PREPARED 7/30/07, 7:50:01 INSPECTION TICKET PAGE 14
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/27/07
------------------------------------------------------------------------------------------------
ADDRESS 4102 MCLISTER DR SUBDIV: SOUTHERN TRACE PH 2
CONTRACTOR STYtECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 579530-0208-0020
APPL NUMBER: 07-00001262 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
----------------------- 7------------------------------------------------------------------------
B115 01 5/31/07 RH BLDG, FRAMING TIME: 17:00
5/31/07 DP May 31, 2007 11:26:53 AM kwolfe.
05/31/2007 03:54 PM RH PDA
Nail upper floor bottom plates min. 1 " O.C. Nail osb 411
o.c. at edges in storage room. Block floor joist at
storage room. Anchors at Back door.
B115 02 6/01/07 RH BLDG, FRAMING TIME: 17:00
l 6/01/07 AP May 31, 2007 4:06:56 PM acarter.
B130 01 6/04/07 JGM BLDG, INSULATION TIME: 17:00
6/05/07 AP June 4, 2007 9:17:23 AM glsouth.
B132 01 6/11/07 OC BLDG, SHEETROCK FASTENER TIME: 17:00
6/11/07 AP June 11, 2007 8:02:20 AM glsouth.
B125 01 7/27/07 Bb BLDG, FINAL TIME: 17:00
U3b/0.1 Tom• Or— July 27, 2007 12:29:04 PM acarter.
----------------------------------- CONTINUED ONTO NEXT PAGE-----------------------------------
Date: 7/30/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1262
Address: 4102 MUSTER DR
Type
inspection Type Code
status
Inspection Result Comments
Description
B115
BLDG, FRAMING
IC
05/31/2007 03:54 PM RH PDA
B115
BLDG, FRAMING
IC
Nail upper floor bottom plates min. 1 " O.C. Nail osb 4"
B115
BLDG, FRAMING
IC
o.c. at edges in storage room. Block floor joist at
B115
BLDG, FRAMING
IC
storage room. Anchors at Back door.
E150
ELEC, FINAL
IC
July 26, 2007 9:11:02 AM acarter.
P125
PLBG, FINAL
IC
07/25/2007 11:33 AM JGM PDA
P125
PLBG, FINAL
IC
all electric
Page 1
WF0893294 / 001 City of College Statipn
PAGE
REQ. DATE: 04/27/07 04/27/07 13:42:46
LOCATION: 4102 MCLISTER DR LOC ID: 208542
REQUESTOR: STYLECRAFT BUILDERS INC ORIGIN: CUSTOMER -WALK IN
REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE:
4" SWR TAP 3/4" WTR TAP
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/27/07 SCHED COMPLETION: 04/27/07
********************************************************************************
JOB ORDER RESULT COM4=S
(8/6/2007) Gina Southerland - Re: Calking for C O for 4102 McLister Page 1
From: Joe Garcia
To: Amber Carter; banderson@stylecraft-builders.com; Benjamin McCarty; Ch...
Date: 8/3/2007 3:54 PM
Subject: Re: Calling for C.O. for 4102 McLister
WATER METER BOX HAS BEEN REPLACED, AND SEWER BOX HAS BEEN BROUGHT TO GRADE. THIS ONE IS OK NOW. JMG
>>> Terry Boriskie 08/01/07 12:14 PM >>>
Stylecraft has been notified.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 7/31/2007 3:55 pm >>>
Water box broken flagged.
Sewer buried flagged.
Paul
>>> Amber Carter 7/30/2007 2:51 PM >>>
by #07-1262
,b-,bV 2fdLd lltiL[d
6S £ CI i VH-4vis Iv i o
3S 6b6i Q�d�� �d.i.o
r�
ONO
ZZZI-069(6L6)
Loozo
Sb8LLSVXH.L`MOLLVLSHOH"I'IOD HJJlOS9'AMH'.LS060b 1
�D� sxaQ'IIng z�VxDa�Ass
�waasmu�`o��aon"u'aaaa3uw�m'rv°" v.iie
"I` NIJ
w
S
3S19 g
HDNOd Q� HAO
c�
>
Q
w x
C4
g- l I L j- S #I��'rld
F
Qa i �ax�io�
dS 0 i L I
i o i DV
is 9ga
V 1100 ° Z
�
�
i-VOLOZS:
NalSI'IDW ZOTt :NaD l-4
des
0
n
w
a�w
Qu
w
a 00 N
�xN�w
U
[-� v�
o00
- -
M �%W$p LJ,—
3QN3= DNf1SIX3
�
-----------,
_ _
MOVS13S 301S .9
-.- -- --- -.-- qp .
.2 9 i ��co
O�
--- --`a
-----------
I I I y U-
I Y ply I
tt1 W QI
d ml
I I Ij �� w
H
I IH
wI
I
LL11
IZ
O
r�
�I
- J cq
I p
^l R
06 5
cn
W
M
ovei3sMIS
--- ^
---------�--- ��+
w
JQ
y
zo
r
BUILDING PERMIT
CITY OF COLLEGE STATION ;
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------'------------------
Application Number . . . . . 07-00001262 Date 4/26/07
Application pin number . . . 220958
Property Address . . . . . . 4102 MCLISTER DR
Property ID: 579530-0208-0020
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . SOUTHERN TRACE PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 101574
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
---------------------
Structure Information 000 000 ----------------------
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1710.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
4.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
427.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. KW
Permit pin number
. 497602
Permit Fee . . .
. 466.00 Plan Check Fee
.00
Issue Date . . .
. 4/26/07 Valuation . .
. . 101574
Expiration Date .
. 10/23/07
Qty Unit Charge
Per
Extension
BASE FEE
460.00
2.00 3.0000
THOU BLDG, VAL 100001-500000
6.00
----------------------------------------------------------------------------
Special Notes and
Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS
SHALL BE PROTECTED BY AN C-FAULT CIRCUIT
-----------------------------------------------
BUILDING DEPT
----�--
REPRESF�d'IA X-- : -
------•--------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00001262 Date 4/26/07
Application pin number . . . 220958
----------------------------------------------------------------------------
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW'FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILD NG ENVELOPE SHALL
-----------------------------------------
---------�--- -----'----------
BUILDING DEPT REP�TATIVE:
C__
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001262 Date 4/26/07
Application pin number . . . 220958
----------------------------------------------------------------------------
Special Notes and Comments
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
---------------------------------------------- -----------------------------
--- Other -Fees- -------------------SEWER-TAP- " Z
350.00
------ - ---------
BUILDING DEPT REPR NT
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION ,
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number . . . . .
07-00001262
Date 4/26/07
Application pin number . . .
220958
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid
----------
Credited
----------
Due
----------
-----------------
Permit Fee Total 466.00
466.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1216.00
1216.00
.00
.00
----------------------------- ----- - - ---- ----------
BUILDING DEPT REPRE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . .
Application pin number . .
Property Address . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . .
Property Use . . . . . . .
Property Zoning . . . . . .
Application valuation . . .
07-00001263
321767
4102 MCLISTER DR
579530-0208-0020
Date 4/26/07
TEMP POLE
SOUTHERN TRACE PH 2
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit pin number
. 497610
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/26/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
--------------------------------------------
Fee summary
Charged
-------------------------------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------------------------- I--- -�-----------
BUILDING DEPT REPRE .
APPLICANT:
For Office Use Only
APPLICATION FOR BUILDING PERMIT DATE: C IIEG
CITY OF COLLEGE STATION —
t *ff 1101 TEXAS AVENUE APPLICATION #
COLLEGE STATION, TX 77840 TEMP POLE # UJ
CITY kir COLLEGE STnTroN (979) 764-3570 (979) 764-3496 FAX
Planning& Development Services WWW CSTX.GOV
ADDRESS/LOCATION:ji ( 02 MCLS I 1'EF
LOT 21/BLOCK /SUBDIVISION SOUTHERN TRACE J SEC/PH 2
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: To Be Determined PLUMBER: Bass Plumbing
HVAC: To Be Determined GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION" SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing Less Slab
STRUCTURE USE: Single Family Residence
WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS ENGINEERED [ X
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N/A
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ rs I 001,574 Less_Slab TOTAL AREA: 1949 HEATED AREA: 1710
(Cost of Labor and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS: 4
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 4
SEWER TAP: 4"
SIZE
WATER TAP: 3/a"
SIZE
OTHER TAP:
SIZE
TEMP POLE
^(L�
GARAGE TYPE: SINGLE
ATTACHED
INTERIOR WALL TYPE: Sheet Rock
EXTERIOR WALL TYPE: Skiing and/or Masonry
FOUNDATION TYPE: Slab on Grade
ROOF TYPE:
DOUBLE [::] TRIPLE
I/ I U9TACHED n .GARPOR
SIGNATURE OF APPLICANT:
*If proposed work involves new commerci ns ructio
commercial property, building elevations are require
Official
-? 6-1
Plans Examiner
facade
Zoning Official
Composition
E]
s to an existing
Comments:
ES or NO
Energy Code Compliance Information
% Glazing of exterior walls
12 %
Insulation R value of exterior walls
R13
Insulation R value of ceiling 1 (flat areas)
R30
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19
Glazing SHGC
.40
Glazing U-Factor
.65
R value of ductwork
R6
A/C SEER Rating
13
h
PLAN REVIEW
--ONE and TWO- FAMILY-OCCUPANCY•REQUIREMENTS-._---
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
DATE:
BUILDING ADDRESS: / I
1. Foundation. Requirements- Minimum City Foundation StandardsA.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
0014 D K
Il. Framing:
Floor, Wall, Ceiling and Roof Requirements
INAQV
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
AjbK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size; s "acin , Grade grid direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
w. ___ONE'and TWO-FAMILY OCCUPANCY -REQUIREMENTS-: ._ -
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. AII_ walls within 3' of property lin_ e_ to have protected openings.
III. Stairwa Re uirements
K
K
A. Stairway Details
NA/MJ
1.. Maximum riser hei ht 7-:3/4 inches.__.-________
__-- -- -
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six (6)-inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements -••NWr
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
I
PLAN REVIEW
•--- ONE and TWO -FAMILY -OCCUPANCY REQUIREMENTS- "
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure- reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water -heaters elevated 18" when installed in'the ara a or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N O
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for comer lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NNOK
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
J& U lua,
PLANS EXAMINER
DATE
- .*1
Nil
REScheck Software Version 4.0.1
Compliance Certificate
Project Title: 1714 Plan
Report Date: 03/16/07
Data filename: \\STYLECRAFTI\Share\ACAD\RESCheck\1714.00-Master.rck
Energy Code: 2003 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 10%
Heating Degree Days: 1788
Construction Site: Owner/Agent:
Designer/Contractor:
College Station, TX 77845 Stylecraft Builders, Inc.
Stylecraft Builders, Inc.
4090 SH 6 South
4090 SH 6 South
College Station, TX 77845
College Station, TX 77845
979-690-1222 x120
979-690-1222 x120
ewivagg@stylecraft-builders.com
ewivagg@stylecraft-builders.com
. .
Maximum SHGC: 0.40 Your SHGC: 0.40
..
Wall 1: Wood Frame, 16" o.c.:
1293 13.0
0.0
92
Window 1: Metal Frame:Double Pane with Low-E:
3
0.670
2
SHGC: 0.40
Window 2: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Window 3: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Window 4: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Window 5: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Window 6: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Window 7: Metal Frame:Double Pane with Low-E:
9
0.670
6
SHGC: 0.40
Window 8: Metal Frame:Double Pane with Low-E:
9
0.670
6
SHGC: 0.40
Window 9: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Door 1: Solid:
20
0.500
10
Door 2: Glass:
18
0.440
8
SHGC: 0.40
Wall 2: Wood Frame, 16" o.c.:
1025 13.0
0.0
77
Window 10: Metal Frame:Double Pane with Low-E:
4
0.670
3
SHGC: 0.40
Window 11: Metal Frame: Double Pane with Low-E:
4
0.670
3
SHGC: 0.40
Window 12: Metal Frame:Double Pane with Low-E:
4
0.670
3
SHGC: 0.40
Window 13: Metal Frame:Double Pane with Low-E:
4
0.670
3
SHGC: 0.40
Window 14: Metal Frame:Double Pane with Low-E:
20
0.670
13
SHGC: 0.40
Window 15: Metal Frame:Double Pane with Low-E:
20
0.670
13
1714 Plan
Page 1 of 2
SHGC: 0.40
Window 16: Metal Frame:Double Pane with Low-E:
4
0.670
3
SHGC: 0.40
Window 17: Metal Frame:Double Pane with Low-E:
15
0.670
10
SHGC: 0.40
Window 18: Metal Frame:Double Pane with Low-E:
15
0.670
10
SHGC: 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
1023 30.0
0.0
36
Ceiling 2: Cathedral Ceiling (no attic):
39 19.0
0.0
2
Floor 1: Slab -On -Grade: Unheated:
144
0.0
150
Insulation depth: 0.0'
Floor 2: All -Wood Joist/fruss:Over Outside Air:
86 13.0
0.0
6
Furnace 1: Forced Hot Air: 80 AFUE
Air Conditioner 1: Electric Central Air: 13 SEER
Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requireme is in the REScheck %pection Checklist.
s-T`ic.�c�.� ► � 2 6 D7
Name - Title Signature Date
Project Notes:
All U-Factors and SHGC are at entered at higher than actual amounts.
Actual amounts are lower, but are entered higher to account for
differences in ratings per material.
1714 Plan Page 2 of 2