HomeMy WebLinkAboutRES2007-01262, 07-126307 Mw, R 752 1/3 PREPARED 7/30/07, 7:50:01 INSPECTION TICKET PAGE 14 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/27/07 ------------------------------------------------------------------------------------------------ ADDRESS 4102 MCLISTER DR SUBDIV: SOUTHERN TRACE PH 2 CONTRACTOR STYtECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 579530-0208-0020 APPL NUMBER: 07-00001262 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ----------------------- 7------------------------------------------------------------------------ B115 01 5/31/07 RH BLDG, FRAMING TIME: 17:00 5/31/07 DP May 31, 2007 11:26:53 AM kwolfe. 05/31/2007 03:54 PM RH PDA Nail upper floor bottom plates min. 1 " O.C. Nail osb 411 o.c. at edges in storage room. Block floor joist at storage room. Anchors at Back door. B115 02 6/01/07 RH BLDG, FRAMING TIME: 17:00 l 6/01/07 AP May 31, 2007 4:06:56 PM acarter. B130 01 6/04/07 JGM BLDG, INSULATION TIME: 17:00 6/05/07 AP June 4, 2007 9:17:23 AM glsouth. B132 01 6/11/07 OC BLDG, SHEETROCK FASTENER TIME: 17:00 6/11/07 AP June 11, 2007 8:02:20 AM glsouth. B125 01 7/27/07 Bb BLDG, FINAL TIME: 17:00 U3b/0.1 Tom• Or— July 27, 2007 12:29:04 PM acarter. ----------------------------------- CONTINUED ONTO NEXT PAGE----------------------------------- Date: 7/30/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1262 Address: 4102 MUSTER DR Type inspection Type Code status Inspection Result Comments Description B115 BLDG, FRAMING IC 05/31/2007 03:54 PM RH PDA B115 BLDG, FRAMING IC Nail upper floor bottom plates min. 1 " O.C. Nail osb 4" B115 BLDG, FRAMING IC o.c. at edges in storage room. Block floor joist at B115 BLDG, FRAMING IC storage room. Anchors at Back door. E150 ELEC, FINAL IC July 26, 2007 9:11:02 AM acarter. P125 PLBG, FINAL IC 07/25/2007 11:33 AM JGM PDA P125 PLBG, FINAL IC all electric Page 1 WF0893294 / 001 City of College Statipn PAGE REQ. DATE: 04/27/07 04/27/07 13:42:46 LOCATION: 4102 MCLISTER DR LOC ID: 208542 REQUESTOR: STYLECRAFT BUILDERS INC ORIGIN: CUSTOMER -WALK IN REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE: 4" SWR TAP 3/4" WTR TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/27/07 SCHED COMPLETION: 04/27/07 ******************************************************************************** JOB ORDER RESULT COM4=S (8/6/2007) Gina Southerland - Re: Calking for C O for 4102 McLister Page 1 From: Joe Garcia To: Amber Carter; banderson@stylecraft-builders.com; Benjamin McCarty; Ch... Date: 8/3/2007 3:54 PM Subject: Re: Calling for C.O. for 4102 McLister WATER METER BOX HAS BEEN REPLACED, AND SEWER BOX HAS BEEN BROUGHT TO GRADE. THIS ONE IS OK NOW. JMG >>> Terry Boriskie 08/01/07 12:14 PM >>> Stylecraft has been notified. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 7/31/2007 3:55 pm >>> Water box broken flagged. Sewer buried flagged. Paul >>> Amber Carter 7/30/2007 2:51 PM >>> by #07-1262 ,b-,bV 2fdLd lltiL[d 6S £ CI i VH-4vis Iv i o 3S 6b6i Q�d�� �d.i.o r� ONO ZZZI-069(6L6) Loozo Sb8LLSVXH.L`MOLLVLSHOH"I'IOD HJJlOS9'AMH'.LS060b 1 �D� sxaQ'IIng z�VxDa�Ass �waasmu�`o��aon"u'aaaa3uw�m'rv°" v.iie "I` NIJ w S 3S19 g HDNOd Q� HAO c� > Q w x C4 g- l I L j- S #I��'rld F Qa i �ax�io� dS 0 i L I i o i DV is 9ga V 1100 ° Z � � i-VOLOZS: NalSI'IDW ZOTt :NaD l-4 des 0 n w a�w Qu w a 00 N �xN�w U [-� v� o00 - - M �%W$p LJ,— 3QN3= DNf1SIX3 � -----------, _ _ MOVS13S 301S .9 -.- -- --- -.-- qp . .2 9 i ��co O� --- --`a ----------- I I I y U- I Y ply I tt1 W QI d ml I I Ij �� w H I IH wI I LL11 IZ O r� �I - J cq I p ^l R 06 5 cn W M ovei3sMIS --- ^ ---------�--- ��+ w JQ y zo r BUILDING PERMIT CITY OF COLLEGE STATION ; 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ----------------------------------------------------------'------------------ Application Number . . . . . 07-00001262 Date 4/26/07 Application pin number . . . 220958 Property Address . . . . . . 4102 MCLISTER DR Property ID: 579530-0208-0020 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SOUTHERN TRACE PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 101574 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1710.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 497602 Permit Fee . . . . 466.00 Plan Check Fee .00 Issue Date . . . . 4/26/07 Valuation . . . . 101574 Expiration Date . . 10/23/07 Qty Unit Charge Per Extension BASE FEE 460.00 2.00 3.0000 THOU BLDG, VAL 100001-500000 6.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN C-FAULT CIRCUIT ----------------------------------------------- BUILDING DEPT ----�-- REPRESF�d'IA X-- : - ------•-------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00001262 Date 4/26/07 Application pin number . . . 220958 ---------------------------------------------------------------------------- Special Notes and Comments INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW'FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILD NG ENVELOPE SHALL ----------------------------------------- ---------�--- -----'---------- BUILDING DEPT REP�TATIVE: C__ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00001262 Date 4/26/07 Application pin number . . . 220958 ---------------------------------------------------------------------------- Special Notes and Comments BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------- ----------------------------- --- Other -Fees- -------------------SEWER-TAP- " Z 350.00 ------ - --------- BUILDING DEPT REPR NT APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION , 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00001262 Date 4/26/07 Application pin number . . . 220958 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited ---------- Due ---------- ----------------- Permit Fee Total 466.00 466.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1216.00 1216.00 .00 .00 ----------------------------- ----- - - ---- ---------- BUILDING DEPT REPRE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . Application pin number . . Property Address . . . . . Property ID: R #. Application type description Subdivision Name . . . . . Property Use . . . . . . . Property Zoning . . . . . . Application valuation . . . 07-00001263 321767 4102 MCLISTER DR 579530-0208-0020 Date 4/26/07 TEMP POLE SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit pin number . 497610 Permit Fee . . . . 20.00 Issue Date . . . . 4/26/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 -------------------------------------------- Fee summary Charged ------------------------------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------------------------- I--- -�----------- BUILDING DEPT REPRE . APPLICANT: For Office Use Only APPLICATION FOR BUILDING PERMIT DATE: C IIEG CITY OF COLLEGE STATION — t *ff 1101 TEXAS AVENUE APPLICATION # COLLEGE STATION, TX 77840 TEMP POLE # UJ CITY kir COLLEGE STnTroN (979) 764-3570 (979) 764-3496 FAX Planning& Development Services WWW CSTX.GOV ADDRESS/LOCATION:ji ( 02 MCLS I 1'EF LOT 21/BLOCK /SUBDIVISION SOUTHERN TRACE J SEC/PH 2 BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: To Be Determined PLUMBER: Bass Plumbing HVAC: To Be Determined GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION" SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing Less Slab STRUCTURE USE: Single Family Residence WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS ENGINEERED [ X HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N/A TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ rs I 001,574 Less_Slab TOTAL AREA: 1949 HEATED AREA: 1710 (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: 4 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 4 SEWER TAP: 4" SIZE WATER TAP: 3/a" SIZE OTHER TAP: SIZE TEMP POLE ^(L� GARAGE TYPE: SINGLE ATTACHED INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Skiing and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: DOUBLE [::] TRIPLE I/ I U9TACHED n .GARPOR SIGNATURE OF APPLICANT: *If proposed work involves new commerci ns ructio commercial property, building elevations are require Official -? 6-1 Plans Examiner facade Zoning Official Composition E] s to an existing Comments: ES or NO Energy Code Compliance Information % Glazing of exterior walls 12 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER Rating 13 h PLAN REVIEW --ONE and TWO- FAMILY-OCCUPANCY•REQUIREMENTS-._--- CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: BUILDING ADDRESS: / I 1. Foundation. Requirements- Minimum City Foundation StandardsA. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated 0014 D K Il. Framing: Floor, Wall, Ceiling and Roof Requirements INAQV A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex AjbK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size; s "acin , Grade grid direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW w. ___ONE'and TWO-FAMILY OCCUPANCY -REQUIREMENTS-: ._ - CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. AII_ walls within 3' of property lin_ e_ to have protected openings. III. Stairwa Re uirements K K A. Stairway Details NA/MJ 1.. Maximum riser hei ht 7-:3/4 inches.__.-________ __-- -- - 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six (6)-inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements -••NWr A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location I PLAN REVIEW •--- ONE and TWO -FAMILY -OCCUPANCY REQUIREMENTS- ­" CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure- reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water -heaters elevated 18" when installed in'the ara a or room directly off garage VII. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N O Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for comer lots Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NNOK Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." J& U lua, PLANS EXAMINER DATE - .*1 Nil REScheck Software Version 4.0.1 Compliance Certificate Project Title: 1714 Plan Report Date: 03/16/07 Data filename: \\STYLECRAFTI\Share\ACAD\RESCheck\1714.00-Master.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 10% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: College Station, TX 77845 Stylecraft Builders, Inc. Stylecraft Builders, Inc. 4090 SH 6 South 4090 SH 6 South College Station, TX 77845 College Station, TX 77845 979-690-1222 x120 979-690-1222 x120 ewivagg@stylecraft-builders.com ewivagg@stylecraft-builders.com . . Maximum SHGC: 0.40 Your SHGC: 0.40 .. Wall 1: Wood Frame, 16" o.c.: 1293 13.0 0.0 92 Window 1: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 2: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Window 3: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Window 4: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Window 5: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Window 6: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Window 7: Metal Frame:Double Pane with Low-E: 9 0.670 6 SHGC: 0.40 Window 8: Metal Frame:Double Pane with Low-E: 9 0.670 6 SHGC: 0.40 Window 9: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Door 1: Solid: 20 0.500 10 Door 2: Glass: 18 0.440 8 SHGC: 0.40 Wall 2: Wood Frame, 16" o.c.: 1025 13.0 0.0 77 Window 10: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 11: Metal Frame: Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 12: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 13: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 14: Metal Frame:Double Pane with Low-E: 20 0.670 13 SHGC: 0.40 Window 15: Metal Frame:Double Pane with Low-E: 20 0.670 13 1714 Plan Page 1 of 2 SHGC: 0.40 Window 16: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 17: Metal Frame:Double Pane with Low-E: 15 0.670 10 SHGC: 0.40 Window 18: Metal Frame:Double Pane with Low-E: 15 0.670 10 SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: 1023 30.0 0.0 36 Ceiling 2: Cathedral Ceiling (no attic): 39 19.0 0.0 2 Floor 1: Slab -On -Grade: Unheated: 144 0.0 150 Insulation depth: 0.0' Floor 2: All -Wood Joist/fruss:Over Outside Air: 86 13.0 0.0 6 Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requireme is in the REScheck %pection Checklist. s-T`ic.�c�.� ► � 2 6 D7 Name - Title Signature Date Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 1714 Plan Page 2 of 2