HomeMy WebLinkAboutRES2007-01316so
s
PREPARED 8/13/07, 12:04:05 INSPECTION TICKET PAGE 13
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/13/07
------------------------------------------------------------------------------------------------
ADDRESS . : 3923 DEVRNE DR SUBDIV:
CONTRACTOR ARDEN'S HOME CONSTRUCTION PHONE (979) 846-8788
OWNER . . PHONE
PARCEL . . 244030-0816-0090
APPL NUMBER: 07-00001316 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/09/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/09/07 AP May 9, 2007 9:37:08 AM glsouth.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 6/06/07 OC BLDG, FRAMING TIME: 17:00
6/06/07 AP June 5, 2007 10:27:55 AM acarter.
WINDOWS ARE ON BACKORDER W/ HOPE LUMBER, SHOULD BE IN ON
FRI.
B130 01 6/07/07 JGM BLDG, INSULATION
6/07/07 AE Schedule for later Thursday afternoon.
Thanks,
Steve Arden
06/07/2007 04:42 PM JGM PDA
a/c duct to porch needs to be removed
B125 01 3//p7BI BLDG, FINAL TIME: 17:00
/(3A fir 0` August 13, 2007 9:17:04 AM kwolfe.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
�� �• a 2 , •Q•r 3 i �` 3 i�2- e
Date: 8/13/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1316
Address: 3923 DEVRNE DR
Insp.
Inspection Type Code
p.
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
06/07/2007 04:42 PM JGM PDA
B130
BLDG, INSULATION
IC
a/c duct to porch needs to be removed
M110
MECH, FINAL
IC
August 6, 2007 12:54:39 PM acarter.
Page 1
WF0893923 / 001 City of College,Station PAGE 1
REQ. DATE: 04/30/07 04/30/07 14:33:42
LOCATION: 3923 DEVRNE DR LOC ID: 203032
REQUESTOR: ARDEN'S HOME CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/30/07 SCHED COMPLETION: 04/30/07
********************************************************************************
JOB ORDER RESULT COMY=S
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 8/14/07
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
Owner . . . . . . . . .
244030-0816-0090
3923 DEVRNE DR
COLLEGE STATION TX 77840
EDELWIESS GARTENS PH 8
BLK 16 LOT 9
SINGLE FAMILY RESIDENTIAL
Contractor . . . . . . ARDEN'S HOME CONSTRUCTION
979 846-8788
Application number 07-00001316 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved
/f •
. . . . . . . JtA�
BuMiding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001316 Date 4/30/07
Application pin number . . . 497548
Property Address . . . . . . 3923 DEVRNE DR
Property ID: 005401-0816-0090
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 175000
Owner
Contractor
------------------------
------------------------
ARDEN'S HOME CONSTRUCTION
311 CECILIA LOOP
COLLEGE STATION
TX 77845
(979) 846-8788
---------------------
Structure Information 000 000 ----------------------
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1891.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. NC
Permit pin number
. 499491
Permit Fee . . .
. 685.00 Plan Check Fee
.00
Issue Date . . .
. 4/30/07 Valuation . .
. . 175000
Expiration Date .
. 10/27/07
Qty Unit Charge Per Extension
BASE FEE 460.00
75.00 3.0000 THOU BLDG, VAL 100001-500000 225.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
BUILDING DEPT REPRESENTATIVE:
------------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE '
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001316
Application pin number . . . 497548
Page 2
Date 4/30/07
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
Narrow Wall Bracing Fully Sheathed with 1 side of garage
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
corner being APA With 18" Minimum
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL -
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
--------------------------- - - - -- ------------
BUILDING DEPT REPRESENTATIVE: /%
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001316 Date 4/30/07
Application pin number . . . 497548
----------------------------------------------------------------------------
Special Notes and Comments
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00001316 Date
4/30/07
Application pin number . . . 497548
----------------------------------------------------------------------------
Special Notes and Comments
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 685.00 685.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1435.00 1435.00 .00
.00
---------------------------------------------"4------ //---�-7----�-=.---------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00001317
592151
3923 DEVRNE DR
005401-0816-0090
TEMP POLE
Date 4/30/07
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
ARDEN'S HOME CONSTRUCTION
311 CECILIA LOOP
COLLEGE STATION
TX 77845
(979) 846-8788
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. NC
Permit pin number
. 499509
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/30/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------------------------
BUILDING DEPT REP, ESENTATIVE:
APPLICANT:
------yt---- A---- j---------
F ���� Use (/���
�� �R
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
DATE: CC
APPLICATION#
1101 TEXAS AVENUE
'�J^
COLLEGE STATION, TX 77840
/ L"�
TEMP POLE * L /— I
CITY OF COLLEGE STATION 43570 979 784-3498 FAX
A—ing dd Dr 4r pmrnr S—i- (979 ) 78( )
W W W.CSTX.GOV
°LOCATION: • 9 13
ADDRESS/ Devrne dr.
9 BLOCK J&/SUBDIVISION EDELWEISS GARTEN PHASE -' SEC/PH 8�
LOT /
BUSINESS/OWNER NAME: Ardens of B/CS. Inc
PHONE:695-8072
CONTRACTOR/HOMEOWNER: Paul & Barbara Reynolds
PHONE:903-938-9483
CONTRACTOR ADDRESS: 311 CECILIA Loop COLLEGE STATION 77845
ELECTRICIAN: Glen Gibson PLUMBER: Danny Sustaire _
HVAC: Tommy Gergani GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) x NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION' SWIMMING POOL
Required)
DESCRIPTION OF WORK: Single family residence construction
STRUCTURE USE: Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL
OR DESIGN REVIEW COMMITTEE APPROVAL: yes
TEXAS ACCESSIBILITY STAND9RD (TAS) PROJECT REGISTRATION# EABPRJ 1507
VALUATION: $175 D 7
_ TOTAL AREA:2809 _ HEATED AREA:1891 _
(Cost of Labor and Materials)
DX PUBLIC SEWER
NUMBER OF BEDROOMS: 3
❑ SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS: 2
I�
SEWER TAP: �
INTERIOR WALL TYPE: DRY WALL
J�
®X WATER TAP: —
EXTERIOR WALL TYPE: BRICK VANEER
SIZE
❑ OTHER TAP:
FOUNDATION TYPE: SLAB_
SIZE
®X TEMP POLE
ROOF TYPE: COMPOSITION
GARAGE TYPE: SINGLE O DOUBLE TRIPLE
ATTACHED 9E7ACHED ARPORT O
SIGNATURE OF APPLICANT: �jlc
'If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only C ents:
N-30-01 S rNO
Plans Examiner Zoning Official
7
l�
S s
W l i �� AA>�2A� C G ��
N,
{ Deleted: _....._................1
Deleted:
................................................+
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls j
i
Insulation R value of ceiling I (£';at areas)
f
Insulation R value of ceiliag-2 (vaulted areas/no attic)
,z
Glazing SHGCj"
1
Glazing U-Factgr f
R value of -ductwork
A/C, SEER Rating
IF-]
.I9
.30
N�
.40
.l 3
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# d 7 _ 3
DATE: ` O
BUILDING ADDRESS:
a Ike..,, rAJ e �.
I. Foundation Requirements- Minimum City Foundation Standards
NAf K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
0410&
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished Floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated bn plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
&PIK
K
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N AJW
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
I
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/OV
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
- - Ix "__
NS EXAMINER
DATE
Permit Number
REScheck Compliance Certificate Checked By/Date
2003 IECC
REScheck Sofiware Version 3.6 Release 2
Data filename: C:\Program Files\ART Inc\CbiefArchitect 10.0 Full Version\BUSINESS
FILES\ARDEN\DEVRNE LOT9.rck
PROJECT TITLE: EDELWEISS GARTENS
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.11
DATE: 04/12/07
DATE OF PLANS: APRIL 2007
PROJECT DESCRIPTION:
DEVRNE, BLOCK 17, LOT 9
DESIGNER/CONTRACTOR:
DESIGNS IN RESIDENCE - FROTHY ROSE
STEVE ARDEN - ARDEN CONSTRUCTION
COMPLIANCE: Passes
Maximum UA = 610
Your Home UA = 347
43.1% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1:
Metal Frame with Thermal Break:Double Pane with Low-E
SHGC: 0.40
Door 3: Glass
SHGC: 0.14
Door 6: Glass
SHGC: 0.14
Door 7: Solid
Door 8: Solid
Gross
Glazing
Area or Cavity Cont.
or Door
Pehmet R-Value R-Value
U--Fact
iIA
1891 30.0 30.0
32
2352 13.0 3.6
142
217
0.650
141
20
0.140
3
20
0.140
3
20
0.650
13
20
0.650
13
Heat Pump 1: Air Source, 6.8 HSPF, 13 SEER
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the
mandatory requirements liste4 in the RESchecl Inspection Checklist.
Builder/Designer/%YL/_� j�� Date 'r'