6/02/08, 8:08:52 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/02/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 3321 KEEFER LOOP SUBDIV: WILLIAMSGATE PH 1 CONTRACTOR ROBBIE ROBINSON LTD PHONE (979) 764-9000 OWNER ROBBIE ROBINSON, LTD PHONE PARCEL 660030-0104-0010 APPL NUMBER: 08-00000317,RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PEU4IT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 2/12/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00 2/12/08 AP February 11, 2008 12:33:16 PM kwolfe. 02/12/2008 12:10 PM RH PDA Strings up, slab ground installed. B120 01 2/20/08 RH BLDG, FRAMING -PARTIAL TIME: 17:00 2/20/08 AP February 20, 2008 10:34:51 AM glsouth. APA FRAMING February 20, 2008 3:58:47 PM kwolfe. B115 01 3/10/08 RH BLDG, FRAMING TIME: 17:00 3/10/08 AE March 5, 2008 11:28:11 AM kwolfe. March 10, 2008 4:56:15 PM kwolfe. Reconnect a/c duct in frount room and tape seal all penetrations through tyvek by insulation. B130,01 3/18/08 RH BLDG, INSULATION TIME: 17:00 3/18/08 AP March 18, 2008 10:53:36 AM glsouth. B125 01 6/02/08 BI II BLDG, FINAL TIME: 17:00 �g May 30, 2008 10:56:17 AM ccourt. / -------------------------------------- COMMENTS AND NOTES --------- a- /� 72.50' 33�,� KEEFER LOOP -1 K-4 T-1 SITE PLAN SCALE: 1 "=20'-0" JUN 09,2008 12:32 ROBBIE ROBINSON LTD MR-0-2008 20:16 From:A-1 TE ES 5796968019 To:7649000 Page 1 Paee:2�8 0 SUBTERRANEAN TERMITETRECONSTRUCTION IMSCLOSURE FOR EACH ESTIMATE for all treatments. there will be a diavn slowing exactly what will be treated prior to the bcginn4 of treatment. Review the pesticide label provided to you at this time .for ni6num trestmcut standards. Ref ember ft-your arehitais or design enocera speeifleations muA aho be Nowed, unless they are in violation of the law. Review the coteaumer information sheet for further i dm%natiom If you have any question's, contact the pest control wTVany or the Texas Depattalant of Agriculture, Structural Peat Control Service, P,O, Box 12847, Austin, Texas 78711-2847, Phone: (512) 305-8250, Name of Customer: Robbie Robinson Limited Location Name: Property Address Customer Address: 3800 State Hwy 6 S, Ste 104 Location to 'Great: 3321 Keefer Loop College Station, TX 77845 College Station, TX 77945 Type ofTreatment Fun t j Partial [X] wood [ ) Bait [ ] Commercial [X] Single Family A label of Bora-Care Termitieide(s) is enclosed. The percentage of the tonTaicidc(s) to be applied at this location is: 23.0% WarraV Infomadon provided must include the Complete Details of any Warranty provided and the following: 27me Period of Warranty; Renewal Options and Cost; and Obligations of the Contracting Pardex if the warranty does rx)t include the Mire structure treated, the areas included in the warranty are: (specify) Total Square Feet to be Treated.; 1739 Total Linear Fed to be Treated: 365 Approximate Measummc nts of the Structure(s) to be Treated: iwa a ffmAwd Sigvturc of Certified Applicator or Tmhati M Completing Estimate A-1 Tq!M"es -- Nattte ol'Pest Control Company Rou a C. Brebad Printed Name 03/03/2008 Datc TPCL 11932 TPCL. No. ^ Lleemd and r%Wafed under the Tatu R&wtvral Past U►nbnt Act 'reins Dupumment of Avioultura, S`nucturni P w Cum tmi service, P.O_ Box 12847, Austin, Teas 78711.2$47, Phone: (5 j2) 3Q5.$2$0 MAR 13,2008 21:38 Page tof4 `5893655 Page 2 JUN 09,2008 12:32 ROBBIE ROBINSON LTD 9796968019 MAR-13-aM 20:16 From:A-i TEFfES I ITo:7649HB0 Paee:3'8 Page 2 Description of Structure(,) See Blueprints/Diagrams Additional Information Befom wnductiog a termite preconstrucxion trmtrru nt, the company will ptescra a complete diap= of the grucxure including eonstnrctxin detaik When construction prevents performance of a fbll treatment, in accordance with a bid for full treatn=, any change to a partial trew=it by the company providing the treatment will be pcxmnittod if the owner of the structure or the person in charge,of the construction pad the certified applicator for t1tC pest control company sign a statement attesting to the wnstruction conditions. The agreement must be attached to the contract with an a rnended'diagram showing the exact areas to be treated. Copies must he sent to the owner of the property and to the Structural Past Control Board within seven days of the application. THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED (SI'CBM 4). TUE BOARD APPROVED SUBTERRANEAN TERMITE PREC:ONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUC`nON TREATMENT SERVICE. *'Fhh form includes the ntdnimnm requirements and information, It may dw include or be revised to Include a company logo and additional information. Pate 2 et 4 MAR 13,2008 21:39 '5893655 Page 3 E 9796968019 To-7649000 Pase:4/8 Page 3 JUN 09,2008 12:33 ROBBIE ROBINSON LTD MAR-13-2M 20:16 From:A-1 T v S Am T.er: Res . 979-589.1203 Oft r 979-589.365S Pax 7343 Wixon Road. P.O. Boer 501. Bryan, IX 77805 TPC:L 11932 r� LIFETIME SUBTERRANEAN TERMITE CONTRACT Contra= Namoz Robbie ROM11*011 ILl1UIted Propurky Name. Property Addreae Gmtractur Address: 3900 State Hwy 6 South, $tc 104 Property Address: 332I Keefer Loop Co fte Station, TX 77845 , College Station, TX 7784S Property Description: Revidenee - serf Care Wood Pretreatment for Subterranean Termites Mcctive: 03/03/2008 through 03/0=010 11reatunutnt Cost: $243.46 Yearlypmcww'. S150.00 + tax — $161.63 Treatment Areas: JXJ 2' 11igb foteriur watt Studs J 8' High Interior Wall Studs f 121 Wgh Exterior Wall Transfa Coat' $150.00 (Charged to Bttyer after sale of Property) A-1 Termites will annually extend this omtroot to the ( lamu far the LIFE'I M of the Prop" provided the yearly renews) is paid before the end of the previous caatract period. Iracdve subtereaneoa tarmite inlieetation is found while under contract, A-1 Termites will retreat the infested area at no charge. If the property sella, the new (lamer must pay the transfer coat and yearly renewal et the contract is void. A-1 Termitas marvots the right to n:vise the annual ranewal cdtarge Arr the first year and each yrar Aur that. A-1 Termites does NOI' guarantee against aay present or future damage to this ptnperty or ita conrenup not wilt A-1 Ta mites provide for any repairs that maybe nec& ary. Any additions or alterations to the psaperty drawn an the $raph/bhteprints dated ammom will anew A-1 Ttarniten the right to change the amount of the annual renewal. A -I Tcrmitcx muxt he nruilied of these ehatlges, and the addidom-i or alterations must be properly trcawd by A-1 Termites at the expense of the Owner, or this contract is Invalid. l�wwtti � di�et�erd Robbie Robinuou L11t I" ' hate Rumall C. BrvInad C.A. for A-1 Termites "cad red add ragWWk1 antlertho TezaeStraeturalPcd Contral Act 1'maa Dgxro ad of Agmitum Rwewml Fan Caroni Savica P.O. Dos 12447. Anvh1 Tcxy 79711.2847, thane: (512) "54259 .. Pop 3of4 MAR 13,2008 21:39 `5893655 r Page 4 WFl002271 / 001 City of College Station ,. PAGE 1 REQ. DATE: 02/05/08 02/05/08 16:24:10 LOCATION: 3321 KEEFER LOOP LOC ID: 207836 REQUESTOR: ROBBIE ROBINSON ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/05/08 SCHED COMPLETION: 02/05/08 JOB ORDER RESULT COMIENTS BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGt STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner 08-00000317 Date 2/05/08 613629 3321 KEEFER.LOOP 660030-0104-0010 R304777 RESIDENTIAL, 1 UNIT DETACHED NEW WILLIAMSGATE PH 1 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 114774 ROBBIE ROBINSON, LTD 3800 SH-6 S STE 104 COLLEGE STATION TX 778455840 Contractor ROBBIE ROBINSON LTD. 3800 STATE HIGHWAY-6 SOUTH COLLEGE STATION TX 77845 (979) 764-9000 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE DRYWALL IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1739.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 406.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 549840 Permit Fee . . . . 505.00 Plan Check Fee .00 Issue Date . . . . 2/05/08 Valuation . . . . 114774 Expiration Date . . 8/03/08 Qty Unit Charge Per Extension BASE FEE 460.00 15.00 3.0000 THOU BLDG, VAL 100001-500000 45.00 - - - - - - - - - - - 7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Special Notes and Comments - - - - - - - - - - - - - - - - -Corner Lot and Side Street has 15' PUE ----------------------------------------------- ---- - -- - - --�-------- BUILDING DE REPRESENTAT qVii E '" APPLICANT: � k�A A BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00000317 Application pin number . . . 613629 Special Notes and Comments -If Study Area Closets have characteristics then outside this room. -Narrow Wall Bracing Dining Room Area and 32" OSB Minimum. *ALL BRANCH CIRCUITS UNIT BEDROOMS SHALL INTERRUPTERS) Page 2 Date 2/05/08 hanging rods and has bedroom you must add smoke detectors inside and Fully Sheathed with 18" Minimum APA Deleted Side Lite at Front Door to get THAT SUPPLY OUTLETS IN DWELLING BE PROTECTED BY AN ARC -FAULT CIRCUIT *PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. *ELECTRICAL SHALL BE INSTALLED PER 2005-National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUIID BUILDING DE APPLICANT: REPRESENTA r BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE` STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 08-00000317 Date 2/05/08 Application pin number . . . 613629 ---------------------------------------------------------------------------- Special Notes and Comments *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 15% the Values Shall be R-13 and R-30, above 15% the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTE PLANS MUST BE -----------------------------------------------------"---------- BUILDING DEPI\REPRESENTATIVEI:N APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00000317 Date 2/05/08 Application pin number . . . 613629 ---------------------------------------------------------------------------- Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST.PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *ADD SMOKE DETECTOR(S) PER NOTES ON PLANS *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20o A .40 OR LOWER FACTOR AND ABOVE 20o TO 30o A .35 FACTOR OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ------------------ ----------------------- ------ ---- IV• - -------- BUILDING DEM REPRESENTATIVEt _ ., BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840. PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00000317 Date 2/05/08 Application pin number . . . ---------------------------------------------------------------------------- 613629 Special Notes and Comments *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 ---------------------------------------------------------------------------- Fee summary Charged --------------------------- Paid Credited ---------- Due Permit Fee Total 505.00 ---------- 505.00 ---------- .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 350.00 350.00 .00 .00 Grand Total 855.00 855.00 .00 .00 BUILDING DEPI\REPRESENTA' \\ R APPLICANT: ---�.!•-- A-0660440-:1 ---------- TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner 08-00000319 Date, 2/05/08 712121 3321 KEEFER LOOP 660030-0104-0010 R304777 TEMP POLE WILLIAMSGATE PH 1 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 ROBBIE ROBINSON, LTD 3800 SH-6 S STE 104 COLLEGE STATION TX 778455840 Contractor ------------------------ ROBBIE ROBINSON LTD 3800 STATE HIGHWAY 6 SOUTH COLLEGE STATION TX 77845 (979) 764-9000 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 549857 Permit Fee . . . . 20.00 Issue Date . . . . 2/05/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 20.00 20.00 .00 .00 Grand Total 20.00 20.00 .00 .00 -------------------------------------------- BUILDING DEP\REPRESENTATIVE: APPLICANT: Y►: N APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CI IN OF COLLECE STATION (979) 764-3670 (979) 764-3496 FAX PLrrmirg d7hudapmrnt.Frri•, WWW.CSTX.GOV ADDRESS/LOCATION: -pew Loan './ For, LMce u'�e cWy DATE: V TRCCI APPLICATION # TEMP POLE # '? LOT I ✓ BLOCK 4 ✓ SUBDIVISION Wi I`10-rAS CST2 SEC/PH I BUSINESS/OWNER NAME: Rob 1�__e, R,ob►nson Um PHONE: -7ficL - f C06 CONTRACTOR/HOMEOWNER: b i n%n, PHONE: -74A S c06 CONTACT PERSON FOR REVIEW COMMENTS: '��,kjeA-)nA P, _ PHONE:�� 7 LL\ 4417 - FAX: l(A - - I. txx, EMAIL: k_kq 60. C�brv, ELECTRICIAN: Y\Cux &— _C\- \ C/ PLUMBER: 1►C.�L HVAC: 1r\keA GOOD CENTS (Residential only): ACCESSORY/STORAGE M VING RE -ROOF ADDITION EW CONSTRUCTION* SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEL/RENOVATION* TENTS DESCRIPTION OF WORK: RP6 a cnL e.. PROPOSED USE: STRUCTURE USE: tLer'Le HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE PPROVAL:' TEXAS ACCESSIBILITY)TANDARD (T S) OJECT REGISTRATION# EABPRJ VALUATION: $ � r �/ TOTAL AREA: aTL� HEATED AREA: (Cost of Labo and Materi Is) 2 PUBLIC SEWER SEPTIC)TREATMENT SYSTEM (� ''SEWER TAP: WATER TAP: (JJlYY11.1}�Z SIZE n OTHER TAP: SIZE ZN SP POLE ,�'rL) NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: z INTERIOR WALL TYPE. - EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: ^ GARAGE TYPE: SINGLE F-1 DOUBLE ATTACHED E X 4 SIGNATURE OF APPLICANT: *If proposed work involves new commercial col e\ commercial property, building elevations are re •••••••••••••••••••• /b Cen.ae,� LO , a-q-08 Plans Examiner 5;c14 s+xzd t%s Is t PvE tug-&, ice. —,i" LYE Ac4, S / Lbl_k rv-014 ACHED TRIPLE Q. A �!J CW— tction`or facade improvements/renovations to an existing d. ' Official Use Only Zoning Official w r v Energy Code Compliance Informadon % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites ,go g6z ❑ Chemical Termiticide Treatment (Soil Treatment) M Chemical Termiticide Treatment (Field Applied Wood Treatment) bov-A t�6 ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. 3321 KeePev l,oap �S �a�e gol� Y) so r ��`e� PLAN REVIEW (*,., ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# D _ 3 i rl DATE: a r 0 8 BUILDING ADDRESS: 3 3, Q I O I. Foundation Requirements- Minimum City Foundation Standards N A O A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated K II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck Q#JOK E. Header sizes indicated on plans NNW F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an 0. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. K OK PLAN REVIEW (*//q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning & Development Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details IWAYOK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA IT 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location (*t/q" CITY OF COLLEGE STATION Planning d Development $ends PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NAWO Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for sin le Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 Nkoq Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER DATE