HomeMy WebLinkAboutADDN2008-00309Monday, May 19, 2008 10:13 AM To: Building Services From:, 776-6066 Page: 1 of 1
Bryan Electric & Automation Concepts
P.O. Box 1732 Bryan, Tx. 77806
(979) 776-9631
Fax (979) 776-6066
Date: May 19, 2008
Subject: Permit #08-309_,_._
To: City of College Station, TX
I wish to immediately cancel electrical perm' --it at 701 Herford Sty
I assume no responsibility for any electrical work beyond installing conduit through the pool house
foundation.
Please call me at your convenience if you have any questions or concerns.
Thank you,
Michael Young
owner
Master Electrician license #A-65 City of Bryan, TX
#EM-212 City of College Station, TX
#8412 State of Texas
#3193 State of Colorado
State Of Texas electrical Contractor License #20293
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Tenant nbr, name . . . . . .
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00000309
658433
701 HEREFORD ST
195400-0230-0010
R24108
Date 2/04/08
POOL ROOM
RESIDENTIAL, ADDITION
COLLEGE PARK
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
13000
Owner Contractor
------------------------ ------------------------
BLAKELY, CRAIG HUNTER HOMEOWNER
701 HEREFORD ST 1101 TEXAS AVE
COLLEGE STATION TX 778402945 COLLEGE STATION TX 77840
--- Structure Information 000 000 POOL HOUSE ADDITION
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . IMPACT/PRORATA FEES PAID NA
HEATED AREA 430.00
----------------------------- ----------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . AC
Permit pin number . 549469
Permit Fee . . . . 75.00 Plan Check Fee .00
Issue Date . . . . 2/04/08 Valuation . . . . 13000
Expiration Date . . 8/02/08
Qty Unit Charge Per Extension
BASE FEE 15.00
12.00 5.0000 THOU BLDG, VAL 1001-50000 60.00
----------------------------------------------------------------------------
Special Notes and Comments
-Make sure to have 6'-8" clearance above fixtures under the
stairway.
-Upstairs to be unfinished until future, discussed with
homeowner and it is not to be conditioned space.
-Narrow Wall Bracing Fully Sheathed
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
----------------------------------------------------------------------------
BUILDING DEP REP ESENTATIVE:
APPLICANT: _� 0 �� •
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00000309 Date 2/04/08
Application pin number . . . 658433
----------------------------------------------------------------------------
Special Notes and Comments
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR'ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 15% the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
BUILDING DEFT REIPRESENTATIVE:
APPLI
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000309
Application pin number . . . 658433
Page 3
Date 2/04/08
Special Notes and Comments
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC -RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 2001 A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
BUILDING D
ENTATIVE:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
---------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00000309 Date 2/04/08
Application pin number . . . 658433
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*U-Factor Ratings for Window % up to 150-. is .65, from 15% to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS: CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total
Plan Check Total
Grand Total
75.00 75.00 .00 .00
.00 .00 .00 .00
75.00 75.00 .00 .00
BUILDING DEPT ,PRESENTATIVE:
APPLICANT
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning & Drvelopment Serviaf
WVVW.CSTX.GOV
ADDRESS/LOCATION: %O ( r `ed'-e_4v S'L °
1 For
rOOftee Use Only
DATE:
�d;V "`iRCCREG
APPLICATION #
TEMP POLE #
I OT ! :�,y BLOCK 23 SUBDIVISION Co l Z SEC/PH
_BUSWESS(OWNER NAME: Ct-, Lq 2Z](]�)-ACUlS PHONE:
CONTRACTO OMEOW t< < l PHONE:
CONTACT PERSON FOR REVIEW COMMENTS: PHONE: �'(' c� 1
FAX:
ELECTRICIAN: &k-'e- [CV I-(b
HVAC: D XO(L 044
EMAIL: aqe%j C"�s,2�fie-r4,V14se''Paint _
PLUMBER: �12 �,oc ��� Sa°tlueU� `F t`J[2(u
GOOD CENTS (Residential only):
CESSORY/STORAGE MOVING RE -ROOF
ADDlTIUN R NEW CONSTRUCTION* SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) J GLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEURENOVA\TION/*
DESCRIPTION OF WORK: I-000 (70oL IC�dzGt, �`�c.Q. )(PC/, 0 S'V"u rr
PROPOSED USE:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ � � � putt TOTAL AREA: HEATED AREA: q30
(Cast of Labor and Materials) 403
C PUBLIC SEWER
SEPTICr'TREATMENT SYSTEM
SEWER TAP:
WATER TAP:
OTHER TAP:
® TEMP POLE
GARAGE TYPE
SIZE
SIZE
SIZE
SINGLE
ATTACHED' a
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE
TRIPLE
DETACHED F-] CARPORT
SIGNATURE OF APPLICANT: -
*If proposed work involves new commercial con ruc Ion or facade i vements/renovations to an existing
commercial property, building elevations are required.
0000000000000000000000000000000000000000000too
000000o0ooeoeo
Official Use Only
Plans Examiner
() U (i tj- tc0 t ec-d
— rV f 5-t'a�
Zoning Official
�><vl2cs tip Ste; 0-S
0Eo
ments:
r NO
Energy Code Compliance Information
% Glazing of exterior walls /0 /o
Insulation R value of exterior walls 913 �
Insulation R value of ceiling 1 (flat areas) �30
/
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient) • q0
Glazing U-Factor & S- /
R value of ductwork
A/C SEER Rating 3
Protection Against Subterranean Termites
C4 Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
Garage
Residence
Transition
Brick Bench
Height Here
Serving & Eating Bar
Serving Bar
Cooker area
0
Badujet Equipment
Location Wail Fountain "Neptune" TOW 6'-q'
Gunite wall with pool
-145 Tile face of wall
n
IIC'elcirnm6LrdeepIF
Pual Badujerr
10OW Light
�uuunuunw.
Pool,,
-Swimming
,
Light
'110OW
,have
---Exterior of E?ram to
I®
stone
allow.
'
I
I
ll:l�:i! III:;i!111:!i:J'!11!i!li�ill�i�':1!li tllill:l!i llli'
uop of planter -2
n 0
a
11 •
I' •O"
.I�
og of planter +10
Garden Gate
Stucco Wall
n
2I:cncc
51/2"
--Poured Concrete
with brick c p
ne Coping
by owner bytractor
all
Tow +a-1"
Stucco Wall
Tow +6-5i11
broom Flnish Conc.
Pool Equipment
Location
�IN—
PLAN REVIEW
(*fl ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& DevelopmentSericu COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 0 _ 30
DATE:
BUILDING ADDRESS: 20
I. Foundation Requirements- Minimum City Foundation Standards
N
A. Concrete minimum compression strength of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier Emil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F. Protection Method used for Termites.
G. Wood foundation details indicated
FWOK.
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E. Header sizes indicated on plans
N AtO K)
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twent 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O. Roof covering
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
OK
WND K
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
PlanningDevelopment Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairwa Details
N OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N K
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
(*.., f/"" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAM
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA(OK)
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N QQK
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N O
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NAI
Does not block any water course or divert any flow
Elevation certificate needed
_4�_K
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER DATE