HomeMy WebLinkAboutRES2007-01319I
6
i1762113 10°b OP4
r
0
y
PREPARED 7/31/07, 7:59:21
INSPECTION TICKET PAGE 17
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 7/30/07
ADDRESS
. : 921 TURTLE DOVE TRL
SUBDIV:
CONTRACTOR BRANDON BERRY CONSTRUCTION PHONE (979) 690-8670
OWNER
PHONE
PARCEL
230100-0207-0280
APPL NUMBER: 07-00001319 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
5/15/07 OC
BLDG, FOUNDATION -SLAB TIME: 17:00
5/15/07 AP
May 15, 2007 12:21:06 PM kwolfe.
May 15, 2007 12:21:38 PM kwolfe.
B115 01
6/12/07 OC
BLDG, FRAMING TIME: 17:00
6/12/07 AP
June 11, 2007 1:30:01 PM glsouth.
B130 01
6/13/07 OC
BLDG, INSULATION TIME: 17:00
6/13/07 AP
June 12, 2007 3:25:34 PM acarter.
WEDNESDAY AFTERNOON
B125 01
7/30/07 BI
BLDG, FINAL TIME: 17:00
A
July 30, 2007 4:17:29 PM acarter.
EARLY
--------------------------------------
COMMENTS AND NOTES ---------(-----------------------------
�tZ�
Nle
Date: 7/31 /2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1319
Address: 921 TURTLE DOVE TRL
Type
Inspection Type Code
si tus
Inspection Result Comments
Description
13100
BLDG, FOUNDATION -SLAB
IC
May 15, 2007 12:21:38 PM kwolfe.
Page 1
WF0893926 / 001 City of College Station PAGE 1
r
REQ. DATE: 04/30/07 04/30/07 14:36:23
LOCATION: 921 TURTLE DOVE TRL LOC ID: 204540
REQUESTOR: BRANDON BERRY CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/30/07 SCHED COMPLETION: 04/30/07
JOB ORDER RESULT COMMENTS
Amber Carter - Re: Calling for C.O. for 921 Turtle Dove Trl 11
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 8/1/2007 10:26:43 am
Subject: Re: Calling for C.O. for 921 Turtle Dove TO
ALL OK.
PAUL
>>> Amber Carter 7/31/2007 1:01 PM >>>
by #07-1319
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001319 Date 4/30/07
Application pin number . . . 702875 '
Property Address . . . . . . 921 TURTLE DOVE TRL
Property ID: 005401-0207-0280
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . DOVE CROSSING PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 107712
Owner
Contractor
------------------------
------------------------
BRANDON BERRY CONSTRUCTION
3330 TRIPLE BEND
CIR
COLLEGE STATION
TX 77845
(979) 690-8670
--- Structure Information
000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
CONCRETE SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1632.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
NC
Permit pin number .
499483
Permit Fee . . . .
484.00 Plan Check Fee
.00
Issue Ddte . . . .
4/30/07 Valuation . .
. . 107712
Expiration Date . .
10/27/07
Qty Unit Charge Per Extension
BASE FEE 460.00
8.00 3.0000 THOU BLDG, VAL 100001-500000 24.00
----------------------------------------------------------------------------
Special Notes and Comments
Narrow Wall Bracing Fully Sheathed with 12" Simpson Panels
at garage returns.
BUILDING DEPPT RREPRESENTATIVE:
APPLICANT: l
BUILDING PERMIT ,
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 07-00001319
Application pin number . . . 702875
Page 2
Date 4/30/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH M ASURED AT THE
-----------------------------------
----- --- --- --------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001319 Date 4/30/07
Application pin number . . . 702875
----------------------------------------------------------------------------
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of•exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
BUILDING DEPT REPRESEENTATIVE:
APPLICANT: a,
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00001319 Date
4/30/07
Application pin number . . . 702875
----------------------------------------------------------------------------
Special Notes and Comments
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 484.00 484.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1234.00 1234.00 .00
.00
-
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning d Development Services
DATE: \\ TRCC REG I
APPLICATION #
TEMP POLE #
ADDRESS LOCATION. �/ o5S r r)g w.0
LOT �l BLOCK ✓ SUBDIVISIO//NJJ 00 <_ C (-05 "'�'� SEC/PH Z`
BUSINESS/OWNER NAME: / c< •�a(/e� l �r PHONE:
CONTRACTOR/HOMEOWNER: c" PHONE: �S^7►"� / �w
CONTRACTOR ADDRESS: 73 3 3 c> ••, �,� �-
ELECTRICIAN: fz_:� i` e--ff +� PLUMBER: 61%
HVAC: D rc 5 it ve�s GOOD CENTS (Residential only)'
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL
` TENT/CANOPY C
DESCRIPTION OF WORK: 5 1 n f �2 �4 �n r (�% !` F'S'+�1'Cn c C
PROPOSED USE: -1
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGI`�REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) P OJECT REGISTRATION# EABPRJ
VALUATION: $ TOTAL AREA: HEATED AREA: 3 2-
(Cost of Labor and Materials)
PUBLIC SEWER
F) SEPTIC/TREATMENT SYSTEM
SEWER TAP:
WATER TAP:
SIZE
3 r +
SIZE
OTHER TAP:
SIZE
C� TEMP OLE
GARAGE TYPE: SINGLE 71
ATTACHED
ti_
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE ® TRIPLE
DETACHED _I I CARPORT
3
Gm n c r- e S lq
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facRO6 improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
_L Plans Examiner
t-V (� st"� �j/ sTM,,sMj
Zoning Official
Comments:
(7)orNO
Fire Marshall
Energy Code Compliance Information
d
% Glazing of exterior walls l o
Insulation R value of exterior walls i
Insulation R value of ceiling 1 (flat areas) -3 o
Insulation R value of ceiling 2 (vaulted areas/no attic) /
Glazing SHGC
Glazing U-Factor ,
R value of ductwork
A/C SEER Rating C 3
Al
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# d _ 1
DATE: 3
I
BUILDING ADDRESS:
9 Z1 --6)4- v-e
I. Foundation Requirements- Minimum City Foundation Standards
NA/ K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
Ajb K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing plan or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
X(OK
A. Stairway Details
@90K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
ff,90K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Re uirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NAIPqV
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N AJtW
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
WOK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PL MIN R
q-- ,,7o -1)7
DATE