PREPARED 10/09/07, 12:02:20 INSPECTION TICKET PAGE 4
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/09/07
------------------------------------------------------------------------------------------------
ADDRESS . : 3856 OLDENBURG LN SUBDIV: EDELWEISS ESTATES PHS 12
CONTRACTOR BENCHMARK - DBA G D T INC PHONE (979) 690-7117
OWNER . . PHONE
PARCEL . . 244000-1224-0070
APPL NUMBER: 07-00001314 RESIDENTIAL, 2 UNITS NEW (DUPLEX)
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/08/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
5/08/07 AP May 8, 2007 9:11:17 AM glsouth.
May 8, 2007 4:52:54 PM glsouth.
STRINGS UP SLAB GROUNDS INSTALLED
B115 01 7/10/07 OC BLDG, FRAMING TIME: 17:00
7/10/07 AE June 14, 2007 8:42:22 AM kwolfe.
07/10/2007 10:47 AM OC PDA
protection needed for fridge boxes in firewall.
B130 01 7/12/07 BH BLDG, INSULATION TIME: 17:00
7/12/07 AP July 12, 2007 2:40:57 PM kwolfe.
It July 12, 2007 2:41:13 PM kwolfe.
B125 O1 10/09/07 BLDG, FINAL TIME: 17:00
October 9, 2007 10:18:59 AM glsouth.
----------------------------------- CONTINUED ONTO NEXT PAGE --l---------------------------------
Aa
PREPARED 10/09/07, 12:02:20
INSPECTION TICKET
PAGE 5
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 10/09/07
------------------------------------------------------------------------------------------------
ADDRESS
. : 3856 OLDENBURG LN
SUBDIV: EDELWEISS ESTATES
PHS 12
CONTRACTOR BENCHMARK - DBA G
D T INC PHONE (979) 690-7117
OWNER .
.
PHONE
PARCEL .
. 244000-1224-0070
APPL NUMBER: 07-00001314 RESIDENTIAL, 2 UNITS NEW (DUPLEX)
------------------------------------------------------------------------------------------------
PERMIT:
PLBG 00 PLUMBING PERMITS SUB: H & A PLUMBING
(979)690-8844
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
P100 01
5/04/07 JGM
PLBG, ROUGH IN TIME: 17:00
5/04/07 AP
May 3, 2007 4:03:58 PM glsouth.
P105 01
6/15/07 OC
PLBG, TOP OUT TIME: 17:00
7 AP
June 15, 2007 11:00:43 AM acarter.
P125 01
10/019/077-N BI
PLBG, FINAL TIME: 17:00
GAS AND SEWER MUST BE COMPLETED.
October 9, 2007 11:52:53 AM glsouth.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
Date: 10/9/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1314
Address: 3856 OLDENBURG LN
Insp.
inspection Type Code
Description
p.
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
May 8, 2007 4:52:54 PM glsouth.
B100
BLDG, FOUNDATION -SLAB
IC
STRINGS UP SLAB GROUNDS INSTALLED
B115
BLDG, FRAMING
IC
07/10/2007 10:47 AM OC PDA
B115
BLDG, FRAMING
IC
protection needed for fridge boxes in firewall.
B130
BLDG, INSULATION
IC
July 12, 2007 2:41:13 PM kwolfe.
E150
ELEC, FINAL
IC
09/20/2007 11:40 AM RH PDA
E150
ELEC, FINAL
IC
Label meters by final.
M100
MECH, ROUGH IN
IC
07/09/2007 10:16 AM RH PDA
M100
MECH, ROUGH IN
IC
Seal around RTA opening by framing.
Page 1
(7/12/2007) Kim Wolfe Insulation request inspection result, 3859 & 3858 Oldenburg,#07-1188 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 7/12/2007 10:42 AM
Subject: Insulation request inspection result, 3859 & 3858 Oldenburg, 107—r
CC: Carter, Amber; Wolfe, Kim
Print for file
Inspected insulation, 3859 & 3858 Oldenburg, #07-1188, Benchmark Homes, 7-12-07
Inspection result: Inspected OK for Good Cents
Notes: Repair insulation in the upstair closet at the bottom.
WFOB93615 / 001 City of College Station
PAGE 1
REQ. DATE: 04/30/07 04/30/07 10:27:31
LOCATION: 3856 OLDENBURG LN LOC ID: 208038
REQUESTOR: BENCHMARK - DBA G D T INC ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP TWO - 3/4" WTR TAPS.
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/30/07 SCHED COMPLETION: 04/30/07
********************************************************************************
JOB ORDER RESULT COMIEIQTS
BUILDING PERMIT
CITY OF COLLEGE STATION
--. 1101 TE.XA,<�: AVE
COLLEGE STA''I.3N, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00001314
430820
3856 OLDENBURG LN
244000-1224-0070
Date 4/30/07
RESIDENTIAL, 2 UNITS NEW (DUPLEX)
EDELWEISS ESTATES PHS 12
RESIDENTIAL
DUPLEX RESIDENTIAL
203016
Owner
Contractor
------------------------
------------------------
T D T HOMES/DBA G
D T INC
1110 12TH MAN CIR
COLLEGE STATION
TX 77845
(979) 690-7117
--- Structure Information
000 000 SINGLE FAMILY/DUPLEX
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
TYPE OF GARAGE (ATT/DET)
NA
HEATED AREA
3076.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
6.00
NUMBER OF BEDROOMS
6.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
KW
Permit pin number
499244
Permit Fee . . . .
772.00 Plan Check Fee
.00
Issue Date . . . .
4/30/07 Valuation . . .
. 203016
Expiration Date . .
10/27/07
Qty Unit Charge
Per
Extension
BASE FEE
460.00
104.00 3.0000
THOU BLDG, VAL 100001-500000
312.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
INTERRUPTERS)
BE PROTECTED BY AN ARC -FAULT CIRCUIT
------------------
BUILDING I
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
• 1101 TEXA$.AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00001314 Date 4/30/07
Application pin number . . . 430820
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
1 HOUR DUPLEX SEPERATION WALL MUST BE MAINTAINED FROM FLOOR
TO ROOF DECKING. ALL PENETRATIONS MUST BE PROPERLY
ADDRESSED AND MAINTAINED.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER LIC ODE SECTION
---�----
E-----------
BUILDING DEPT PRESENTATIV
t �lI
APPLI
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXA.& AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00001314 Date 4/30/07
Application pin number . . . 430820
----------------------------------------------------------------------------
Special Notes and Comments
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
BUILDING DEPT R PRESENTATIVE:
APPLICANT: p
BUILDING PERMIT
CITY OF COLLEGE STATION
1101, TEXAS- AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00001314 Date
4/30/07
Application pin number . . . 430820
----------------------------------------------------------------------------
Special Notes and Comments
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow Wall Bracing Fully Sheathed
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
800.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total 772.00 772.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 1150.00 1150.00 .00
.00
Grand Total 1922.00 1922.00 .00
.00
-
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101, TEXAS- AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00001190
Date 4/30/07
Application pin number . . .
570830
Property Address . . . . . .
3856 OLDENBURG LN
Property ID:
244000-1224-0070
Application type description
TEMP POLE
Subdivision Name . . . . . .
EDELWEISS ESTATES PHS 12
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
DUPLEX RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
------------------------
BENCHMARK - DBA G
D T INC
1110 12TH MAN CIR
COLLEGE STATION
TX 77845
(979) 690-7117
----------------------------------------------------------------------------
Permit TEMP POLE
PERMIT
Additional desc KW
Permit pin number 499251
Permit Fee . . . . 20.00
Issue Date . . . . 4/30/07
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
--------------------------------------- --- - --------------------------
BUILDING DEPT RE ESENT TIV
APPLICANT: _ r--� ,�- _
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE '
40e/r� COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764.3496 FAX
Planning b Development Servicer
WWW.CSTX.GOV
ZUrdKrty
DATE: TRCCREGi.�
APPLICATION # D1 4
TEMP POLE #
ADDRESS/LOCATION: 3 �J $ 5 Q N �j U Q LAN ✓
LOT __BLOCK _ SUBDIVISION (w6=1'SS GA C./JS SEC/PH 1_
BUSINESS/OWNER NAME: GAT XtUL PHONE 979-6TQ-76
CONTRACTOR/HOMEOWNER: C6.0i Fj pwgArs POE: Z.-5./7 /
CONTRACTOR ADDRESS: III Q lZ-i" WA( N U2 t
ELECTRICIAN: <1k = �Tc��-e j C,_ PLUMBER: q A ��Ur�lbiNg
HVAC: i 2 GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE
ADDITION
DEMOLITION (Asbestos Survey)
DUPLEX (Landscape Plans
Required)
DESCRIPTION OF WORK:
STRUCTURE USE:
LOCATION RE -ROOF
MOVING SHELL ONLY
NEW CONSTRUCTION " SLAB ONLY
REMODEURENOVATION" SWIMMING POOL
Re;
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN.REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ TOTAL AREA: 12-114 HEATED AREA: 307(0
(C t of L b; rind M'terials)
LN PUBLIC SEWER 2v?'7 O1 NUMBER OF BEDROOMS: �p
SEPTIC/TREATMENT SYSTEM
SEWER TAP: 4)
SIZE
WATER TAP:
SIZE
OTHER TAP:
SIZE
® TEMP POLE
GARAGE TYPE
P�Dtj b
SINGLE F]
ATTACH
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE a TRIPLE
Ski �OGV`
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
30-03
/ Plans Examiner
I 100ka v w 1
Zoning Official
C ents:
ES or NO
N C,
,l r
Energy Code Compliance Information
% Glazing of exterior walls 13 /a
Insulation'R valuo of exterior walls �" 13
Insulation R value of ceiling 1 (flat areas)' 3
Insulation R value of ceiling 2 (vaulted areas/no attic
)
Glazing SHGC 34
Glazing U-Factor
R value of ductwork t� l
A/C SEER Rating �. l
/ +A
e
7
SYMBOL
COMMON NAME (SCIENTIFIC NAME)
DESCRIPTION
OTY.
VALUE
POINTS
LIVE OAK (QUERCUS VIRGINIA)
CANOPY TREES > 2.1' TO 3.4' CAL.
!
150
f 5
5&04-c %*pia
to
%bo
t 0
SOD GRASS
TOTAL POINTS
Aso
N 49"2R'37' W
� +► C gA �+o►v SK J ��u.. \
SAua-L—U�-R b64oez C�D C&N
b� 'IIG9
7
SITE/LANDSCAPING PLAN
2x6 FIREBLOCKING @
10' O.C. MAX
2x6 STUDS @ 16110.C.
TO PROVIDE VERTICAL
FIREBLOCKING
ii�ii"--OUTLETS TO BE
BY FIREBLOCKING PERATED
moll- -
"X" GYP BD BOTH SIDES
`i •
1 BATT INSULATION
NOTE: TENANT SEPARATION SHALL
EXTEND TO BOTTOM OF ROOF DECK
I! �
REScheck Software Version 4.0.1
Compliance Certificate
Project Title: GDT Inc Job 295
Report Date: 04/25/07
Data filename: C:Trogram Files\Check\REScheck\REScheck docs\295BM.rck
Energy Code: 2003 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 13%
Heating Degree Days: 1788
Construction Site: Owner/Agent:
3856 Oldenburg Lane Glenn Thomas
College Station, , TX 77845 GDT Inc.
1110 12th Man Court
College Station„ TX 77845
979 69'0 7117
benchmarkhomesbcs@hotmail.com
Designer/Contractor:
Glenn Thomas
GDT Inc.
1110 12th Man Court
College Station„ TX 77845
979 690 7117
benchmarkhomesbcs@hotmail.com
Ccmprirance�Passes�16-10 E 'Maximum 0A 11176MYour:Home,UA!640 - 45:6%'BetterJTKiln Cod6'(UA)'t
Maximum SHGC: 0.40 Your SHGC: 0.34
Ceiling 1: Flat Ceiling or Scissor Truss:
2876 30.0
0.0 101
Wall 1: Wood Frame, 16" o.c.:
2567 13.0
0.0 182
Window 1: Metal Frame:Double Pane with Low-E:
308
0.570 176
SHGC: 0.34
Door 1: Glass:
20
0.630 13
SHGC: 0.34
Door 2: Solid:
18
0.630 11
Floor 1: Slab-On-Grade:Unheated:
151
0.0 157
Insulation depth: 0.0'
Heat Pump 1: Air Source: 12 HSPF, 14 SEER
Air Conditioner 1: Electric Central Air: 14 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
RES/chj/e''ck Versionn 4.0.1 and to comply with the mandatory requireme s listed i th"EScheck Inspection Checklist.
Ar, o /
Name - Title Signature Date F,
Project Notes:
Three Bedroom, Three Bath Duplex
GDT Inc Job 295 Page 1 of 4
REScheck Software Version 4.0.1
Inspection Checklist
Date: 04/25/07
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.570
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Glass, U-factor: 0.630
Comments:
❑ Door 2: Solid, U-factor: 0.630
Comments:
Floors:
❑ Floor 1: Slab -On -Grade: Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Heat Pump 1: Air Source: 12 HSPF, 14 SEER or higher
Make and Model Number:
❑ Air Conditioner 1: Electric Central Air: 14 SEER or higher
Make and Model Number:
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in
accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13.
Materials identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
GDT Inc Job 295 Page 2 of 4
Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency are clearly marked on the building plans or
specifications.
Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-value without compressing the insulation.
Duct Insulation:
Lj Supply ducts in unconditioned attics or outside the building are insulated to R-8.
Return ducts in unconditioned attics or outside the building are insulated to R-4.
Supply ducts in unconditioned spaces are insulated to R-6.
Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in
basements.
❑ Where exterior walls are used as plenums, the wall is insulated to R-8.
Duct Construction:
Ll Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened.
All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric,
or tapes. Tapes and mastics are rated UL 181A or UL 181 B.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
rl The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
Ej HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
GDT Inc Job 295 Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and
Runouts
Heated Water
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
Temperature (°F)
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Piping System Types
Fluid Temp.
Range(°F)
2" Runouts 1" and Less
1.25" to 2.0"
2.5" to 4"
Heating Systems
Low Pressurerremperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
GDT Inc Job 295 Page 4 of 4
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# O /
DATE:
"7
BUILDING ADDRESS: /
I. Foundation Requirements- Minimum City Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
N
1. One -hour rated extending to roof deck
NA/
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing plan or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
;i
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
&kOK
K
A. Stairway Details
NA/
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1 /2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical Ian to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
.i
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N K
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
Does not block any water course or divert any flow
Elevation certificate needed
t,50K
"APPROVED PLANS PER IRC SECTION R106.3.1."
LANS EXAMINER