Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2007-01289, 07-1291
o�— i2ss�on PREPARED 8/10/07, 12:01:59 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/10/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 4115 MCFARLAND DR SUBDIV: SOUTHERN TRACE PH 2 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 579530-0206-0080 APPL NUMBER: 07-00001289 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 6/07/07 JGM BLDG, FRAMING TIME: 17:00 6/07/07 AE June 7, 2007 10:59:46 AM acarter. 06/07/2007 04:44 PM JGM PDA need tempered glass in stairway, add nails to exterior sheathing B130 01 6/08/07 JGM BLDG, INSULATION TIME: 17:00 6/08/07 AP June 8, 2007 11:49:53 AM kwolfe. B130 02 6/11/07 OC BLDG, INSULATION TIME: 17:00 6/11/07 CA June 11, 2007 10:06:26 AM acarter. 06/11/2007 04:27 PM OC PDA this inspection already done per john m. 32 '01 6/12/07 JGM BLDG, SHEETROCK FASTENER TIME: 17:00 6/13/07 AP June 12, 2007 4:55:23 PM acarter. 125 01 8/09/07 RH BLDG, FINAL TIME: 17:00 8/09/07 DP August 8, 2007 3:05:25 PM kwolfe. 08/09/2007 12:06 PM RH PDA Need temp glass at stairs. Missing plug covers. Need to replace -damaged meter can. B125 02 8/10/07 BI BLDG, FINAL TIME: 17:00 9-/3-d7 ugust 10, 2007 12:01:22 PM glsouth. -------------------------------------- COMMENTS AND NOTES ---------------------------------- . 0, (� �-e- ("S Puy jp� A7WVti5 � 'f--e,V _ (8/14/2007) Kim Wolfe Re Calling for CO @4115 McrarlandlDr Page 1 From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 8/10/2007 8:39 AM Subject: Re: Calling for CO @ 4115 McFarland Dr All ok. Paul >>> Kim Wolfe 8/9/2007 8:11 AM >>> any issues? BP # 07-1289 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979)764-3570 www.cstx.gov Date: 8/10/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1289 Address: 4115 MCFARLAND DR Insp. Inspection Type Code Description Statu s Inspection Result Comments B115 BLDG, FRAMING IC 06/07/2007 04:44 PM JGM PDA 13115 BLDG, FRAMING IC need tempered glass in stairway, add nails to exterior 6115 BLDG, FRAMING IC sheathing B125 BLDG, FINAL IC 08/09/2007 12:06 PM RH PDA B125 BLDG, FINAL IC Need temp glass at stairs. Missing plug covers. Need to B125 BLDG, FINAL IC replace damaged meter can. B130 BLDG, INSULATION IC 06/11/2007 04:27 PM OC PDA B130 BLDG, INSULATION IC this inspection already done per john m. M100 MECH, ROUGH IN IC 06/06/2007 03:08 PM JGM PDA M100 MECH, ROUGH IN IC need to tighten ducts too much slack in runs M110 MECH, FINAL IC 08/09/2007 12:04 PM RH PDA M110 MECH, FINAL IC Need min. 30" of platform in front of furnace. Page 1 WF0893313 / 001 City of College' Station PAGE 1 REQ. DATE: 04/27/07 04/27/07 14:07:07 LOCATION: 4115 MCFARLAND DR LOC ID: 208498 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/27/07 SCHED COMPLETION: 04/27/07 ******************************************************************************** JOB ORDER RESULT COM ENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 8/14/07 Parcel Number . . . . . 579530-0206-0080 Property Address 4115 MCFARLAND DR COLLEGE STATION TX 77845 Subdivision Name SOUTHERN TRACE PH 2 Legal Description . . . Property Zoning . . . . SINGLE FAMILY RESIDENTIAL Owner Contractor . . . . . . STYLECRAFT BUILDERS 979 690-1222 Application number 07-00001289 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . JtA o t, /& Approved . . . . . . . Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF COLLEGE STATION 110t1 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner ------------------------ --------------------- Structure Construction Type . . . . . Occupancy Type . . . . . . Other struct info . . . . . 07-00001289 Date 4/27/07 723935 4115 MCFARLAND DR 579530-0206-0080 RESIDENTIAL, 1 UNIT DETACHED NEW SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 101574 Contractor ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 Information 000 000 ---------------------- COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1710.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 498139 Permit Fee . . . . 466.00 Plan Check Fee .00 Issue Date . . . . 4/27/07 Valuation . . . . 101574 Expiration Date . . 10/24/07 Qty Unit Charge Per Extension BASE FEE 460.00 2.00 3.0000 THOU BLDG, VAL 100001-500000 6.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) --------------------------------------------------Z__ - - ----------- BUILDING DEPT REPRESENTA�VE: �C-11 APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 110,1 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00001289 Date 4/27/07 Application pin number . . . 723935 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alterna -----ive, R-6 duct ---------------------------------------------------------- BUILDING DEPT REPRES��E: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 110,1 TEYAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001289 Application pin number . . . 723935 Page 3 Date 4/27/07 Special Notes and Comments insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Other Fees SEWER TAP 4" WATER TAP 3/4" Fee summary Charged Paid BUILDING DEPT REPRESENT APPLICANT: 350.00 400.00 Credited _ Due ----�-- vim - ----------- BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Permit Fee Total 466.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1216.00 07-00001289 723935 466.00 .00 750.00 1216.00 .00 .00 .00 .00 Page 4 Date 4/27/07 .00 .00 .00 .00 ------------------------------------------------ -- - ---------- BUILDING DEPT REPRES TAT 1}: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00001291 926765 4115 MCFARLAND DR 579530-0206-0080 Date 4/27/07 TEMP POLE SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit pin number . 498147 Permit Fee . . . . 20.00 Issue Date . . . . 4/27/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------- Fee summary Charged ---------- ----------------------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - ------------------------------------------------�-- - ----------- BUILDING DEPT REPRESENTIV APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning crDevelnpmenrServices WWW CSTX.GOV For Office Use Only DATE: —1'V� V('��Tc�L RCC REEGC APPLICATION # r -14 6 TEMP POLE # 01 - I " l ADDRESS/LOCATION: // 41I5 MCP^Q-ANn l>( LOT 5 BLOCK b / SUBDIVISION SOUTHERN TRACE SEC/PH 2 BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: To Be Determined PLUMBER: Bass Plumbing HVAC: To Be Determined GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing Less Slab STRUCTURE USE: Single Family Residence WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS ❑ ENGINEERED QX HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N/A TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $—�101;574 Less Slab TOTAL AREA: 1949 HEATED AREA: 1710 (Cost of Labor and Materials) X PUBLIC SEWER NUMBER OF BEDROOMS: 4 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 4 SEWER TAP: 4" SIZE WATER TAP: %11 SIZE ❑ OTHER TAP: SIZE TEMP POLE GARAGE TYPE: (> VV SINGLE ATTACHED 71 INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: DOUBLE E] SIGNATURE OF APPLICANT: *If proposed work involves new commercial const uctio commercial property, building elevations are required. /J Official Use I z s -01 Composition TRIPLE AR,PORT ylyl01 For Stvlecraft e inip roveme jets/renovations to an existing Plans Examiner Zoning Official / '01 C nts: or NO Energy Code Compliance Information % Glazing of exterior walls 12 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER Rating 13 COLLUGE STAIIO PLAN REVIEW _.,_,;,-ONE-and-TRIO-FAMIL-Y-OECtiPANCY-•REQUIREMENTS". CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: BUILDING ADDRESS: s � ! 1 • 1;.-Foundation Re ulrements=.Wnlmum City. Foundation Standards - A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated 11. Framing: Floor, Wall, Ceiling and Roof Requirements A/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck MNOK E. Header sizes indicated on plans q/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist sizespacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter sizespacing roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tem"ered Glass required in all hazardous locations PLAN REVIEW w.. _ONE-and.TWO.FAMILY.,OCC-UPANCY-REQiJIREMENT�- CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Re uiremeritsA. OK K Stairway Details N 1. Maximum riser height 7-3/4 inches. 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements JlQ0K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW _w::�.-,.....:.,ONE:.arad�TaA/Q•FAMtL�F �OCCtiRAY=REfi�t1tREMENTS=;,�=��.;p.�:�,��--•�-.-��;. CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure- reducing valve required when water pressure exceeds 80 psi N Plum bingl access to bathtubs C. Means for thermal expansion provided when required D._.Water. heaters-elevated-18"-when installed in --the garage -or -room -,directly- off garage- - - VII. Mechanical Requirements NAI A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements NA/ A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for comer lots Subdivision Regulations — Ordinance 690 NQCW Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." .j/. PLANS EXAMINER DATE REScheck Software Version 4.0.1 Compliance Certificate Project Title: 1690 Plan Report Date: 03/16/07 Data filename: \\STYLECRAFTI\Share\ACAD\RESCheck\1690.00-Master.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: College Station, TX 77845 Stylecraft Builders, Inc. Stylecraft Builders, Inc. 4090 SH 6 South 4090 SH 6 South College Station, TX 77845 College Station, TX 77845 979-690-1222 x120 979-690-1222 x120 ewivagg@stylecraft-builders.com ewivagg@stylecraft-builders.com Maximum SHGC: 0.40 Your SHGC: 0.40 vvan is vvooa rrame, lb" o.c.: 1136 13.0 0.0 79 Window 1: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 2: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 3: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 4: Metal Frame: Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 5: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 6: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 7: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 8: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 9: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 10 Twin: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 10 Twin: Metal Frame: Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Door 1: Solid: 20 0.500 10 Door 2: Glass: 18 0.440 8 SHGC: 0.40 Wall 2: Wood Frame, 16" o.c.: 981 13.0 0.0 73 Window 11: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 12: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 13: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 14: Metal Frame:Double Pane with Low-E: 13 0.670 9 1690 Plan Page 1 of 2 SHGC: 0.40 Window 15: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 16: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 17: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 18: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 19: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 20: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 21: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 22: Metal Frame: Double Pane with Low-E: SHGC: 0.40 Window 23 Twin: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 23 Twin: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Flat Ceiling or Scissor Truss: Floor 1: Slab -On -Grade: Unheated: Insulation depth: 0.0' Floor 2: All -Wood Joist/Truss:Over Unconditioned Space: Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER 3 0.670 2 4 0.670 3 13 0.670 9 3 0.670 2 4 0.670 3 4 0.670 3 4 0.670 3 6 0.670 4 13 0.670 9 13 0.670 9 25 19.0 0.0 1 867 19.0 0.0 44 869 0.0 905 24 13.0 0.0 2 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requirements ' in the RESchec Inspection Checklist. ' TY4E2-'0A1=7- - '71 o� Name - Title Signature Date Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 1690 Plan Page 2 of 2 FINISHING NOTES S More Home, Less Money SHEET INDEX COVER SHEET G-1 GENERAL NOTES G-2 SITE PLAN C-1 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 DETAILS S-3 BRACING PLAN S-4 FRAMING PLAN S-5 ROOF FRAMING PLAN S-6 DECKING LAYOUT S-7 ELEVATIONS S-8 FRAMING DETAILS S-9 ELECTRICAL PLAN E-1 FLOOR PLAN A-1 .FLOORING PLAN A-2 CABINET LAYOUT A-3 PLAN APPROVAL APPROVED INITIALS DATE ADMINISTRATOR / SUPERINTENDENT / CUSTOMER / NOTICE THIS SET OF DRAWINGS FOR A HOME IS THE COPYRIGHTED PROPERTY OF STYLECRAFT BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL OR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF THE DESIGNERS. BUILDING FOOTPRINT 9'�P 26'b' c 44'40' 1 ST PLAN PREVIEW SCALE:3/32'=l'-0' CFRONT ELEVATION SCALE:3/32'=,'-0' r-------------------------i I I I I I I L------------� 2ND PLAN PREVIEW SCALE:3/32'=l'-0' 1 INotes COMMENTS I A r� Z G-1 :OVER SHEEP i l�J I �n 1p�'' rn 35'-7 " i o; i --- �- - -- .a r C C o H �x00 d NIr ' " IC ' . m I V � c�o BURKE/KAUFMAN: 4115 MCFARLAND :ST07010 PLAN# S-1711-C STYLECRAFT BUILDERS, INC. ©2007 4090 ST. HWY. 6 SOUTH COLLEGE STATION, TEXAS 77845 (979) 690-1222 y O