Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2007-01280
i;L***no�- R752U3 10',&PA WFO893308 / 001 City of Collage Station PAGE 1 REQ. DATE: 04/27/07 In 04/27/07 14:01:20 LOCATION: 4103 MCFARLAND DR LOC ID: 208486 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/27/07 SCHED COMPLETION: 04/27/07 JOB ORDER RESULT COMENTS -- n PRE -CON I CORRECTED FINAL aim xas oo�c-noN ornmseoocun�.n 7�7 g;� XISTI�U FAN E - - - - T _ 5' SIDE SETBACK_ " — :------ --------------Cn.0.No'-7'' i . T i N c/) I � ZI I bo �I cnl� Cm IN o p I r I m I> DMI I ID pptil w Io yT1 -------- --- � I I I T I Jp'�i � 20'41" III I ♦V — — - -- uy -- - — 00 >O4aw �xN[�Ljn za �r z �d d SPEC: 4103 MCFARLAND :ST07004 PLAN# S-1711-A 9 STYLECRAFT ' BUILDERS, INC. ©2007 MLI Ul 4090 ST. HWY. 6 SOUTH COLLEGE STATION, TEXAS 77845 (979) 690-1222 y zz cn a ay More Home, Less Money SHEET INDEX COVER SHEET G-1 GENERAL NOTES G-2 SITE PLAN C-1 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 DETAILS S-3 BRACING PLAN S-4 FRAMING PLAN S-5 ROOF FRAMING PLAN S-6 DECKING LAYOUT S-7 ELEVATIONS S-8 FRAMING DETAILS S-9 ELECTRICAL PLAN E-1 FLOOR PLAN A-1 FLOORING PLAN A-2 CABINET LAYOUT A-3 PLAN APPROVAL APPROVED INITIALS I DATE ADMINISTRATOR / SUPERINTENDENT / CUSTOMER / NOTICE THIS SET OF DRAWINGS FOR A HOME IS THE COPYRIGHTED PROPERTY OF STYLECRAFT BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL wR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF THE DESIGNERS. © © PORCH 9-0' STORAGE 14'a• x 9'x ms x r-r DINING 9x 1a-1' x 8'S LIVING I"aa I 9`0 Ig • I WT x 15< KITCHEN 1a-r x 1o'br AFEN O _ I I� ,.v FOYER x 17-11' BEDROOM 1 abr 178' x 12' W PORCH a0 14'.T x r-9' BUILDING FOOTPRINT 9� 26'S x 44'-10' 1 ST PLAN PREVIEW SCALE:3/32"=1'-0" IF-------------------------- I I I I I I I I 1 I I I I L------------� 2ND PLAN PREVIEW SCALE:3/32"=V-0" FMSHING NOTES 1 Notes COMMENTS VA ILOCATION I U� vi /w o a F. �D W Pa o U 040 U Cif �v (qj G-1 COVER SHEET DI AFRONT ELEVATION SCALE:3/32"=1'-0" PREPARED 7/25/07, 8:02:46 INSPECTION TICKET PAGE 30 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/24/07 - - - - - - - - - - - - - - - - - - - - - - - - - 7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ADDRESS . : 4103 MCFARLAND DR SUBDIV: SOUTHERN TRACE PH 2 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 579530-0206-0020 APPL NUMBER: 07-00001280 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 6/04/07 JGM BLDG, FRAMING TIME: 17:00 6/04/07 AE June 1, 2007 9:26:48 AM acarter. 06/04/2007 10:32 AM JGM PDA need double joist hangers at attic access and single at return air B130 01 6/05/07 JGM BLDG, INSULATION TIME: 17:00 6/05/07 AP June 5, 2007 10:09:34 AM glsouth. B132 01 6/07/07 JGM BLDG, SHEETROCK FASTENER TIME: 17:00 6/07/07 AP June 7, 2007 11:05:53 AM kwolfe. B125 01 7 24/07 BI BLDG, FINAL TIME: 17:00 July 24, 2007 4:28:09 PM acarter. ------------------------/------- CONTINUED ONTO NEXT PAGE W1- Amber Carter - Re: Calling for C.O. @ 41103 McFarland Dr 1 From: Mitchell Carson To: Amber Carter; Benjamin McCarty; Chris Haver; Date: 7/25/2007 3:56 pm Subject: Re: Calling for C.O. @ 4103 McFarland Dr. THIS ONE IS OK MUCH >>> Gina Southerland 07/25/07 8:29 AM >>> BP# 07-1280 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.gov BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001280 Date 4/27/07 Application pin number . . . 811200 Property Address . . . . . . 4103 MCFARLAND DR Property ID: 579530-0206-0020 R #• Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SOUTHERN TRACE PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 101574 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1710.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 498014 Permit Fee . . . . 466.00 Plan Check Fee .00 Issue Date . . . . 4/27/07 Valuation . . . . 101574 Expiration Date . . 10/24/07 Qty Unit Charge Per Extension BASE FEE 460.00 2.00 3.0000 THOU BLDG, VAL 100001-500000 6.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) -------------------------------------------- -----�-- ---.--------------- BUILDING DEPT REPRES TIV : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 07-00001280 Date 4/27/07 Application pin number . . . 811200 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI,Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. --------------------------------------------- --------- - DEPT REP ENTATIVE: APPLICANT: ( F� Sr BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00001280 Date 4/27/07 Application pin number . . . 811200 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 466.00 466.00 .00 .00 BUILDING DEPT REPRESE IVE: �Lj A A - APPLICANT: �� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . Application pin number Plan Check Total Other Fee Total Grand Total . . . . 07-00001280 . . . 811200 .00 .00 750.00 750.00 1216.00 1216.00 BUILDING DEPT REPRE TIVE: APPLICANT: Page 4 Date 4/27/07 .00 .00 .00 .00 .00 .00 TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00001281 912615 4103 MCFARLAND DR 579530-0206-0020 Date 4/27/07 TEMP POLE SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc KW Permit pin number 498022 Permit Fee . . . . 20.00 Issue.Date . . . . 4/27/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------- ----- - --- - -------------- BUILDING DEPT REPRESENTAT-- APPLICANT: r APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning& Development Services WWW CSTX.GOV I l For Office Use Only DATE: _)5��IDIRCC RREG APPLICATION # cn TEMP POLE #' ADDRESS/LOCATION: g1QF3 &T--AiZ LAN T2 D( '"" LOT Z /BLOCK ____� V/SUBDIVISION SOUTHERN TRACE SEC/PH 2 BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: To Be Determined PLUMBER: Bass Plumbing HVAC: To Be Determined GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing Less Slab STRUCTURE USE: Single Family Residence WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS ❑ ENGINEERED �X HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N/A TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $�101,57471:ess Slab—i e�TTOTAL AREA: 1949 HEATED AREA: 1710 (Cost of Labor and Materials) APUBLIC SEWER NUMBER OF BEDROOMS: 4 ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 4 LN SEWER TAP WATER TAP OTHER TAP: TEMP POLE 4" SIZE %11 SIZE SIZE �,t •(6\ GARAGE TYPE: SINGLE AATTACHED V INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: FOUNDATION TYPE Siding and/or Masonry Slab on Grade ROOF TYPE: Composition DOUBLE [::] TRIPLE RT SIGNATURE OF APPLICANT: /-/ LIMOLIM07 For St lecraft *If proposed work involves new commercial constructio facade i proveme is/renovations to an existing commercial property, building elevations are required. Official Use Only 7a q- Z S- o-7 ekS NO NO Plans Examiner Zoning Official „' f �I�QGIj V''-L'— 4 Energy Code Compliance Information % Glazing of exterior walls 12 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER Rating 13 CO LLLGE %TA110N PLAN REVIEW ._..ONE-and.-TVVO-FAQ IL-YOECUPA-NCY-REQdIREMEt4isS, CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER#]: Q!, DATE: 2 j� BUILDING ADDRESS: O I Foundation Requirements.!. Minimum.Ci-Foundatiion Standards A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior,,-24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fire lace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements q/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans q/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size s acin" rade grid direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter sizespacing, roof slope & pudin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q.-Tem " tired Glass require in all hazardous locations I ,t PLAN REVIEW _..._.., ONEand-TWO.-FAMILY'OCCUP-AN -REQUIREMENT� CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only OM S. All walls within 3' of property line to have protected openings. K III.- Stairwav-Reauirements -- - ------_--._- -- - -----.--..__.-_._._. _ . -.-- Stairway Details 1: Maximum riser height-7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform (3/8" Max. difference) 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight (6-8) B. Winder details 1. Treads a minimum of six .(6) inches on. narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half (9-1/2) inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six (6-6) inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements MOK A. Hearth extensions '17- 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: lee 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location R PLAN REVIEW ONE and TWO FAMILY-OCCUP NAY --REQUIREMENTS-- == CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure- reducing valve required when water pressure exceeds 80 psi N - - . Plumbing access to bathtubs C. Means for thermal expansion provided when required _D.. _Water heaters elevated 18" where -installed -in -the- garage-or.-room-directl off garage - VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided - - - 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vlll. Energy Requirements NA/ A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for comer lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed TO _K "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER DATE REScheck Software Version 4.0.1 Compliance Certificate Project Title: 1690 Plan Report Date: 03/16/07 Data filename: \\STYLECRAFTI\Share\ACAD\RESCheck\1690.00-Master.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: College Station, TX 77845 Stylecraft Builders, Inc. Stylecraft Builders, Inc. 4090 SH 6 South 4090 SH 6 South College Station, TX 77845 College Station, TX 77845 979-690-1222 x120 979-690-1222 x120 ewivagg@stylecraft-builders.com ewivagg@stylecraft-builders.com ' Maximum SHGC: 0.40 Your SHGC: 0.40 vvan i. vvuuu rrame, -io- o.c.: 1136 13.0 0.0 79 Window 1: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 2: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 3: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 4: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 5: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 6: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 7: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 8: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 9: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 10 Twin: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 10 Twin: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Door 1: Solid: 20 0.500 10 Door 2: Glass: 18 0.440 8 SHGC: 0.40 Wall 2: Wood Frame, 16" o.c.: 981 13.0 0.0 73 Window 11: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 12: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 13: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 14: Metal Frame:Double Pane with Low-E: 13 0.670 9 1690 Plan Page 1 of 2 SHGC: 0.40 Window 15: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 16: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 17: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 18: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 19: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 20: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 21: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 22: Metal Frame: Double Pane with Low-E: 6 0.670 4 SHGC: 0.40 Window 23 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 23 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: 25 19.0 0.0 1 Ceiling 2: Flat Ceiling or Scissor Truss: 867 19.0 0.0 44 Floor 1: Slab -On -Grade: Unheated: 869 0.0 905 Insulation depth: 0.0' Floor 2: All -Wood JoistlTruss:Over Unconditioned Space: 24 13.0 0.0 2 Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requireme i ed in the REScheck Inspection Checklist. 5'rYG6744Ar=/— ( r -),/, I '_� — e o7 Name - Title Signat Date Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 1690 Plan Page 2 of 2