Loading...
HomeMy WebLinkAboutRES2007-01266, 07-1267m regol demF) t �- ___ ft A. . l WF0893346 / 001 City of Colleg, Station PAGE 1 REQ. DATE: 04/27/07 04/27/07 14:41:54 LOCATION: 2913 MCLAREN DR LOC ID: 208576 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/27/07 SCHED COMPLETION: 04/27/07 ******************************************************************************** JOB ORDER RESULT COMMENTS PREPARED 7/25/07, 8:02:46 INSPECTION TICKET PAGE 26 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/24/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 2913 MCLAREN DR SUBDIV: SOUTHERN TRACE PH 2 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 579530-0207-0110 APPL NUMBER: 07-00001266 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 6/06/07 JGM BLDG, FRAMING TIME: 17:00 6/06/07 AE June 6, 2007 9:25:16 AM acarter. 06/06/2007 03:06 PM JGM PDA need tempered glass in stairway by final B130 01 6/07/07 JGM BLDG, INSULATION TIME: 17:00 6/07/07 AP June 7, 2007 10:24:48 AM kwolfe. B132 01 6/08/07 JGM BLDG, SHEETROCK FASTENER TIME: 17:00 6/08/07 AP June 8, 2007 2:26:00 PM acarter. B125 01 7/24/07 BnI�, BLDG, FINAL TIME: 17:00 July 24, 2007 4:39:12 PM acarter. --------------------------------------- COMMENTS AND NOTES -------------------------------------- Amber Carter - Re: Calling for C.0. @ 2913 Mclaren Dr. „ 1 From: Mitchell Carson To: Amber Carter; Benjamin McCarty; Chris Haver; ... Date: 7/25/2007 3:54 pm Subject: Re: Calling for C.O. @ 2913 Mclaren Dr. NEED LID ON WATER METER BOX MITCH >>> Gina Southerland 07/25/07 8:28 AM >>> BP# 07-1266 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.gov Amber Carter - Re: Calling_for C O @ 2913 Mclaren Dr. 1 From: Terry Boriskie To: Amber Carter; banderson@stylecraft„buil... Date: 7/25/2007 4:40 pm Subject: Re: Calling for C.O. @ 2913 Mclaren Dr. Stylecraft Builders has been notified. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Mitchell Carson 7/25/2007 3:54 pm >>> NEED LID ON WATER METER BOX MITCH >>> Gina Southerland 07/25/07 8:28 AM >>> BP# 07-1266 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.00v SHEET INDEX COVER SHEET G-1 GENERAL NOTES G-2 SITE PLAN C-1 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 DETAILS S-3 BRACING PLAN S-4 FRAMING PLAN S-5 ROOF FRAMING PLAN S-6 DECKING LAYOUT S-7 ELEVATIONS S-8 FRAMING DETAILS S-9 ELECTRICAL PLAN E-1 FLOOR PLAN A-1 FLOORING PLAN A-2 CABINET LAYOUT A-3 AREA JY11[R [1FINISHING NOTES SUMMARY 1 Notes cn 0ONrl-W)( )cNLL, More Home, Less Money °° °° x °° M K F STORAGE PORCHiaOQrs9: r-r DINING rl ! BATH Q�0O00a g� U O 1a-r x as � Z U F-t 0 0 a BEDROOM 4 LOCATION 7-r- us x170' SUBDIV. ST LIVING w • 1 PHASE 02 g� I I BLOCK 07 14•.c . 1sr• I BEDROOM 3 KITCHEN 1a-1• ■ 104, 1 17s . 17-0• 4 ARg1E 1 � ar LOFT N FOYER F- BEDROOM1O a s� "� N: 13'-11O 7p w� BEDROOM 17E• c 170 a ra 17E• x17-T r 1 ��j v I4 n 1 i PORCH of L 4'a z r-s BUILDING FOOTPRINT I ^ W O zaa•9z4a'-1r L___________—� � COMMENTS r to U N QxrA a W� 1 ST PLAN PREVIEW ND PLAN PREVIEW Z a SCALE:3/32•=1'-0' 2SCALE:3/32"=1'-0• O o TICE � THIS SET OF DRAWINGS FOR A HOME IS THE COPYRIGHTED PROPERTY OF STYLECRAFf BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL OR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, ® ® ® M� DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER QZ WITHOUT THE WRITTEN PERMISSION OF THE ® - Q E DESIGNERS. OO aO h•r•� a 00 a 00 x �` w ae as SHEET: CFRONT ELEVATION G- I SCALE:3/32"=1'-W COVER SHEET PLAN APPROVAL APPROVED INITIALS DATE ADMINISTRATOR / SUPERINTENDENT / CUSTOMER / W. a � ®rzr z4o, I. 36'-11" T MUYSHONDT: 2913 MCLAREN : ST07024 PLAN# S-1711-C FINAL M STYLECRAFT BUILDERS, INC. ©2007 nm"rsnxveo. uraooucnox o""�eo°N"mom ,i 4090 ST. HWY. 6 SOUTH COLLEGE STATION, TEXAS 77845 (979) 690-1222 J e BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE tSTAT-ION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R 4. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00001266 391390 2913 MCLAREN DR 579530-0207-0110 Date 4/26/07 RESIDENTIAL, 1 UNIT DETACHED NEW SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 101574 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1710.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc KW Permit pin number 497867 Permit Fee . . . . 466.00 Plan Check Fee .00 Issue Date . . . . 4/26/07 Valuation . . . . 101574 Expiration Date . . 10/23/07 Qty Unit Charge Per Extension BASE FEE 460.00 2.00 3.0000 THOU BLDG, VAL 100001-500000 6.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT --------INTERRUPTERS) - ---------------------------- - ---------- BUILDING DEPT REPRESENT��VE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE ,STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001266 Application pin number . . . 391390 Page 2 Date 4/26/07 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT -AIR - - ----L KAGE _ ---------------------------------------------�---------- BUILDING DEPT REPRESENT&TI-VE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE,STATYON, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00001266 Date 4/26/07 Application pin number . . . 391390 ---------------------------------------------------------------------------- Special Notes and Comments For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 ----------------------------------------------------�---------- BUILDING DEPT REPRESENTIA'iIy-,-) APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE -STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00001266 Date 4/26/07 Application pin number . . . 391390 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited ---------- Due ---------- ----------------- Permit Fee Total 466.00 466.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1216.00 1216.00 .00 .00 ------------------- --- ---- -4-19� ----------- - j�A BUILDING DEPT REPRESE V.� APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE�STAT ON, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00001267 492805 2913 MCLAREN DR 579530-0207-0110 Date 4/26/07 TEMP POLE SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit pin number . 497875 Permit Fee . . . . 20.00 Issue Date . . . . 4/26/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------- Fee summary Charged ---------- ----------------------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------------------------------------`J•- - -- ------- BUILDING DEPT REPRES'I: APPLICANT: 1 APPLICATION FOR BUILDING PERMIT CITY OF•COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning& Development Services WWW CSTX.GOV I `For Office Use Only DATE: 0jS -07TRCC REG APPLICATION # TEMP POLE # ADDRESS/LOCATION: 2a 1`7 MGLAR-ClJ 1� LOT BLOCK _ 7 SUBDIVISION SOUTHERN TRACE SEC/PH 2 ' BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: To Be Determined PLUMBER: Bass Plumbing HVAC: To Be Determined GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* _ SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing Less Slab STRUCTURE USE: Single Family Residence WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS ❑ ENGINEERED QX HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N/A TEXAS ACCESSIBILITY STANDARD (TAS) PROJEC-T-kZEGISTRATION# EABPRJ N/A VALUATION: $ 101.574_Less.Slab TOTAL AREA: 1949 HEATED AREA: 1710 (Cost of Labor and Materials) FNr PUBLIC SEWER NUMBER OF BEDROOMS: 4 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 4 ® SEWER TAP: 4e SIZE WATER TAP: %11 SIZE OTHER TAP: SIZE TEMP POLE g� GARAGE TYPE: SINGLE ATTACHED INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE F__] TRIPLE ACH SIGNATURE OF APPLICANT: 1,— 14- / /r ` *If proposed work involves new commercial construction or%ade commercial property, building elevations are required. Official Use Only zs-10� Plans Examiner Zoning Official 1 Saks / l'1 aAc y 5 Siding and/or Masonry Slab on Grade Composition E] 09 novations to an existing Comments: ,S r NO I IL) ki Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating X 12% R13 R30 R19 .40 R6 13 A 2 A 4 COLUCL STAHON PLAN REVIEW -..-,,.,.ONE-and,T-WO--r-AMILl�--OGGUPA-N 0-Y-REQUIREMERTS-­ CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE* BUILDING ADDRESS: ^ CA-69" L Foundation Requirements -.Minimum. City. Foundation Standartla- -NN . K A. Concrete minimum compression strength of 3000 PSI B. Minimum four (4) inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier la out shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings (30" exterior, 24" interior, unless over 60' long must be 30") 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated VA1OK 11. Framin : Floor, Wall, Ceiling and Roof Requirements NA(M A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex N#OK 1. One -hour rated extending to roof deck AWO _K E. Header sizes indicated on plans N)WK) F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty (20) inch clear width by twentLfour (24) inch clear height b. Maximum sill height of forty-four (44) inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade ands acin I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing —j-.--Roof 2. Moisture barrier indicated on plans 3. Exterior Wall Covering framing plan or elevation shown K. Ceiling joist size,, spacing,"grade arid'direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing (if required to reduce span) O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Term piared'Glass required in all hazardous locations PLAN REVIEW ONE and.,T-WO-FAMII .Y-OCCUPAA C--Y-- E-QUIRE-MEN- ,— = - CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. 1t1:-Stairway Requirements MORK K A. Stairway Details N 1. Maximum riser height 7-3/4 inches. 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six (6).inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere _J IV. Fireplace Requirements JIQ0K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements,.-,::_ ..._ _ A. Electrical plan to include: NPUeg 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE -and, -TWO AMIL1� aCGURANC"Y-REOUIREMEt4T.S .' : CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure -reducing valve required when water pressure exceeds 80 psi- - Plum biri- access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed -in the- ara oo►n-directl -offgarage VII. Mechanical Requirements A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units -NAIM B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided - - 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NA/ A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements - Ordinance 850 N Permitted use for district ;r- Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for comer lots Subdivision Regulations - Ordinance 690 NAZOW Approved subdivision Plat filed Flood lain Regulations - Ordinance 1301 NAAW Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER DATE REScheck Software Version 4.0.1 Compliance Certificate Project Title: 1690 Plan Report Date: 03/16/07 Data filename: \\STYLECRAFT1\Share\ACAD\RESCheck\1690.00-Master.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 1788 Construction Site: Owner/Agent: College Station, TX 77845 Stylecraft Builders, Inc. 4090 SH 6 South College Station, TX 77845 979-690-1222 x120 ewivagg@stylecraft-builders.com Maximum SHGC: 0.40 Your SHGC: 0.40 Designer/Contractor: Stylecraft Builders, Inc. 4090 SH 6 South College Station, TX 77845 979-690-1222 x120 ewivagg@stylecraft-builders.com Wall 1: Wood Frame, 16" o.c.: 1136 13.0 0.0 79 Window 1: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 2: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 3: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 4: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 5: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 6: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 7: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 8: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 9: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 10 Twin: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 10 Twin: Metal Frame: Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Door 1: Solid: 20 0.500 10 Door 2: Glass: 18 0.440 8 SHGC: 0.40 Wall 2: Wood Frame, 16" o.c.: 981 13.0 0.0 73 Window 11: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 12: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 13: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 14: Metal Frame:Double Pane with Low-E: 13 0.670 9 1690 Plan Page 1 of 2 I t► SHGC: 0.40 ' Window 15: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 16: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 17: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 18: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 19: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 20: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 21: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 22: Metal Frame:Double Pane with Low-E: 6 0.670 4 SHGC: 0.40 Window 23 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 23 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: 25 19.0 0.0 1 Ceiling 2: Flat Ceiling or Scissor Truss: 867 19.0 0.0 44 Floor 1: Slab -On -Grade: Unheated: 869 0.0 905 Insulation depth: 0.0' Floor 2: All -Wood Joist/Truss:Over Unconditioned Space: 24 13.0 0.0 2 Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. ST'1l,E�A� �6 3 07 Name - Title Signature Date Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 1690 Plan Page 2 of 2